Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.7 L+₹39,271 (1.02%)Rejected-Finance 430 D DEFENCE COLONY JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹39.0 L+₹65,850 (1.72%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹40.8 L+₹2.5 L (6.39%)Rejected-Finance 131 BASANT VIHAR NAUBASTA KANPUR NAGAR UTTAR PRADESH 208021 | KANPUR NAGAR | UTTAR PRADESH | 208021 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹41.1 L+₹2.8 L (7.36%)Rejected-Finance PLOT NO 702 ADARSH NAGAR MASHVANPUR KANPUR NAGAR UTTAR PRADESH 208019 | KANPUR NAGAR | UTTAR PRADESH | 208019 | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
3 May 2021, 6:00 pmClosed
CE Lucknow Zone
HQ CE Lucknow Zone, 17, cariappa marg, Lucknow 226002
REPAIRS TO ROOF TREATMENT AND CONNECTED WORK IN ZONE I and ZONE II AREA UNDER AGE BR II OF GE I KANPUR
2021_MES_432349_1
CELZ/KAN/T-21 of 2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE (I) Kanpur
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (I) Kanpur
₹96,000
Yes
22 Jun 2021
22 Mar 2021
5 May 2021
22 Mar 2021
3 May 2021
19 Apr 2021
Amount
Demolition of Brickwork built in cement morter complete all as specified and directed .
Demolition of reinforced cement concrete in Roofs, floors (other than groundfloors), beams, staircases, landing,chajjas and similar suspended work height upto 8 meter complete all as specified and directed by .
M&L for Brickwork with subclass‘B’ old size bricks, straight orcurved on plan exc 6m mean radius ,built in cement mortar 1:6 complete all as specified and directed .
M&L for Brickwork with sub class‘B’ old size bricks, straight orcurved on plan exc 6m mean radius ,built in cement mortar 1:6 ,except brick complete all as specified and directed .
M&L for Brickwork with sub class‘B’ old size bricks, straight orcurved on plan exc 6m mean radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed .
Dismenteling of Asbestos cement corrugated or semi corrugated sheets in roofcoverings complete all as specified and directed .
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed .
M&L for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by .
M&L for (Except sheet )6mm thick asbestos cement, corrugated orsemi-corrugated sheets in roofs, walls etc fixed with L- type or J- type or cranked hook bolt complete all as specified and directed .
M&L for Roof trusses (framed), trussed,purlins, crane gantries ,chajjas, rails and fastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) including distance pieces, cleats etc. fix with hilti bolt of size 6x100 mm grouted in slab and rafter as required on site complete all as specified and directed .
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed .
Dismantling timber scantlings 40 sq. cm and over in section, in any position as in framed work complete all as specified and directed .
Dismantling timber scantlings in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section complete all as specified and directed.
S&F wind ties for roof including secuiring bolts as directed ,including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling of terracing tile/brick tile single layer on roof complete all as specified and directed.
M&L brick tiles 40 mm thick with minimun flexural strength 1.5 N/sqmm set , joints grouted flush in cement mortar 1:3 mixed chemical (plastisizer) by weight of cement over 15 mm thick screed bed in CM 1:4 ,ponding test shall be done after laying of tile complete all as specified and directed.
All as per item no 16 of above but except tile complete all as specified and directed.
Raking out joints/ pointing to brick work,brick tiles laid in floors,surface channels, roofs, etc complete all as specified and directed.
M&L for Flush pointing to size 300mm x 15mm brick tiles, laid flat in pavings and roof in CM 1:3 including chemical (plastisizer using 3%) by weight of cement complete all as specified and directed.
Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Demolition by using hand held electric drills, cutting machine,chisels etc ( direct use of hammer on RCC roof for demolition is strictly prohibeted) of concrete of any description including mud in roof any thickness with and including roughening old concrete surfaces by picking , sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate in padding,coving , roof kerbs including haunching, benching etc complete all as specified and directed .
M&L for preparation of plastered roof surface by cleaning surface free from dust and other foreign materials etc and laying in repair Alatic poly propylene prolymer modified membrane pre fabricated 3mm thick with non woven polyster matt central core of 160 gms/sqm weighing not less than 3.5 kg/sqm laid over primer conforming to IS 3384 @ 0.40 lit/sqm by using LPG/Butane torch and applying uniform pressure with a roller with overlap of 100 mm in longitidunal direction and 150 mm overlap in tranverse direction laid as per manufacturers instructions complete all as specified and directed with and including the following :- (a) A coat of bonding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 kg per sqm (b) laying APP modified membrane described here-in -before with joints sealed with cement mortar 1:3 mixed with SBR latex @ 200 ml per bag of cement and curved well before lying the membrane (c) Applying bonding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 kg per sqm
Taking down 110 mm dia rain water pipe, any pattern with all fittings complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore single socketed in any lengthwith rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) bend 110 mm bore complete all as specified and directed.
Taking down cement plaster from brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces applying ACC Gold cement or equivalent finished even and smooth without using extra cement complete all as specified directed.
M&L for 15 mm thick rendering in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces applying ACC Gold cement or equivalent finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick rendering on ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed .
Taking up or down steel tubing and connections of 15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections of 20 mm bore complete all as specified and directed.
S&F of 15 mm bore steel tubing, 'medium grade' galvanised, with all fitting,fixed to walls with clips and ceiling or laied in floor/consealed complete all as specified and directed.
S&F of 20 mm bore steel tubing, 'medium grade' galvanised, with all fitting,fixed to walls with clips and ceiling or laied in floor/consealed complete all as specified and directed .
Refixing old steel tubing 15 mm bore and connections in new or old position (Walls, ceiling,floors, etc) with clips or consealed as required at site complete all as specified and directed.
Refixing old steel tubing 20 mm bore and connections in new or old position (Walls, ceiling,floors, etc) with clips or consealed as required at site complete all as specified and directed.
M&L for Cutting chases for concealed water tubing and making good in cement mortar 1:3 cutting not exc 10 cm girth in brick wall complete all as specified and directed.
S&F in repair HDPE triple layer ,white colour, rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) 500 liters capacity all as specified in SSR Part- I including hoisted and fixed in position either inside or outside of building, connecting up pipes,securing access cover etc including GI nipple of suitable sizes and numbers including 20 mm dia ball valve high pressure PTMT with epoxy coated aluminium rod with high density plastic ball complete all as specified and directed .
All as per item no 40 of above but 1000 liters capacity tank
M&L for Disconnecting existing tanks, exc 250 & n. exc 500 liter capacity setting aside (or lowering if required) for repairs,cleaning, etc. and hoisting if required reconnecting and re-fixing inposition complete all as specified and directed .
M&L for Disconnecting existing tanks, exc 500 & n. exc 1000 liter capacity setting aside (or lowering if required) for repairs,cleaning, etc. and hoisting if required reconnecting and re-fixing inposition complete all as specified and directed.
Dismantling boarding, any description, fixed in any positionwith nails complete all as specified and directed.
M&L hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs/ frame work by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners12.5mm dia. 40mm long complete all as specified and directed.
S&F anodised aluminium snap grid frame work of grid size 605 x 605 mm for false ceiling complete all as specified and directed.
S&F PVC 10 mm thick insulation panels of size 605 x 605 mm with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium as per specification and drawing complete all as specified and directed.
S&F in repair 20 mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
S&F in repair 20 mm dia ball valves,high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball screwed for iron pipe complete all as specified and directed.
JOG CONSTRUCTION
M/S MAA TARA TREATMENT PROJECT
Chandra Construction Company
RAFAKAT HUSSAIN GENERAL CONTRACTOR
Allied Builders And Engineers
Khalil Ahmed and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .