Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L1 | Accepted-AOC OK | |
| 2 | L2₹27.1 L+₹2.6 L (10.8%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹27.5 L+₹3.0 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹27.6 L+₹3.1 L (12.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹28.5 L+₹4.0 L (16.4%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹47.2 L
EMD Value
₹94,400
Closing Date
13 Mar 2020, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
OUTSOURCING SERVICES FOR SEWAGE INSTALLATION, WATER SUPPLY INSTALLATION, INCINERATOR AND OTHER ALLIED WORKS AT CABINET SECTT UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2020_MES_325094_1
GE/BH-62/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE E/M BASE HOSP DELHI CANTT
Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value works annual turnover, working capital, fixed assets. No recovery outstanding in any govt dept security clearance etc.
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹94,400
Yes
31 Mar 2020
14 Feb 2020
16 Mar 2020
14 Feb 2020
13 Mar 2020
28 Feb 2020
Amount
Outsourcing services of water supply and fire pumping installation round the clock including Sunday/ Holiday by deploying skilled operator to operate installed machinery as per under given details complete all as specified and as directed:- Shift Duty (a) First Shift - 0600 hrs to 1400 hrs - One Skilled pump operator. (b) Second shift - 1400 hrs to 2200 hrs - One Skilled pump operator (c) Third shift - 2200 hrs to 0600 hrs - One Skilled pump operator. Details of Plant/Machineries to be operated (a) Centrifugal Pump with motor 125 HP - 01 No (b) Centrifugal Pump with motor 100 HP - 03 Nos (c) Centrifugal Pump with motor 60 HP - 03 Nos (d) Centrifugal Pump with motor 15 HP - 02 Nos (e) Centrifugal Pump with motor 12.5 HP - 03 Nos (f) Centrifugal Pump with motor 10 HP - 01 No (g) Centrifugal Pump with motor 7.5 HP - 02 Nos (h) Mono block Pump with motor 3 HP - 01 No (j) Jockey Pump with motor 15 HP - 03 Nos (k) Diesel Engine140 BHP, 680 ALU - 01 Nos (l) Sluice/butterfly valves (m) Electrical Control Panel of Pump Motor Note:- Diesel for operating Fire Engine shall be provided by the user.
Out sourcing services of Sewage installation on all working days (including Sunday/Holiday) in MS bldg and new CRF workshop by deploying skilled operator to operate electrically driven 3 phase, 50 Hz, AC sewage pumping system along with control of all mechanical device such as sluice valves, foot valves, NRVs etc. The installation to be operated in shift (8 Hours per shift) as mentioned below complete all as specified and as directed:- Shift Duty (a) First Shift - 0600 Hrs to 1400 Hrs with One skilled operator. (b) Second Shift - 1400 Hrs to 2200 Hrs with One skilled operator. (c) Third Shift - 2200 Hrs to 0600 Hrs with One skilled operator. Details of Plant/Machineries to be operated SEWAGE INSTALLATION OF MS BUILDING (a) 12.5 HP motor with pump complete-01 No. (b) 10 HP motor with pump complete-07 Nos. (c) Sluice/butterfly valves (d) Electrical Control Panel of Pump Motor EAST AND WEST SEWAGE INSTALLATION OF CRF (a) 5 HP motor with pump complete-04 No. (b) 3 HP motor with pump complete-02 No. (c) Sluice/butterfly valves (d) Electrical Control Panel of Pump Motor
Out sourcing services on all working days (including Sunday/Holiday as and when required and as directed by the concerned JE E/M) of thermax type paralytic incinerator Gas fired type for burning highly combustible waste like papers, Wooden boxes rags etc having maximum moisture contents up to 25%. The capacity of incinerator 150-185 Kgs per hour complete with primary and secondary burning chambers, burners, combined combustion & educator air fan, educator mechanism, electrical control panel and other accessories like chimney, gas cascade/cylinder, MS ducting pipe line, operating valves, electric accessories, cables etc complete all as specified and directed. The installation to be operated in General shift (8 Hours per shift) as mentioned below complete all as specified and as directed:- Shift Duty (a) General Shift - 1000 Hrs to 1800 Hrs with One skilled operator Details of Plant/Machineries to be operated (a) Gas Fired Incinerator of Capacity 150 - 185 Kgs Per hrs.. (b) Operation of gas fixing bank of 2 x 10 cylinder with control valves on both rows. (c) Electrical Control Panel (d) Combustion Fan Blower 5 HP (e) Burner Motor 0.5 HP
Note:- For Item No 1 to 3 (i) The estimated cost of the work in respect of BOQ Sr item Nos 1 to 3 (as based on minimum wages rates issued vide central/state) is Rs 19,70,000.00. If the quoted amount is found less than the estimated cost of Sr item No 01 to 3 of BOQ and tender of lowest bidder is considered for acceptance, then the lowest bidder will have to deposit FDR in favour of Accepting officer for the difference in estimated cost and Accepted amount in respect of BOQ Sr item No 1 to 3 within 30 days from date of acceptance. In case the said FDR is not submitted within 30 days the amount in question shall be recovered from contractor’s first RAR/Final bill whichever is earlier. However the FDR/recovered amount shall be released to the contractor after satisfactory completion of work. Attention is further invited added that when the amount of said recovery mentioned herein above is less than the amount of performance security as indicated under Clause 02 on page 04 of CA and Clause 12 on page 11 of CA, no FDR is required to be submitted for quoting less rate against BOQ Srl Item Nos 01 to 03. However if the amount of performance security is less than the FDR to be submitted for less quoting rate, the difference of performance security amount and FDR amount(for less quoting rates) shall be deposited by the lowest bidder (whose tender is accepted) in the form of FDR for difference amount over and above performance security within 30 days from the date of Acceptance.
(ii) The Operator shall be ITI qualified in concerned trade or shall have minimum 05 years experience in operation of water supply Installation/fire fighting Installation/LPG or PNG fired Incinerator/Sewage Installation/Forced ventilation. (iii) Contractor shall submit the nominal roll and qualification certificate of operator with in 15 days of acceptance. After that period a sum of Rs. 500/- per shift per installation shall be recovered. (iv) The staff deployed shall not leave the installation under any circumstances before handing over to Next shift duty operator otherwise penalty @ Rs. 500/- per shift per day shall be recovered from the contractor. (v) Contractor shall ensure attendance of all operators shift wise and Suitable Reliever to be provided during off shift operator if any operator found absent from duty a sum of Rs. 1000/- per shift shall be recovered. (vi) Contractor shall submit the payment proof i.e. passbook of bank account/Bank statement at the time of submission of RAR.
(vii) The payment of contractor's employee shall be made through nationalized bank account of individual and the proof of transaction and the contractor shall submit the same with bank account pass book of employees and own Bank account statement within 15 days of acceptance otherwise a recovery shall be made a sum of Rs 200/- per shift per employee from the contractor's dues. (viii) Police Verification of the employees shall be provided by the contractor. (ix) Contractor shall arrange their staff to run the installation in Saturday, Sunday/Public Holiday. (x) Sufficient T&P shall be arranged and kept in installation. (xi) Shift shall be of 08 hours starting from 0600 to 1400 hrs, 1400 to 2200 hrs and 2200 to 0600 hrs. (xii) Contractor shall be responsible for watch and ward of installation round the clock 24 hours. Any loss of damage to the plant equipment installed and Govt. property in the E/M installation premises shall be made good / born by the Contractor. Rate quoted by the Contractor shall deemed to be included on above Schedule. (xiii) All operator shall wear proper uniform, failing which a recovery of Rs 200/- per shift shall be recovered. (xiv) The contractor shall provide of all the necessary stationery such as Attendance Register, Periodical Maintenance Register, log book etc to the operator for maintenance the plant running record. (xv) The periodical cleaning/ routine checking/testing shall be carried out by the contractor for efficient and smooth functioning of the installations. (xvi) All consumable items like grease, gland packing, nuts, bolts, washers and any other minor parts or any other related welding/grinding work required for smooth and noiseless functioning of installation deemed to be included in quoted rates.
M&L for periodical maintenance of water supply installation in MS bldg for daily, weekly, monthly, quarterly, half yearly for under mention machineries complete all as specified and as directed:- (a) Centrifugal Pump with motor 15 HP - 02 Nos (b) Centrifugal Pump with motor 12.5 HP - 03 Nos (c) Centrifugal Pump with motor 10 HP - 01 No (d) Centrifugal Pump with motor 7.5 HP - 02 Nos (e) Mono block Pump with motor 3 HP - 01 No (f) Sluice valves/butterfly valves/NRV/Foot valves & water supply pipe lines in the installation. (g) Electrical Control Panel of Pump Motor
M&L for periodical maintenance of fire fighting installation in MS bldg for daily, weekly, monthly, quarterly, half yearly for under mention machineries complete all as specified and as directed:- (a) Centrifugal Pump with motor 125 HP - 01 No (b) Centrifugal Pump with motor 100 HP - 03 Nos (c) Centrifugal Pump with motor 60 HP - 03 Nos (d) Jockey Pump with motor 15 HP - 03 Nos (e) Diesel Engine Pump 680 ALU - 01 Nos (f) Sluice valves/butterfly valves/NRV/Foot valves & fire fighting pipe lines in the installation. (g) Electrical Control Panel of Pump Motor
M&L for periodical maintenance to under ground sewage installations located at East and West side of the MS building for the following machineries complete all as specified and as directed:- East and West Sewage installations of MS building: - (a) 12.5 HP motor with pump complete-01 No. (b) 10 HP motor with pump complete-07 Nos. (c) Sluice valves/butterfly valves/NRV/Foot valves and connected pipe lines in the installation (d) Electrical Control Panel of Pump Motor
M&L for periodical maintenance to under ground sewage installations located at East and West side of the new CRF building for the following machineries complete all as specified and as directed:- East and West Sewage installations of new CRF building: - (a) 5 HP motor with pump complete-04 No. (b) 3 HP motor with pump complete-02 No. (c) Sluice valves/butterfly valves/NRV/Foot valves and connected pipe lines in the installation. (d) Electrical Control Panel of Pump Motor
M&L for periodical maintenance to forced ventilation installed at New CRF building and D block basement for the following machineries complete all as specified and as directed:- (a) Induction Motor 40 HP coupled with DIDW blower - 01 (b) Air Handling Unit 60000 CFM - 01 (c) Air blower for ventilation of Ac plant room - 03 (d) Air Washer - 03 (e) Air Washer Pump 1.5 HP - 03 (f) Electrical Control Panel - 03 (g) Ventilation tower pump motor 5 HP - 02
M&L for periodical maintenance to Gas fired incinerator installed at MS building for the following machineries complete all as specified and as directed:- (a) Gas Fired Incinerator of Capacity 150 - 185 Kgs Per hrs.. (b) Electrical Control Panel (c) Combustion Fan Blower 5 HP (d) Burner Motor 0.5 HP Note : For Item No 4 to 9 (i) Periodical maintenance of installations is to be carried out by one experienced mechanic having minimum 5 years experience other wise Rs 5000/- per month per installation shall be recovered. (ii) Periodical maintenance is to be carried out for all machineries with connected network like suction/discharge lines, non return valves, butterfly/sluice valves, foot valves up to 300 mm bore, electric control panels with all controls etc all as directed by the Engr-in-charge or in charge JE E/M. (iii) All consumable items like grease, gland packing, nuts, bolts, washers and any other minor parts or any other related welding/grinding work required for smooth and noiseless functioning of installation. (iv) All T&P items required to carryout repair/servicing of the plant/machinery shall be provided by the contractor . (v) Repair/servicing works shall required to be carried in installations below ground level at sewage installation by the contractor. Cost of the same shall deemed to be included in the rates quoted by the contractor. (vi) Periodical maintenance of installations daily, weekly, monthly, quarterly, half yearly and early are required to be carried out as per PS.
Removal & disposal of ash and waste collected from plant room inside Cab Sectt and disposal to MCD low laying area by private vehicle complete all as directed. The vehicle shall be arranged by the contractor. Cost of the same shall deemed to be included in the rates quoted by the contractor.
M&L for servicing of combustion fan blower of capacity 5 HP by disconnecting electrically, mechanically and taking down, opening, replacement of unserviceable ball bearing of existing make and model-02 Nos, cleaning from inside and out side, alignment of blower and fan, re-assembling, re-fixing at existing location, connecting electrically and mechanically and testing complete all as specified and as directed.
M&L for disconnecting electrically and mechanically defective/ burnt blower motor of capacity 5 HP three phase 415 volt, shifting to civil workshop for repair, cutting of unserviceable burnt winding, taking out, cleaning of slots, rewinding with new super enamelled copper conductor winding wire of existing size insulating the same with suitable insulating materials, varnishing and other connected works, re-assembling, re-fixing at site & testing complete all as specified and as directed.
Supply only in replacement high temperature door gasket made out of asbestos as per existing size and shape complete all as specified and as directed.
Supply only in replacement thermocouple rod made out of stainless steel of 12 mm dia, 450 mm long, 'K' type as per existing size and shape complete all as specified and as directed.
Supply only in replacement pressure regulator/ switch differential type, RT-113 D 17 5196 complete all as specified and as directed.
Supply only in replacement main inlet line pressure gauge 6 inch dia of range 0 to 10 kg/sqcm rating all as required complete all as specified and as directed.
Supply only in replacement door limit switch 1NO+1NC as required complete all as specified and as directed. Make-L&T/Siemens/AE.
Supply only in replacement gas operating valve as per sample complete all as specified and as directed.
Supply only in replacement fire bricks for primary and secondary chamber of gas fired incinerator complete all as specified and as directed.
Supply only in replacememt cast able compound suitable for laying of fire bricks in primary and secondary chamber of Gas fired incinerator complete all as specified and as directed.
Supply only in replacement electronic burner tip of suitable size for 300000 K/Cal capacity burner complete all as specified and as directed.
S&F in replacement HT wire for burner GASXP 40 as per site requirement complete all as specified and as directed.
S&F in replacement Sequence controller for burner GASXP 40 as per existing make and model complete all as specified and as directed.
S&F in replacement HT electrode rod for burner GASXP 40 as per existing make and model complete all as specified and as directed.
S&F in replacement HT ignition transformer for burner GASXP 40 as per existing make and model complete all as specified and as directed.
S&F in replacement Gas solenoid valve NO 240V 50 BN complete all as specified and as directed.
S&F in replacement Gas solenoid valve NC 240V 50 BN complete all as specified and as directed.
S&F in replacement Ball bearing of size 6203 complete all as specified and as directed. Make: SKF/ NBC/ TATA
S&F in replacement Blower fan as per existing model complete all as specified and as directed.
S&F in replacement 7 pin connector male female as existing on site complete all as specified and as directed.
S&F in replacement Brass gas nozzle for burner GASXP 40 as per existing make and model complete all as specified and as directed.
S&F in replacement Gas strainer, flanged ends, size 40 mm bore with working pressure 5 Kg/cm2 complete all as specified and as directed.
S&F in replacement Gas train for burner GASXP 40 as existing on site complete all as specified and as directed.
S&F in replacement Canvas capable to withstand high temperature complete all as specified and as directed.
Supplying, laying and connecting in replacement GI tubing 25 mm bore, heavy grade with all fittings with screwed and socketed joints and fixed complete in trenches, wall, ceiling or laid in floor complete and making good the disturbed surface complete all as specified and as directed.
M&L for disconnecting electrically and mechanically defective induction electric motor of capacity 15/12.5HP electrically operated three phase 415 volt, shifting to civil workshop for repair, strip opening for inspection, cutting of unserviceable burnt winding, taking out, cleaning of slots, rewinding with new super enamelled, of existing size of copper conductor winding wire and replacement of unserviceable burnt insulating materials, sleeves etc, varnishing and other connected works, re-assembling, re-fixing at site, electrical connection fixing with pump set with nuts, bolts, washers as per original position and testing complete all as directed for satisfactory operation complete all as specified and as directed.
All as per srl item No 36 here-in-before but capacity of 10/7.5 HP complete all as specified and as directed.
M&L for dismantling defective centrifugal/mono block pump of capacity 15/12.5 HP and shifting from installation to civil work shop for repairing and replacement of bearings, impeller, shaft, gun metal bush, gland packing and gland plate, nut bolt and washers, studs, gaskets etc. and reassembling /fixing at site to it's original position incl testing on load for smooth functioning all as directed including transportation charges, testing and commissioning complete all as specified and as directed.
All as per srl item No 38 here-in-before but capacity of 10/7.5 HP complete all as specified and as directed. Notes for item Nos 36 to 39: (i) T&P items and any other minor items required for installation and commissioning of electric motor/ pump shall deemed to be including in the quoted rates. (ii) Any electric connection, nut, bolts, washers, flanges including welding and cutting work shall deemed to be including in quoted rates. (iii) Any major spares/ parts required for making the motor/ pump serviceable shall be measured and paid separately as "supply only" under relevant items of Sch.
Supply only in replacement Ball bearing for electric motor of capacity 15/12.5 HP as per existing model/6307 2Z/6306 2Z complete all as specified and as directed. Make-Tata/HMT/SKF/NBC.
All as per Ser Item No. 40 here-in-before but of capacity of capacity 10/7.5 HP as per existing model/6305 2Z complete all as specified and as directed.
Supply only in replacement Ball bearing for Pump of capacity 15/12.5 HP as per existing model/6307/6306 complete all as specified and as directed. Make-Tata/SKF/NBC.
All as per Ser Item No. 42 here-in-before but of capacity 10/7.5 HP as per existing model 6205 complete all as specified and as directed.
Supply only in replacement Gun metal/CI Impeller (as existing) suitable for pump of capacity 15/12.5 HP complete all as specified and as directed.
All as per Ser Item No. 44 but of capacity 10/7.5 HP complete all as specified and as directed.
Supply only in replacement complete gasket set suitable for pump set of capacity 15/12.5 HP complete all as specified and as directed.
All as per Ser Item No. 46 but of capacity 10/7.5 HP complete all as specified and as directed.
Supply only in replacement gun metal shaft suitable for pump set of capacity 15/12.5 HP as per existing model and make pump set complete all as specified and as directed.
All as per Ser Item No. 49 here-in-before but of capacity 10/7.5 HP complete all as specified and as directed.
M&L for re-metaling/machining work for shaft of pump set of capacity 15/12.5 HP, welding, grinding, polishing and matching to required size/shape complete all as suitable for the pump complete all as specified and as directed.
All as per Ser Item No. 50 here-in-before but of capacity 10/7.5 HP complete all as specified and as directed.
Supply and fixing MS coupling including flexible tyre, nuts, bolts and washers suitable for motor pump set of capacity 15/12.5 HP complete match with existing one complete all as specified and as directed. Make - Mitutoya Shakti/ Unique/ Lovejoy/ Dunlup.
All as per Ser Item No. 52 but of capacity 10/7.5 HP complete all as specified and as directed.
S&F in replacement 3 Phase, 415 volt, 50 Hz Semi Automatic Star- Delta starter in sheet steel enclosure suitable for 12.5/ 10 HP motor complete all as specified and as directed. Make-Havells/L&T/HPL
S&F in replacement 3 phase,415 volt, 50 Hz, DOL starter suitable for upto 7.5/5 HP motor complete all as specified and as directed.. Make-Havells/L&T/HPL
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr in deep for foundation etc or for shafts, wells, cesspits, mainholes, pierholes etc.in any type of soil for foundation and getting out and levelling of bottom surface to required level complete all as specified and directed.
Returning filling including levelling, watering and well ramming soil in layers not exceeding 25 Cm complete all as specified and directed.
Removing the excavated materials not exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting level complete all as specified and directed.
Cutting of existing road/PCC/RCC/Hard standing for laying of pipe including making good the disturbed surface to match with the adjoining surfaces with PCC 1:3:6 type C2 using 20 mm graded stone aggregate complete all as specified and directed.
Supplying, laying and connecting in replacement GI water tubing 100 mm bore, medium grade with all fittings with screwed and socketed joints and fixed complete in trenches, wall, ceiling or laid in floor complete and making good the disturbed surface complete all as specified and as directed.
All as per ser item No 60 here-in-before but size 80 mm bore complete all as specified and as directed.
All as per ser item No 60 here-in-before but size 50 mm bore complete all as specified and as directed.
All as per ser item No 61 here-in-before but size 40 mm bore complete all as specified and as directed.
All as per ser item No 61 here-in-before but size 25 mm bore complete all as specified and as directed.
All as per ser item No 61 here-in-before but size 20 mm bore complete all as specified and as directed.
All as per ser item No 61 here-in-before but size 15 mm bore complete all as specified and as directed.
S&F in replacement butterfly valve 200 mm bore flange type suitable for external bye pass arrangement including nut, bolts & washers etc complete all as specified and directed.
All as per ser item No 67 here-in- before but of size of 150 mm bore complete all as specified and as directed.
All as per ser item No 67 here-in-before but of size of 100 mm bore complete all as specified and as directed.
All as per ser item No 67 here-in-before but of size of 80 mm bore complete all as specified and as directed.
All as per ser item No 67 here-in-before but of size of 50 mm bore complete all as specified and as directed.
Supply and fixing in replacement cast iron body, Non return valve size 80 mm bore suitable for insertion between flanges complete all as specified and as directed.
All as per ser item No 72 here-in- before but of size of 50 mm bore complete all as specified and as directed.
S&F in replacement Gun metal, globe or gate valves with iron wheel head, screwed/ flanged both ends as per site requirement of size 80 mm bore complete all as specified and as directed.
All as per Ser item No 74 above but 50 mm bore complete all as specified and as directed.
All as per Ser item No 74 above but 40 mm bore complete all as specified and as directed.
All as per Ser item No 74 above but 25 mm bore complete all as specified and as directed.
All as per Ser item No 74 above but 20 mm bore complete all as specified and as directed.
All as per Ser item No 74 above but 15 mm bore complete all as specified and as directed.
S&F in replacement Ball brass valves, high pressure, with polythene float and flynut 20 mm bore complete, screwed for iron pipe or brass ferrule and fixed all complete all as specified and as directed.
M & L in replacement PTMT float valve complete with epoxy coated aluminium rod and HD wall of size 25 mm bore complete all as specified and as directed.
All as per Ser item No 81 here-in-before but of size 20 mm bore complete all as specified and as directed.
All as per Ser item No 81 here-in-before but of size 15 mm bore complete all as specified and as directed.
S&F in replacement water meter 4 inch dia(100mm) flanged type and with the specification of DJB to get the certification complete all as specified and as directed. Note:- The old meter shall be deposited in MES store.
S&F in replacement Gun Metal Foot valve of 50 mm bore complete all as specified and directed.
S&F in repair GI socket 50mm / 40mm size ISI marked complete all as specified and directed.
S&F in repair GI socket 25mm / 20mm / 15mm size ISI marked complete all as specified and directed.
S&F in repair GI elbow 50mm / 40mm size ISI marked complete all as specified and directed.
S&F in repair GI elbow 25mm / 20mm /15mm size ISI marked complete all as specified and directed.
S&F in repair GI union 50mm / 40mm size ISI marked complete all as specified and directed.
S&F in repair GI union 25mm / 20mm / 15mm size ISI marked complete all as specified and directed.
S&F in repair GI equal tee 50mm / 40mm size ISI marked complete all as specified and directed.
S&F in repair GI equal tee 25mm / 20mm /15mmsize ISI marked complete all as specified and directed.
S&F in repair GI nipple of size 50mm / 40mm into 4 inch / 6 inch long ISI marked complete all as specified and directed.
S&F in repair GI nipple of size 25mm / 20mm /15mm into 4 inch or 6 inch long ISI marked complete all as specified and directed.
S&F in repair GI reducer of size 50/40mm or 50/25mm ISI marked complete all as specified and directed.
S&F in repair GI reducer of size 40/25mm or 40/20mm ISI marked complete all as specified and directed.
S&F in repair GI reducer of size 25/20mm or 25/15mm or 20/15mm ISI marked complete all as specified and directed.
SANJEEV ENTERPRISES
JIWAN DASS THAREJA AND SONS
SETHI ENTERPRISES
national engineering
M/S ANIL KUMAR
ASHUTOSH BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .