Superintending Engineer
office of the S.E., EUDC-II, Sec-18, Noida.
11 KV SS construction an Increasing Capicity TF
2024_PVVNL_922240_1
11 KV SS construction an Increasing Capicity TF
Open Tender
Electrical Works
Item Rate
60 days
office of the S.E., EUDC-II, Sec-18, Noida.
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E. EUDC-II, Noida.
₹48,000
31 May 2024
15 Apr 2024
20 May 2024
15 Apr 2024
20 May 2024
15 Apr 2024
Amount
Installation of Distribution Transformer against overloaded transformers in under EUDD-II, NOIDA. (DETAIL OF WORK MENTIONED IN TENDER FORM)
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 20
250KVA 11/0.4KV New Distribution Transformer
PCC Pole 8.5 mtr. Long
ST/PCC Pole 11 Mtr. Long
LT XLPE Cable Al. 1x240sqmm
LT XLPE Cable 3.5x240sqmm
ACSR Dog Conductor
LT XLPE CABLE AL. 3.5X240/3.5X400Sqmm
LT XLPE Cable Al. 1x400sqmm
ABC 3x120+1x95+1x16sqmm
MS Dropper Channel
Stone Pad
MS Top Channel (125x65x2240mm)
11KV Disc Insulator with Fitting
11KV Polymeric Pin Insulator with Pin
11KV TPMO with Polymer Insulator
11KV Fuse Set
T-off Channel (125x65x1300mm)
Stay set complete (G.I.Stay rod 16x1800mm, Stay wire 5Kg, Guy insulator, G.I.Stay clamp, bolt, nut & wasther with concrete grouting) for 11KV line as per specification
Supply and Errection of the ABOVE Following material AND SUPPLY & ERRECTION OF THE FOLLOWING MATERIAL for completing the work as per RESPO.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC/ST - 11 Mtr. Long Pole (b) PCC 8.5Mtr Long Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) PCC 8.5 Mtr Long Pole.
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) 11M Long ST/PCC Pole and 8.5 Mtr Long PCC Pole
Installation and Fixing of 11 KV Fuse Set: Assembling and installation of fuse set on the fuse set structure of the T/F. The work includes fabrication for proper fixing, if required. Complete work in all respect.
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying Fixing of LT XLPE Alu. Cable 3.5x400/240 sqmm at different locations of T/F as per site requirement. as per site requirement.
Laying Fixing of LT XLPE Alu. Cable 1x400sqmm at different locations of T/F as per site requirement. as per site requirement.
Laying Fixing of LT XLPE Alu. Cable 1x240sqmm at different locations of T/F as per site requirement. as per site requirement.
Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.
Construction of New Plinth for 250KVA & above capacity Distribution Transformers, The size of plinth shall be 2M long 2m wide and the height of the plinth shall be 1.50 M with 20 cm. thick top slab with 02 no. 125x65mm MS channel 2 M long embedded in it. The repairing work includes excavation of earth, laying of brick ballast pad for foundation brickwork, CC and plastering and proper curing. The ratio of cement/course sand/fine sand/brick ballast/stone grit as per RESPO schedule including unloading and Loading of the transformer with complete work in all respect. (All work and material in the scope of the Contractor)
Construction of New Fencing of Transformer. The fencing shall be frame of size 1.5mt x1.80 mt fabricated out of MS angle iron of size 40x40x5 mm having 2 Nos. legs of 45 Cm. long in each frameduly welded and fixed with wire mesh of size 75mm 25mm, 10 SWG within the frame, pressed under MS flat of size 25x5 mm inside the angle iron on all four sides with the help of approx. 20 Nos. bolts and nuts. of 10 mm dia along with cross bracing of 25x5 mm MS flat on every frame will be grouted in 1:2:4 cement mortar with cement, coarse sand 20 mm gauge stone ballast in the size 0.22x0.22x0.45 Mtrs. Every frame after repairing will be painted with one coat of red oxide and two coats of blue synthetic enamel paint of approved make after proper cleaning. The above mentioned frame will be jointed with each other with 70 mm long MS flat of size 25x5mm by first class welding as per site. Fabrication and providing of wire mesh fencing frame for gate of size 1.5x180 Mtrs. Fabricated as items no. 2 and fixing of gate frame at each S/S as per site requirement with grouted frame providing 3 Nos. 100 mm size heavy duty hinges duly welded and having suitable locking arrangment and proper painting.
Mounting and installation of above 11 KV 200 Amp. TPMO (Air Break Heavy Duty Switches) with 02 Nos. 75mm X 40mm X 2800mm galvanised mounting channels complete with providing and fixing of required galvanised holding clamps, heavy duty GI pipe 25mm dia with operating handle mechanism, nuts & bolts with supporting channel etc. by the contractor complete in all respect.
Supply and Installation of 800Amp. LT ACB panel with Structure at Transformers as per site requirement with chemical earthing and making of Plinth of the ACB and complete work in all respect as per specification. C&S HAVELLS, ABB, HPL ETC.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF DISC. INSULATOR WITH FITTING AS PER SITE REQUIREMENT.
Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement.
Providing and Fixing of clamp for LT with Nut &bolt for t.off as per site requirement.
FIXING OF MS DROPPER CHANNEL AS PER SITE REQUIREMENT.
FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT.
FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT.
Providing and Fixing of clamp for LT ABC with Nut &bolt for t.off as per site requirement.
Supply and Instllation and Fixing of Three Phase Junction Box as per site requirement. (GTP Approved).
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps.
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Providing and fixing of Stone Pad 300x300x75mm
Providing and fixing of Danger Board with Clamp and Nut & Bolt as per site requirement.
Providing and Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Providing and fixing of Hodling Clamp with Nut & Bolt and Washers for LT ABC and T-off as per site requirement.
Providing and fixing of Al. Crimping Lug 400Amp. as per site requirement.
Removal of 160KVA T/F from Sector 100 Noida C-186 and carriage its to any Store of PVVNL including loading and unloading from both sides.
Shiv Electricals
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .