| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹33.5 L+₹1.7 L (5.31%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹33.9 L+₹2.2 L (6.79%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹36.7 L+₹5.0 L (15.7%)Rejected-Finance PLOT NO 4 SUDARSHAN ROW RESIDENCY GAWADE MALA PIPELINE ROAD SAVEDI AHMEDNAGAR 414003 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414003 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹37.2 L+₹5.4 L (17.1%)Rejected-Finance SR NO 281 3 7 ANAND NAGAR NEAR DHANORI JAKAT NAKA LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
17 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE-411003
REPAIRS / MAINTENANCE OF STREET LIGHT AND CONNECTED ACCESSORIES AT CENTRAL AREA UNDER AGE E/M-I AT GE (CENTRAL) KHADKI.
2023_MES_597721_1
8806/E8 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CENTRAL area
AS PER NIT
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹98,000
Yes
26 Jul 2023
23 May 2023
19 Jun 2023
23 May 2023
17 Jun 2023
7 Jun 2023
23 May 2023 - 31 May 2023
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cables, pole foundation,stays etc and getting out in soft loose soil, complete all as specified and directed by Engr-in-Charge
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cables,pole foundation,stays etc getting out in soft disintegrated rock, complete all as specified and directed by Engr-in-Charge
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed by Engr-in-Charge
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed by Engr-in-Charge
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed by Engr-in-Charge
Material and labour for road cutting upto 300mm deep and 200mm wide for crossing GI water pipe line through road including making good the disturbed surface by filling mass concrete complete all as specified and directed by Engr-in-Charge. NOTE :- Mass concrete will be measured and paid as saperate item.
Material and labour for fine stone dust for cousioning of UG cable complete all as specified and directed by Engr-in-Charge.
Material and labour for brick protection with sub class 'B' brick for UG cable complete all as specified and directed by Engr-in-Charge.
Dismantling taking out carefully old/unserviceable UG cable of any type any size from trenches/poles/ducts/LT panels after dismantling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store or for Sch of Credit.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at both cable ends complete all as specified and directed by Engr-in-Charge MAKE :- Polycab/Asian/Finolex/Grandlay
Description all as per item No. 11 above but 10sqmm 2 core complete complete all as specified and as directed.
Description all as per item No. 11 above but 16sqmm 2 core complete all as specified and as directed.
Description all as per item No. 11 above but 10sqmm 4 core complete complete all as specified and as directed.
Description all as per item No. 11 above but 16sqmm 4 core complete all as specified and as directed.
Description all as per item No. 11 above but 25 sqmm 3.5 core complete all as specified and as directed.
Dismantling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing or carrying to store for credit, complete all as specified and directed by Engr-in-Charge
Material and labour for steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long). complete all as specified and directed by Engr-in-Charge
Supply and fixing cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed including taking out old and unsv items complete all as specified and directed by Engr-in-Charge
Supply and fix earth continuity wire using GI wire not less than 4mm dia on pole incl dismantling taking out unsv GI wire complete all as specified and directed by Engr-in-Charge
Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit all as specified and directed
Supply and fix ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as specified and directed. MAKE :- M/s all Indi , ICC, M/s Bharat Conductors, M/s NICCO and M/s Indian Aluminium co
Painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps,brackets,swan neck etc with two coats of aluminium paint after surface preparation complete all as specified and directed by Engr-in-Charge
Numbering of LT poles serially with letter/number size width and height up to 40 mm in situ with black paint on white back ground all as directed by Engr-In-Charge.
Supply and fix GI tubing light grade 40mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, complete all as specified and directed by Engr-in-Charge.
Supply only GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection complete all as specified and directed by Engr-in-Charge.
Supply and fix LED security fitting 45 watt with LED driver and lens complete with suitable size bracket made of 40mm GI Pipe Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole incl dismantling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: TRP-409-45-57-SL-GL-NSG or Equivalent in Philips/Wipro.
Supply and fix LED security fitting 60 watt with LED driver and lens complete with suitable size bracket made of 40mm GI Pipe Light grade, clamps, nut, bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole incl dismantling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: TRP-409-60-57-SL-GL-NSG or Equivalent in Philips/Wipro.
Supply and fix LED security fitting 70 watt with LED driver and lens complete with suitable size bracket made of 40mm GI Pipe Light grade, clamps, nut, bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole incl dismantling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: TRP-409-70-57-SL-GL-NSG or Equivalent in Philips/Wipro.
Supply and fix LED security fitting 90 watt with LED driver and lens complete with suitable size bracket made of 40mm GI Pipe Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole incl dismantling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: TRP-409-90-57-SL-GL-NSG or Equivalent in Philips/Wipro.
Supply and fix LED flood light fitting 80 watt with LED driver and lens complete with all fittings incl 1.5 sqmm three core copper flexible conductor cable incl dismantling / taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: LFL-80-CDL/60M or Equivalent in Philips/Wipro.
Supply and fix LED flood light fitting 100 watt with LED driver and lens complete with all fittings incl 1.5 sqmm three core copper flexible conductor cable incl dismantling/ taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: CFS-504-100-57-60D-SL-GL-NSG or Equivalent in Philips/Wipro.
Supply and fix LED flood light fitting 120 watt with LED driver and lens complete with all fittings incl 1.5 sqmm three core copper flexible conductor cable incl dismantling / taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: LFLN-120CDL/60M or Equivalent in Philips/Wipro.
Supply and fix LED post top lantern 20 watt complete with 40/50 mm GI pipe support Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable incl dismantling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- Wipro Cat no: LP07-251-XXX-57-CL or Equivalent in Philips/Crompton Greaves/Jaguar.
Supply and fix LED post top suspended lantern 60 watt made up of die cast aluminium housing, polycarbonate diffuser, power coated IP-65 complete with all fittings, incl three core copper flexible conductor cable incl dismantling/ taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- Jaguar Cat No: LGTP08X060XW or Equivalent in Philips/Surya.
Supply and fix LED post top lantern 45 watt complete with 40/50 mm GI Pipe Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable incl dismantling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- Wipro Cat no: LP07-501-XXX-57-CL or Equivalent in Philips/Jaguar.
Supply and fix LED post top lantern 40 watt complete with 40/50 mm GI Pipe Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable incl dismantling / taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: LPTC-40-CDL/WW or Equivalent in Philips/Wipro
Supply and fix LED Bollard light with optically design reflactor and indirect-direct, downward directional, high performance, smartly designed asymmetric lighting landscapes of 11 watt , 230 Volt AC with all fittings complete on PCC foundation and fittings complete all as specified and directed by Engr-in-Charge MAKE :- Wipro Cat no: LB13-131-XXX-65-08 or Equivalent in Philips/Jaguar .
Supply and fix LED Bollard light , fantasy made of extruded aluminium housing to redefine landscape with better light quality and enhance architectural design, rated IP-65 of 11 watt ,230 Volt AC with all fittings complete on PCC foundation complete all as specified and directed by Engr-in-Charge. MAKE :- Wipro Cat no: LB14-131-XXX-65-08 or Equivalent in Philips/Jaguar.
Supply and fix LED Bollard light with robust design and efficient light distribution of 10 watt ,230 Volt AC with all fittings complete on PCC foundation all as specified and directed by Engr-in-charge. MAKE :- CG Cat No LBLSN-10-CDL/WW or equivalent, Philips/Wipro/Jaguar.
Supply and fix LED garden light compact and aesthentic polyester coated aluminium housing in ground/bushlight for vibrant parking area,pathway and gardens with high illumination and soothing experience of 8 watt ,230 Volt AC with all fittings complete all as specified and directed by Engr-in-Charge. MAKE :- Wipro Cat no: LF05-600-036-27-XX or Equivalent in Philips/Jaguar .
Supply and fix LED building security light 25 watt, 230V with lens complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25mm dia bracket of total length 50 to 80 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismantling / taking down unsv fitting any type all as specified and directed. MAKE :- CG, Cat Part No LSTS-25--CDL-M or equivalent , Philips/Wipro/Jaguar
Supply and fix bright light 8 inch Milky Doom, round shape outdoor type including taking down unserviceabble light fitting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection complete all as specified and directed by Engr-in-Charge MAKE :- Hensel Cat No.DK 2525 G
Supply and fix LED driver suitable for 25, 35, 45 & 60 watt LED security light including taking out defective driver any type, complete all as specified and directed by Engr-in-Charge. MAKE :- CG/Wipro/Havells
Material and labour for timer dial type suitable for pannel mounting including taking out old and unservicable time switch any type any size complete all as specified and directed by Engr-in-Charge. MAKE :- L&T/Legrand or equivalent.
Material and labour for 3 pole contactor ML-02 with auxilary contact 2NO+2NC coil 240 volts,50 HZ up to 415 volt 50 Hz, complete all as specified and directed by Engr-in-Charge. MAKE :- L&T/Legrand or equivalent.
Supply and fix Surge protector suitable for 25, 35,45/60 watt LED security light including taking out defective driver any type. complete all as specified and directed by Engr-in-Charge.
Material and labourfor three core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through PVC Conduit incl dismantling/ taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. MAKE :- Polycab/Finolex/Havells
Material and labourfor rigid non-mettalic PVC conduit of siz 20mm inclusive of all fittings i.e. tees,bends,elbows, bell mount tube ends and fixing accessories such as couplers, lock nuts,saddles, pipe hooks etc including taking out old conduit complete all as specified and directed by Engr-in-Charge
Material and labour for restraining of overhead ACSR conductor of any size of 4 wire 35-40 met span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor including providing required T&P complete all as specified and directed by Engr-in-Charge.
Material and labour for restraining of ACSR conductor of any size of 2 wire 35-40 met span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor including providing required T&P complete all as specified and directed by Engr-in-Charge.
Material and labour for restraining of GI Cradle guard hexagonal/rectangular of any size on 35-40 met span pole after disconnecting all binding on cross arms and redoing all bindings including providing required T&P complete all as specified and directed by Engr-in-Charge.
Material and labour for restraining of GI earth wire of any size 35-40 met span on pole after disconnecting all binding on cross arms and redoing all bindings including providing required T&P complete all as specified and directed by Engr-in-Charge.
Cutting/Trimming of tree branches arround 3.00 met distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc fron poles complete all as specified and directed by Engr-in-Charge.
Dismantling and taking down old/unsv insulator of any type any size from pole/stay complete all as specified and directed.
Supply and fix pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-Charge.
Supply and fix shackle type, porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed by Engr-in-Charge.
Supply and fix Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm complete all as specified and directed by Engr-in-Charge.
Supply and fix Heat shrink straight through joint LT 1100 volts grade 6 sqmm, 2 core, make-Raychem, Cat No-EPKJ0081 or equivalent of M-Seal/MS Seal/3M
Supply and fix heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 2 core, make-Raychem, Cat No-EPKJ0081 or equivalent of M-Seal/MS Seal/3M
Supply and fix heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKJ0123 or equivelant of M-Seal/MS Seal/3M
Supply and fix heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core, make-Raychem, Cat No-EPKJ0130 or equivalent of M-Seal/MS Seal/3M
Disconnecting LT cable of any size from DBs / Panel / pole / transformer for finding fault and Material and labour for defect rectification. LT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and complaint has to be rectified with in 12 hours after notification, failing to which Rs. 500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engr-in-charge. joint kit will be measured seperately in appropriate item in this schedule
Labour only for disconnecting LT cable of any size from pole (height 7.5 to 9 mtr) /transformer panel and re-connecting of cable at both end after removing carbon /burnt insulation part of cable by cutting refixing cable with new cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs500/- per day complaint will be recoverd.
Material and labourfor earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
Supply and fix MCB, double pole 5 to 32 amps, 240 Volts, 10 KA ‘’C” curve complete all as specified and directed by Engr-in-Charge MAKE :- Legrand cat part No 4086-09 to 4086-17 or equivalent Schneider / ABB
Supply and fix MCB, single pole, 5 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve complete all as specified and directed by Engr-in-Charge MAKE :- Legrand cat part No 4085-87 to 4085-95 or equivalent Schneider / ABB .
Supply and fix MCB TPN 40-63 Amps, 415 volt 10 KA, complete all as specified and directed by Engr-in-Charge MAKE :- Legrand cat part No 4086-59 to 4086-61 or equivalent Schneider / ABB
Supply and fix automatic street light switch using NATURE SWITCH for automatic switching of stret lights based on LUX level of natural light. Th sensor (Nature Switch) along with suitable Power contactor, MCB and support Terminals should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof,Termite proof and FR grade special moulding compound (Sintex make SMC junction box) conforming to IP54. The contactor, MCB and circuit wiring should suitable enough to take load of 8 kW single phase load, Contactor rating :40Amps (2-pole), MCB (Single pole) Rating 63 Amps (2 Nos) complete all as specified and directed by Engr-in-Charge. Nature Switch : Kakatiya Energy System Ltd, Hyderabad, Model : SWADEEP -02C8KW1P
Supply and fix automatic street light switch using NATURE SWITCH for automatic switching of street lights based on LUX level of natural light. Th sensor (Nature Switch) along with suitable Power contactor, MCB and support Terminals should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof,Termite proof and FR grade special moulding compound (Sintex make SMC junction box) conforming to IP54. The contactor, MCB and circuit wiring should suitable enough to take load of 12 kW load equally distributed over three phase load, Contactor rating :40Amps (4-pole), MCB (Single pole) Rating 63 Amps (3 Nos) complete all as specified and directed by Engr-in-Charge Nature Switch : Kakatiya Energy System Ltd, Hyderabad, Model : SWADEEP -02C12KW3P
Material and labour for PVC insulated, PVC sheathed twin flat core 1100 volts grade, 10 sqmm aluminium stranded conductor (incl PVC conduit/wire guard where required) complete all as specified and directed by Engr-in-Charge. MAKE :- Finolex/Polycab/RR cable
Description all as per item no. 72 above but size of cable 6 sqmm.
Description all as per item no. 72 above but size of cable 4 sqmm.
Description all as per item no. 72 above but size of cable 2.5 sqmm.
NOTE :- a) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint of Street light throughout for entire central area under AGE E/M-I Khadki. (b) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint of street light. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day. (c) Complaints have to be attended and rectified irrespective of number of trips/Complaints as alloted by Eng-in-Charge.
MANGAL ELECTRICAL STORES
Rajan Traders
Maruti Abhiyantriki
VP DEVELOPERS AND CONTRACTOR
SKS Electricals
Techmat trading solution
M/S. Niksun Electro-Infra Private Limited
ASHWAMEDH ENGINEERS
SHRI SWAPNAYOG ENTERPRISES
Mahindra Electric Stores
K D Electricals
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .