Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹14.7 LAccepted-AOC | 1st | Accepted-AOC The lowest bidder Ms Jamna Construction is being accepted please. | |
| 2 | 2nd₹15.1 L+₹12,093 (0.81%)Rejected-Finance | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹17.2 L+₹2.2 L (14.9%)Rejected-Finance | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹17.7 L+₹2.7 L (18.2%)Rejected-Finance | 4th | Rejected-Finance L4 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Mar 2024, 6:00 pmClosed
GE AWC MHOW
GE AWC Mhow
REPAIR MAINT OF LEAKAGE SEEPAGE SUNKEN FLOORING INTERNAL DAMPNESS ROOFING RAIN WATER PIPES ROOF TREATMENT AND OTHER CONNECTED WORKS AT GEN ROAD JCOS OR MD ACCN AND MD ACCN IN AOR OF AGE BR IV UNDER GE(AWC) MHOW.
2024_MES_641778_1
8706 GE(AWC) /MHOW / OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹40,000
Yes
30 Mar 2024
10 Feb 2024
9 Mar 2024
11 Feb 2024
8 Mar 2024
24 Feb 2024
Amount
S&F Rotational moulded poly-ethylene water storage tanks (ISI marked) ( cylinderical vertical with closed top ) 500 litres capacity ,hoisted and fixed in position including dismantling of PVC water tanks exc 250 ltr but not exc 500 ltr complete all as specified and directed.
S&F Rotational moulded poly-ethylene water storage tanks (ISI marked) ( cylinderical vertical with closed top ) 1000 litres capacity ,hoisted and fixed in position including dismantling of PVC water tanks exc 500 ltr but not exc 1000 ltr, complete all as specified and directed.
S&F in repairs ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball , suitable for 25 mm bore pipe, screwed for iron pipe and fixed. .(Minimum weight 25mm-455 gms.) complete all as specified and directed.
Complete removal of exisiting wall treatment on old plaster or concrete surface complete all as specified and directed.
M & L applying two coats of distermper oil emulsion over a coat of primer over and incl applying minimum 1mm thick wall care putty on wall surface. complete all as specified and directeds
Material & labour for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr / 10 sqm over and including minimum 1mm thick exterior putty and crack to be filled with crack filler , complete all as specified and directed.
M & L preparing of plastered or unplastered surfaces of walls, cornices etc and applying two coats of Dr Fixit Raincoat Elastomeric Acrylic water proof exterior coating or equievalent over one coat of primer of DR Fixit Primesea or equievalent, complete all as specified and directed.
M & L for reparing of RCC projection, chajjas,roofs,facia, column etc by necessary preparation i.e scrapping ,cutting,chiseling,derusting and cleaning exposed reinforecement, surfaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1: 1-1/2: 3) using 12.5 mm graded crushed stone aggregate and reinforeced with welded mesh of weight exc 2Kg per sqm but n.exc 3Kg/sqm with or without facia and finished including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 3 storey bldgs complete all as specified & directed (Note : Steel welded mesh is to be tightend / welded with the existing re-inforcement. The cost of welded mesh is deemed to be included in the unit rate quoted by the contractor)..
M & L PCC 1:5:10 type E-2 using 40 mm graded stone aggregate as in mass concrete incl demolition of old PCC complete all as specified and directed.
M & L for appling one prime coat acrylic polymer modified water proofing coating(Brushbabd of FOSROC or equivalent) and over that two coats of acrylic polymer modified two component elastomeric water proofing membrance coating (Brush band of fosroc mate or equivalent) complete all as specified as per manufacturers instruction as directed by engineer-in-charge.Make:- Fosroc,Sika,Dr fixit Note :-1 . This item shall only be executed through level 4 or level 5 certified and authorised applicator of the company. 2. A warranty for 5 yerars in the form of written agreement shall be submitted by the contractor. 3.The rate quoted by the contractor shall include all the provision mention in this item including notes. 4. Applying 15-20mm thick protection plaster 1:3(Cement : Sand) ration on vertical and horizonal areas admixed with Dr.Fixit Pidiproof LW Plus(Conforming IS 2645 2003) @200ml per bag of cement.
S & F 40 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc incl clamping complete all as specified and directed.
S & F in repairs vitreous china squatting pan 'Orissa patern' size 580 mm X 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage pipe, etc complete including making good to floor
S & F in repairs Vitreous chaina wash down water closet pan (pedestal pattern), white including pedestrial pan and trap, including seat cover for pedestial pan and connecting to drain or outgoing pipe and to flushing pipe, antisyphonage pipe etc complete all as specified and directed.
S & F in repairs 10 litres capacity PVC low level cistern ‘ white’ with inlet, float valve and handle including flushing pipe of PVC 32 mm dia and connection to pipes complete all as specified and directed.
S & F in repairs PVC connection 15 mm dia 600 mm long with PTMT nuts at both ends complete all as specified and directed.
S & F in repairs Vitreous china urinal, half stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe, complete all as specified and directed.
S & F in repairs vitreous china wash hand basin white or any colour , flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe and incl 15 mm dia bore fancy type chromium plated swan neck pillar tap, cast copper alloy, with capstan heads complete all as specified and directed.
S & F in repairs PVC pipes 160 mm bore single socketed in any length with rubber ring joint and fixed to walls incluidng clamping complete all as specified and directed.
S & F in repairs PVC bends 160 mm bore any radius with solvent cement joints, fixed complete all as specified and directed.
S & F in repairs PVC pipes 110 mm bore single socketed in any length with rubber ring joint and fixed to walls incluidng clamping complete all as specified and directed.
S & F PVC bends 110 mm bore (with or without access door) any radius with solvent cement joints, fixed complete all as specified and directed.
S&F in repairs PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints with solvent cement fixed to walls incluidng clamping complete all as specified and directed.
S & F in repair 75 mm dia bore PVC (SWR) bends (with or without access door) any radius with solvent cement joints, fixed to complete all as specified and directed.
S & F in repair 110 mm dia bore PVC (SWR) junction single, single (T) equal or unequal(with or without access door), joints with solvent cement,complete all as specified and directed.
S & F in repair PVC (SWR) nahani trap/floor trap with grating having diameter of outlet 75 mm including joining to waste pipe with solvent cement complete.
S & F in repairs 110 mm bore PVC(SWR) vent cowl complete
S & F of CPVC 20 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl taking up or down steel tubing pipes complete all as specified and directed.
S & F of CPVC 25 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl taking up or down steel tubing pipes complete all as specified and directed.
S & F of CPVC brass elbow (3/4" X ½") for 20 mm outer dia CPVC pipe complete all as specified and directed.
S & F of CPVC Male Brass Threaded Adaptor (MTA/ MBTA) for 25 mm outer dia pipe complete all as specified and directed.
S & F of CPVC Tank Adaptor for 25 mm outer dia pipe complete all as specified and directed.
S & F of CPVC union for 25 mm outer dia pipe complete all as specified and directed.
S & F of CPVC Ball Valve for 25 mm outer dia pipe complete all as specified and directed.
M&L fly ash brick work with modular brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 and incl demolition of old brick wall complete all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cills, steps, seismic and other similar bands, plinth courses, string courses, parapets and railing upto 60 cm in height, coping, kneelers, apex stones bed plates, etc and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary use and waste of form work complete and incl demolition of old PCC. complete all as specified and directed.
M & L rendering 10 mm thick on brick wall/cement block wall or concrete surfaces in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete and incl taking down cement plaster on brick or stone walls/ concrete surface, etc. all as specified and as directed.
M & L rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling surface finish even and smooth without using extra cement and incl taking down cement plaster on brick or stone walls/ concrete surface, etc. complete all as specified and directed..
M & L rendering 15 mm thick in cement mortar 1:4 in two layers, 10 mm thick plaster in first coat with WPC and second coat of 5 mm thick with WPC as per manufactures instruction, surfaces, surfaces finished even and smooth without using extra cement and incl Taking down cement plaster on brick or stone walls/ concrete surface, etc. , complete all as specified and as directed. (WPC will be measured and paid separately)
M & L rendering 10 mm thick on brick wall/cement block wall or concrete surfaces in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L rendering 15 mm thick in cement mortar 1:4 in two layers, 10 mm thick plaster in first coat with WPC and second coat of 5 mm thick with WPC as per manufactures instruction, surfaces, surfaces finished even and smooth without using extra cement , complete all as specified and as directed. (WPC will be measured and paid separately)
Supply only liquid water proofing compound all as specified and directed
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed
M&L Granite 20 mm thick(of any type) work (table rubbed and polished) for wall lining (Veneering to wall) and laid on cill of parapit wall over 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite colour Red or brown as per direction of GE
M & L 22 - 25 mm thick machine cut Kota stone slab in flooring or treads single piece of steps over and including 15mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed. Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size, except the location where the balance portion remain less than size as specified above.
-Ditto- but as in riser of steps, skirting, dado and vertical surfaces including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
S & F in repairs 15 mm bore bib taps chromium plated fancy type cast copper alloy crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, and fixed complete all as specified and directed.
S & F in repair Bidet spray (Health faucet) with 1 meter tube and holder, complete all as specified and directed.
S & F in repairs chromium plated fancy type stop cock/angle cock 15 mm dia cast copper alloy screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed, complete all as specified & directed.
S & F in repairs 15 mm bore two way bib taps long body, chromium plated cast copper alloy long body , screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S & F in repairs brass chromium plated tubular towel rail, 20mm dia D type 60 cm long between flanges complete all as specified.
S&F in repairs 15 mm dia bore fancy type chromium plated swan neck pillar tap, cast copper alloy, with capstan heads, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
M & L machine pressed precast concrete 60 mm thick glossy interlocking paver block M-35 Grade to IS 15658-2006, with grey cement and no pigment laid over dry sand cushioning, filling of joints with sand including demolition of stone slabs/PCC block/ tiles of any description or thickness etc. (incl bedding) colour and shape as approved, complete all as specified and directed. (Note : Sand cushioning shall be measured and paid separately) .
M & L sand filling under floors or interlocking tile or in foundation including watering and consolidation complete all as specified and directed
M & L PCC 1:4:8 type D-2 using 40 mm graded aggregate as in mass concrete, floor sub base, foundation and any other location etc. and including demolition of old PCC, complete all as specified and directed.
M & L 25mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as in floor incl demolition of old concrete all as specified.
Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premisses complete all as specified and directed.
M&L non skid/mat finish ceramic colour tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm (Colour and design of tiles as approved by GE), in floors/skirting etc, and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
-Ditto- as per item No 59 above but in vertical surface including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M & L non-skid / mat finish coloured joint free ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:4 complete all as specified and directed. Note :- Tiling shall be as in patches or of any size or any description , any colour, any location or all as directed by Engineer - in -Charge.
M & L glazed ceramic coloured tiles, 300mm x 200mm / 300mm x 450mm / 350mm x 450 and 7 mm thick on vertical surfaces such as dados, skirting and risers to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick backing coat to receiving to wall tiles in Cement mortar 1:4, including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Disconnecting existing tanks capacity exc 250 & n exc 500 ltr, setting aside (orlowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Disconnecting existing tanks capacity exc 500 & n exc 1000 ltr, setting aside (orlowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
M & L 10 mm thick rendering in CM (1:3) mixed with (incl) integral water proofing chemical compound PIDIPROOF LW of DR FIXIT of PIDILITE INDUSTRIES LTD or STP No 1 (liquid) of STP Ltd @ 200 mililitre per 50 Kg cement as per manufacturers instructions over concrete surface and finishing the surface fair and even without using extra cement complete all as specified.
M & L cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in levelling course incl demolition of old concrete all as specified.
M&L Water proofing treatment on "Non approachable / non accessible roof" surface (Horizontal & Vertical surfaces) in following sequence through authorized applicator of the manufacturer all as specified and directed complete. (i) Cleaning of new rendered surface properly and drying the surfaces. (ii) Applying a coat of oxidised bitumen based solvent primer @ 0.30 Kg/ Sqm. (iii) Laying 3 mm thick APP modified water proofing membrane with 100 mm over laps sealed and bounded to the surfaces by 'torchon' method. (iv) Applying two coats of bitiminous aluminium pait @ 200 Gram / Sq M (minimum) in two coats. Make incorporated : HYPERPLUS of IWL (INDIA) LTD or equivalent in Pidilite industrries Ltd / STP Ltd all as specified and as manufacturer instruction complete.
S&F PVC waste pipe fixed to any type of coupling of 32 mm threaded complete all as specified and directed.
M &L for Pre-painted galvalume aluminium zinc coating GI based plain/corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, and eves board fixed with self tapping screws as specified including dismantling 0f existing sheets.
S & F Joist channel, angle or tee, square or rectangular tubler sections fixed independently or as purlin, rafter or post incl cutting to dead length where required notching drilling firing riveting and/or welding or connecting with bolts and nuts providing and fitting angle cleats fish plates, gusset plates etc complete all as specified and directed (Fe-410-W (gde-E-250) quality A)
S&F in repair CP wall mixer, for mixing hot and cold water fancy type cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure with long screwed shanks and fly-nuts , screwed for iron pipe ISI Marked of other specified.
Supply only 15 mm dia bore basin mixture brass chromium plated with capstan heads screwed down high pressure with or without letter ‘HOT’ or ‘COLD’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed. (Make : Plumber Cat part No AZT-3104/Prayag : Cat part CAT NO-8750/ Jaquar Cat Part No FLR-5167NB)
S&F in repair 15 mm bore sink mixer with swining / rotatable spout with connecting and wall flange, complete all as specified and directed.
S & F in repairs corner glass shelf 250mm (10'') long complete as per sample approved by AGE B/R-III complete all as specified and directed.
S & F in repair glass shelf in long size fixed with and including chromium plated brass screws and wooden/plastic cleats.( Min wt 300gms) complete all as specified and directed.
S & F in repair PVC bath cabinet box type with shutter complete all as specified and directed.
M/S Sunshine Construction
RK CONSTRUCTION
PREMCHAND BHAWANI SAHAI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .