Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹2.1 L+₹9,228 (4.62%)Rejected-Finance HNO 365 STREET NO 12 TALAB TILLO JAMMU RISHI TRADING CO TALAB TILLO ROAD OPP FRIENDS LANE JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹2.1 L+₹13,550 (6.78%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
12 Sept 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
ELECTRICITY URBAN DISTRIBUTION CIRCLE, BUNGLOW NO.-9, OLD POWER HOUSE COLONY, RAILWAY STATION ROAD, GORAKHPUR
WORKS UNDER DEPOSIT SCHEME
2023_PVVNV_834369_1
26/EUDC(G)/2023-24
Open Tender
Electrical Works
Lump-sum
365 days
AREA OF EUDD-II GKP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SUPERINTENDING ENGINEER EUDC
₹2,000
9 Oct 2023
4 Sept 2023
13 Sept 2023
4 Sept 2023
12 Sept 2023
4 Sept 2023
Amount
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
PCC pole 8.5 meter long
STP pole 11 meter long
STP pole 9 meter long
ACSR Dog Conductor
ACSR Weasel Conductor
Aerial Bunch Conductor
11 KV Cross arm
11 KV Disc insulator with fitting
11 KV Pin insulator with fitting
11 KV Top Channel
11 KV Dropper Angle
11 KV SS Base Channel
11 KV T -off channel
11/0.4 KV, 25/63/100 KVA (Capacity may can vary)
Stay with 5 Kg. wire with all fitting complete
Earthing Complete
11 KV TPMO set
11 KV Fuse set
LT PVC Cable (size may can vary)
LT Three Phase Distribution box
The excavation of 2 No foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of double Pole with fixing of necessary clamps & accessories (Top Channel, Dropper Angle etc.) as per required. All required materials such as Holding clamp/STP clamp, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). Making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
Erection of single PCC Pole 8.5 mtr long All required materials such as Holding clamp/LT clamp/F Bracket, Nuts & Bolts off size etc will be provided by the contractor.
Erection of single STP 11/9 mtr long All required materials such as Holding clamp/LT clamp/F-bracket, Nuts & Bolts off size etc will be provided by the contractor.
Supply of following material/fitting complete in all respect :-
LT Piercing connector
Clamps for LT Distribution box with Nut & Bolts
Dead end clamp insulated
Suspension Clamp insulated
LT Cable 1X35 sq mm
Laying, stringing, sagging, binding and jumpering of conductor for LT/11 KV Line with providing and fixing of LT Clamps/other clamps, Shackle insulator, F Bracket and nuts &bolts off size by the contractor as per required.
ACSR Dog Conductor
ACSR Weasel Conductor
Aerial Bunch Cable
Painting of Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Fabrication, erection, commissioning & Testing of 25/63/100 KVA T/F on Double Pole/Plinth with all accessories including make its LT and HT connection. All neessary materials such as Al. lugs, Z clamp will be supplied by the Contractor. (Capacity may vary)
Chemical earthing of Transformer (Body+Neutral) as per IS Code 3043 - 1987 specification (Materials will be provided by contractor)
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Erection of 11 KV D.O. Fuse set
Erection of 11 KV TPMO
Rishi Trading Co.
M/S SHUKLA TRADERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .