GARRISON ENGINEER GWALIOR
GARRISON ENGINEER GWALIOR, MORAR CANTT GWALIOR-474006
REPAIR/MAINT OF EARTHING, LIGHTENING CONDUCTORS, SERVICE CONNECTION, MCCB/MCB, DBs OF OTM/MD ACCN AND SOLAR WATER GEYSER IN MAP ACCN AT MORAR CANTT UNDER GE GWALIOR
2021_MES_475780_1
8710/GWL/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GARRISON ENGINEER GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GARRISON ENGINEER GWALIOR
₹96,000
Yes
10 Dec 2021
20 Sept 2021
25 Oct 2021
20 Sept 2021
18 Oct 2021
4 Oct 2021
Amount
M&L for testing results of old earthing using calibrated earth tester & submitting result to engr -in -charge complete all as specified and directed by Engineer-in-Charge. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
M&L for painting on wall with synthetic enameled paint of black colour of 300 x 300 mm size and writing work for earth test result with date & year with white paint complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed by Engineer-in-Charge.
Description as per item 3 above but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified and directed by Engineer-in-Charge. Note for item No. 03 & 04 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely
M&L for dismantling & replacement of unsv lightening conductor assembly made out of GI pipe light grade of size 50 mm bore along with welded flange, fixed on the RCC roof of the bldgs with drilling/making hole and provide fastners, rubber washer 6 mm thick of suitable size at one end & GI reducer socket 50 x 40mm at another end connected with GI pipe light grade of size 40 mm bore with one end GI reducer socket to connect air termination & connector for earth strip duly fixed with necessary fastners, nuts bolts & washers in PCC 1:2:4 type B0 45cm x 45cm x45cm complete all as specified and directed by Engineer-in-Charge. Note : (i) GI pipe 50mm (1.5 RM for each)/40MM (1.0 RM for each) & air temination shall be measured & paid separately under relevant items. (ii) Water leak protection has to be ensured, Pure Resin based Chemical anchoring system. (iii) Air temination shall be measured & paid separately under relevant items
Taking down and replacement of old unsv air termination single pointed Aluminium rod 20 mm dia, 300 mm long for lightening conductor complete all as specified and directed by Engineer-in-Charge.
Taking down and replacement of old unsv test point terminal block made of gun metal or phosphorus bronze size 200x200x30mm drilled and screwed for fixing in wall with necessary fixing arrangements complete all as specified and directed by Engineer-in-Charge.
M&L for overlap jointing of addl requirements of Aluminium strips by making drilling holes 02 Nos with brass/GI nuts, bolts and lead washers complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing of porcelain insulator of required size not exceeding than 10 cm long with two nos hole each on both end for fixing properly with fastner, nuts & bolts on wall & roof of buildings for separated earthing stirp from building complete all as specified and directed by Engineer-in-Charge. Note : (i) Water leak protection has to be ensured, Pure Resin based Chemical anchoring system.
Supply and fabrication of GI pipe medium grade of size 40 mm bore for erection of lightening conductor complete all as specified and directed by Engineer-in-Charge.
Supply and fabrication of GI pipe medium grade of size 50 mm bore for erection of lightening conductor complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of Aluminium strip 25 x 3 mm with saddles and fixing screw etc. for roof conductors above ground & wall/batten or recessed or buried in ground complete all as specified and directed by Engineer-in-Charge.
Taking down and refixing of GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including all fittings for fixing complete for protection of copper/aluminium/GI strip complete all as specified and directed by Engineer-in-Charge.
M&L for demolition concrete of any description and any position not otherwise specifically provided for floor plinth protection or hard standing complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete in surface of ground and making good disturbed surfaces as it was existing by using the PCC 1:2:4 type B1 with 20 mm graded aggregate on cutting areas/ disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x 6 mm dia galvanised iron Strip complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 2 Core complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 4 Core complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 Core complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed by Engineer-in-Charge.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed by Engineer-in-Charge.
M&L for Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete all as specified and directed by Engineer-in-Charge.
S&F of tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed by Engineer-in-Charge. NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
S&F of sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp,4 pole & Including MCCB 100 amps 4 pole 16 KA complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down complete all as specified and directed by Engineer-in-Charge.
S&F of MCB DB, sheet metal enclosures double door TPN 4 way with bus bar 415 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed by Engineer-in-Charge.
S&F of MCB DB, sheet metal enclosures double door SPN 12 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed by Engineer-in-Charge.
S&F of MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed by Engineer-in-Charge.
S&F of MCB TPN 63 Amps, 415 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed by Engineer-in-Charge.
S&F of MCB SPN 63 Amps, 240 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed by Engineer-in-Charge.
S&F of MCB SPN 40 Amps, 240 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed by Engineer-in-Charge.
S&F of MCB SP 240 volts, 6 to 40 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed by Engineer-in-Charge.
S&F of MCB SP 240 volts, 63 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed by Engineer-in-Charge.
S&F of security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 x 6 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded copper conductor for connection from ceiling rose to light fittings incl testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for Checking/ Servicing/ Descalling and Testing of Solar heating system device complete, including incoming cold water, out going Hot water supply pipe line, gate valve, water storage Tank, heat exchanger tank, thermostate, heating element, power supply back up, solar panel Plate, glass wool, steel structure mounting system, PCC work, aluminium cladding material and other connected items complete all as specified and directed by Engineer-in-Charge. Note (i) Quoted rates includes for descalling material, labour, minor parts like nut bolts, washer, machine screw, of any size and tightening every parts of mounting structure etc. (ii) Major items shall be measured and paid under appropriate items of Schedule. (iii) Parts as required shall be make of existing make of solar heating system.
Taking down old unsv solar water heater heat exchanger flat plate collector panel from the roof with and including taking out or dismantling of the water supply connection without any damage of the serviceable fitting and fixture complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of new solar flat plate collector complete of size 2.01 Sqm (1992 x 1010 x 94 mm size) complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable heating element/thermostate from the solar water heating system of any size any capacity and any shape complete all as specified and directed by Engineer-in-Charge.
S&F of heating element 2 KW 230 V single phase suitable for solar water heating system complete all as specified and directed by Engineer-in-Charge.
S&F of thermostate auto reset 230 Volt 50 Hz single phase suitable for solar water heating system complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of hot water tank with and including of descaling of the tank with descaling solution and removing all scaling material and deposite at a distance not less than 100 mtr cleaning from the site complete all as specified and directed by Engineer-in-Charge.
Disconnecting & taking out existing unservieable float valve assembly 20mm bore of any description and in any position and supply, fixing, jointing and testing, 20mm bore, ball bras svalve, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC flat insulated aluminium conductor service wire 2 core 10 Sqmm complete all as specified and directed by Engineer-in-Charge.
anand enterprises
M/s raj construction
M/s Anupam Construction Co.
M/s Tirupati construction
M/S SANTOSH CONSTRUCTION CO
tanay enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .