| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹258.6 CrAccepted-AOC ADMINISTRATIVE BUILDING TEXMACO RAIL ENGINEERING LIMITED TEXMACO RAIL ENGINEERING LTD BELGHARIA KOLKATA 700056 NORTH 24 PARGANAS WEST BENGAL 700056 | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | ₹258.6 Cr | L-1 | Accepted-AOC Being Least cost offer to MRVC |
| 2 | L-2₹262.7 CrRejected-Finance PLOT NO 1080 BIRLA AURORA LEVEL 21 DR ANNIE BESANT ROAD WORLI MUMBAI MAHARASHTRA 400030 | MUMBAI | MAHARASHTRA | 400030 | ₹262.7 Cr | L-2 | Rejected-Finance Not being Least Cost Offer to MRVC |
| 3 | L-3₹263.3 CrRejected-Finance | ₹263.3 Cr | L-3 | Rejected-Finance Not being Least Cost Offer to MRVC |
| 4 | L-4₹267.9 CrRejected-Finance BELAPUR BHAVAN PLOT NO 6 SECTOR 11 CBD BELAPUR NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | ₹267.9 Cr | L-4 | Rejected-Finance Not being Least Cost Offer to MRVC |
| Sl No | Description | Qty | Unit | Kiran Infra Engineers Ltd. | Siemens Limited | Konkan Railway Corporation Limited | TEXMACO RAIL AND ENGINEERING LTD |
|---|---|---|---|---|---|---|---|
| 1.10 | Total Value | 1 | Nos | 2,23,17,37,140 ₹263.3 Cr | 2,22,58,94,896 ₹262.7 Cr | 2,27,00,62,260 ₹267.9 Cr | 2,19,17,76,192 ₹258.6 Cr |
Tender Value
₹316.2 Cr
EMD Value
₹1.6 Cr
Closing Date
5 Dec 2025, 3:00 pmClosed
CSTE MRVC
Office of MRVC, Street address-Churchgate Station Building, M. K. Road City-Mumbai, Pin code- 400020
Design, Supply, Installation, Testing and Commissioning of Signaling equipments/gears in connection with Construction of Proposed 5TH and 6TH line in between Borivali (BVI)-Virar (VR) section in Mumbai Suburban under (MUTP-IIIA).
2025_MRVC_881720_1
MRVC-W-274
Open Tender
Construction Works
BORIVALI TO VIRAR MUMBAI SUBURBAN
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1.6 Cr
Yes
MRVC OFFICE CHURCHGATE MUMBAI
14 Feb 2026
15 Oct 2025
5 Dec 2025
16 Oct 2025
5 Dec 2025
28 Nov 2025
16 Oct 2025 - 28 Oct 2025
16 Oct 2025
Total Value
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Schedule A (Supply Items)
Indoor Supply
Design, manufacture and supply of Hot Standby Architecture Electronic Interlocking (EI) system complete as per specifications mentioned in chapter-VII of volume-II alongwith Interface Equipments, Relays, cabinets, racks, wires and wiring material etc and Industrial grade maintenance Terminals (with Industrial grade 55'' LED or higher size with UPS minimum 1 hr back up with Printer) as per requirements. All items shall be supplied as per, per functional bit/station for functioning of EI. For positive variation card/Module wise etc. breakup cost should be furnished by tenderer. Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately.
Supply, Installation and Commissioning of EI VDU (Industrial Grade Visual Display Unit, 4K with all suitable accessories Compatible to El Interlocking in Safe Mode 24x7 at controlling station. The item must comply minimum following specification:- a) Screen Size (Diagonal):- As below b) Resolution :- 4K c) Viewing angle degree: - 178x178 degree d) Brightness :- 500 Nits e) contrast ratio 4000:1 f) Backlit :- Direct LED g) Jack Interface: - HDMI -3 no. 1.2 DP, DVI USB 2.0 -2 no. CI Slot RF In AV In Component In (RCA5 Type) Digital Audio Out RGB In (D-sub 15pin)-PC PC Audio Input RS232C (D-Sub 9pin) RJ45 Stereo mini jack. h) Optical Out :- Available Note: - Screen size will be decided as per instruction of engineer incharge.
Supply and Installation of Modular power supply arrangement for VDUand industrial PC (Embedded PC)with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with potential free -1 No contacts (PFC) for two 110 V DCsources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters(Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos. 3. Isolated DC-DCconvertors- Input : 110 vDC Output : 24 V DC/ 10A,Qty -10No.s 4. 3 U SSrack with back panel mother board /front panel power connectorsinverter auto change over switchand all required over switch and allrequired protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty – 1 No. Make Gallant or similar.
Supply & installation of Industrial Grade Embedded PC as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 or latest.
Supply of documents for both Phase-I and Phase-II as per specifications mentioned in chapter-VII.
Supply of Instruments and Tool Kits required for Trouble Shooting and repair of hardware and software for EI as per specifications mentioned in chapter-VII of volume-II .
Earthing of EI equipment, relay racks and Power equipment etc to be done along with the supply of all requisite materials. Earthing shall be in the form of Ring Earth conforming to RDSO specification No. RDSO/SPN/197/2008 (with a min. of 6 maintenance free earth electrodes) as per specifications mentioned in chapter-VII.
Work Station Table large size with required fittings and arrangement for station Master Panel Operatopr room for Fixing of VDU-2nos as operating panel as per specifications mentioned in Annexure-2 of chapter-VII.
Design of ST/LT/TOC/Square sheet/RCC (Three copy) for approval. More than four line station
Re-Design of EI Systems after FAT/SAT with related to application logic & Interface Circuit. Note:-After FAT/SAT either Minimum 2 functional gear (Addition/Deletion of point/signal/Track) or modification in TOC minimum 5 routes in accordance of 3.47, 5.16 and other issues.
Dataloggers
Supply of Data logger system of 1024 digital and 32 analog inputs with IP/Ethernet protocol along with networking equipments/accessories for Railway S&T installation as per specifications mentioned in chapter-VII.
Failure Analysis System(FAS) & Fault Diagnostic software for data logger of 1024/2048 / 4096 digital inputs as per specifications mentioned in chapter-VII of volume-II
Failure Analysis System or Central Monitoring Unit with Printer. As per technical specification IRS: S-992006 (Amdt-4) or latest. The specification of Failure Analysis System should be got approved from the Engineer in charge before supply. The Specification of Failure Analysis System shall be as per technical specification given in contract Agreement or higher version as approved by Engineer In-Charge. (Technical specification shall be provided in tender documents.)
Supply of 750VA-ON Line UPS for FAS as per specifications mentioned in chapter-VII of volume-II
Supply of Battery Charger for Railway S&T installation self regulating floor mounting type with 230 V AC single phase input and output 24 V DC, 20A as per spec. IRS.S.86/2000 with latest amendments for datalogger.
Supply of 12V, 42 AH VRLA Batteries as per specification IRS:S 93/96 with amendment 1for datalogger.
CT Racks and other indoor material
Supply of Cable termination racks as per specifications mentioned in chapter-VII of volume-II
Supply of Relay QNA1-K AC, AC immunized, 08F/08B, 12F-4B, 24VDC ( 1000 Ohm ) as per specifications mentioned in chapter-VII.
Supply of PVC Venyl flooring linolium Sheet of 1.5mm Thickness
Supply of Fire Extinguisher CO2 type (capacity 6.5 kg.) (QTY 120 = 90 for Sig + 30 for Tele)
Indoor cables and wires
Supply of PVC flexible copper cable single core multistrand 1 x 2.5 Sq.mm (50 conductor each diameter 0.25 +/- 0.01) as per specifications mentioned in chapter-VII.
Supply of PVC flexible copper cable single core multistrand 1 x 6 Sq.mm as per specifications mentioned in chapter-VII.
Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm as per specifications mentioned in chapter-VII.
Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per specifications mentioned in chapter-VII.
Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per specifications mentioned in chapter-VII.
Supply of PVC flexible copper cable single core multistrand 1 x 35 Sq.mm (276 conductor each diameter 0.40 +/- 0.01) as per specifications mentioned in chapter-VII.
Supply of PVC Indoor Cable 1x60x0.6mm dia as per specifications mentioned in chapter-VII.
Supply of PVC Indoor Cable 1x40x0.6mm dia as per specifications mentioned in chapter-VII..
Supply of PVC Indoor Cable 1 x 24 x 1 mm dia as per specifications mentioned in chapter-VII.
Supply of Indoor tinned Jumper Wire of various colour as per specifications mentioned in chapter-VII.
Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. as per specifications mentioned in chapter-VII.
Supply of wire 16/0.2 as per specifications mentioned in chapter-VII.
Connectors, terminals, fuses etc for indoor
Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type terminal along with as per specifications mentioned in chapter-VII.
Supply of End Plate for above Item
Supply of End Stopper for above Item
Supply of DIN Channel for the terminals 1 Mtrs each.
D type fuse block non indicating type low voltage non detorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specifications mentioned in chapter-VII.
D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specifications mentioned in chapter-VII.
Tag block 200 way way with PVC covers as per specifications mentioned in chapter-VII.
Supply of Standard Tools set as per annexure-11 of chapter-VII.
Supply of Fuse auto changeover system for 0.6 to 4 Amp used in Railway Signaling System as per specifications mentioned in chapter-VII. One Automatic changeover Unit comprise 32 nos. of external Non Deteriorating Type or ‘G’ type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits.
Supply of Fuse auto changeover system for 4 to 10 Amp used in Railway Signaling System as per specifications mentioned in chapter-VII. One Automatic changeover Unit comprise 24 nos. of external Non Deteriorating Type or ‘G’ type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits.
Supply of test and measuring instruments as per technical specification
Supply of Cycle chain Machine for drilling hole in rail
Supply of RFID Marker Locator, 8000 Marker records, Built in GPS Module, 1.5m Depth Range 4 X 20 Digit LCD Display for 101.4kHz Telecom Markers. RFID Marker locator provided complete with Marker Database software and cloud data storage service facility (unlimited data storage) Make : Komplex or Similar
Power supply (IPS and DG set.)
SUPPLY AND COMMISSIONING OF SMPS BASED INTEGRATED POWER SUPPLY SYSTEM as per specifications mentioned in chapter-VII.
Supply of Microprocessor based universal earth resistance sensing ELD unit 12 channel AC/DC as per specifications mentioned in chapter-VII
Program switches, snap action, base mounting type along with acrylic cover and mounting bracket, 25A, 9 poles, and 3 positions as per specifications mentioned in chapter-VII of volume-II
Program switches, snap action, base mounting type along with acrylic cover and mounting bracket, 63A, 9 poles, and 3 positions make as per specifications mentioned in chapter-VII of volume-II
Power supply distribtion board for all supplies, with fuses and links, as per the instructions of engineer in charge.
Supply of Single phase, 50KVA TVSS
Supply of Isolation transformer Input 230V AC single phase 50 Hz Output 230 V AC Single phase 50 Hz Capacity 50KVA as per specifications mentioned in chapter-VII of volume-II
Supply of Copper Tape 25 x 6 mm (Bonding Ring Conductor) Mounted on insulated standofd (1 round)
Transformer Rectifier Set
Supply of Transformer 230V/110-130V Single Phase 5 KVA as per specifications mentioned in chapter-VII.
Supply of Transformer Rectifier 230V A.C./ 120V DC/40 A. as per specifications mentioned in chapter-VII.
Supply of Transformer Rectifier Set 230V A.C./ 24V DC/20A as per specifications mentioned in chapter-VII.
Supply of Rubber Mat for Power Equipment room. ( 5mm thick )
Supply of Distribution Cum Auto-changeover Box between two AC supplies of 110V as per specifications mentioned in chapter-VII.
Supply of Distribution Cum Auto-changeover Box between two DC supplies of 24/60VDC as per specifications mentioned in chapter-VII.
FIRE ALARM SYSTEM
Supply of anlog addressable two loop fire alarm control panel with minimum 125 devices per loop along with battery backup without GSM interface module as per RDSO/SPN/217/2025 Ver 3.1 or latest specifications mentioned in chapter-VII.
Supply of Addressable Manual call point with inbuilt fault isolator as per RDSO/SPN/217/2025 Ver 3.1 or latest specifications mentioned in chapter-VII.
Supply of Addressable loop powdered sounder cum strobe with inbuilt fault isolator as per RDSO/SPN/217/2025 Ver 3.1 or latest specifications mentioned in chapter-VII.
Supply of Addressable heat and smoke multisensor with base and inbuilt fault isolator as per RDSO/SPN/217/2025 Ver 3.1 or latest specifications mentioned in chapter-VII.
Supply of Aspirating (air sampling) type system for relay room with inbuilt fault isolator. Including smoke detector for Relay Room with programmable 4 stage alarm generation & with 4 addressable modules with control Panel,power supply unit, battery backup etc. and shall comply to RDSO/SPN/217/2025 Ver 3.1 or latest.
Supply of 2CX1.5 sqmm Un-armoured fire survival flexible cable (Fire survival circuit integrity cable) The cables should meet fire performance test under simultaneous action of flame, water stress and impacts on single sample at 950°C for minimum 2 hours, certified by UL or FM or Vds or LPCB or BRE Global or any recognized lab by Government of India and shall comply RDSO/SPN/217/2025 Ver 3.1 or latest or latest specifications mentioned in chapter-VII.
Supply of Analogue type Linear heat sensing(LHS) cable and shall comply to RDSO/SPN/217/2025 Ver 3.1 or latest or latest specifications mentioned in chapter-VII.
Supply and Installation of air sampling CPVC PIPE with all required fitting accesserios for aspiration smoke detector syatem an comply to RDSO/SPN/217/2025 Ver 3.1 or latest or latest specifications mentioned in chapter-VII.
Automatic Fire Suppression System (AFSS)
Supply of Automatic fire suppression system for signalling installation as per draft RDSO specfication no. RDSO/SPN/218/2016 * complete design of the system shall be UL/FM/VDS/LPCB approved. ** Each schedule item is suppoted with detailed annexures which are extract of draft RDSO spec. no. RDSO/SPN/218/2016 however all supporting annexure/ description are indicative and in case of any deviation details given in draft RDSO Spec. no. RDSO/SPN/218/2016 will prevail.
ASM Office articles
Supply of Office Revolving Chair Godrej Make Model No.9u02r Bravo Or Similar of reputed brand will be specified by Engineer in-charge.
Supply of Office Chair with continious Arm Model Godrej CH 1007 or similar.
Supply of Office Table of size of table of model no T9 of godrej or equivalent model of same make with 3 drawers on lef handside & one locker on the right handside.Olive brown with duplicate keys.
Supply of Plain storage almirah with 4 adjustable shelves size 1980 mm height,915 mm width, 485 mm depth.
Outdoor Supply
Colour Light Signals Main and Shunt, complete with LED units, posts, CLS Units etc.
Supply of Colour Light Signal Post and Assemblies Complete. as per specifications mentioned in chapter-VII.
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per specifications mentioned in chapter-VII.
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per specifications mentioned in chapter-VII.
Supply of 1 way Junction Route Indicator in FRP body without lenses and transformers as per specifications mentioned in chapter-VII.
Supply of 2 way Junction Route Indicator in FRP body without lenses and transformers as per specifications mentioned in chapter-VII.
Supply of 3 way Junction Route Indicator in FRP body without lenses and transformers as per specifications mentioned in chapter-VII.
Supply of 5 way Junction Route Indicator in FRP body without lenses and transformers as per specifications mentioned in chapter-VII.
Supply of Asign / AG sign Signal Unit as per specifications mentioned in chapter-VII.
Supply of Calling-On Signal Unit in FRP as per specifications mentioned in chapter-VII.
Supply of Offset bracket for main signal as per RDSO drawings
Supply of Hand Cuff Locks
Supply of Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990, Base, Hood, Cover etc as per specifications mentioned in chapter-VII.
Supply of dependent type LED based postiion light shunt signal unit complete in FRP body as per specifications mentioned in chapter-VII.
Supply of LED Signal lighiting base Unit for main Signal ( Green ) as per specifications mentioned in chapter-VII.
Supply of LED Signal lighiting Unit for main Signal ( Yellow ) as per specifications mentioned in chapter-VII.
Supply of LED Signal lighiting Unit for main Signal (RED) as per specifications mentioned in chapter-VII.
Supply of LED Signal lighiting Unit for ROUTE Indicator as per specifications mentioned in chapter-VII.
Supply of Calling ON Signal Lghitning unit as per specifications mentioned in chapter-VII.
Supply of LED Signal lighiting Unit for SHUNT Signal as per specifications mentioned in chapter-VII.
Supply of LED Signal Lighting unit for A sign as per specifications mentioned in chapter-VII.
Supply of Multi Lamp numeric indicator (LED) Single/double digit) as per engineer in charge
Outdoor cables Apparatus Cases and other Items
Supply of PVC insulated armoured, unscreened, underground railway signaling copper conductor cable of sizes core 12 x 1.5 sq.mm as per specifications mentioned in chapter-VII.
Supply of PVC insulated armoured, unscreened, underground railway signaling copper conductor cable of sizes core 6 x 1.5 sq.mm.as per specifications mentioned in chapter-VII.
Supply of Underground Jelly filled cable 6 quad cable for S&T installation in Electrified area 0.9mm Dia as per specifications mentioned in chapter-VII.
Supply of 48 Fibre ARMOURED OPTIC FIBRE CABLE as per RDSO /SPN/TC/110/2020 rev.0 or latest as per specifications .
Supply of 24 fibre Armoured fibre Optical Fibre Cable as per specifications mentioned in chapter-VII.
Supply of HDPE Telecom duct 50mm O/D & 42 mm I/D permanently lubricated Anti rodent and non flamable propogating hdpe pipe as per specifications mentioned in chapter-VII.
Supply of straight join for 48-fiber (four trays each accomodating 12 fibrers) with enclousersas per specifications mentioned in chapter-VII.
Supply of Modular type FULL SS location with details as per specifications mentioned in chapter-VII.
Supply of Apparatus Case HALF SS LOCATION without E type lock as per specifications mentioned in chapter-VII.
Supply of E type lock as per specifications mentioned in chapter-VII.
Supply of ARA Terminal blocks with links made of PBT as per specifications mentioned in chapter-VII.
Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 12 mm as per specifications mentioned in chapter-VII.
Supply of Phenolic laminated Sheet, grade P3 in standard size of 1200 X 1200 x 06 mm as per specifications mentioned in chapter-VII.
Supply of Thermo shrink Cable Jointing kit (Reinforced) TSF-2 type generally conforming as per specifications mentioned in chapter-VII.
Supply of Thermo shrink Cable Jointing kit for 12 core generally conforming as per specifications mentioned in chapter-VII.
Digging and laying of Outdoor cables.
Supply of RCC pipes half round of size 200mm dia outer and 150 mm dia internal 1 mtr long as per specifications mentioned in chapter-VII.
Supply of Half round RCC with 300 mm outer dia & 250 mm inner dia 1 mtr in length
Supply Polyolefin cable channel of size width 240/340 mm, height 155/230 internal/external, length 1meter produced of polyolefin with fire protection class K-1 in accordance with DIN 53438 Part-II for laying signaling/telecom cables, channel attachable to each other with male female swallow tail connectors and having a suitable detachable cover, as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications.
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per specifications mentioned in chapter-VII.
Supply of GI pipe, inner dia. 100mm dia. B-class as per specifications mentioned in chapter-VII.
Supply of GI pipe, inner dia. 300mm dia. B-class as per specifications mentioned in chapter-VII.
Supply and installation of Maintenance free Earth for out door gears
Supply of Maintenance Free Safe Earth Electrode including Earth enhancment material and all accessories required for Earth Connection as per specifications mentioned in chapter-VII.
Supply of Conventional earth electrode as per specifications mentioned in chapter-VII.
Supply of Lightening & Surge protection device,A class protection as per IS/IEC 62305 and NBC 2016 with Lightning Counter as per specifications mentioned in chapter-VII.
Point machines, KLCR boxes etc.
Supply of Electric Point Machine Non Trailable Design, 143 mm throw with lock detector, cable termination box and slide for lock and detector, low thrust rotary locking type, AC immunity 160V AC as per specifications mentioned in chapter-VII.
Supply of Electric point machine, Non trailable, internal locking, 220 mm throw, with IP67 motor ,Minimum AC immunity 400 VAC, with tools & complete accessories including complete ground connection and all insulation, crank handle and along with clamp point lock 60 kg, TWS as per specifications mentioned in chapter-VII.
Supply of Ground connections, complete set suitable for IRS type/approved point Machine for derail switch with tongue attachment insulation as per specifications mentioned in chapter-VII.
Supply of Ground connections, complete set suitable for TWS IRS type/approved point Machine for derail switch with tongue attachment insulation as per specifications mentioned in chapter-VII.
Supply of Key Lock Relay with different ward combinations (Three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24V DC or functional equivalent without base plates. as per specifications mentioned in chapter-VII.
Supply of 19" 42U cabinet for housing of Pre-wired Crank Handle cum key lock relay box (of metal) alongwith LEDs, with approved type push buttons, 8-way terminal strips, string rod, etc. as per Specification mentioned in chapter-VII of Volume-II (clause 7.6).
Supply, fabrication, fixing & wiring of wiring tree suitable to Siemens points machine as per sample given by Railway. This includes the supply of trminal plate with '8' terminal=02 nos. (Type SG 550901-0209034-001 for Siemens point machine), multistrand copper wire, dressing with thread & provision of copper lug of required size. This includes cost of 02 nos. wiring tree per machine.
MSDAC
Supply of Digital Axle Counter Multi section type complete sysem including the Central Evaluator and final track clearance relay for each secton, Reset boxes, LV boxes, All track side units with detection point complete assembly & fixing arrangement for each detection point, clamps deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station/ RH/IBH etc. with all other accessories fully wired and fully equipped as per specifications mentioned in chapter-VII.
Supply of Portable operator console for on site programming of Axle Counters along with necessary hardware and software aa per para 1.2 of Technical specifications.
Supply of Tool Kit for MSDAC suitable for the system supplied against item no. 135 of this schedule.
Supply of Train Management System --equipment Rack for EBISAT, Part No.ANR 002936 or equivalent
Supply of Basic shelf / Extender, Part No. ANR21580 shelf suitable for EBISAT FIU 890 or equivalent
Supply of Microprocessor Board CTR/1-2, 5 MEGA Part No. ANR 002264 suitable for EBISAT 890 FIU or equivalent
Supply of Bus extender Board BFK/4-1 Part No. 213530 suitable for EBISAT 890 FIU or equivalent
Supply of BFK Cable - Part No. ANR 213538 or equivalent
Supply of Converter Board CONV/4-2 suitable for EBISAT - Part No. ANR 002932 or equivalent
Power Supply Unit Card POW/702 part No. ANR 218720 suitable for EBISAT 890 FIU or equivalent
Supply of Input Board EIN/1-1 Board (Each card of 32 channels) suitable for EBISAT 890 FIU. or equivalent
Supply of 64 pin IDC EURO connector - Female With dustcover or equivalent duly approved by Railway Site in-charge.
Supply of 0.4mm 32 Pair PVC insulated indoor cable of Delton / Phinolex/Network make or superior.
Supply of P6 packet Programmable Switch or equivalent
Supply of 16 Amp Double Pole MCB with Transparent cover box Havells, Legrand ,Anchor or suprior make.
Supply of 5 Feet Local Aluminum Folding Ladder. Ladder should be self supported and it should be made up of rust proof Alluminium of Min 16 SWG. No plastic hinges/Step support should be used.
PLC TO INTERFACE
EI Sub rack system with non-vital cards for TMS interface: EI non vital output required to interface with TMS EBISET similar to Panel processor cards
Schedule B (Execution of works)
Electronic Interlocking (EI) Sytem
(a) Phase I- Installation, wiring, programming, testing and commissioning of EI equipment supplied as per specifications mentioned in chapter-VII of volume-II, including transportation from Consignee’s depot to site. The works and materials for installation, wiring, testing and commissioning, grouting, cutting of floors, walls, refilling of the same, re-plastering, required CC/ masonry works, fixing/ placing/ laying of insulated ladders/ casing-capping/ cable trays/ RCC/GI pipes / Cables, termination of cables with lugs/ connectors, painting,/ lettering are to be provided/ done by the contractor for the equipments supplied vide Item of Schedule "A" of this contract.This also covers the networking of built in EI Data loggers of all the stations to monitor the system to any other places where desired by Engineer-in-charge. (Without OC-4 Stations, With OC-1 station)
(b) Phase II- Installation, wiring, programming, testing and commissioning of EI equipment supplied as per specifications mentioned in chapter-VII of volume-II, including transportation from Consignee’s depot to site. The works and materials for installation, wiring, testing and commissioning, grouting, cutting of floors, walls, refilling of the same, re-plastering, required CC/ masonry works, fixing/ placing/ laying of insulated ladders/ casing-capping/ cable trays/ RCC/GI pipes / Cables, termination of cables with lugs/ connectors, painting,/ lettering are to be provided/ done by the contractor for the equipments supplied vide Item of Schedule "A" of this contract.This also covers the networking of built in EI Data loggers of all the stations to monitor the system to any other places where desired by Engineer-in-charge. (Without OC-4 Stations, With OC-4 station)
Phase I& II -After installation of EI System, Maintenance & Supervision for One year, as per details given in Special Condition of Contract, Technical requirement & SEM. Phase II (<15 days consider as one month) for 19 installations
Training of Technician/ Jr. Engineer for installation, Commissioning, Testing, Repairs & Troubleshooting of EI system. (Hard copies of training material/ course modules to be given to each participant).
Training of Officers for installation, Commissioning, Testing, Repairs & Troubleshooting of EI system. (Hard copies of training material/ course modules to be given to each participant).
Design of Miscellaneous diagram consist of Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram , Auto change over diagram , Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings (Three copy) for approval. More than four line station
Design of Cable Route Plan submission of Three paper copies for approval.
Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggeringreport, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD inA3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway’s alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards.
Preparation of Cable Route Plan of buried S & T Cables using Radio Detector 8200 GS or Similar model GPS Model,DGSP and Drone for Per Trench per Km. For existing cables as per the instruction of Engineer in-charge. Submission of Drone Report in Hard Copy 1 set and DGPS output in KMZ File format. In Yard Section
Dataloggers
Installation, wiring, testing and commissioning of 1024 digital & 32 analog inputs Data logger complete along with accessories with Contractors own wiring & fixing material as per specifications mentioned in chapter-VII of volume-II
CT Racks
Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc as per specifications mentioned in chapter-VII of volume-II
Fixing & Wiring of Q series QNA1K/QNA1 (Cutting in Provision) relays. relay base plate/metal to Carbon relay. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done aas per specifications mentioned in chapter-VII of volume-II Note:-Q-series relay wiring should be also done in apparatus cases with suitable fixing frame.Fixing and wiring material shall be supplied by the contactor.
Fixing of Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry as per specifications mentioned in chapter-VII of volume-II
Power supply (IPS)
Installation of IPS at 4 to 6 Line staion as per specifications mentioned in chapter-VII of volume-II
Installation, wiring, testing & commissioning of Microprocessor baased universal earth leakage detector unit 12 channel AC/DC as per specifications mentioned in chapter-VII of volume-II
Erection of power panel, power supply equipments, stabilizers, Transformers, rectifiers, battery chargers, thermo flasher, ELD programme switchesetc as per specifications mentioned in chapter-VII of volume-II
Instllation & Commissioning of TVSS
Installation of Automatic Changerover System it includes supply of casing cappin, lugs etc. requred for installation (Wire will be suppled by the Rlys.) as per specifications mentioned in chapter-VII of volume-II
Colour Light Signals Main and Shunt Signals
Casting of CC foundation for signal post as per specifications mentioned in chapter-VII of volume-II
Installation of Signal Post and signal Unit as per specifications mentioned in chapter-VII of volume-II
Fixing of Calling-on Signal/A-Sign/AG-Sign unit on signal post. The item includes fixing of Co- On signal /'A' sign/ 'AG' sign unit on signal post with bracket, hood etc. Item includes supply bracket & fixing materials etc. by the contactor. The item also includes termination of cables & wiring inside Co- On signal /'A' sign/ 'AG' sign unit as per standard practice and unit wiring with flexible wire. as per specifications mentioned in chapter-VII of volume-II
Fabrication and fixing of Signal Number Plate,'A' Marker,'AG' Marker,'P' Marker,Arrow Marker,'G' Marker,`C' Marker.marker disk on signals as per specifications mentioned in chapter-VII of volume-II
Casting of CC foundation for position light shunt signal as per specifications mentioned in chapter-VII of volume-II
Installation, erection and wiring of independent position light shunt signal/'F' marker.This includes fixing of shunt signal, surface base signal post,LED signal unit/ lenses, lamp hood and wiring of shunt unit and focussing the signal as per specifications mentioned in chapter-VII. All material such as wire,nut& bolt etc. will be supplied by the contractor. Inspection: Site Engineer
Fixing of Dependent type Shunt Signal unit with offset bracket as per specifications mentioned in chapter-VII.
Supply and fixing of Protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per standard practice as per specifications mentioned in chapter-VII.
Excavation, Cable laying and termination
Laying of HDPE duct in trench and its protective work as per specifications mentioned in chapter-VII of volume-II and as per direction of site engineer.
Splicing of optic fiber cable and making the splice joint with contractor's own splicing machine and tools.
Blowing and drawing of OFC through laid HDPE duct already provided in the trench as per approved cable route plan, taking due care while tranporting and sealing both the ends after laying as per specifications mentioned in chapter-VII.
Casting of CC foundation for SINGLE apparatus cases as per specifications mentioned in chapter-VII of volume-II
Casting of CC foundation for HALF/SS apparatus cases as per specifications mentioned in chapter-VII of volume-II
Installation of SINGLE apparatus cases as per specifications mentioned in chapter-VII of volume-II
Installation of HALF/SS apparatus cases as per specifications mentioned in chapter-VII of volume-II
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per specifications mentioned in chapter-VII of volume-II
Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied bv the contractor).
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture- both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.
Fixing of ARA terminals and fuse block with provision of holes on hylum sheet and fixing by galvanised nuts & bolts
Fabrication of Hylum sheet on MS angle/sloted angle in loc box
Digging and laying of Outdoor cables.
Digging of 1 M deep and 0.3M wide in all type of soil as per specifications mentioned in chapter-VII of volume-II
Digging of cable tranch 0.3 mtr Deep,0.3 mtr wide on asphalted platform / road as per specifications mentioned in chapter-VII of volume-II
Track Crossing 1 mtr deep x 0.3 mtr wide as per specifications mentioned in chapter-VII of volume-II
Horizontal direction drilling without damage to surface road manual or using Auger Machine of diamension 100mm as per specifications mentioned in chapter-VII of volume-II
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking/PVC cable channel. This also includes laying of cables in track crossings & road crossings as per specifications mentioned in chapter-VII of volume-II
Laying of trunking and Capping /Polyolefin Channel in trenchings as per specifications mentioned in chapter-VII of volume-II
Laying of half round pipe directly above cables in trenchings as per specifications mentioned in chapter-VII of volume-II
Laying of DWC/GI/ RCC full round pipe in trench as per specifications mentioned in chapter-VII of volume-II
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per specifications mentioned in chapter-VII of volume-II
Preparation of cable pit as per specifications mentioned in chapter-VII of volume-II
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50 m and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.
Supply and installation of Electronic passive cable route marker with frequency 101.4 KHz Diameter 12 cm, Thickness 34mm, Depth capability 1.5 metre
Termination of outdoor cables as per specifications mentioned in chapter-VII of volume-II
Supply and fixing of ferrules of different colour, printing of termination details/Functions in different colours of ferrules as per Railway specification and installation in Relay room,Location Box,CTR,JB and Power board etc, in Station and Sections as per policy for writing Signalling installation functions description as per instruction of Engineer incharge. All materials required (i.e. plastic strip lock) for the work shall be supplied by the contractor.
Remoaval of rails
Remoaval of sleepers
Installation of Earthing of signal gears
Installation of maintenance free earth electrode as per specifications mentioned in chapter-VII of volume-II
Installation of Conventional earth electrode as per specifications mentioned in chapter-VII of volume-II
Point machines, KLCR boxes etc.
Fixing of Electrical point Machine on the extended sleepers as per specifications mentioned in chapter-VII of volume-II
Fixing of KLCR relays in field in half location boxes/ Boxes in SM office. Item includes supply and fixing as per specifications mentioned in chapter-VII of volume-II
Fire Alaram & AFSS Execution
Dismantling
Dismantling of Out door signalling gears
Releasing of existing Relay Room and Axle counter room materials, includes indoor items complete
Releasing of lever frame , old location boxes, signal posts, equipment inside the location boxes , lifting barrier , rodding run,cranks,compensators, relays and relay racks, power equipments etc as applicable including breaking of foundation etc as per the instruction of Rly engineer at site & their transportation to SSE incharge at nominated depot.
MSDAC & Track circuits
Installationof Digital Axle counter Central Evaluator , Wiring from CT rack to Central Evaluator, Installation, and wiring of indoor & outdoor reset box and wiring the power supply including supply of 2 core shielded cable required size copper conductor as per specifications mentioned in chapter-VII of volume-II
Installation of EJB and Track devices of Digital Axle Counter as per specifications mentioned in chapter-VII of volume-II
Miscallaneous
Provision of maintenance of storage facility for safe custody and upkeepment of S&T materials & equipment of all kinds intended for use in caryying out the proposed works by setting up suitable store depot in private premises nearby Borivali-Virar section of Western Railway. The rate includes contractors own arrangement for suitable build up area of Aprox.700 sqft x4. as approved by the engineer, watchman for security of materials, transportation, electric supply, furniture & taxes etc, complete. The number of stores shall be 1 or 2 or 4 as per the required however total store-month will be as per the quantity.
Hiring of one AC vehicle ( Ertiga/Scorpio or equivalent) with driver in a month for transporting MRVC officials as per specifications mentioned in chapter-VII of volume-II
Hiring of one AC vehicle FOR CSTE OFFICE ( Innova or similar) with driver in a month for transporting MRVC officials as per specifications mentioned in chapter-VII of volume-II
Transportation of signaling material/equipments including loading and unloading in 10MT vehicle, anywhere to anywhere (One consignee to another consignee or from another division), and stacking at destination as per instructions of SSE in-charge as per inventory. For carrying heavy materials like cable drums, DG set, Electrical Lifting barrier pedestal, IPS, Batteries, Point machine etc. This item is applicable to only these items which are not covered in the supply schedule i.e. the items are to be provided by Railways.
Loading & un loading & transportation of material from the Stores of SSE (Sig) depot to any other nominated place & vice-versa with the permission of Engineer In Charge. (This item is applicable only for those items which are not covered anywhere in the schedule in the supply or execution.)
Provision of safety enforcers and data loggers to Engineer-in-charge of MRVC during currency of the contract in terms of clause no. 11.14.5 of Part 1 of general specification
Skilled man power to be provided by contrator for Engg JCBs working to provide marking & supervisory work for the S&T cables during digging work by JCBs and repairing /restoring/jointing of cables, if damaged. Cables & Joints Material will be provided by railway. White Chuna marking will be done by his/her. Chuna will provided by contrator. Information for deputing skilled man power for above work will be provided by Railway Engineer incharge before 24 hours from commencement of digging by JCBs. They will check cables route by Cable ruote tracer and will do chuna marking and will show the cables ( on rough sketch) available in a small length approximate 50-100 meters of digging. Note:- Minimum two man will be provided at a time including Cable jointer. they will stay whole time during JCB digging work. ( The CV to be got approved by Railway).
Preparation of drawings by the contractor’s draftsman by manual or through computer software such as AutoCad etc. The work includes preparation of drawings for temporary work, modification in the existing drawings, general drawings or any other drawings as directed by the Engineer. Note:- - The person deployed should be well conversant with working on computers and software like AutoCad OR similar software. - Payment will be made for carrying out above activities in shifts of 10.00 hours each on all working days.
Provision of temporary Goomty of 3X3X2.5 mtr on hire for NI working made up of waterproof tent with provision of 1 table, 1 chair and two incandescent lamps. (Electrical connection will be provided by Rlys.)
Vacuum Free packing in Anti-static Bags of all the cards and than wrapping it with bubble plastic. All card and its accessories should be than packed in Proper 2 layer hard corrugated Box.This also include complete wrapping of RACK/Cabinet with double Bubble plastic and single Layer Corrugated paper.
Hot dip Galvanizing as per RDSO Specn. ETI-OHE-13 [4/84] - Signal post, OFF Set Brackets dia 140mm and length upto 5600 mm./Location boxes, including to and fro transportation.
Hot dip Galvanizing as per RDSO Specn. ETI-OHE-13 [4/84] - Misc. M.S. Fabricated items like point roddings, P/D Brackets etc. length upto 1200mm including to and fro transportation.
Fixing of "C" Channel Clamps on Girders. Along with proper coupling of GI/DWC pipes. The work will be executed as per instruction of site incharge and site incharge may take decisioin as per site condition. All the fixtures, nut bolts, tolls required to fix the channel will be provided by contractor. Proper safety equipment like Helmet, Retereflective Jacket and whistle, flag is to be made available during execution of work.
Supply and Installation of Modular cable sealing system, for cable entries in to relay room based on multidiameter technology. Roxtec make Galvanized Frame G 6x3 or similar with EPDM Module, Stay Plate, Wedge, Assy gel etc. complete with all mounting/fixing accessories and modules.
Provision of bonding with contractors PVC jacket wire rope of Galvanised steel wire 6mm dia ( 6x 19 strands wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10mm for track jumper & fish plate joints bonds. PVC sheath should be made of type 6 compound as per IS 5831 of 1970 or latest. Reclaimed or recycled material should not be used. This will include drilling of 7.1 mm dia holes in rails (4Nos) and provision of two jumpers for each bond, clamping of bonds etc with contractors own materials and tools as per instruction of railway engineer at site.
Shifting of existing Full Location Boxes coming in the alignment of doubling. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. Any minor repairs in foundation due to patching shall also be carried out by contracor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only.
Shifting of existing Half Location Boxes coming in the alignment of doubling. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. Any minor repairs in foundation due to patching shall also be carried out by contracor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only.
Shifting of infringing cables.The item includes removal of infringing cables from existing trench & laying the same in new trenches .Digging, Placing of capping/Half round RCC pipe covered seperately.
Making an entrance for new cable in old existing location, Casting concreting and curing of foundation and restoring it to old position by perfect masonry/concreting work. Contractor will ensure that cable entered in Location Box is properly protected.
Patching work in old location box consisting 1) Digging of pit, cleaning of earth from all sides, breaking of seal of location boxes removal sand from location, marking of new cable holes 2) insertion of cable from ground 3) making place for cable termination in old location, shifting ARA, fuse etc after removal and termination including fixing of ARA. 4) Termination of cable in old location 5) Filling of sand and plastering to all sides upto 50mm below ground level.
Transferring of S&T cables from existing location box to new location box. The work includes breaking dismantling of existing foundation of location,excavating and removing/segregating coils of cables which may be about 10 mts in length.These cables are to be disconnected and removed from the existing location one by one as per the instruction and under the supervision of railway engineer present at site.The cable is then to be inserted and terminated in new location box,The item includes dresing of cable, making of wiring tree.The material required for lacing/dressing shall be arranged by contractor. The work isrequired to bedone systematically with due precaution during the blockor disconnection within the time that is allowed.The excavation work to be done carefully without damaging the cable to avoid any failure.(Termination charge will be given seperately).Note:Proportionate payment will be made if cale of other length One No. unit-One cable of 10 m length.
Releasing of cables from old location boxes and taking it into new location boxes. This includes excavating the earth to release the cables from old location box for taking it into new location. This also includes releasing the old location box and bringing it to nearest station / central cabin. Location (old) will be released only after ensuring all working cables have been shifted in New location.
Construction of Concrete platform around Location box foundation including steps, wherever required. The work includes Preparatory work like removing muck from surroundings of location box, disposal of muck away from embankment of tracks, surface leveling for construction of concrete plat form. Preparation of wooden frame along with required wooden planks for the concrete work, supply and transportation of all required materials, viz. cement, sand, gravel, water, concrete mixing tools etc. by deploying labours from station to site shall also inclusive. The work shall be carried out with smooth finishing on platform flooring and standard curing of concreting shall be done as per standard practice. Note: The Location box work sites are between the stations, Borivali to Virar Section. Location box sites are not road accessible. Transportation of work materials to site shall be done by deploying labours from nearest station. Arranging all required materials, transportation and concrete platform construction, flooring finishing and debris removal from work site shall be carried out by the contractor.
Removal of excavated/slip earth/ debris/ malba from the site of works to any other place outside Railway land/premises, including all excavations, handling, re-handling, loading, unloading and leading, etc. all labour and material as a complete job. Removal of Earth (all kinds of soils)/ROCKS, BOULDERS including mud/slush, slipped earth in catch water drains, side drains, over berms in cutting, water way of bridges, over coping of toe/breast/retaining walls etc. including crossing of nallah, railway tracks, making/repairing approach roads if required, all lead, lift, ascent, descents, or any other obstruction. Earth spoils to be dumped outside the cutting or railway embankments as per direction of Engineer in charge
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.
Locate the existing working S&T cable by cross trench across the exiting cable route at repeated locations along the expected cable path, Identification of the S&T cable, Mark the cable route physically, Excavate the cable trench along the identified cable path to expose complete working cable route cautiously to avoid any damage and subsequent failure of working signalling function. Protect the exposed working cable and keep watchman till the cable is shifted to clear the infringement. Further excavate second cable trench away from the infringement to shift the said exposed cable. Shift the working cable manually to new trench from the old route to clear the infringement, carefully without any damage and failure. The working cable may be one or two or a bunch of cable. if needed shall lay new cable in the new infringement free trench to use for transferring the signal function thereafter. this work is to be done in utmost priority condition to clear the infringement to enable Civil Engineering work. Contractor needs to provide proper resources at site. Transportation, Loading/Unloading of cable and laying of extra cable if required at the site shall be excluded in this item.
Providing HYDRA/JCB machine on hire basis speeding of the work during block/ non- interlocking railway work as directed by engineer in charge at site with all contractors machinery, fuel, operator, crew, assisting labour complete. The rate of hiring the machinery will be per machine per shift per block. One shift means working of 8 hrs or part thoroof. The item will be operated during block or Non-interlocking only for the purpose of specding up the work, for early completion of the work during the block and is intended to be onerated to provide additional resources over and above normal resources. The requirement of any machinery for executing a particular item during or prior to block is covered in the rate of relevant items only. The item will be operated at the sole discration of the engineer. - Hydra crane of 8 to 10 tonne capacity
TMS EXECUTION
Software Modifications like Site database in central server, Indication list changes & mapping with SDB, changes in detail pictures for Central control room & stations work stations, Changes in RVPU pictures, New tapping chart, EBISET program generation and configuration, etc as per New SIPs for various yards & sections. (1) Yard Modification of sation with route relay interlocking.
Design of non vital logic and interface circuits for panel indication by creating specfic signalling panel indications non vital output bits. Each non vital output bit will be used for interfacing with EBISET of TMS.
Fixing and crimping of EURO connector work includes crimping with 32 pair telecom cable at EBISAT end. Item also include complete testing of indication.
Laying & wiring of 0.4mm 32Pair PVC Indoor Cable from Relay Rack to TMS EBISAT. Items include termination of cable on TAG on Relay Rack(One Side)
Wiring for TMS indication as per approved circuit diagram from Tag Block to Tag Block and other terminals in the relay room & soldering.
Supply, Laying & Wiring of power wire for providing power supply to EBISAT / MODEMS. Item includes supply of power wire in different standard colors. Each wire will be of copper conductor, Multi strand as per IS 2465/1984 & 1S649/1990 of Size 1 x 6 sq.mm..
Dismantling and Relocation of EBISAT Rack along with its Card and accessories in the Relay Room. The work includes transportation of the EBISAT Rack along with its card and accessories from existing relay room to new location of installation
Installation, Testing & Commissioning of EBISAT ( FIU ) including communication networking equipment, modems, data connectivity.
Total Signalling Cost i.e Sch A+Sch B
Safety, Health and Environmental
Payment for ensuring implementation and monitoring of all provisions in Safety, Health and Environmental Manual (SHE Manual) of MRVC during execution of works through entire contract period including deployment of required SHE organization as mentioned in SHE manual with required qualification, arranging training to all workers and staff engaged for work, regular health check up of labours, arranging SHE meetings, SHE Inspection, SHE audit, SHE communication i.e. posters/ signages/ VIDEO/ Audio, SHE housekeeping, Safety training, provision of protective wears, labour welfare measures, Environmental management, traffic management of vehicles for construction activities, etc. complete as detailed in Safety, Health and Environment manual of MRVC.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.23 MB
TENDERDOCMRVCW274.pdf
Tender Documents • 26.20 MB
BOQ_926739.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid