Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹48.1 CrAccepted-AOC | ₹48.1 Cr | 1 | Accepted-AOC L1 |
Tender Value
₹43.5 Cr
EMD Value
₹65.2 L
Closing Date
30 Jun 2020, 5:00 pmClosed
DSW cum EO, LUVAS Hisar
2nd floor, Giri Center, CCSHAU campus, Hisar
As per DNIT
2020_HRY_131887_1
DSW/20/100 Residences/3rd/JUNE/2020
Open Tender
Construction Works
547 days
Hisar
As per DNIT
3 documents required · 3 mandatory
₹50,000
LUVAS
₹65.2 L
Hisar
12 Nov 2020
16 Jun 2020
1 Jul 2020
16 Jun 2020
30 Jun 2020
16 Jun 2020
22 Jun 2020
Amount
CIVIL WORK BELOW PLINTH LEVEL
Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation , including disposal of all surplus soil as directed within a lead of 30 Mtrs.
Centring and shuttering for faces of walls,partitions, retaining Walls, well steining and the like (vertical or battering) including attached pilasters, buttresses etc. 9.5
Centring and shuttering for sides and soffits of beams haunchings, girders, bressumers and lintels. 9.7
Centring and shuttering for columns (square or rectangular or Polygonal in plan) 9.9
Centring and shuttering for columns (circular or curved in plan) 9.10
Shuttering for faces of concrete foundations and foundations beams (vertical or battering) 9.13
Cement concrete 1 : 5 : 10 with stone aggregate 40 mm Nominal sie in foundation and plinth.10.34
Cement concrete 1 : 4 : 8 with stone aggregate 20 mm nominal size in foundation and plinth. Note:- Surface should be smooth like floor so that water proofing treatment may be carried out easily. Plaster will not be allowed and if required due to weaviness, No payment will be allowed. 10.38
Cement concrete 1:2:4 with stone aggregates 20 mm nominal size in foundation and plinth.10.41
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- charge in foundation and plinth. Note: 1. Cement content considered in this item is @ 350 kg/cum. 2.In case cement content of the Design Mix is more than the specified in above items, nothing extra willbe paid for extra cement to be consumed. In case cement content of the design mix is less than the specified in above item, then less cement used as per design mix is recoverable separately as per base rates. 10.68
First class brick work laid in cement sand mortar 1:4 in foundation and plinth. 11.4
11.43 cm thick brick wall laid in cement sand mortar 1:4 without reinforcment in Foundation and plinth.11.47
Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights / depths / storeys / basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 18.22
CIVIL WORKS ABOVE PLINTH LEVEL
Centring and shuttering for flat surfaces such as suspended floors, Roofs,landings, chhajjas, shelves etc. inclination not exceeding 25 degree with horizontal. (a) First Storey 9.1
Second Storey 9.1
Third Storey 9.1
Fourth Storey 9.1
Fifth Storey 9.1
Sixth Storey 9.1
Seventh Storey 9.1
Centring and shuttering for faces of walls,partitions, retaining Walls, well steining and the like (vertical or battering) including attached pilasters, buttresses etc. (a) First Storey 9.5
Second Storey 9.5
Third Storey 9.5
Fourth Storey 9.5
Fifth Storey 9.5
Sixth Storey 9.5
Seventh Storey 9.5
Centring and shuttering for sides and soffits of beams haunchings, girders, bressumers and lintels. (a) First Storey 9.7
Second Storey 9.7
Third Storey 9.7
Fourth Storey 9.7
Fifth Storey 9.7
Sixth Storey 9.7
Seventh Storey 9.7
Centring and shuttering for staircases with sloping soffits including risers and stringers. (a) First Storey 9.8
Second Storey 9.8
Third Storey 9.8
Fourth Storey 9.8
Fifth Storey 9.8
Sixth Storey 9.8
Centring and shuttering for columns (square or rectangular or Polygonal in plan). (a) First Storey 9.9
Second Storey 9.9
Third Storey 9.9
Fourth Storey 9.9
Fifth Storey 9.9
Sixth Storey 9.9
Seventh Storey 9.9
Centring and shuttering for columns (circular or curved in plan) (a) First Storey 9.10
Second Storey 9.10
Third Storey 9.10
Fourth Storey 9.10
Fifth Storey 9.10
Sixth Storey 9.10
Centring and shuttering for corbel, parapets, fascias and other similar items, including edges. (a) Second Storey 9.11
Third Storey 9.11
Fourth Storey 9.11
Fifth Storey 9.11
Sixth Storey 9.11
Seventh Storey 9.11
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- charge in first storey upto 4 meters above plinth level. Note: 1. Cement content considered in this item is @ 350 kg/cum. 2.In case cement content of the Design Mix is more than the specified in above items, nothing extra willbe paid for extra cement to be consumed. In case cement content of the design mix is less than the specified in above item, then less cement used as per design mix is recoverable separately as per base rates. (a) First Storey 10.75
Second Storey 10.75
Third Storey 10.75
Fourth Storey 10.75
Fifth Storey 10.75
Sixth Storey 10.75
Seventh Storey 10.75
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement but including centring and shuttering, laid in position complete in all respects. (a) Second Storey 10.81 +10.95a
Third Storey 10.81 +10.95a
Fourth Storey 10.81 +10.95a
Fifth Storey 10.81 +10.95a
Sixth Storey 10.81 +10.95a
Seventh Storey 10.81 +10.95a
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. (a) Second Storey 10.86+10.95a
Third Storey 10.86+10.95a
Fourth Storey 10.86+10.95a
Fifth Storey 10.86+10.95a
Sixth Storey 10.86+10.95a
First class brick work laid in cement sand mortar 1:6 in 1st storey upto 4 metre above plinth level. (a) First Storey 11.7
Second Storey 11.7
Third Storey 11.7
Fourth Storey 11.7
Fifth Storey 11.7
Sixth Storey 11.7
Seventh Storey 11.7
11.43 cm thick brick wall laid in cement sand mortar 1:4 in super-structure. (a) First Storey 11.48a
Second Storey 11.48a
Third Storey 11.48a
Fourth Storey 11.48a
Fifth Storey 11.48a
Sixth Storey 11.48a
Seventh Storey 11.48a
11.00 cm thick brick wall using flyash – lime based bricks (IS: 1289-1-2002) laid in cement sand mortar 1:4 in super structure. (a) Second Storey 11.101
Third Storey 11.101
Fourth Storey 11.101
Fifth Storey 11.101
Sixth Storey 11.101
Masonry work using flyash - lime based bricks (IS:12894-2002) laid in cement sand mortar 1:6 in super structure. (a) Second Storey 11.102
Third Storey 11.102
Fourth Storey 11.102
Fifth Storey 11.102
Sixth Storey 11.102
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16. 13.50
Cement Concrete 1:2:4 gola 10cm x 10cm quadrant along junction of roof with parapet wall finished smooth, where specified. 13.64
Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. Make:- Supreme, Finolex, Prince. (a)100 mm dia PVC pipe 6 kg. pressure. 13.89
150 mm dia PVC pipe 6 kg. pressure. 13.89b
Providing and fixing PVC Bend ISI Mark. Make:- Supreme, Finolex, Prince. (a) 100 mm dia PVC Bend. 13.90a
150 mm dia PVC Bend. 13.90b
Terracing consisting of 19 mm thick heat resistant tiles for roof insulation ,300 mm x 300 mm laid on 20 mm thick 1:3 cement coarse sand mortor including grouting with neat white cement over average 75 mm thick screed of 1:8:16 including two coats of bitumen laid hot at 1.65 Kg per sqm on top of RCC slab & cleaning of top surface complete .the tiles shall be made of white cement blended with fibrous polymer having flextural stress value of ≥ 150 Kg/Cm 2 & thermal conductivity value ≤ 0.18 w/m.k. (Note :- No extra rate for rubbing will be paid. Contractor should quote the rate accordingly.. 13.97
Providing and fixing tiled false ceiling of approved materials of size 595x595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge globalwhite color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. ( Make Gyproc, Armstrong, Grid Square ) 13.98b
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. (a)First Storey 14.4
Second Storey 14.4
Third Storey 14.4
Fourth Storey 14.4
Fifth Storey 14.4
Sixth Storey 14.4
Seventh Storey 14.4
1st class spotless uniform color Kotah stone Flooring (RAATIA Varity) , minimum 25mm thick, in any pattern as specified over 20 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including single piece used in staircase and minimum 550x550mm in flooring, Granite rubbing and polishing. (Note :- No extra rate for granite rubbing will be paid. Contractor should quote the rate accordingly.) (a)First Storey 14.62
Second Storey 14.62
Third Storey 14.62
Fourth Storey 14.62
Fifth Storey 14.62
Sixth Storey 14.62
Seventh Storey 14.62
Stamping or making grooves on top of steps in stair case. 14.82
Providing & fixing Rectified Ceramic tiles of size 400mm X 400mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortor 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. Note: 1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO. (a) Second Storey 14.91
Third Storey 14.91
Fourth Storey 14.91
Fifth Storey 14.91
Sixth Storey 14.91
Providing Double edge moulding to 17-20mm thick Granite counters, Vanities, treads of stair case etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.(Moulding) 14.98ii
12mm thick cement plaster on walls (1:6). (a) First Storey 15.7
Second Storey 15.7
Third Storey 15.7
Fourth Storey 15.7
Fifth Storey 15.7
Sixth Storey 15.7
Seventh Storey 15.7
15mm Thick Cement Plaster 1:6 on the rough side of single or half brick wall. (a) First Storey 15.12
Second Storey 15.12
Third Storey 15.12
Fourth Storey 15.12
Fifth Storey15.12
Sixth Storey 15.12
Seventh Storey 15.12
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. 16.3
Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on mettalic Surfaces etc. 16.9
Applying priming coat with cement primer in all shades on birla putty surface. 16.25
Painting two coats with plastic emulsion paint on walls on new work to give an even shade. 16.30
Distempering with washable oil bound Distemper two coats over one priming coat on new work. 16.58
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (J.K./ Birla). 16.81
Chowkats of commercial hard wood such as hollock, champ, Or malaysian sal, etc., (Non-coniferous timber other than teak conforming to I.S. specification no. 1003 kiln seasoned), of doors and windows including iron hold fasts, corner straps, screws, bolts for hold fasts, etc., complete fixed in positon. 17.12
Supplying and fixing glass panes with moulding of commercial hard wood such as hollock, champ, only (Non coniferous timber other than teak, conforming to I.S. specification No. 1003, kiln seasoned)-(d) Plate glass (Indian) 5.5 mm thick (glazing area exceeding 84 sq dm of each pane). 17.36d
Providing and fixing beading to door and window chowkats of commercials hard wood such as hillock, champ, only (non-coniferous timber other than teak, conforming to I.S specification no. 1003, kiln-seasoned) iron screws fixed in position complete as per design and shape required. (a) 50 mm x 12 mm 17.53a
Supplying and fixing hydraulic door closer I.S.I mark, with necessary screws etc. complete (c) I.S.I designation no. II (size of door 851 mm to 1000 mm)(Make OZONE/UNIVERSAL/DORMA) 17.82c
Factory manufactured Solid Flush Door Shutter, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hotpressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (Merino, Greenlam, Century,Duro make only). (b) Decorative veneering with vertical grains or cross bands and face veneer on one sides teak face and on the other side commercial facing edges lipped with commercial hardwood with laminated core. (i) 25 mm thick Rate (493.00-11.85) = 481.15 17.93-17.18
Decorative veneering with vertical grain cross bands and face veneer on both sides teak facing and edges lipped with commercial hard wood with laminated core. (iii) 35 mm thick Rate (629.00-11.85) = 617.15 17.93 -17.18
Providing and fixing Aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS;733 and IS;1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. aluminum sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling C.P brass/stainless steel screws, all complete. Fixed portion (Anodized Aluminum transparent or dyed to required shade according to IS;1868, minimum anodic coating of grade AC 15) Bidders are advised to see the drawings as there are some slim/Thin sections for sliding Sections before bidding. 17.95 +17.96 note ii
Providing and fixing aluminum work for doors, windows, ventilators and portions with excluded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS;733 and IS;1285 fixed with rowel plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions hold fasteners, at top, button, and sides with required neoprene felt etc. aluminum sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including clear angle, aluminum snap beading for glazing/paneling C.P brass/stainless steel screws, etc complete, shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required including Aluminum fitting. Openable Portion (Anodized Aluminum transparent or dyed to required shade according to IS;1868, minimum anodic coating of grade AC 15) Bidders are advised to see the drawings as there are some slim/Thin sections for sliding Sections before bidding. 17.96 +17.96 ii
Providing and fixing 12 mm thick pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS;12823 grade 1 type II in paneling fixed in aluminum doors. Windows shutters and partition frames with c.p brass/stainless steel screws etc. complete. (a) Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side 17.97a
Providing and fixing glazing in aluminum door, windows, ventilator shutter and partitions etc. with pvc/neoprene gasket etc. complete (cost of aluminum snap beading shall be paid in the basis items ). (b) With float glass panes of 5.00 mm thickness 17.98b
Providing Aluminum jail of thickness 7mm thick with openings-75 mm X 75mm of including anodizing and fixing in frame with cost of screws etc. complete. 17.100
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. 18.12
Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights / depths / storeys / basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 18.22
Supplying and fixing glass panes including special metal sash putty of approved make. (b)Glass panes 4 mm thick 18.30b
Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the specified sections, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving ower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete. (a) Door and window frame of size 89 mm X 50 mm with 40 mm wide single rebate 18.34a
Door and window frame of size 76 mm X 38 mm with 25 mm wide single rebate 18.34b
Door and window frame of size 127 mm X 50 mm with 40 mm wide single rebate 18.34c
PUBLIC HEALTH (INTERNAL)
Excavation for pipelines running under pressure In trenches and pits, in open areas, where disposal,Of surplus earth is done alongwith the alignment Including trimming & dressing sides, leveling of beds of trenches to Correct grade, cutting joint holes, cutting trees and bushes, etc.,Refilling consolidation and watering of refill in 15 cm layers and Restoration of unmetalled or unpaved surface to its original condition, including the cost of dewatering of rain Water, diversion of traffic, night signals, fixing caution boards, watching, Fencing etc., and outside the town in ordinary soil:-(a) without timbering and shoring upto 1.5 metress depth 6.8a
Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness upto 6” (six inches) for passing drain pipe 4” (four inches) internal diameter and repairing the hole after insertion of drain pipe etc. including finishing complete so as to make it leak proof. 8.39b
Cement concrete 1:8:16 with stone aggregate 40mm nominal size in foundation and plinth. 10.28
Cement concrete 1 : 2 : 4 with stone aggregate 20 mm Nominal size in foundation and plinth. 10.41
Drilling and Tapping cast iron / D.I pipe lines of all diameters and screwing in ferrule and connections-Size of ferrule. (b)15 mm internal diameter of pipeline. 28.22
Cutting holes upto 23 cm square through brick work in cement walls for pipes and making good including repointing replastering and finishing according to existing finish where required. (i) 11.43 cm thickness of walls 28.24i
(ii) 22.86 cm thickness of walls 28.24ii
Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent limer mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2;4 slab 100 mm thick./C.C. topping 50 mm thick with 455 mm x 455 mm 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint coplete as per standard design. (c) Size 600 mm x 900 mm inside (with 455 mm x 455 mm cover and frame light duty singel weighing 20 Kg with R.C.C. slab). (a) Size 450 mm x 450 mm 29.84
(b) Size 450 mm x 600 mm 29.84b
(c( Size 600 mm x 900 mm 29.84c
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE LAVATORY SUITES ( With Full anti splash rim in VITREOUS CHINAWARE) size as give below ( to the approval of the Engineer-in-charge) including china plug for tap hole where necessary ; R.S. or C.I.BRACKETS for building into wall including painting; 32mm C.P.BRASS WASTE WITH C.P. brass chain and rubber plug; 15mm C.P.BRASS SCREW DOWN PILLAR TAP WITH jam nuts or couplings best design (as approved by the Engineer-in-charge) ALL FITTINGS BEST INDIAN MAKE and; to the approval of the Engineer-in-charge. ALL brass work chromium plated and COMPLETE in all respects INCLUDING cutting and MAKING GOOD THE WALLS, FLOORS AND PAINTING OF FITTINGS ETC. WHITE (ii) Size 530mm X 430 mm with one no. tap 30.42ii
Providing and Fixing in position best Indian make Pedestal Fittings of Viterous chinaware complete as required by the Engineer-in-charge. (i) White 30.44i
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE SHOWER WITH 15 OR 20 I/D IN-LET. (c) C.P brass with revolving joint. 30.66c
Providing and fixing in position best Indian make towel rails fixed in with rawlslugs embedded in walls with C.P. Brass screws, complete in all respect including cutting and making goods the walls etc. (a) 25 mm dia, C.P. Brass adjustable. (ii) 600 mm long. 30.68aii
Providing and fixing in position glass shelf fixed in with rawl plugs with C.P. Brass screws, complete including cutting and making good the walls etc. (a) with C.P. Brass brackets and guard rail. (i) 600mm x 125 mm .30.69ai
Providing and fixing in position best Indian make Soap dish fixed into wall with C.P. brass screws and complete in all respects including cutting and making goods the walls etc. (a) C.P. Brass (i) Soap dish Large.30.70ai
Providing & fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on absetos sheet ground fixed in postion by means of 4 Nos. chromium plated brass screws and washers over rubbers washers and rawl plug embeded in the wall or chromium plated brass clamps with C.P. brass screws (as required by the engineer-in-charge) complete including cutting and making good the walls etc. (a) Indian Make (i) 600 mm x 450 mm. 30.71ai
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). (a)Bib cock long body. 30.75
Bib cock 30.75c
Providing & fixing in position C.P. brass stop cock as approved by the engineer-in-charge. (a) 15 mm Stop COCK (i) Male and Female End 30.76a
Concealed Stop cock with flange 30.76aii
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE FLEXIBLE TUBE CONNECTION ( Make Viking ) (b) C.P Brass 15 mm x 450 mm 30.82b
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat not less than 5 mm of the approved design for fixing C.I. soil waste vent or anti pipes to walls complete in all respects. (a) for 100 mm interal diameter pipes. (a) for 100 mm interal diameter pipes. 30.88
(b) for 75 mm interal diameter pipes. 30.88ab
Providing & Fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm x 150 mm cast iron cover weighing approximately 7.26 Kg. and frame clear opening 300 mm x 300 mm and outside size 330 mm x 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:2:4, in coping black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm. (b) 100 internal diameter H.C.I. gull trap.30.144b
ESTATE SERVICES ROAD & PARKING
Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs. 6.6
Cement concrete 1 : 5 : 10 with stone aggregate 40 mm Nominal size in foundation and plinth. 10.34
Cement concrete 1 : 2 : 4 with stone aggregate 20 mm Nominal size in foundation and plinth. 10.41
Factory manufactured Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in Kerbs and the like items, indluding from work, placing and fixing in position, complete at the ground level. 10.77
Factory manufacture Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in tiles and channel ( SAUCER TYPE ) and the like items, indluding from work, placing and fixing in position, complete at the ground level. 10.78
Providing and laying 80 mm thick ISI Marked interlocking paver Blocks conforming to IS 15658:2006 / IRC: SP: 63-2004 of all shapes and colours in design mix cement M- 40 over a bed of 30mm thick fine sand complete in all respect.(PAVIT/NTC/UNISTONE/HINDUSTAN) as approved by Engginer-in-Charge. 10.159
First class brick work laid in cement sand mortar 1:4 in foundation and plinth. 11.4
First class brick work laid in cement sand mortar 1:6 in 1st storey upto 4 metre above plinth level. 11.7
Providing and laying Precast coloured chequered tiles of 20 mm thickness In ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings..(PAVIT/NTC/UNISTONE/HINDUSTAN) 14.45+Note
Fine dressed and rubbed red stone (from Agra ) 40 mm thick, set in 12 mm thick cement Coarse sand mortarin cement coarse sand mortar 1:3 includeing pointing with cement mortar 1:2 with and admixture of pigment to match the shade of stone. 14.56 c
Dholpur stone (Bansi Pharpur) 25 mm thick in wall facing (lining) laid in anypattern as specified on 12 mm thick cement coarse sand mortar 1:3 and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps,pins and dowels. Note : Light Pink. If some percentage of Red colour is required, same will be used at site in Combination. 14.60
Applying priming coat (Ist quality) with cement primer in all shades on newly plastered or concrete exterior surface. 16.25
Painting two coats of exterior acrylic emulsion paint(2nd Quality) 16.79
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. 18.12
Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights / depths / storeys / basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 18.22
ESTATE SERVICES PUBLIC HEALTH WORKS
Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation , including disposal of all surplus soil as directed within a lead of 30 Mtrs. 6.6
Excavation for pipelines running under pressure In trenches and pits, in open areas, where disposal,Of surplus earth is done alongwith the alignment Including trimming & dressing sides, leveling of beds of trenches to Correct grade, cutting joint holes, cutting trees and bushes, etc.,Refilling consolidation and watering of refill in 15 cm layers and Restoration of unmetalled or unpaved surface to its original condition, including the cost of dewatering of rain Water, diversion of traffic, night signals, fixing caution boards, watching, Fencing etc., and outside the town in ordinary soil:-(a) without timbering and shoring upto 1.5 metress depth. 6.8a
Centring and shuttering for faces of walls,partitions, retaining Walls, well steining and the like (vertical or battering) including attached pilasters, buttresses etc. 9.5
Centring and shuttering for sides and soffits of beams haunchings, girders, bressumers and lintels. 9.7
Shuttering for faces of concrete foundations and foundations beams (vertical or battering) 9.13
Cement concrete 1 : 4 : 8 with stone aggregate 20 mm nominal size in foundation and plinth. Note:- Surface should be smooth like floor so that water proofing treatment may be carried out easily. 10.38
Cement concrete 1:2:4 with stone aggregates 20 mm nominal size in foundation and plinth. 10.41
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- charge in foundation and plinth. Note: 1. Cement content considered in this item is @ 350 kg/cum. 2.In case cement content of the Design Mix is more than the specified in above items, nothing extra willbe paid for extra cement to be consumed. In case cement content of the design mix is less than the specified in above item, then less cement used as per design mix is recoverable separately as per base rates. 10.68
First class brick work laid in cement sand mortar 1:4 in foundation and plinth. 11.4
11.43 cm thick brick wall laid in cement sand mortar 1:4 without reinforcment in Foundation and plinth. 11.47
12 mm thick cement plaster 1:4 with cement rendring on plaster 1 mm thick. 15.5+15.75
Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights / depths / storeys / basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 18.22
Providing and fixing CAST IRON DOUBLE FLANGED SLUICE VALVES PN-1.6 MARKED WITH IS: 14846 including nuts & bolts marked with IS: 1363, Rubber sheet marked with IS:638 etc. carriage loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction of Engineer-In-Charge( Make AARKO,VENUS,LEADER,BIR,PANJA,UPADHAY).100 mm internal dia. 28.10
Supplying GI PIPES CLASS B MARKED WITH IS: 1239 IN 3.05 M LENGTH, their threading and welding with flanges(Heavy duty) on both sides, joining with nuts and bolts marked with IS: 1363, rubber gaskets, marked with IS: 638 JOINTING WITH PUMPING MACHINERY AND LOWING INTO TUBEWELLS and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-In-Charge. 50 mm internal dia. 28.52
Providing and fixing In BRASS/GUN METAL FERRULES BY DRILLING AND TAPPING CAST IRON/D.I/G.I PIPE LINES of all diametres nd making connections including carriage ,loading,unloadingetc. Complete in all respects to the satisfaction of Engineer-in-charge. 10mm i/d Ferrule. 28.54
Providing and fixing DUCTILE IORN DOUBLE SEAL MANHOLE COVERS AND FRAMES OF 610MM x 610MM with locking arrangement on clear water tanks including cost of setting in cement concrete 1:2:4 to correct alignment and levels including carriage, loading, unloading, etc. complete in all respects to the satisfaction of Engineer-in-Charge. 28.59
Providing and fixing steel bar embeded plastic steps of size 263mm x 165 mm of orange colour, conforming to specifications, in chambers, manholes etc. having minimum 3 mm thick polypropylene polymer conforming to IS:10910 encapsulated on 12 mm dia ribbed steel bars per IS:1786 complete in all respects. 29.28
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS:5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured and paid separately. (i) 100 mm Dia. 28.61i
Providing, lowering, laying, aligning, fixing in position and jointing at all level / depths DI standard specials plain / flanged / socketed confirming to IS-9523-2000 with rubber ring (EPDM / SBR) joints such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer (i) Upto 300 mm Dia.
CONSTRUCTION OF RECTANGULAR STANDARD BRICK MASONRY MANHOLE CHAMBERS to standard drawings on S.W. pipe sewers or other circular pipe sewers upto the required depth in 1.5 CEMENT SAND MORTAR, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 IN BENCHING, 12 MM THICK WATER TIGHT 1:2 CEMENT SAND PLASTER WITH A FLOATING COAT OF NEAT CEMENT AND FINISHED WITH 2 COATS of sodium silicate on interior surface where required, REINFORCED CEMENT CONCRETE SLAB 180 MM THICK FIXING 560 MM internal diameter C.I.MANHOLE COVER AND FRAME WEIGHT not less than 2.5 quintal PAINTED WITH 3 COATS OF BLACK BITUMEN PAINT, FIXING galvanised malleable IRON STEPS embedded in 1:2 cement sand mortar COMPLETE. The rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in0charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc.complete in all respect as approved by Engineer-in-charge. (ii) On 150 mm internal diameter pipe sewer. (a) for 1.20 meters depth below ground level 29.90
1.50 meters depth below ground level 29.90
1.80 meters depth below ground level 29.90
On 200 mm internal diameter pipe sewer. (a) for 1.80 meters depth below ground level 29.90iv
2.10 meters depth below ground level 29.90iv
2.40 meters depth below ground level 29.90iv
Providing, lowering, laying, cutting ( cut surface to be uniformly finished.) jointing with rubber rings marked with IS: 5382 and testing of SPIGOT AND SOCKETTED RCC NP2 MARKED WITH IS: 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handing, re-handing etc. complete in all respects to the satisfaction to the Engineer-in-charge. 400 mm Internal Dia Pipe 29.93
INTERNAL ELECTRICAL WORKS
Wires & Cables Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire. (d) Size 1.50 sqmm ( 48 / 0.20mm). 31.9id
Suply and erection of PVC copper insulated and sheathed 3-core circular flexible wire. (e)Size 2.50 sqmm ( 80 / 0.20mm). 31.9iie
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. (I) Size 50 mm x 50 mm x 6 mm. 31.13l
(L) Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. Make Indo Asian /Havels of Equilent etc as approved by Engineer-in-charge. (ii) SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.(1x36x1+1x18x1+24x20x5+12x1x5 =2514) 31.17aii
SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp. 31.17aii
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp. 31.17aiii
(M)Supply and erection of Fittings and Accessories. (vii)Call bell 220 / 230 volts A.C. bakelite with double coil. 31.18vii
Bakelite angle / straight button holder large size.( For tube Light & bracket Light & Mirror Lights) 31.18xi
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. .31.18xxvi
(Q) Earthing Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. 31.22iii
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. 31.22v
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . 31.22xi
Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required . 31.22xii
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material. 31.22xv
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . 31.22xvi
(R) Lightning conductor (a) COPPER Supply and erection of 20 mm x 3 mm thick lightning conductor copper tape fixed with suitable copper stapples of same size. 31.23vi
Supply and erection of copper tape 32 mm x 6 mm thick from earth electrode directly in ground and surface , fixed with suitable copper stapples of same size. 31.23vii
Supply and erection of 25 mm dia meter 1.5 metre long lightning solid coper rod tappered into a point at the top with 16 cm. X 16 cm x 3 mm thick copper base plate and necessary and bolts with washer. 31.23viii
Prioviding and fixing,testing joint made of 20mmx3mm thick copper strips 125mm long with 4 Nos. brass bolts and nuits, check nuts with washer complete. 31.23ix
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches & complete with necessary connections . 400 Sq. mm 3.5 Core Cable . (For incoming (2800,1900&1300Sqft) 31.25xxxv armoured
300 Sq. mm 3.5 Core Cable . (For interconnection2800, 1900&1300 & For incoming 800& 550Sqft) 31.25 xxxiv armoured
240 Sq. mm 3.5 Core Cable . (For interconnection of 800 & 550 Sqft) 31.25xxxiii armoured
35 Sq. mm 3.5Core Cable . (For Outgoing cables from the LT panel for Water Pump, Fire Pump & Lifts ) 31.25xxvi armoured
16 Sq. mm 4Core Cable . (For area lights outgoing cables) 31.25xl armoured
Supply and erection of suitable compression type brass cable glands for underground/ surface Cable. (vii) 300 Sq mm to 400 Sqmm Cable 3 to 3.5 Core . 31.28vii
240 Sqmm Cable 3 to 3.5 Core . 31.28vi
25 Sqmm to 50Sqmm Cable 2 to 4 Core . 31.28iii
10 Sqmm to 16 Sqmm Cable 2 to 4 Core . 31.28ii
AREA LIGHTING Supply and erection of 32 mm dia meter 1.5 metre long bracket ( B-Class ) making an angle of 10 to 15 degree with horizontal plane for mounting street light fitting fixing of GI bracket on wall with 2 Nos. , 32 mm x 3 mm thick MS clamps including the cost of cutting , welding of GI pipe complete with cement sand mixture , bolts and nuts etc. including necessary connections . 31.30III xv
Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, locking arrangemrnt , housed in wall , including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including painting and necessary connections . 31.30iv
(X) Miscellaneous . Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. (i) (a) 15 mm dia. 31.35ia
Supply and erection of caution notice plate in three languages. 31.35iii
Supply and erection of shock restoration chart in glass frame 31.35iv
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. (ix) (d) 16 sqmm . 31.35ixd
35 sqmm . 31.35ixf
240 sqmm . 31.35ixm
300 sqmm . 31.35ixn
400 sqmm . 31.35ixo
Supply and erection of cable rout marker made of 50cm long 10mm dia M.S Rod welded/revitted at the top with 10cm dia 5mm thick GI.plate inscribed with cable word on it, having a cross arm 30cm long of the same dia welded at bottom, in exiting trench45cm below the ground level 31.35xi
(A) PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. (b) Fan Point -Medium( Fan) 31.36b
Light Point - Medium. 2800 (Bracket Lights 31 +down lighter 23 +Mirror Light 6+Tube Lights 0+ Exhaust Fans 7 )=67x20=1340+ common bracket lights18 + common control lights 20=1378 1900(Bracket Lights 26 +down lighter17 +Mirror Light 4+Tube Lights 0+ Exhaust Fans 5 )=52x20=1040+ common bracket lights18 + common control lights 20=1078 1300 (Bracket Lights 20 +down lighter14 +Mirror Light3+Tube Lights 0+ Exhaust Fans 4 )=41x20=820+ common bracket lights18 + common control lights 20=858 800 (Bracket Lights 16 +down lighter14 +Mirror Light 2+Tube Lights 0+ Exhaust Fans 3 )=35x20=700+ common bracket lights18 + common control lights 20=738 550 (Bracket Lights 12 +down lighter6 +Mirror Light 1+Tube Lights 0+ Exhaust Fans 3 )=22x20=440+ common bracket lights18 + common control lights 20=478 31.36 ii b
Twin control light point with 2 way 5 amp. single pole switch-Midium point.(D/C Tube Lights)4x20=80+60+60+40+40 31.36 iiib
Light point without control- Medium point. 31.36iv b
Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell - Midium point 31.36 vi c
3 pin 5 amp. plug point including earthing the 3rd. pin etc with 1.5sq.mm PVC insulated copper conductor cable. -Short point.( With Multiple Power Sockets) 31.36 vii a
3 pin 5 amp plug point including earthing the 3rd. pin etc.with 1.5 sq mm PVC insulated copper conductor cable - Medium point.( Independent LP Sockets) 31.36 vii b
3 pin 5 amp. plug point including earthing the 3rd. pin etc with 1.5 sq mm PVC insulated copper conductor cable.- Long point.( IndependentLP TV sockets(2No Socket +1No Switch )+ Cable Socket) 5x20=100 31.36 vii c
3 pin 15 amp.plug point including earthing the 3rd. pin etc. with 4 sq mm PVC insulated copper conductor cable- Short point. (for Gyser Points with 15A switch on switch board)) 31.36viii b
3 pin 15 amp.plug point including earthing the 3rd. pin etc. with 4 sq mm PVC insulated copper conductor cable- Medium point. (for AC Points) 31.36 viii b
3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated copper conductor cable - Long point.(Power Plugs)14x20=280 31.36 viii c
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (i) Size 1.5 sqmm (3 / 0.81mm).For earthing/misc wiring 31.40 i
Size 2.50 sqmm (3 / 1.05mm).For Sub Main to SB with plug.63x10x3x1+34x10x3x20+29x10x3x20+24x10x3x20+18x10x3x20+17x10x3x20=. 31.40ii
Size 4 sqmm (7 / 0.85mm).For earthing with sub main to 4way TPN DB's 1 (2x15)=30mtr) 31.40iii
Size 6 sqmm (7 / 0.105mm).For earthing with sub main to 12/8way TPN DB's 2x15x2+ 20 (2x15)=660mtr) 31.40 iv
Size 10 sqmm (7 / 1.35mm).For sumain of TPN DB's 4way. 1(4x15)=60mtr 31.40v
Size 16 sqmm(7/1.70mm) for sub main of TPN DB's 12/8 way 2x15x2+20 (4x15)=1260mtr) 31.40vi
Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work.Make Indo Asian /Havels of Equilent. (v) 4-way, TP & N (Horizontal) (8+12) 31.41v
8-way, TP & N (Horizontal) (8+24) 31.40 vi
Moulded case Circuit breakers.(RCCB/ELCB) Supply and erection of double pole / Four pole Residual current circuit breaker ( RCCB / ELCB) suitable for operation on 240/415 V, 5 Hz. AC supply installed in existing sheet steel enclosure including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. Make Indo Asian /Havels of Equilent. (xiv) 40A / 415V 4P ELCB with 100mA senstivity. 31.42 c xiv
63A / 415V 4P ELCB with 100mA senstivity. 31.42 xvi
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. ( For telephone points) 20x50=1000 (a) 20 mm dia 31.44a
25 mm dia 31.44b
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect Make Indo Asian /Havels of Equilent etc as approved by Engineer-in-charge. (i)10 amp. 1 way switch (for LP with multiple socket+ Independent LP sockets+plug on SB + LCD sockets) 31.56i
10 amp. 2 way switch 31.56ii
20 amp. Switch(PP +AC+ Gyser) 31.56iii
10 amp. Socket (for LP with multiple socket+ Independent LP sockets+plug on SB + LCD sockets) 31.56iv
16 amp. Socket(PP + AC +Gyser) 31.56v
Bell push 31.56vi
Fan regulator 31.56vii
Call bell Ding-Dong ( Monitca ) 31.56viii
Blinking Plate 31.56ix
Pdg. and fixing GI concealed sheet metal boxes inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material requiered to complete the job in all respect Make Indo Asian /Havels of Equilent etc as approved by Engineer-in-charge (i) 1 & 2 module (for telephone sockets) 31.57 i
3 Modules ( for AC&Gyser Sockets) 31.57ii
4 Modules (for Misc ) 31.57 iii
6 Modules for (LP+PP)+LCD points 31.57 iv
8 Modules ( for room SB's +Computer Points) 31.57v
12 Modules( for Misc SB's) 31.57 vi
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends inspection boxes , iron hooks, cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work. (i) PVC pipe of 32 mm dia 31.58i
LT PANELS (2500mmx19000mmx350mm each panel) Supply, Installation, Testing and Commissioning of wall / free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable tray separating switches compartment and supporting suitable channel duly painted by 2 coat zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rising. the panel having PU / Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipments / switch wear. Transport acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The Panel will be complete with control wiring (Copper) and fuse protection. (Only outer area on all sides shall be measured).(2000x1600x600) (1.6x2x2+1.6x.6x2+2x.6x2=10.72 Sq.m 31.63
Supply and Fixing of copper bus bar duly tinned by means of SMC / DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with color coding heat shrinkable PVC insulation complete in all respect. (2.5x4x4.32=43.2KG/Mtr for 750A BUS) & ( 2.5x4x2.0=20KG/Mtr for 500A BUS) 31.64
Supply and Fixing of rotary handle for ON / OFF operation of existing MCCB in the LT panel including fixing the same in position with all labour and material to required to complete the job in all respect.Category 'A' :- Larson and Tubro,English Electric Co, Siemens (i)Rotary Handle up to 125 Amp., MCCB 31.66i
Rotary Handle above 125 Amp., MCCB 31.66ii
S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in charge of work. HDPE 63/50 mm outer dia / inner dia 31.67i
Supply and erection of module case circuit breaker single pole/04 on wall on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (v) 4 Pole MCCB 100 AMP 31.69v
4 Pole MCCB 200 AMP 31.69vi
4 Pole MCCB 300 AMP to 400AMP 31.69vii
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/Channel and making necessary connection complete in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. (i) 2 pair telephone wire 31.78i
S/E/T/C of RG-11 COAXIAL TV cable in existing PVC pipe /channel complete in all respect with all labour and material required to complete the job in all respect. 31.79
S/E/T/C of Cat-6/WiFi cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect. 31.80
ESTATE SERVICES ELECTRICAL WORKS (FIRE DETECTION AND ALARM SYSTEM)
Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire.Cable 2C x 1.5 Sq mm Copper 31.9 ID
Suply and erection of PVC copper insulated and sheathed 3-core circular flexible wire.Cable 3C x 2.5 Sq mm Copper 31.9 IIE
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends,inspection box and all other material requiredto complete the job in all respect to the entiresatisfaction of Engineer-in-Charge of work. (b) 25 mm dia. 31.44B
STREET LIGHT
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections,digging and refiling of trenches. (xi) 16 Sq. mm 4 Core Cable . 31.25XL ARMOURED
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (ii) Size 2.50 sqmm (3 / 1.05mm). 31.40ii
Supply and Erection of Hot Dip Galvanized octagonal pole of 3 mm thickness, with base plate including cost of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galvanized pole complete with door locking arrangement, Terminal plate consisting of 2 nos. 100 Amp., 4 pole neutral links including connection etc. with suitable connecting arrangements for 2 No. MCB's / Kit-Kat including cost of R.C.C 1:1, 5:3 for foundation of size 0.7 M x 0.7 M x 1.8 M with minium 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm C.C for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. (i) 7 Mtr. Long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220 mm x 225 mm x 12 mm. 31.68i
Erection of street light fitting on the pole including the cost of petty material required ( irrespective of height / length of bracket ). Pole above 4.5 metres but upto the height of 7 metres . 31.30III xiv b
(Q) Street Light Poles Earthing Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . 31.22i
Extra for using salt and charcoal / coke for pipe earth electrode as required. 31.22ii
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . 31.22xvi
FIRE FIGHTING BOOSTING PUMP
Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire.Cable 2C x 1.5 Sq mm Copper 31.9 ID
Suply and erection of PVC copper insulated and sheathed 3-core circular flexible wire.Cable 3C x 2.5 Sq mm Copper 31.9 iie
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material requiredto complete the job in all respect to the entiresatisfaction of Engineer-in-Charge of work. (b) 25 mm dia 31.44b
HSR ITEMS (BASED ON DSR)
CIVIL WORK ABOVE PLINTH LEVEL
Providing and fixing machine moulded aluminium covering of approved pattern& design, made out of machine cut aluminium sheet and machine holed forreceiving dash fastener, over expansion joints on vertical surfaces/ceiling floors,the fixing on plate in one row on one side of joint only shall be done with stainlesssteel dash fasteners of 8 mm dia and 75 mm long bolt including providingaluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mmcentre to centre including drilling holes in the receiving surface and providingexpandable plastic sleeves in holes etc. complete as per direction of Engineerin-charge.21.7.1 Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to requiredshade according to IS: 1868, Minimum anodic coating of grade AC 15) 21.7.1
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. (Material shall confirm to ASTM 6063). 5.44.1
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias, skirting/dado and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.1.1 : AGARIA White : Area of slab upto 0.50 sqm (a) First Storey 8.2.1.1
Second Storey 8.2.1.1
Third Storey 8.2.1.1
Fourth Storey 8.2.1.1
Fifth Storey 8.2.1.1
Sixth Storey 8.2.1.1.
Seventh Storey 8.2.1.1.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias, skirting/dado and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.2.1 : Granite of of colour matching to granite of staircase or as the case may be : Area of slab upto 0.50 sqm (a) First Storey
Second Storey 8.2.2.1
Third Storey 8.2.2.1
Fourth Storey 8.2.2.1
Fifth Storey 8.2.2.1
Sixth Storey 8.2.2.1
Seventh Storey 8.2.2.1
Providing & Fixing 1.00 mm thick decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (Merino, Greenlam, Century,Duro make only). 9.127.2
Providing and fixing panic bar / latch (Double point) 1500 mm long fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. 9.139
Providing and Fixing Stainless Steel (SS 304 Grade) Friction Hinges(300 X 19 X 1.9mm) to the side/Top Hung Aluminium Windows of approved quality with necessary SS screw etc complete in all respects. (Hettich, EBCO, Hefele) 9.148.3
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge .9.161
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified at CBRI Roorkee and ARAI Laboratory, approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge. 9.162
Providing and fixing glazing with clear fire resistant glass panes 6mm thick of approved brand, having minimum 120 minutes fire resistance in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible.The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. 9.164
Agaria White Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (a) First Storey 11.23.3
Second Storey 11.23.3
Third Storey11.23.3
Fourth Storey 11.23.3
Fifth Storey 11.23.3
Sixth Storey 11.23.3
Seventh Storey 11.23.3
Second Storey 11.56.1
Third Storey 11.56.1
Fourth Storey 11.56.1
Fifth Storey 11.56.1
Sixth Storey 11.56.1
Seventh Storey 11.56.1
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete On steel work 13.52.1
Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer withscratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 13.72
Forming (15 mm wide and 15 mm deep ) groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge. 13.73.1
Melamine polishing on wood work (one or more coat).including 2 coats of wood filler on new work. To the entire satisfaction of Engineer in charge/monitoring committee. 13.114
Providing & Applying high quality acrylic modified resin based texture paint of Dholpur/Red sand stone ( Smooth Stone series) Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm complete including scaffolding up to 6 storey building as the direction of Engineer -in-Charge. ( Make Heritage, Spectrum, SKK ) 22.24a
INTERNAL PUBLIC HEALTH WORK
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 17.2.1 : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing of Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work Concealed/Exposed on walls.(Make Supreme/Finolex/ Prince). Note:- Pipes and fittings with "Flow Gaurd" technology as per CTS Standard dimensional ratio (SDR) :11 (Class 1) Pipes at a working pressure of 27.6 Kg / sq.cm at 23 degree celsius using moulded Chlorinated Polyvinyl Chloride (CPVC) fittings i.e. Tees, Elbows, Couplers, Unions, Reducers , etc. incl transitions fittings connection between CPVC and Metal Pipes / GI Pipes with Brasss adaptors (both Male & Femal End) Confirming to ASTM D 2846 with only CPVC solvent cement Confirming to ASTM F-493. (ii)20 mm internal diameter of pipeline 18.8.2
Providing and fixing GI PIPE B class(JINDAL HISAR/TATA make) in complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. Internal work Exposed on walls. (i) 20 mm internal diameter of pipeline 18.10.2
25 mm internal diameter of pipeline 18.10.3
32 mm internal diameter of pipeline 18.10.4
50 mm internal diameter of pipeline 18.10.6
Providing and fixing gun metal gate valve( heavy pattern ZOLOTO/SANT/KARTAR make) with hand wheels, on G.I pipelines laid in inside/outside building including threading, testing complete in all respects. (i)25 mm internal diameter 18.17.1
20 mm internal diameter 18.17.1a
32 mm internal diameter 18.17.2
50 mm internal diameter 18.17.4
ESTATE SERVICES ROAD AND PARKING)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete On steel work 13.52.1
ESTATE SERVICES PUBLIC HEALTH
Providing and Fixing 50 mm dia G.I Pipes (B Class)(JINDAL HISAR/TATA make) Complete with Gi Fittings including trenching and refilling etc. complete in all respects. 18.12.6
LANDSCAPING & HORTICULTURE Including maintenance for 03 years ( BASED ON CSR)
Supplying at site of work well decayed farm yard manure, from approved source, including screening and stacking. 32.1
Maintenance of lawn with fine grass mowing with the help of shrubs master for the 1st year including watering etc. 32.7
Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed fary yard manure. Size of pit 0.75X0.75 x0.75 m deep 32.10
Planting flower beds including digging and refilling of beds with excavated soil and FYM fertilizer and insecticides planting of sapling at 30cm distance of plant to plant and row to row. Area for Seasoal Flowers 32.23aii
Maintenance of flower beds for one year including 27 No. waterings @ 4 waterings in the months of March, April, May and June, 2 No irrigations each in the months of February, October, November and December and one irrigation each in July, August and September 32.29
Providing and fixing steel tree guards having 3 Nos. legs of angel iron size 25x25x3mm 1.8 mtr. height, 3 Nos. rings of MS bars 8mm thickness 60 cm. dia and fixing of wire mesh size 3.81x7.62 cm. around the angel iron complete in all respects. 32.31
N.S ITEMS
CIVIL WORK BELOW PLINTH LEVEL
Carriage of excavated Earth, Laying in layers and compaction for Disposal upto any lead complete in all respects within the New Campus of LUVAS as per direction of Engineer-in-charge
Providing and laying two courses of water proofing treatment with bitumen felt consisting of first courses of blown tyye bitumen grade 85/25 applied hot at 1.20 kg per sqm of area for each course, second course on surface in foundation, felt type 3 grade-I (Hessian base self finished bitumen felt) including preparation of surface complete.
Earth Filling under floors with Tibba sand taken from outside the campus area with all lead & lift, including loading, unloading, laid in 25 cm layers including campaction upto 98% of SPD with sheep foot roller/ soil compactor, watering compensation of earth etc. complete in all respect with entire satisfaction of Engineer in charge. Note :- 1. Density to be checked layer wise and recored in the register. 2. Note:- This rate is without compensation. If the agency bring a certificate duly certified by revenue authority that the contactor campensate the land owner, payment on this account will be made as (HSR 6.4 item+ CP applicable) on the date of tender.
Providing and laying VDC ( Vaccum Dewatered Concrete) pavement in Stilt portion of Design mix M-30 with minimum cement content 340 Kg/Cum with design mixed concrete from automatic batching plant as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. making provision for contraction/ expansion, construction & longitudinal joints (6 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with Polysulphide Pour Grade sealent ( Make SIKA ) including providing 125 micron Polythene sheet ( Transparent) on surface area below the VDC complete as per specifications and directions of Engineer-incharge. (Item of dowel bars / tie bars to be paid separately under item of HSR 18.22 ). (Note:- Rate includes all items as mentioned above.)
CIVIL WORK ABOVE PLINTH LEVEL
Providing and fixing Double Charged vitrified tiles of size 600 x 600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with White cement slurry mixed with pigment to match the shade to tiles. Note:- 1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO. (Note: Double Charged Vitrified tiles shall be used.) 2. Tile Shall be provided with 3mm thick groove and filled the same with Epoxy Grout of reputed brands such as pidilite, laticrete, ferrouscrete & valendure as per IS specifications 15477-2004. 3. Tiles will be covered after execution and will remain covered till the completion of work to avoid any damage to tiles. (Note :- In toilets antiskid vitrified tiles will be used. The contractor should quote the rate as per nomenclature above. Nothing extra will be payable on any account) (a) Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing and fixing Double Charged vitrified tiles of size 600 x 600mm of approved make in skirting/dados laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with White cement slurry mixed with pigment to match the shade to tiles. Note:- 1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO. (Note: Double Charged Vitrified tiles shall be used.) 2. Tile Shall be provided with 3mm thick groove and filled the same with Epoxy Grout of reputed brands such as pidilite, laticrete, ferrouscrete & valendure as per IS specifications 15477-2004. (a) Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Extra rate for using size 800 x 800 Double charged tiles instead of 600 x 600 mm of vitrified tiles in both flooring and skirting.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours , laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Note: 1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO. 2. Combination pattern of floor and wall tiles will be approved by University and no claim will be entertained (a)Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing and fixing Ist quality ceramic glazed wall tiles 300 X 600 MM with highlighters conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades , or any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Note: 1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO. 2. Combination pattern of floor and wall tiles will be approved by University and no claim will be entertained. 3. Nothing Extra will be paid for using Highlighters on walls. (a)Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing & fixing Stainless Steel Fittings Heavy Duty (Chrome Finished) to doors,window,cupboard etc. (Grade 304) with nuts & screws etc complete.(as per sample approved by Engineer-in-charge). (i) S.S tower bolt (8" long)
Providing & fixing Heavy Duty. S.S tower bolt (6" long) with nuts & screws etc complete. (Grade 304) ( Note :- Toilet shutter will also be provided tower bolt 6" long)
Providing & fixing Heavy Duty S.S Sliding bolt (200mm x 16 mm dia) with nuts & screws etc complete.(Grade 304)
Providing & fixing heavy Duty S.S Handle bolt (5" long) with nuts & screws etc complete.(Grade 304)
IS: 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete.Size 125 x 64 x 2.50 mm
S.S Rear Magnetic Door Stopper.
150 mm floor S.S front Door stoppers (Godrej or equivalent make) with rubber cushion screws etc to suit shutter thickness complete.
Supply and fixing Modular Kitchen with 700 mm high & 300 mm deep Storage cabinates on walls and 820 mm high & 575 mm deep storage/rack under counter Shelves as per drawing/design approved by Engineer-in-charge (make ALCON/ALNO/NOLTE). Drawing attached with BOQ. Wall/Base Carcass made of 18mm Both Side Laminated Postlam BWP Grade Plywood with Edgeband on exposed sides & Back Panel of Both Side Laminated Compact Laminate. Shutters made of 18mm Both Side Laminated Postlam BWP Grade Plywood Edgeband Shutter with 2mm Edgeband on exposed sides with Soft Close Hinges (Make ‐ Ebco/Hettich/Hafele). Double Wall Drawers (DWD) made of 18mm Both Side Laminated Postlam BWP Grade Plywood with Edgeband on exposed sides & Back Panel of Both Side Laminated Compact Laminate with Soft Close Double Wall Drawers telescopic channels (Make ‐ Ebco/Hettich/Hafele). Kitchen has to be provided with acessories like Cutlery Tray(1 Pcs) Dustbin (1 Pcs), Detergent Rack ‐ (1 Pcs) (Make ‐ Ebco/ Hettich/ Hafele), 256mm Linear Handle on shutters/Drawers(Make ‐ Sparx/ Ebco/ Hettich), PVC Leg and 3 Dowel 100 mm, Predrilled Dowel in All Carcass with CNC Machine for Strength & Precsion (Make ‐ Rehau/ Ebco/Hettich/Hafele), Stainless sink with drainage board (Neelkanth Make),PVC Skirting 100 mm,Finish Silver (Make ‐ Rehau/ Ebco/Hettich/Hafele) . Cracass has to be Jointed with Minifix, Wooden & Cabinet Connectors Predrilled Dowel in All Carcass with CNC Machine for Strength & Precsion (Make ‐ Ebco/ Hettich/ Hafele) & Camar Wall hanging Bracket with provision for Horizontal and Vertical alignment (Made in Italy) complete in all respects as directed/upto to the entire satisfaction of Engineer-in-charge. (Note :- Colour to be decided by the University ) (a) 2800 Sft Unit ( Kitchen Size 3.50m x 5.21 m)
1900 Sft Unit (Kitchen Size 3.16 x 4.57 m )
1300 Sft Unit (Kitchen Size 2.56 x 3.02 m )
800 Sft Unit (Kitchen Size 2.76 x 1.84 m )
550 Sft Unit (Kitchen Size 1.70 x 3.13 m )
Providing and fixing Factory manufactured Pre-laminated (1mm laminated on both sides) Solid Flush Door Shutter, having uniform thickness of 25mm with smooth finish and moisture content 10 to 12% with water absorption of 2%,climate stable, warp and bend free as certified by IS-2202 with 1mm HPL conforming to IS - 2046 with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hotpressed, conforming to I.S. 2202 part I and II, fixed in position, screws, chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (Merino, Greenlam, Century,Duro make only).(Colour and company to be decided bt the University) .
Providing and fixing Factory manufactured Pre-laminated (1mm laminated on both sides) Solid Flush Door Shutter, having uniform thickness of 35mm with smooth finish and moisture content 10 to 12% with water absorption of 2%,climate stable, warp and bend free as certified by IS-2202 with 1mm HPL conforming to IS - 2046 with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hotpressed, conforming to I.S. 2202 part I and II, fixed in position, screws, chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (Merino, Greenlam, Century,Duro make only).(Colour and company to be decided bt the University) .
Factory-manufactured wire gauze door and windows shutters of commercial hard wood such as hollock, champ only conforming to I.S. specification no. 1003, kiln seasoned with 100 mm wide vertical styles, 150mm wide lock rail 200 mm wide bottom rail, and combination of ( SS 304 G mosquito mesh ( 120 G or 140 G designations) and Aluminium Mesh with opening 10mm x 10mm 1.6 mm thick ) including cost of iron hinges, screws, chock /cleats, stops nails etc, complete fixed in position ( excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position.) (a) 30 mm thick
Supply and fixing factory manufactured Modular Wardrobre (600mm deep) as per drawing/design approved by Engineer-in-charge (make ALCON/ALNO/NOLTE). Drawing attached with BOQ. Carcass made of 18mm Both Side Laminated Postlam BWP Grade Plywood with 0.8mm Edgeband on exposed sides. Shutters made of 18mm Both side laminated HDHMR with 2mm Edgeband on exposed sides with Snap on Sensys Soft Close Hinges (Make : Ebco/Hettich/Hafele). Drawers made of 18mm Both Side Laminated Postlam BWP Grade Plywood with 0.8mm Edgeband on exposed sides with Soft Close Telescopic channels (Make ‐ Ebco/Hettich/Hafele). Wardrobe has to be included with Oval Anodized Hanging Rod with Brackets, PVC Leg & Skirting(Silver Finish), Linear Handle on shutters/Drawers (Make ‐ Rehau/Sparx/ Ebco/ Hettich), Cracass has to be Jointed with Minifix, Wooden & Cabinet Connectors Predrilled Dowel in All Carcass with CNC Machine for Strength & Precsion (Make ‐ Ebco/ Hettich/ Hafele) & Camar Wall hanging Bracket with provision for Horizontal and Vertical alignment (Made in Italy) complete in all respects as directed/upto to the entire satisfaction of Engineer-in-charge. (Note :- 1. Colour to be decided by the University ) 2. Only front elevation measurement of wardrobe shall be measured for Payment.
Providing and Fixing wire mesh in sliding aluminium french / casement windows with a combination of ( SS 304 G mosquito mesh ( 120 G or 140G designation) and Aluminium Mesh with opening 10mm x 10mm 1.6 mm thick ) including EPDM / Neoprene gaskit complete in all respects.
Providing and Fixing superior quality hardware fittings for Sliding Aluminium French Windows i.e ( 1 no. Sliding Lock, 1 No. Locking Plate, 2 No. Twin Roller, 1 No. Anti-Theft Block, 1 No. Anti-Strike Block.) with necessary SS screw etc complete in all respects.(Make KINLONG/GIESSE/ALUALPHA)
INTERNAL PUBLIC HEALTH WORKS
Providing and fixing in position "B" Class SWR Ring fit Pipes single socket as per IS : 13592 including jointing with seal ring confirming to IS:5382 complete with specials/Tee's/Bends as per IS :14735 as required at site complete as per instruction of Engineer in Charge. (a)110 mm Dia. O/D
90 mm Dia. O/D
Providing & Fixing UPVC SWR floor traps with 75 mm i/d outlet. I.S.I. marked of the self cleaning design including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc. minimum depth of water should be 50 mm with a minimum seal of 50 mm. complete in all respects.
Providing & Fixing Stainless steel Jali ( 100 mm dia) 304 G for Floor trap including cutting and making good the walls and floors complete in all respects.(Make VIKING)
Providing and fixing in position European Type Extended Wall Hung WC Suite (ECS-WHT-351S) of Size:385x665x76 mm,with PP soft close seat cover, Hinges, Fixing Accessories and Accessories Set, Cistern (ECS-WHT-201) with cistern fittings including all fixtures complete in all respects of ESSCO(Jaquar ) make. (White)
Providing & fixing Table Top wash basin ( ECS-WHT-933) with Size: 435 x 375 x 195mm including all fixing acessories with waste coupling (ALE-544-FT) complete in all respects of ESSCO(Jaquar ) make. (White)
Providing & fixing Under Counter oval shape wash basin ( ECS-WHT-601) with Size: 530 x 445 x 195mm including all fixing acessories with waste coupling (ALE-544-FT)complete in all respects of ESSCO(Jaquar )
Providing and fixing in position Two Way Bib Cock with Wall Flange (APR-1010-41) including all fixtures complete in all respects of ESSCO(Jaquar ) make.
Providing and fixing in position Angular Stop Cock with Wall Flange (APR-1010-53) including all fixtures complete in all respects of ESSCO(Jaquar ) make.
Providing and fixing in position Single Lever Basin Mixer without Popup Waste With 450mm Long Braided Hoses (APR-1010-11B) including all fixtures complete in all respects of ESSCO(Jaquar ) make.
Providing and fixing in position Overhead Shower ø125mm Round Shape Single Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System (EOS-542-A) and Shower Arm (ALE-536-A) including all fixtures, complete in all respects of ESSCO(Jaquar ) make.
Providing and fixing in position Health Faucet (ABS Body) with 1.2 Meter Long PVC Tube & Wall Hook (ALE-ESS-583) including all fixtures, complete in all respects of ESSCO(Jaquar ) make.
Providing and fixing in position Sink Cock with Swinging Spout (Wall Mounted Model) with Flange (APR-1013-47N) including all fixtures, complete in all respects of ESSCO(Jaquar ) make.
Providing and fixing in position Wall Mixer 3 in 1 System with Provision for both Hand Shower and Overhead Shower complete with 115mm Long Bend pipe, connecting lengths and wall flange(without Hand & Overhead Shower) (APR-1012-81) including all fixtures, complete in all respects of ESSCO(Jaquar ) make.
Providing and fixing in position Stainless Steel Jet Spray with 1 meter PVC tube (ALE-547) including all fixtures, complete in all respects of ESSCO(Jaquar ) make.
ESTATE SERVICES ROAD & PARKING
Construction of berms, shoulder embankment, and completion of formation width and Earth filling under floors with Tibba sand, excavation and cutting of earth in all kind of soils including dressing the bank, side slope to given level sand templates after breaking of clouds, including the cost of rolling and watering all allowances for labour hardness wetness including all lead and lift, compensation for earth taken from private land, fields etc. and compacted to meet requirement of table 300-2 of MoTR&H specification clause no. 305 and to the entire satisfaction of the engineer of the work conforming ot PWD specification 6.2 and 6.3 and 3.2 and the other specification 1990 Ist edition.
Providing and laying 100 mm thick granular sub base consisting of filter layer confirming to Table 400.1 Grading - III of MoRT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No. 401 of MoRT&H specifications. Note: - 1.Only crushed metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Material and operation manufacturing shall be approved by engineer.
Providing and laying 100 mm thick granular sub base consisting of drainage layer confirming to Table 400.1 Grading - VI of MoRT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No. 401 of MoRT&H specifications. Note: - 1.Only crushed metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Material and operation manufacturing shall be approved by engineer.
Providing and laying VDC ( Vaccum Dewatered Concrete) pavement in Road and Parking of design mix M-35 with minimum cement content 350 Kg/Cum with design mixed concrete from automatic batching plant. , using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading with CC Pavement Paver and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 6 mm wide x 65 mm deep joint) in contraction joints and (10 mm wide x 200 mm) deep expansion joint at every 30 m lenth of road ) by groove cutting machine, providing and filling joints with Polysulphide Pour Grade sealent ( Make SIKA ), complete all as per direction of Engineer-in-charge(Item of dowel bars / tie bars to be paid separately under item of HSR 18.22 ).
ESTATE SERVICES PUBLIC HEALTH WORKS
Carriage of excavated Earth, Laying in layers and compaction for Disposal upto any lead complete in all respects within the New Campus of LUVAS as per direction of Engineer-in-charge
Providing and laying two courses of water proofing treatment with bitumen felt consisting of first courses of blown tyye bitumen grade 85/25 applied hot at 1.20 kg per sqm of area for each course, second course on surface in foundation, felt type 3 grade-I (Hessian base self finished bitumen felt) including preparation of surface complete.
Providing and laying DWC Pipe SN4 Class for sewage disposal including lowering,cutting,jointing,and testing including the cost of jointing material and all accessories complete in all respects to the entire satisfaction of Engineer-in-Charge. (MAKE:- Supreme/Prince/ Astral) (a) 150 mm Dia Pipe
200 mm Dia Pipe
SITC of 2 Hp openwell submersible pump Vertical Head : 46 meters, Duty Point : 27 Meters / 220 LPM Suction & Discharge Pipe size : 1.5" including all electrical fitting i.e starter, Wire/Cable Required & Automation charges complete in all respects.(KIRLOSKAR/ CROMPTON/FLOTECH)
INTERNAL ELECTRICAL WORKS
(FAN AND LIGHTS)
SITC 60W LED Flood Light. The Fixture should be Made of pressure diecast housing with TOUGHNED GLASS diffuser and indivisual LEDs with secondary optics with IP 66 protection. PF>.95, System Wattage LED 60W with Minimum 110 lumens/watt in 5700k. The Fixture should be of Makes :-BAJAJ EDGE (169799 BRTFG 60W LED) /PHILIPS/GE/OSRAM/CGL/HAVELLS.
Supply of energy efficeint AC ceiling fan with 5star rating complete in all respect of approved quality by the Engineer on charge of work. Make Havells, Orient, Khaitan. Ceiling Fan 48" (1200mm)
S/E of heavy duty industrial type of Exhaust fan 900 RPM including the cost of making hole in the wall or providing and fixing MS Sheet 14 SWG with painting as per satisfaction of engineer-in charge. (Commercial / industrial model only). (Make Orient/Havells/Crompton/Orient/Havells Size 300mm sweep, 900 RPM
3Phase Flush mounting Multifunction Meter Model Nova-LCD Display Cat No- WM30KFC3CRS
SITC Copper Bonded Earth Rod with 17.2mm Dia and 3mtr long with 2 Bags Backfill 99.9% electrolyte grade copper.
Supply installation testing & Commissioning of push ON/OFF type 25A modular type motor starter switch (white color) for AC's including the cost of petty material required to complete the job upto entire satisfaction of Engineer-in-charge. (Make:- Schneider/Crabtree/Athena)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Make Indo Asian /Havels of Equilent etc as approved by Engineer-in-charge (a)Wiring TV socket point (one module) csr 33.01 IX A
Wiring Telephone socket point RJ11 (one module)
Wiring LAN/WiFi socket point RJ45 (one module)
ESTATE SERVICES ELECTRICAL WORKS DSR
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. ( To be installed in Kitchen of Each flat) 17.1.1
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/ recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.( To be installed in corridoor of each floor) 17.1.3
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. ( To be installed in corridoor of each floor) 17.1.5
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. ( To be installed in corridoor of each floor) 17.1.6
FIRE ALARM & DETECTION SYSTEM (FIRE EXTINGUISHERS) csr
Providing and fixing of fire EXTINGUISHER ABC Powder type( Stored Pressure)as per IS-15683 complete with all accessories as per manufacturers specification ISI mark complete in all respect. 28.124
2Kg Capacity 28.124A
4Kg Capacity 28.124B
Providing and fixing of fire EXTINGUISHER CO2 type as per IS-15683 complete with all accessories as per manufacturers specification ISI mark complete in all respect.V28.125
2Kg Capacity 28.125A
4.5Kg Capacity 28.125B
Supply, Installation, Testing and commissioning of Glow Type EXIT/Stair /Emergency Exit Sign Board as finalized by Engineer In Charge, photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastenerwith 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.
CCTV - NON SCHEDULED ITEMS
Supply Installation Testing & Commissioning of 4MP IP Network bullet camera including cost of petty material required to complete the work upto the entire satisfaction of engineer in charge having following techincal specifications
Image Sensor : 1/3" 4 megapixel progressinve scan CMOS sonsor or better. Effective pixels : 2688(H)x 1520(V)or better. Electronic shutter : Auto/manual 1/3(4) 1/100000s. Scannng system: Progressive S/N Ratio More than 50dB Min IR LED Length>70m IR Leds : 2 or better Day/Night : Auto(ICR)/Color/B/W Back light compensation : BLC/HLC/WDR(120DB) White balance : auto/natural/street lamp/out door/manual Motion detection : Off/On(4Zone, rectangle) Focal Lenght :3.6mm Region of Interest :Off/On(4Zone) Video compression :H.265+/H.265 Resolution : 4mp Streaming capability : 3 digital zoom : 16x Bit rate: H.265 :14 9984 kbps Network ethernet :RJ 45 (10/100Base-T) Protocol: HTTPs. : TCP :ARP: RTSP : RTP : UDP :SMPT :FTP : DHCP :DNS : DDNS :PPPOL : IPv4 v6 : Qos : UPnP:NTP: Bonhour 802.1xMulticast : ICMP IGMP:SNMP compatibility :ONVIF SD Card :Min 128GB SD Card support Working environment :-30 c to +60c less than 95% RH (no condensation) Ingress protecton: IP67 Vindal resistance : IK10 Audio interface : 1/1 channel in/out Alarm : 1 channel In : 5MA 5 VDC, 1 channel out 300 mA 12VDC Inelligence (IVS): Triwire, Instrusion object abandoned/Missing. Advanced intelligent functions : Face Detecion Certification : CE ,FCC,UL Make : DAHUA/HYUNDAI/PELCO/HONEYWELL
Supply Installation testing & commissning of Video Management Recorder including cost of petty material required to complete the work up to the entire satisfaction of Engineer In charge having following technical specifications:
Main Processor: Quad-Core Embedded Processor or better. Operating System: Embedded LINUX IP Camera Input:-32 Channel or More. Two-Way Talk: 1 Channel input 1 Channel output/RCA. Interface:>/ 1 HDML,>/1VGA. Compression : H.265/H.264 Resolution:-8MP, 6MP,5MP,4MP,3MP, 1080P,1.3MP,720P etc.Record rate :-200Mbps Record Mode: Manual, Schedule (Regular,MD (Motion Detction ), Alarm, Analytics), Holiday Stop. Video Detection: Motion Detection Video Loss and Tampering Multiple VCA Events Alarm input : >/ Channel Relay out put:>/ 2 Channel Search Mode: Time/Date, Alarm, MD/ Smart Search Back Mode : USB Device/Network/EASTA Device Network Interface: 4RJ-45 Ports(10/100/1000Mbps), Ethernet port:- 1 Independent 1000Mbps Ethernet Ports Network Function: HTTP,HTTPs.TCP/IP,IPv4/IPv6,UPnP,RTSP, UDP,SMTP,NTP,DHCP,DNS,IP Filter, PPPoE,DDNS,FTP,Alarm Server,IP Search etc. User Access:>/ 128 users Smart Phone: iPhone, Ipand, Android Interoperability: ONVIF 2.4, CGI Conformant Internal HDD: Internal min 2 SATA HDD port, upt 6TB HDD support per Slot USB Ports Operating Conditions:-10' C ~ +55` C Certifications: CE, UL, FCC Make:DAHUA/HYUNDAI/HONEYWELL/ PELCO
Supply Installation testing & commissning of Outdor 4*4 Box Including cost of petty material required to complete the work upto the entire satisfaction of Engineer In charge having Make :-STRONGER/MOLEX/AMP Item required for out side camera connector protection
Supply, Installation, Testing and comissioning of 8 port Layer -2 managable supply instalation Testing and comissioning of 8 port Layer -2 managable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe port for copper fiber uplink 20gbps switching capacity 14.88mbps forwarding performance maximum power consumption minimum 85 watt Make:Cisco/Ericsson/Juniper
Supply Installation Testing & Commissioning of 6TB servilance hard disk including cost of petty material required to complete the work up to the entire satisfaction of Engineer In Charge Make: WD-PURPLE/SEGATE.
Supply Installation Testing & Commissioning of 12U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Comrack / HCL
Supply Installation Testing & Commissioning of 32" LED Monitor, HDMIPort. Resolution:-1920 x 1080 (FHD) , Back light TYPE- LED (edge), Viewing Angle degree - 178x178, Life span (hrs) 30,000, Brightness (cd/m2)- 200, or better, Make: Sony/Panasonic/Samsung
Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/Havells
Supply Installation Testing & Commissioning of CAT 6 UTP Cable. Make: PANDUIT/R&N/SYSTIMAX
Supply and erection of PVC pipe25mm dia ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. Make: BEC, AKG, Kalinga / Diplast
Supply Installation Testing & Commissioning of 1 KVA UPS with 1 hr back up: 1KVA ONLINE UPS TRUE ONLINE - DOUBLE CONVERSION, IGBT BASED MAKE: EMERSON LIEBERT MODEL: GXT MT LB WITH 1 PHASE IN / 1 PHASE OUT WITH ACTIVE INPUT POWER FACTOR CORRECTION 0.99 INPUT VOLTAGE (110 - 280V AC) INPUT FREQUENCY 40Hz - 70Hz OUTPUT 200/208/220/230/ 240V AC - 1% THDv <3% ON LINEAR LOAD AND <6% ON NON LINEAR LOAD WITH OVCD AND LCD DISPLAY, SMF BATTERIES BANK OF 42AH/12VOLT*3NOS with RACK AND INTERCONNECTORS. MAKE APC/ LIBERT/ Emerson
LIFTS - NON SSCHEDULED ITEM
Supply Installation testing & commissioning of Passenger (884 Kg, 13 persons.) Machine Room Less Gearless Elevator with 3 year free comprehensivie warranty/maintenance period from the date of completion to be supplied and installed in accordance with the following technical specifications: Make:- OTIS/KONE/SHINDLER/JOHNSON/MITSUBISHI
Sr. No Description Specification (A)- IMonospace 01) Designation of Lifts Passenger 02) No. Of Elevators as shown in quantity coloum – Model – IMSS008 or equivalent 03) Type and Capacity 13 Passenger – 884 Kgs 04) Speed 1 M/Sec 05) Drive V3F 06) Location of M/c Room Not Required 07) Travel 17 m approx. 08) Serving , 0, 1,2,3 and 4 09) No. Of Stops 5 10) Well Size Available 1950 mm (W) x 2450 mm (D) 11) Power Supply 415 V Three Phase 50 Cycles Ac 12) Auxiliary Single Phase 220v 50 Cycles Ac 13) Car size 1100 mm (W) X 2000 mm (D) X 2200 mm {H} 14) Pit Depth 1500 mm 15) Head Room 4200 mm
16) Car Enclosure Model IMSS 008 or equivaltent Car Ceiling RL75 LED Lighting Ceiling Car Panels SS Hairline Finish Panels. Car Flooring Recess of 20mm will be provided. Flooring in customer scope. Car Illumination LED Lights. 17) No. Of Entrance One Location Front 18) Car Entrance Automatic Centre Opening Power Door in SS Hairline Finish 19) Door Safety Full Height Infra-Red Curtain. 20) Landing Entrance Automatic Centre Opening Power Door in SS Hairline Finish. 21) Clear Opening 900mm (W) X 2000mm (H) 22) Control Full Collective Simplex 23) Indicators KDS 90 D & P indicators in White color Car KDS 90 Display & Position Indicators Landing KDS 90 Display & Position Indicators 24) Handrail 01 on rear side. (S.S) Other Features FAN : 1 No. with 300 MM Sweep Flooring : Granite Flooring (Superior Quality CAT EYE or Equivalent) as per approved Design , duly approved by Engineer - in - charge Lights : Diffused LED Lighting in car Indicaters : Digital Direction and Position Indicators in both car and at all landings, Call Registration: Red Battery Operated Emergency Light with Rechargeable Battery Battery Operated Emergency Alarm with Rechargeable Battery Emergency Alarm at the main building KDS 300 Square buttons Motor compatible for 180 starts per Hour Door Open, door Close and alarm button in COP Landing doors fire rated for 01 Hour Nudging Partial Height Mirror on rear wall Full Height car operating panel Facia plate 2 Phase fireman drive, fireman's switch at the main landing. (In case fireman drive is activated the elevator will come to the main landing and open the door.) Additional pressure sensing device Load weighing device (Audio visual over load indicator in the car for better safety Full height Infra-Red curtian (Highly sensitive safety device for safe entrance & Exit of the passengers in to the car) Pit ladder (Ensure safety of the maintenance personnel) Emergency light, intercom, and alarm with maintenance free rechargeable battery operation. (Ensure passenger comfort and safety in case of emergency) +6% to -10% Volt. Fluctuation withstand capacity (Ensure lift operation in low voltages) Over Speed Governer (Electo-Mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction) Automatic rescue device with manual rescue lever (To rescue the passengers in case of emergency --- This device will bring the car to the nearest floor automatically and will open the doors. I.e it will resume operation from same floor. Daily automatic brake testing Steel Ropes (Ropes of Longer life and lower maintenance will be used) Car Door Lock ---Additional Safety Features
Supply Installation testing & commissioning of Passenger (1020 Kg, 15 persons.) Machine Room Less Gearless Elevator with 3 year free comprehensivie warranty period to be supplied and installed in accordance with the following technical specifications: Make:- OTIS/KONE/SHINDLER/JOHNSON/MITSUBISHI
Sr. No Description Specification (A)- IMonospace 01) Designation of Lifts Passenger 02) No. Of Elevators 01 – Model – IMSS008 03) Type and Capacity 13 Passenger – 884 Kgs 04) Speed 1 M/Sec 05) Drive V3F 06) Location of M/c Room Not Required 07) Travel 17 m approx. 08) Serving , 0, 1,2,3 and 4 09) No. Of Stops 5 10) Well Size Available 1950 mm (W) x 2450 mm (D) FINISHED All Side Brick Walls, Entrance Lintel and Sill should be in RCC at all landings. 11) Power Supply 415 V Three Phase 50 Cycles Ac 12) Auxiliary Single Phase 220v 50 Cycles Ac 13) Car size 1100 mm (W) X 2000 mm (D) X 2200 mm {H} 14) Pit Depth 1500 mm 15) Head Room 4200 mm
16) Car Enclosure Model IMSS 008 Car Ceiling RL75 LED Lighting Ceiling Car Panels SS Hairline Finish Panels. Car Flooring Recess of 20mm will be provided. Flooring in customer scope. Car Illumination LED Lights. 17) No. Of Entrance One Location Front 18) Car Entrance Automatic Centre Opening Power Door in SS Hairline Finish 19) Door Safety Full Height Infra-Red Curtain. 20) Landing Entrance Automatic Centre Opening Power Door in SS Hairline Finish. 21) Clear Opening 900mm (W) X 2000mm (H) 22) Control Full Collective Simplex 23) Indicators KDS 90 D & P indicators in White color Car KDS 90 Display & Position Indicators Landing KDS 90 Display & Position Indicators 24) Handrail 01 on rear side. Other Features FAN : 1 No. with 300 MM Sweep Flooring : Granite Flooring (Superior Quality CAT EYE or Equivalent) as per approved Design , duly approved by Engineer - in - charge Lights : Diffused LED Lighting in car Indicaters : Digital Direction and Position Indicators in both car and at all landings, Call Registration: Red Battery Operated Emergency Light with Rechargeable Battery Battery Operated Emergency Alarm with Rechargeable Battery Emergency Alarm at the main building KDS 300 Square buttons Motor compatible for 180 starts per Hour Door Open, door Close and alarm button in COP Landing doors fire rated for 01 Hour Nudging Partial Height Mirror on rear wall Full Height car operating panel Facia plate 2 Phase fireman drive, fireman's switch at the main landing. (In case fireman drive is activated the elevator will come to the main landing and open the door.) Additional pressure sensing device Load weighing device (Audio visual over load indicator in the car for better safety Full height Infra-Red curtian (Highly sensitive safety device for safe entrance & Exit of the passengers in to the car) Pit ladder (Ensure safety of the maintenance personnel) Emergency light, intercom, and alarm with maintenance free rechargeable battery operation. (Ensure passenger comfort and safety in case of emergency) +6% to -10% Volt. Fluctuation withstand capacity (Ensure lift operation in low voltages) Over Speed Governer (Electo-Mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction) Automatic rescue device with manual rescue lever (To rescue the passengers in case of emergency --- This device will bring the car to the nearest floor automatically and will open the doors. I.e it will resume operation from same floor. Daily automatic brake testing Steel Ropes (Ropes of Longer life and lower maintenance will be used) Car Door Lock ---Additional Safety Features
STREET LIGHT
SITC 45W LED Street Light. The Fixture should be Made of pressure diecast housing with TOUGHNED GLASS diffuser and indivisual LEDs with secondary optics with IP 66 protection. PF>.95, System Wattage LED 45W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-BAJAJ EDGE (169799 BRTFG 45W LED) /PHILIPS/GE/OSRAM/CGL/HAVELLS.
SITC of LED Bollard integral decorative LED bollard with opel acrylic and IP 65 Protection Bajaj TULIP 111284 BGBOM 650 9W LED/Crompton MAYA III LBLA3-10-CDL make complete in all respect up-to entire satisfaction of Engineer-in-Charge of the work.
FIDDER PILLER BOX Supplying , Installation, testing and commissioning of front and back openable, double door outdoor feeder pillar not less than 800 mm x 500mm x 300 mm depth fabricated out of M.S. sheet of thickness not less than 2 mm having inside door with cut out for operating accessories mounted after opening front and slanting top suitably over hang on all sides, ventilator louvers with wire mesh, earthing bus & stud base mounting angle frame of size 45 mm x 45 mm x 5 mm thick, and concrete / brick foundation cable entry knock out, locking arrangement, rubber gasket suitable for providing & fixing the following switch gear and accessories and 100 Amp TPN aluminium Busbar, including connection etc. as required. A) Incomer : - i) 60-100 AMP, 4 pole, 10 KA, MCCB i/c Rotary Handle( Similar to M/s Legrand DRX100) - 1 No. B) Outgoing :- i) 40 Amp 3P & N MCB 'C' Series - 3 Nos. ii)32A 3Pole contactors 3No Legrand CTX 40 iii) Analogue 24hrs time switch ( Legrand cat no.Micro Rex QT31 daily) iv) Danger notice plate - 1 set v) Phase indicating lamp (R,Y,B) - 1 set vi) 2.0mm thick FP with 100Amp,4 strip Alu Bus Bar ( 0.80 x 0.50) vii) 45x45x5mm angle iron frame with CC foundation etc etc complete in all respect.
Supply & Erection of single bracket made of 40mm dia G.I pipe B class ISI 1.50mtr. Long with collar pipe (GI) 75mm dia 30cm Long top covered with ornamental cap duty welded painted 2coats of aluminum paints on bracket and golden paint of ornamental cap including the cost of labour and petty internal etc. complete in all respect up to the entire satisfaction
FIRE FIGHTING BOOST PUMP (Based on DSR Fire & Wet Riser)
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automati coperation and consisting of following, complete in all respects, as required: (Terrace Pump 900 lpm at 35 m Head). (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325 with suitable Electric starter. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. DSR 4.1
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 7.1 :- 25 mm dia. DSR 7.1
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/ Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 9.1:- Single headed Gunmetal 80mm
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with ronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :( KARTAR/CASTLE/LP) 11.5:- 100mm dia.
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : (KARTAR/CASTLE/LP) 12.1 :- 25/40 mm dia.
80mm DSR 12.4
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. DSR 13
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 14.5 100mm dia. DSR 14.5
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 16.1 :- Gun Metal ends (15m long) DSR 16.1
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 17.1 :- 30.0 m Length DSR 17.1
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 18.1 :- Gun Metal DSR 18.1
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 19.1 :- 2 way-100 mm dia M.S. Pipe DSR 19.1
Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. DSR 20
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. DSR 20
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 23.1 :- 100 mm dia. DSR 23.1
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 24.2 :- 100mm Dia
Supplying installation testing and commissioning of standard firemans axe with heavy insulated rubber confirming to IS 936 complete in all respect. CSR 116
Hose cabinet made of 16 SWG M.S sheet with glass front door - complete with hinges, handle, locking arrangement, recessed key provision and painting. The size shall be 750mm x 600mm x 250mm to accommodate 2 Nos. of hoses of length 15 m long, one branch pipes with nozzle with necessary clamps etc as approved by the Engineer Incharge. CSR 117C
N.S LANDSCAPE Note : The sucessful bidder will hand over horticulture works on the date of completion. He will maintain the horticulture work through out the defect liabilty period and will keep horticulutre works in healthy conditions throughout DLP. In Case any plant becomes dead, he will replace it with health plant. On the clearance of DLP, number of plants and area of grass will remain same as entered for payment purpose.
Supplying at site of work De - oiled Neem-Cake duly packed in used gunny bags.
Supply and Planting of plants along the roads and Lawns as per Drawing (i)Chorisia Speciosa Height 5 to 6 ft
Bougainvillea Height 5 to 6 ft
Delonix Regia Height 5 to 6 ft
Grevillea Robusta Height 5 to 6 ft
Seasonal Flower Beds Golden Durranta
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid