Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
21 Apr 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE
EDC II FATEBAD
BP WORK
2022_DVVNL_686950_1
T 04
Open Tender
Miscellaneous Works
Lump-sum
180 days
FATEHABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
DVVNL
₹16,000
22 Apr 2022
16 Apr 2022
21 Apr 2022
16 Apr 2022
21 Apr 2022
16 Apr 2022
30 days
carriage of following from 132 Kv taj Agra to 33 Kv S/s through the Kachha and pakka road incluading the work of its loading and unloading at the respective ends incluading arrangement of labour T&P carrier etc. requiered for proper comletion of work (Distance approx 40-70 Kms)
PCC Pole 8.5/9
11 KV 3x120 / 3x185 / 3x300 sqmm XLPE cable
Line material viz arial buch conductor/Weasel Conductor/Dog, G.I. earth wire, cross arm angle, channel, insulators, Pin insulater, clap and all other material reqriied at site.
Erection of single pole on 8.5 Mtr long PCC poles, including fixing of accessories for HT/LT line as per RESPO manual and as per direction of Engineer Incharge.
Erection of stays in 1:4:8 ratio cement, sand and stone ballast, its tighting, binding, nozelling etc of stay wire with stay and stay clamp of pole as per site requirement.
Fixing of earthing rod as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work
Laying, stringing, sagging, binding and jumpering etc of following conductors for construction of 11 KV Line/LT as per RESPO norms.
ACSR Weasal Conductor
Laying of 3x120/3x185/3x300 sqmm 11 KV XLPE cables by making required loop (at a distance of 4 mtr) including excavation of all work as per site requirement.
Mounting of 3x70/3x120/3x185/3x300 sqmm 11 KV XLPE cables on double pole and all other work as per site requirement.
Providing and Fixing/filling of heat shrinkable cable boxes, indoor and outdoor complete work in all respect.
opening of 33 kv both side jumpers and opening of 11 kv cable connections of existing 5 MVA power T/F placed on plinth at various 33/11 kv S/s kurgawa ten opeing of radiators, coservator tank, cutting the earth strips of T/f body and neutral using gas/etectirc cutter removing the T/f from plinth and placing at suitable safe place inside/outside the S/s premises/switchyard.
Dismantling of existing 11 kv XLPE cale 3*300 sqmm form cale trench coming in the way of shifting 5 kva T/f
Dismantling /breaking of earthing of body and neutral at two places with the help of ga cutter and its reconnecing by using MS flat 65*6mm with the help of Arx welding after replacement of T/F
installing of 10 KVA T/F on plinth in the switchyard after its draining from outside the switchyard, in proper alignment and direction as per instruction of supervising engineer.
fixing of radiatores, conservation tank and topping up of transformer oil in newly placed 10 MVA transformer as per RESSPO & Making of 33KV and 11 KV jumpers and connections.
Re-laying of above dismantled cable 3*300 sqmm 11KV XLPE power cable including the work of brick laying filling sand and earth and leveling at 33/11 Kv S/s as per Respo norms.
Fixing & grouting of cable joist and making the cable connections from 11 KV/33KV side of the 10 KVA tranformer with comple work.
connecting the earthing strip of 10 MVA tranformers with body & neutral bushing with bracket of MS Channel 100x50x6mm in L Shape grouting with stone ballast of Size 300x300x900m including plastering the same and welding of MS Strip from boring point to neutral bushing including welding works
received back 05 mva T/F form site to store
Received back old and damaged conductor 1288 Mtr and 11 KV XLPE cable 3x 120, 3x185 100 mtr to 33/11 S/S
CHAUHAN ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .