| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bid | |
| 2 | L2₹11.7 L+₹19,951 (1.73%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹11.8 L+₹29,256.60 (2.54%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹12.1 L+₹62,897 (5.47%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹12.2 L+₹70,358 (6.12%)Rejected-Finance TUPKHANA PART 1 PO ARUNACHAL PS SILCHAR DIST CACHAR ASSAM 788025 | CACHAR | ASSAM | 788025 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹11.6 L
EMD Value
₹23,100
Closing Date
7 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
PROVISION OF STORE ROOM FOR STATION HQ AND COMPANY STORE NEAR BUILDING NO T 235 AT CIJW SCHOOL VAIRENGTE UNDER GE SILCHAR
2023_MES_574949_1
8748/E8
Open Tender
Civil Works
Item Rate
120 days
VAIRENGTE
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹23,100
Yes
2 Mar 2023
13 Jan 2023
13 Feb 2023
13 Jan 2023
7 Feb 2023
28 Jan 2023
20 Jan 2023 - 24 Jan 2023
Amount
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directeddisposing off complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar works, vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed
M&L for use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal in shape for rough finished surfaces of concrete complete all as specified and as directed
M&L for use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works, not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete complete all as specified and as directed
M&L for use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 200mm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exceeding 100mm but not exceeding 200mm wide for rough finished surfaces of concrete complete all as specified and as directed
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 10 to 15mm complete all as specified and as directed
S&F steel work in tubular trusses, purlins, posts, etc. including cleats, base plates, using tubular / square hollow sections, special shaped washer etc. using ERW or induction butt welded tubes / SHS conforming to IS: 1161-2014 & IS: 4923-1997 grade St-240 complete all as specified and as directed
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe-410W grade E-250 quality 'B' complete all as specified and as directed
M&L for MS framed works as in doors or gates of angle or other section with gusset plates, rails, braces, etc. drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe-410-W grade E-250 quality-A complete all as specified and as directed
M&L for mild steel TMT bars grade Fe-500D, 10mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L for mild steel TMT bars grade Fe-500D, 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L for mild steel TMT bars grade Fe-500D, 5mm dia and over, upto and including 10mm dia, as in stirrups, spacers, etc. cut to length, bent to shape required including cranking, bending and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed
M&L for hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as sub-bases, floors, etc. surfaces finished fair and even complete all as specified and as directed
M&L for 40mm thick plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregate as sub-bases, floors, etc. surfaces finished even and smooth complete all as specified and as directed
M&L 15mm thick screed bed or bedding layer in cement mortar (1:6) roughened to receive floor finish complete all as specified and as directed
M&L for RCC (nominal mix), 1:1.5:3, type A-1, using 20mm graded stone aggregates as in foundation rafts, footing, beams, plinth beams, bases of columns, basement slabs, under reamed piles, mass concrete, etc. complete all as specified and as directed Note: Reinforcing steel will be measured and paid separately under respective item herein
M&L for RCC (nominal mix), 1:1.5:3, type A-1, using 20mm graded stone aggregates as in columns, pillars, piers, posts, struts, etc. complete all as specified and as directed Note: Reinforcing steel will be measured and paid separately under respective item herein
M&L for RCC (nominal mix), 1:1.5:3, type A-1, using 20mm graded stone aggregates as in beams,cantilevers, bressumers, lintels over 1.5m span, and similar works complete all as specified and as directed Note: Reinforcing steel will be measured and paid separately under respective item herein
M&L for RCC (nominal mix), 1:1.5:3, type A-1, using 20mm graded stone aggregates as in slabs supported on walls, beams, columns, in floors, roofs, balconies, canopies, deck slabs, shelves and similar works complete all as specified and as directed Note: Reinforcing steel will be measured and paid separately under respective item herein
M&L for pre-cast RCC, 1:2:4, type B-1, using 20mm graded stone aggregates as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands and similar works set in CM 1:4 with plain faces including necessary formwork and chamfering, weathering, throating, etc. complete all as specified and as directed
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and fair without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
Supply only integral water proofing compound all as specified
M&L rendering 15mm thick in cement mortar (1:6) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.06sqm but not exceeding 0.11sqm each, 7 to 8mm thick of superior quality in floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
S&F factory made 28 to 30mm thick single/double leaf solid PVC moulded door shutter with particle board core (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2mm plain colour termite proof, water proof and fire resisitant PVC sheet on back face, duly fixed in frame at site as per specification complete all as specified and as directed
S&F factory fabricated flush shutters, 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed
S&F 100mm long aluminum anodised barrel tower bolt of extruded section complete all as specified and as directed
S&F 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F 100mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed
S&F in position two way sliding anodized aluminium glazed ventilator shutter with frame consisting of the following sections and specificions complete all as specified and as directed (a) Ventilator frame 2 track of size 60x25x1.5mm (b) Stiles and rails of size 35x25x1.5mm (c) 'T' section mullion of size 35x35x1.5mm (d) PVC gasket with 4mm thick tinted glass including aluminium handle and suitable locking device Notes: (i) Only size of opening will be taken for measurement purposes (ii) All necessary accessories, fittings, fixtures, including tinted glass shall be deemed to be included in the quoted rate
S&F in position three way sliding anodized aluminium glazed window shutter with frame consisting of the following sections and specificions complete all as specified and as directed (a) Window frame 3 track of size 95x25x1.5mm (b) Stiles and rails of size 35x25x1.5mm (c) 'T' section mullion of size 35x35x1.5mm (d) PVC gasket with 4mm thick tinted glass including aluminium handle and suitable locking device for 1No. glazed shutter (e) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wie staples including aluminium handle with suitable locking arrangements for 1No. gauzed shutter Notes: (i) Only size of opening will be taken for measurement purposes (ii) All necessary accessories, fittings, fixtures, including steel wire cloth, tinted glass shall be deemed to be included in the quoted rate
S&F false ceiling with powder coated GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with 2Nos. unequal flanges of 20 & 30mm and web 27mm fixed to surrounding wall using nylon sleeves at 900mm c/c with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m in length) of 0.55mm thickness, having curled web of 50mm and flange 26mm each with lips of 10.5mm fixed to intermediate channel with connecting clips at 457mm c/c to 6mm dia GI hangers (1.2m long) adjusting level fixed to roof slabs by means of ceiling cleats made of GI flat 40x3mm, 60cm long and expansion hold fasteners 12.5mm dia 40mm long including 4mm thick pre-painted decorative non-asbestos fibre cement building boards fixed with screws / laid / inserted on snap grid complete all as specified and as directed
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour (s approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm over new surfaces of brickwork,concrete, etc. including all necessary staging, scaffolding, etc.required complete all as specified as as directed
M&L for preparation of new masonry / concrete wall surfaces and applying two coats of acrylic disptemper over a coat of alkali resistant primer complete all as specified and as directed
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
Supplying, laying / fixing, testing and commissioning of 10sqmm 2 core electric cable, 1100V grade aluminium conductor XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
S&F steel water tubing, 40mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS: 1239 fixed to walls / ceilings or laid in floor / trenches for protection of cable, etc. complete all as specified and as directed
M&L for concealed point wiring with 1.5sqmm, single core, FRLSH PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point / bell point controlled by one 5A one way switch
One switch socket outlet 5 pin 5A on independent board
M&L for concealed point wiring with 2.5sqmm, single core PVC FRLSH insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, concealed in walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 2.5sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for one switch socket combination outlet 5 pin 15/16A multipurpose complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed
S&F socket outlet, 2 in 1, 5 pin, 5/15A flush type, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 2 in 1, 6 pin, 5/15A flush type, universal, ISI marked, 240V complete all as specified and as directed
S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F fan hook fabricated to shape with MS flat iron 25x6mm 300mm long 2Nos.bends with drilled holes including MS nuts, bolts, washers, etc. duly painted with two coats of synthetic enamel paint complete all as specified and as directed
S&F energy efficient BEE service value 6.0, five star rated ceiling fan, 1200mm sweep, 240V, single phase, 50Hz AC, 1400RPM, having brushless direct current motor (BLDC) with all accessories viz. down rod, regulator, etc. and connecting up with provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to ceiling fan complete all as specified and as directed
S&F heavy duty, PVC body with PVC blades, ISI marked energy efficient BEE five star rated copper wound exhaust fan / air ventilator fan, AC, single phase, 230V, 50Hz, 250mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including cutting hole in brick wall, grouting the nuts and bolts an making good the disturbed surfaces complete all as specified and as directed
S&F sheet metal enclosures for MCB distribution board 240V, SPN, 4 way, double door type, with magnetic locking system, flush on wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F MCB isolator SPN 240V, 32A, 240V, 50Hz, 'C' series, 10kA complete all as specified and as directed
S&F MCB SP, 240V, 10 to 20A, 240V, 50Hz, 'C' series, 10kA complete all as specified and as directed
S&L LED linear light fitting 20W, all purpose, surface mounting, batten type with polycarbonate housing, with integrated electronic driver, all accessories pre-wired, and connecting up with 3 core flexible PVC insulate copper cable of size 16/0.20mm including 20W LED lamp complete all as specified and as directed
S&F LED bulk head 10W with pressure die cast aluminium housing high efficient LEDs and enclosed with milky diffuser IP 66 protection, input voltage 90-300V, PF 0.95, CRI> 70, L 80 stranded luminaries with efficiency 100 lumen/Watt, with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed
S&F LED 25W building security light fitting with suitable bracket, MS clamps, nuts, bolts, etc. as required at site and connecting up with 3 core flexible PVC insulate copper cable of size 16/0.20mm including 25W LED lamp complete all as specified and as directed
S&F LED 10W B22 3 star lamp, white cool day light type complete all as specified and as directed Make: Havells, Phillips, Wipro, Surya, Crompton
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Notes for serial item No. 69: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
MS AFTAB LASKAR
Younus Khan
M/S Goutam Chakraborty
M/S R A ENTERPRISE
Bhuiya Construction
M/S TAPAN KUMAR RAY
m/s builders and suppliers
M/S MOLOY KUMAR DEY
Bidder Name
Bhuiya Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .