Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹32.5 L+₹85,680 (2.71%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹33.6 L+₹2.0 L (6.20%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹34.6 L+₹3.0 L (9.42%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹35.9 L+₹4.3 L (13.6%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
27 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIRS/MAINTENANCE OF LT FEEDER PILLARS, HT/LT OVERHEAD LINES, HT/LT UNDER GROUND CABLES, SERVICE CONNECTIONS AND CONNECTED WORKS AT DRDL/ASL AREA UNDER GE (I) RND KANCHANBAGH, HYDERABAD
2020_MES_408473_1
GE I KBAGH TOKEN 68 OF 2020 2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
4 Mar 2021
31 Dec 2020
29 Jan 2021
31 Dec 2020
27 Jan 2021
14 Jan 2021
1 Jan 2021 - 7 Jan 2021
60 days
Amount
Supply, Laying, Test & Commissioning LT UG cable of size 240 sqmm; 3.5 core XLPE insulated, armoured, multistranded, aluminium conductor electric cable of 1100 volts grade laid in ground, through trench/pipes including connecting with aluminium lugs etc and including removing old unserviceable cable all as specified and directed.
All as per Item No 1 here-in-before above but of size 3.5 core 185 sqmm complete all as specified
All as per Item No 1 here-in-before above but of size 3.5 core 150 sqmm complete all as specified
All as per Item No 1 here-in-before above but of size 3.5 core 70 sqmm complete all as specified
All as per Item No 1 here-in-before above but of size 3.5 core 16 sqmm complete all as specified.
Supply, lay, test and commissioning of XLPE insulated HT cable, screened PVC bedded, galvanized steel strip or wire armoured electric power cable of 6350(UE) / 11000 (E) volts grade with multistranded aluminium conductor of cross sectional area 95 sqmm ; 3 core including providing cable lugs and to be laid in trenches, fixed along the poles bare or through pipes complete and removing the unserviceable cable all as specified and directed.
Excavation in trenches not exc.1.5 Mtr in width and not exceeding 1.5 Mtr in depth for laying of cables and getting out in hard/dense soil etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick using soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified.
Supply and filling Dry river sand for cushioning to cables in trenches including spreading, levelling complete all as specified and directed. Note:- Only punned thickness will be considered for measurement purpose.
Supply and lay well burnt brick class 'B' of locally available as protection of cable in trenches all as specified and directed.
Material and Labour for cutting existing BT road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and directed
Supply and Fix in repairs GI tubing 100 mm bore light grade for protection of earth conductor or cable and all as specified and directed.
All as per srl item No.13 here-in-before above, but 80 mm bore
All as per srl item No. 13 here-in-before above, but 50 mm bore
All as per srl item No. 13 here-in-before above, but 40 mm bore Make for Item No: 13 to 16 :- Jindal/Prakash/ Oswal
Material & Labour for stringing and fixing in position of ACSR conductor in OH line for HT/LT connections of squirrel /Weasel/ mink etc as per site requirement including provision of aluminium binding wire complete all as specified and directed.
Supplying and Fixing ACB 630Amps, 415V, 50KA, drawout type with Microprocessor release IPR-1 (4Pole) inbuilt O/L, S/C & EF protection, fixed in existing panel boards including cable connections, aluminium lugs, glands & terminal adaptors as required and testing complete all as specified and directed. Make : Havells/Legrand/Siemens
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m deep below normal ground level with top edge of earth plate, not less than 1.5 m below normal ground level connected to galvanized iron earth strip of size 32x6mm dia by means of bolts, nuts/check nuts and washers etc of galvanized iron, protected by galvanized iron pipe light grade 40mm dia upto a length of 7.5 m away from earth electrode and connected to main switch/control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 6 mm dia TMT Bars at 140 mm cc both ways, watering pipe 20 mm dia light grade GI, funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in Electrical plate No. 3 SSR Part I and testing complete including removing unserviceable items all as specified and directed.
S&F in repairs Earth continuity conductor 32x6 GI strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situatin for loop earthing etc. complete all as directed
S&F in replacment MCCB with rating of 100Amps,415Volts 4pole with 25KA breaking capacity,thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be 100% of ultimate breaking capcity(Icu) including suitable spreader links & connectors as required at sire for fixing. MCCB should be with suitable spreaders and phase barriers for each terminals with all accessories all as specified and directed.
All As per item No :21 above but 125Amps, 4 pole, 25KA
All As per item No :21 above but 200Amps, 4 pole, 35/36KA
All As per item No :21 above but 250Amps, 4 pole, 35/36KA
All As per item No :21 above but 400Amps, 4 pole, 35/36KA
All As per item No :21 above but 630Amps, 4 pole, 50KA Make for item No. 21 to 26 : Havells/ L&T/Legrand
Supplying and Fixing Switch Disconnector 4 Pole of the following capacities fixed in distribution board/ panel boards including cable connections, aluminium lugs, glands and testing including taking down unserviceable Switch Disconnectors complete :-
Switch Disconnector 40 Amps, 4 pole, 415 Volts
Switch Disconnector 63 Amps, 4 pole, 415 Volts
Switch Disconnector 100 Amps, 4 pole, 415 Volts
Switch Disconnector 125 Amps, 4 pole, 415 Volts
Switch Disconnector 250 Amps, 4 pole, 415 Volts
Switch Disconnector 320 Amps, 4 pole, 415 Volts
Switch Disconnector 400 Amps, 4 pole, 415 Volts
Supplying and Fixing sheet metal enclosure factory made, IK-06 protection & IP-30 protection (MCCB Box) suitable for MCCB-TP/TPN (400)Amps 415 Volts including necessary fastners required for fixing at site and removing the unserviceable item all as specified and directed.
Supply and laying un reinforced precast concrete cable cover, class HV, type 1, flat size 300 x 180 x 40 mm for protection of HT cable including taking down unserviceable cable cover complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as directed
All as per srl item No. 30 here-in-before above but of size 120 sqmm to 185 sqmm
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
All as per srl item No. 32 here-in-before above but of size 120 sqmm to 185 sqmm
All as per srl item No. 32 here-in-before above but of size 240 sqmm to 300 sqmm
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
All as per srl item No. 35 here-in-before above but of size 120 sqmm to 185 sqmm. Make for item No. 30 to 36 : Raychem/Denson/ 3M
Supply and fix repairs of Street light terminal boxes made out with SMC material, shock & dust proof of size 350 X250 X 145mm as per IS and including epoxy terminal connectors and MCB SP 6A -1 No, earth termination including 02 sets of 25x6mm flat iron clamps with nuts, bolts and washers and two coats of aluminium paint over a coat of primer for flat iron clamps complete all as specified and directed. MAKE :- Sintex/Hensel or equivalent as approved by GE.
Supply and fix repairs of Steel tubular swaged poles type 410 SP 31of 9.0 metre length complete with mild steel base plate final taper plug bolts, nuts and washers screws, pole shall be painted with two coat of black bituminous paint throughout internally and externally upto planting depth and the remaining external complete pole portion shall be painted alluminium paint in two coats over a coat of red oxide primer painting, painting of black & yellow alternate strips of 30cm each externally from ground level upto 1.5m with synthetic enamel paint, complete all as specified and directed. Make :- M/s Bombay Tubes/ M/s Jindal Steel Products/ M/s India Tubes Co/ M/s Bharat poles/ National Tubing
Supply and fix repairs of PVC insulated copper conductor FR grade 2.5 sqmm,three core cable, ISI marked.
M&L for PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in coping of pole including form work for street light poles complete all as directed.
M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete
Supply, fix, testing and commissioning of Air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level vertically operated including locking arrangement for operating handle with and including 7 levers Navtal lock complete suitable for current rating of 400 Amps HT 11 KV working pressure all as specified and directed. Make: Jaipuria or any make approved by state electricity board
Supply, install, test and commissioning LT panel board, factory made cubical type, confirming IEC-60439-122, indoor type main frame made out of 2.0mm thick CRCA sheet totally enclosed epoxy powder coating of RAL-7032 (Simens grey) mat finish after seven tanks treatment process. The panel shall be fabricated providing necessary ventilations, weather, dust and vermin proof suitable for working 415 volts, 3 phase, 50 Hz having aluminium bus bars of capacity 400 Amps and half neutral duly colour coaded sleeves and supported with DMS/SMC insulators complete with Digital type multifunction meter V,A KVA, KVAR, PF, KWAH with class 1 accuracy including CL-1, 15 VA CTs of ratings as per the busbar rating : ASS, VSS, set of three LED phase indicating lamps duly prewired with FRLS standard copper conductor of not less than 1.5 sqmm and the panel should be mounted on ‘C’ channel base ISMC 75 frame duly painted with anti corrosive paint. The doors should be provided with nitrile rubber gaskets and the rating of switch gears to be provided on each compartment and reflective stickering of switch gears to be provided as per the circuit connection on the compartments. The panel board shall be suitable to accommodate and including cost of the following switch gear items including removing unserviceable panel from its location and necessary PCC foundation as required at site for mounting the panel complete all as specified and directed.
(a) MCCB 200 Amps, 4 pole, 36 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics- 01 No. (Incoming) (b) On load change over switch 200 Amps, 4pole, conforms IEC-60947-3 (c) MCCB 100 Amps, 4 pole, 16 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics- 01 No. (out going) (d) MCCB 63 Amps, 4 pole, 16 KA,Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics- 01 No. (out going) (e) MCCB 32 Amps, 4 pole, 16 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-04 Nos. (out going)
Ditto all as per Item No: 43 above but outdoor type made out of 3.15 mm thick CRCA sheet with aluminium bus bar of capacity 600 Amps, including fixing of the following items (a) MCCB 400 Amps, 4 pole, 36 KA,Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-01 No. (Incoming) (b) On load change over switch 400 Amps, 4pole, conforms IEC-60947-3 (c) MCCB 250 Amps, 4 pole, 25 KA, fThermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-01 No. (out going) (d) MCCB 100 Amps, 4 pole, 16 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-02 Nos. (out going) (e) MCCB 63 Amps, 4 pole, 16 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-03 Nos. (out going)
Ditto all as per Item No: 43 above but outdoor type made out of 3.15 mm thick CRCA sheet with aluminium bus bar of capacity 600 Amps, including fixing of the following items (a) MCCB 400 Amps, 4 pole, 36 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-01 No. (Incoming) (b) MCCB 315 Amps, 4 pole, 25 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-02 Nos. (out going) (c) MCCB 250 Amps, 4 pole, 25 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-02 Nos. (out going) (d) MCCB 100 Amps, 4 pole, 16 KA, Thermal magnetic, adjustable short circuit & over current protection Icu=100% Ics-02 Nos. (out going)
Taking out the LT ACB of 400 to 800Amps capacity of any make and model from the existing position, carrying out servicing, overhauling of the same, cleaning the unit thoroughly with carbon tetrachloride, applying lubricant oil and grease for the moving contacts, checking of the entire components for proper function on O/L and S/C, checking the trip device and circuit wiring complete reconnecting back and testing complete to the entire satisfication of Engr-in-charge. Note:- (i) The service technician should be well qualified and authorized by any of the approved LT switchgear manufacturer. (ii) The contractor is wholly responsible for safety of the technician while performing the job. (iii) Spares shall be measured and paid separately.
All as per item No. 46 above but 1000 to 1600 Amps capacity of any make and model.
All as per item No. 46 above but 2000 to 4000 Amps capacity of any make and model. Note for item No 46 to 48 spares shall be measured and paid separately
Supply and replacing of 6 way secondary isolating contact block for ACB 400 Amps to 4000 Amps capacity
Supply and replacing of micro switch on volt metric release for ACB 400Amps to 4000 Amps capacity.
S&F micro switch for common indication of O/L & S/C for ACB 400 Amps to 4000 Amps.
S&F service position Micro switch for ACB 400 Amps to 4000 Amps.
S&F Lockable Trip push button for ACB 400 Amps to 4000 Amps.
S&F Racking interlock for ACB 400 Amps to 4000 Amps.
S&F Auxiliary contract Block for ACB 400 Amps to 4000 Amps.
S&F Earth fault release ACB 400 Amps to 4000 Amps.
S&F CTs for ACB 800 Amps to 4000 Amps.
S&F fixed arcing contact for 800 Amps to 1600 Amps ACB.
All as per item No 59 above but for 2000 to 4000 Amps ACB
S&F moving arcing contacts for 800 Amps to 1600 Amps ACB. Make for ItemNo: 49 to 60 :- L&T/Legrand/C&S/Havells
Supply & Fix 25 KVAR heavy duty power capacitor box/ cylindrical type MPP, 415/440V, 50HZ, 3ph including removing unserviceable power capacitor complete all as specified
All as per Item No: 61 above but of capacity 20 KVAR
All as per Item No: 61 above but of capacity 15 KVAR
All as per Item No: 61 above but of capacity 10 KVAR
Ditto as per Item No: 61 above but of capacity 05 KVAR Make for Item No: 61 to 65 : L&T/ Havells/Neptune
Supply & Fix capacitor duty contactors, 415 volts Suitable for 25 KVAR capacitor including removing the old unserviceable item all as specified and directed.
All as per Item No 66 above but suitable to 20KVAR
All as per Item No 66 above but suitable to 15KVAR
All as per Item No 66 above but suitable to 10KVAR
All as per Item No 66 above but suitable to 05KVAR
Supply & Fix over current/ earth fault control relay, 240 volts AC complete including removing unserviceable item all as specidied and directed.
Supply & Fix Auxilary Contact bolck (1NO + 1NC) for contactor complete including removing unserviceable item all as speicified and directed.
Supply & Fix HRC DIN/ Bolted fuse Link 20 amps of size as per existing conforms IEC-60269-2 complete including removing unserviceable item all as speicified and directed.
Supply & Fix Cylindrical fuse 415 volts 6 amps
Supply & Fix APFC controller, 1 CT inputs, 8steps, 415 volts, capacitor failure indication of size 96x96mm with testing inlcuding removing the unserviceable item. Make : L&T/Havells/ Neptune
Supply & Fix epoxy type current transformer 400/5A to 800/5A Class 1, VA 15 50Hz complete including removing unserviceable item all as specified and directed. Make : Kappa/L&T/C&S
Testing/ Programming the existing APFC controller of any type/make and testing control wiring, capacitors, contactors, MCB complete capacitor bank panel all as specified and directed.
Supply and fix 6.35/11 KV(E) Grade Aerial bunched cable with 3(three) power cores (Stranded, compacted circular Aluminium conductor screened with Black extruded semi-conducting compound , natural coloured XLPE insulated core screened with Black extruded semi conducting compound and one layed of copper tape and covered with black extruded PVC (Core identification by colour tape marking red, yellow & Blue with colour tape placed longitudinally under the copper tape) and insulated massenger wire shall be stranded non -compacted circular Aluminium alloy conductor of size 3c x 185 sqmm + 1 x 150 sqmm (insulated messenger wire) including all necessary fixing spares like, bolts, hooks & D-clamps all as specified and directed. Make : Gloster/KEI/Universal Cables
M&L 11KV grade pin type, composite polymeric insulator white, brown or green insulator of clevis/Tounge/socket or ball type spindle inclduing nuts and bolts of size type as specified by the manufacturer conforming IS- 61109 including all galvanised steel disc fittings as required at site and removing of unserviceable insulators complete all as specified and directed. Make :- Jaipuria/Rashtriya Electrical/Denson or make approved in the state Electricity board
S&F cable jointing kit for cold shrink straight through joint (epoxy) for 1.1 KV grade XLPE, PVC insulated and sheathed aluminium conductor under ground cable including thimbles, nuts & bolts, washers etc and testing after jointing complete, all as directed for the following sizes. Make: M-seal/Raychem/Transeal/Denson
6 sqmm to 16 sqmm 4 core
25 sqmm to 50 sqmm 3.5 core
70 sqmm to 120 sqmm 3.5 core
150 sqmm to 185 sqmm 3.5 core
240 sqmm to 300 sqmm 3.5 core
400 sqmm to 500 sqmm 3.5 core
Spray Painting to LT Panel board indoor/out door type of different size with two coats of synthetic enamel paint of approved colour and to achieve smooth finish complete all as specified and directed. Make of Paint : Asian/Nerolac/Berger
M&L for repairing existing LT Panel board , like brazing/welding , hinges, locking arrangenent supports, of any size as directed including nuts, bolts, washers welding, bending, cold or hot, drilling holes for bolts in any shape or size as directed.
M&L for replacing spreader terminals 3 pole existing make/model as required at site
M&L for replacing spreader terminals 4 pole existing make/model as required at site
M& L for replacing aluminium lugs for LT UG cable of size 35-50sqmm
M& L for replacing aluminium lugs for LT UG cable of size 70-95sqmm
M& L for replacing aluminium lugs for LT UG cable of size 120-150sqmm
M& L for replacing aluminium lugs for LT UG cable of size 185-240sqmm
M& L for replacing aluminium lugs for LT UG cable of size 300-400 sqmm
S&F in replacement of LED indication lamp for LT Panel R-Y-B etc for control panel including associated wiring, if reqd, complete all as specified and directed.
S&F in replacement of rotary handle for MCCB of suitable size complete all as specified and directed. Make : Havells/L&T/Legrand
SRI SAI ENTERPRISES
M/s K L M INFRATECH
BHAGYARAM ENTERPRISES
ELEVATORS MAINTENANCE ENGINEER WORKS
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
UNITY ENGINEERING TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .