| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.4 LAccepted-AOC 10 A 1 JAHURA BAZAR LANE KASBA KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | ₹53.4 L | L1 | Accepted-AOC Lowest Rate. |
| 2 | L2₹53.5 LRejected-Finance | ₹53.5 L | L2 | Rejected-Finance Higher Rate. |
| 3 | L3₹54.7 LRejected-Finance 46 6 PRINCE GOLAM HOSSAIN SHAH ROAD JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | ₹54.7 L | L3 | Rejected-Finance Higher Rate. |
| 4 | Rejected-Technical MOTHURAPUR 1 | - | - | Rejected-Technical See Tech. Doc. |
| 5 | Rejected-Technical | - | - | Rejected-Technical See Tech. Doc. |
Tender Value
₹53.7 L
EMD Value
₹1.1 L
Closing Date
16 Jan 2026, 3:00 pmClosed
Executive Engineer-II PWD KNHD
P16 INDIA EXCHANGE PLACE EXTENSION 2ND FLOORKIT BUILDING Kolkata 700 073
Necessary Civil Work in connection with renovation of Electrical Work of New OPD Building at Medical College and Hospital, Kolkata
2025_WBPWD_976878_1
WBPWD/EE-II/KNHD/NIT-46e/25-26
Open Tender
CIVIL WORKS
90 days
Kolkata Medical College Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.1 L
Yes
1 Apr 2026
19 Dec 2025
19 Jan 2026
19 Dec 2025
16 Jan 2026
19 Dec 2025
Taking out existing partition/ceiling of particle board, masonite board, ply board, soft board etc. of any thickness and refixing same in new position with necessary clamps making holes in walls, floor, roof and mending damages if any.[concrete plaster will be paid separately] Ground floor to 3rd floor
Stripping off worn out plaster and raking out joints of walls ceillings etc. upto any height and in any floor including, removing rubbish and stacking anywhere within the compound as directed. Ground floor to 3rd floor
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Variety Ground floor
1st floor
2nd floor
3rd floor
4th floor
Brick work with 1st class bricks in cement mortar (1:6) In superstructure Ground floor
1st floor
2nd floor
3rd floor
4th floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20 mm thick plaster Ground floor
1st floor
2nd floor
3rd floor
4th floor
With 1:4 cement mortar 10 mm thick plaster Ground floor
1st floor
2nd floor
3rd floor
4th floor
Rendering the surface of walls and ceiling with white cement basedwall putty of approved make and brand(1.5mm thick)
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Ground floor
1st floor
2nd floor
3rd floor
Polishing only of old marble or terrazo work with oxalic acid powder using 33 gms/ sq.m. by manual labour / machine where necessary. From ground floor to 3rd floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian Ground floor
1st floor
2nd floor
3rd floor
4th floor
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. 35 mm thick shutters (single leaf) Ground floor
1st floor
2nd floor
3rd floor
4th floor
Extra over item SL. No. 11 for providing: Vision aperture (round or retangular in shape) with 7.4kg. Per sq.m./ 3mm thick glass pane with wooden beads. (Cost of glass panes and wooden beads will be paid separately).
Rabbet cutting in shutters [Note: Mode of measurement-Measurement shall be made on the basis of area of shutter]
Double leaf shutters [Note: Mode of measurement-Measurement shall be made on the basis of area of shutter]
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) 3 mm thick (weighing 7.4 kg/Sq.m)
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, 200mm Length
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 75mm. X 3.50mm.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With continuous plate base (Hexagonal/ Round rod) 150 mm grip x 12 mm dia rod.
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. 300mm x 19mm dia. bolt.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 300mm long x 10mm dia. bolt.
Door stopper.(Brass)
Godrej Hydraulic door closer fitted and fixed complete. Medium type
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) Above area 2.5 Sq.m
Reparing collapsible gate by cutting out all rivets as necessary re- assambling all members including welding pieces of channels, sraightening bent bars and rivetting with new rivets and fitting in position and painting two coats.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 16 Kg./sq.mtr and above In ground floor
1st floor
2nd floor
3rd floor
4th floor
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). 15 Micron colour annodizing. Casement window ( 40 mm Depth series) Outer frame.
Mullion.
Shutter.
Glazing clip.
Cleat angle. (Non-annodized)
Fixed glazing. Top, bottom and side member
Mullion.
Glazing clip.
Movable door shutter. Door frame. (Top & sides).
Shutter : Top rail.
Bottom rail.
Lock rail.
Door vertical
Glazing clip.
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. Openable / Casement window. Ground floor
1st floor
2nd floor
3rd floor
Fixed glazing. Ground floor
1st floor
2nd floor
3rd floor
Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. In ground floor
2nd floor
Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge.
Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge. 300 mm long
Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. For openable / Casement windows EPDM / weather gasket for outer frame and mullion.
weather gasket / wool pile for door vertical.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 6mm thick clear glass.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; clear, toughened glass conforming to IS: 2553-1992 (part-II) 10mm thick
Supplying 125 mm. Dia acrylic handle for aluminium door as per approved make & brand. Colour
Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Charge. 150 mm.
Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) one Coats, Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) Standard Quality
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-in- charge.The rate includes the cost of labour, adhesive and all incidental charges thereof. Glossy/Matt/Suede excluding surface texture or metallic lustre. Thickness of laminate 1.5mm
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
Supplying,fitting & fixing in position suspended false ceiling with frame work of aluminium hollow section of size 50mm X 25mm (2.0mm thickness) combined with aluminium corners of size 38mm X 25mm, suspended by aluminium hollow tube section of size 38mm X 25mm having size of 600mm X 600mm ceiling with aluminium composit panels (ACP) - Interior grade of thickness 3.0mm comprising of proctective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction of Engineer-in-charge. Ground floor to 3rd floor
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system ( T-Grid, load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 6 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density > 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor. False Ceiling (with 6mm thick Fibre Cement Designer Board and E-Grid T-2430). In ground floor
1st floor
2nd floor
3rd floor
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_2380033.xls
BOQ • 0.45 MB
2911_ii_NRe_6th5696FY011019_M3_ChangeOK.pdf
Tender Documents • 0.99 MB
Download all tender documents and submit your bid