Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 UDYAM WB 13 0098535 | MURSHIDABAD | WEST BENGAL | 742237 | ₹3.3 L | L1 | Accepted-Finance Due to Lowest |
| 2 | L2₹3.3 L+₹331.02 (0.10%)Rejected-Finance | ₹3.3 L+₹331.02 (0.10%) | L2 | Rejected-Finance Due to 2nd Lowest |
| 3 | L3₹3.3 L+₹364.12 (0.11%)Rejected-Finance | ₹3.3 L+₹364.12 (0.11%) | L3 | Rejected-Finance Due to 3rd Lowest |
| 4 | L4₹3.4 L+₹6,984.56 (2.11%)Rejected-Finance | ₹3.4 L+₹6,984.56 (2.11%) | L4 | Rejected-Finance Due to 4th Lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified and Shortfall Documents are not submitted by the Bidder |
Tender Value
₹3.3 L
EMD Value
₹6,620
Closing Date
15 Aug 2026, 2:00 pmClosed
The AE, Uluberia ESD, PWDte
PWD Campus, Gangarampur, Uluberia, Howrah, WB, Pin-711316
Arrangement of Compound Lighting along with the allied Electrical Installation works within the campus of Amta RH, Howrah. RN- 24002703, Project ID- HF262750919S000
2026_WBPWD_5017633_1
WBPWD/AE/UESD/eNIT-03 of 2026-2027
Open Tender
ELECTRICAL WORKS ORG
Percentage
Amta Rural Hospital, Amta
Please refer Tender documents.
9 documents required · 9 mandatory
₹6,620
Office of the AE_UESD_PWDte
11 Sept 2026
30 Jul 2026
18 Aug 2026
31 Jul 2026
15 Aug 2026
5 Aug 2026
3 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC OF COMPOUND LIGHTING SYSTEM | |||||
| 2 | Supplying, installation, Testing & Commissioning of 90 W Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy ≥135 lm/Watt : | 17 | Each | 4,534 | ₹77,078 |
| 3 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. | 14 | Each | - | - |
| 4 | Supplying, installation, Testing & Commissioning of 200W Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10%- 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy ≥135 lm/Watt | 2 | Each | 8,739 | ₹17,478 |
| 5 | Fixing only Flood light fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required | 2 | Each | 218 | ₹436 |
| 6 | Supply and Fixing SMC Junction Boxes of dimension (250x200x105)mm with IP 67 protection (Sintex / Hensel )make for compound light fabricated With 1 no 4pole DMC 32A terminal stud and 1no 6A 10KA C curve SP MCB (make-Legrand/ABB/Siemens/L&T) Mounted directly on wall surface by suitable fastner. | 16 | Each | 1,205 | ₹19,280 |
| 7 | Supply & Erection of 1.5 Mtr. long 80 mm dia G.I. pipe pole (ISI - Medium) with pole cap & base plate in C.C. (6:3:1) foundation of dimension 600x600x750 mm having on the roof of the building after chiping of the roof incl. 3 mm thick net cemented finish and providing G.I. earth bolt after making drilled hole etc. on pole incl. two coats of aluminum paint over one coat of RO primer as per G.S.(Jindal- ISI–M/ Bhusan-ISI-M/TATA-ISI-M) | 3 | Each | 2,652 | ₹7,956 |
| 8S & F of arm header assembly fabricated from 40 mm dia G.I. pipe (ISI-M) of 1.5 Mtr. long rigidly welded with 100 mm dia G.I. pipe (ISI-M) of 0.3 Mtr. Long at an angle of 15 degree with horizonrtal axis incl. S&F 3 nos. 1/2" MS jam nut each with 1 no. 1/2" dia. through bolt and painting the entire assembly. | |||||
| 8.01 | Single Arm | 3 | Each | 1,350 | ₹4,050 |
| 9 | Supplying & Fixing GI water proof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint | 3 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.51 MB
2911.pdf
Tender Documents • 1.86 MB
BOQ_5087955.xls
BOQ • 1.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .