| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-AOC NO 15 3 BREEZE APARTMENT SERVICE ROAD NOLAMBUR CHENNAI 600037 | CHENNAI | TAMIL NADU | 600037 | ₹4.6 Cr | L1 | Accepted-AOC Work order issued |
| 2 | L2₹4.8 Cr+₹21.2 L (4.60%)Rejected-AOC CHENNAI 600 095 | CHENNAI | TAMIL NADU | 600001 | ₹4.8 Cr+₹21.2 L (4.60%) | L2 | Rejected-AOC Unsuccessful tenderer |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Qualified Tenderer |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Qualified Tenderer |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
7 Jan 2025, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Construction of 15 Nos. of Firemen Quarters (Stilt plus 5 Floors) with development works at Peelamedu in Coimbatore City.
2024_TNPHC_511260_1
SE/NC/DB/3382/2024
Open Tender
Civil Works
Lump-sum
330 days
Peelamedu in Coimbatore City.
Construction of 15 Nos. of Firemen Quarters (Stilt plus 5 Floors) with development works at Peelamedu in Coimbatore City.
9 documents required · 9 mandatory
₹0
₹3.0 L
21 Mar 2025
16 Dec 2024
9 Jan 2025
16 Dec 2024
7 Jan 2025
16 Dec 2024
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.5 : Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
7.2 : Supply and fixing of Bituminous filler pad, 20 mm tk. for expansion joint
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
25 : M.S.Holdfast
30 : Ellispattern
31 : Weathering course
39 : S & F of M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
46 : S & F 20 mm dia Alu. Hanger Rod
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
49 : S & F chromium plated 8 guage Picture Hook
50.4 : Providing Tree guard
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
52.1 : Supplying and fixing of 20mm dia "B" Class GI pipe for Hot water line (Fully Concealed in walls)
53.3 : C.I. Steps ( 5 kg)
Electrical arrangements 69 : 16 Amp. Power plug
72 : Box type Fibre Fan hook
74 : Charges for fixing of "Fan"
76 : 8 SWG wire
78 : Earthing Station IS3043 (Type I)
86 : Anti termite treatment
ANNEXURE-I 2.1.1 : Supplying and filling with Gravel
2.1.3 : Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 : P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
3.3.1 : P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
3.8.1: P.C.C. 1:4:8 using 40mm HBGS jelly (using crushed stone sand)
6.2.1.1 : Brick work in C.M. 1:5 (F& B) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM²
8.3.1.1 : Standardised concrete Mix M30 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Stilt / Ground Floor
c) In First Floor.
d) In Second Floor.
e) In Third Floor.
f) In Fourth Floor.
g) In Fifth Floor.
h) In Sixth Floor.
9.2.1.1: Brick work in Cement Mortar 1:6 (One of cement and six of Crushed stone sand) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Stilt / Ground floor
b. In First Floor
c. In Second Floor
d. In Third Floor
e) In Fourth Floor.
f) In Fifth Floor.
g) In Sixth Floor.
10.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 110mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² in the following floors a. In Foundation and basement
c. In First Floor
d. In Second Floor
e. In Third Floor
f. In Fourth Floor
g. In Fifth Floor
11.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 70mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors b. In First floor
c. In Second floor
d. In Third floor
e. In Fourth floor
f. In Fifth floor
12.1.1 : Brick partition work in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick (using crushed stone sand) with Admixture a. In Ground floor
b. In First floor
c. In Second floor
d. In Third floor
e. In Fourth floor
f. In Fifth floor
14.1.1.II : Precast cupboard slab 40mm tk using standardised concrete mix M30 grade.(using crushed stone sand) a. In Foundation & basement
15.1.1: Cuddappa slab 20 mm tk.for C/B slab. (using crushed stone sand) b. In First floor
c. In Second floor
d. In Third floor
e. In Fourth floor
f. In Fifth floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d. For Vertical wall
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
23.1.1 : TW styles & rails with 9mm thick BWR single leaf shutters with brass screws a. 900 x 2100 mm
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) including plasticizer
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles using Grout (Tile Joint Filler) (antiskid) (using crushed stone sand)
32.1.1: Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx23cmx20mm thick laid over weathering course in cm 1:3 (One of cement and three of crushed stone sand) 12mm thick mixed with Water proofing compound at 2%
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) including plasticizer
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) including plasticizer
35.1.1 : Plastering in CM 1:3, 12mm with WPC (using crushed stone sand) including plasticizer
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.7 : Plastic Emulsion PAINT including primer for inner walls
38.7.1 : Plastic Exterior Emulsion PAINT including primer for outer walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.1: Rain water harvesting using defunct borewell and providing perforated cover slab (M30) a). Providing pit
b) Augering 30cm dia
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
50.2.1 : Providing precast Kerb stone in C.C. 1:3:6, 450 x 300 x 150 mm (using crushed stone sand)
50.3.1 : Supply and planting avenue trees (using crushed stone sand)
50.5.1 : Supplying. Fabricating and erection of M.S Scheme Name board (using crushed stone sand)
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.4 : S&F of C.I Manhole cover 60 x 60 cm (50kg weight )
53.5.2 : Wash Hand Basin of size 550 x 400 mm (White without Pedestal)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.4.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F.(using crushed stone sand)
57.1.2 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4: Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.5.1 : Gully Trap using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
71.2 : Supplying and fixing of 32 AMPS Triple pole main switch.
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.8 : Run of 4 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
98.3.1 : TW panelled door shutter (with brass fittings) a. 1000 x 2100mm. (Single leaf)
112.1 : S&F of 225 mm dia sweep AC exhaust fan
344.2 : S&F of Bevelled edge mirror 600 x 450 x 5mm
361.1 : Concrete designer tiles flooring (using crushed stone sand)
379.4.2.1: Supply and fixing of Granite slab of size 4'x2', 18 to 20mm Thick for kitchen arrangements (Jet black) laid over in CM 1:3 (One of cement and three of crushed stone sand) 20mm thick a) In Ground Floor
b) In First Floor
c) In Second Floor
d) In Third Floor
e) In Fourth Floor
f) In Fifth Floor
383.4.1 : S&F of stainless steel sink 600 x 450 x 200mm
448.2: Supply and fixing 32mm dia PVC Tee with end cap
ANNEXURE - II A1: Supplying and fixing of SFRC manhole Cover with frame of size 600mm x 600mm with locking arrangements including of all cost etc., all complete and as directed by the departmental officers.
A2: Supplying and fixing of LED blubs suitable for fixing it to pendent / bakelite battern holder of best approved variety a) 9 watts LED bulb
b) 12 watts LED bulb for bulk head fittings
A3: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A4: Supply and fixing of LED Bulk head fitting for 12W LED Bulb
A5: Supplying and fixing of 30W LED Street light with necessary fittings (Superior variety) Charges for fixing 30W LED lamp street light fittings
A6: Providng one coat of Wallputty for new plastered surface
A7: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free.
A8: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free.
A9: Supply & laying flooring tiles for colour Double Charged Vitrified Tiles 600 x 600 x 8mm with 1st Quality homogeneous Full body tiles for flooring and other similar works in cement mortar 1:3 (one of cement and three of CS sand) 20mm thick including fixing in position, cutting the tiles to the required size wherever necessary pointing the joints with grout (Tile joint filler), curing, finishing etc.,
A10: Supplying and fixing of bare galvalume sheet 0.47mm thick roofing with required bolts & nuts and including conveyance etc., all complete.
A11: Supplying and fixing of (16 Persons capacity) 1088 Kgs Passenger Lift MRL, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD. (AMC cost at the rate of 5% the cost of lift for the first year after expiry of warranty period and for further 5 years at the rate of 5% increase for every year over the rate of previous year) Rate + 5% (1st year) (G+5)
A12: Lift Annual maintenance charges for 2nd year
A13: Lift Annual maintenance charges for 3rd year
A14: Lift Annual maintenance charges for 4th year
A15: Lift Annual maintenance charges for 5th year
A16: Supply and run of 2 of No.8 tin coated copper for earth connections to the indidual tenements from the earth bus.
A17: Supplying, Fixing and testing and commissioning of MCCB / MCB / Isolator 40 A TPN 10 KA MCB
A18: Supplying, Fixing and testing and commissioning of MCCB / MCB / Isolator 10/20/32A DP MCB
A19: Supplying, Fixing and testing and commissioning of MCCB / MCB / Isolator 63A TPN MCB
A20: Providing and fixing 25mm x 6mm tin coated copper flat on wall with necessary supports for termination of earth connections in the lift machine room.
A21: Supply and fixing of following UG cables on Walls / Ceiling, including charges for conveying and fixing of UG cables of sizes 4 to 25 Sqmm of 2, 3,3.5 and 4 core with necessary MS clamps, brass screws including cost of all materials redoing the dismantled portion, etc., all complete. a) 3.5 Core 25 Sq.mm UG Cable
b) 2 Core 10 Sq.mm UG Cable
A22: Supply and fixing the following copper Crimping Lugs suitable for the UG cable etc to complete. a) 3.5 Core 25 Sqmm Cable crimping lugs
b) 2 Core 10 Sqmm Cable crimping lugs
A23: Supply and fixing the following copper Cable Gland suitalbe for the UG cable etc., all complete. a) Cable gland suitable for 3.5 Core 25 Sqmm Cable
b) Cable gland suitable for 2 Core 10 Sqmm Cable
A24: Supplying and errection of 58.5 KVA Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications With Standard Control Panel.
A25: Plate earthing with copper plate of size 600 x 600 x 3 mm as per the ISI specification with an earth electrode of 2.1 mtr class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. (for neutral earthing)
A26: Supplying and laying of Rubber Moulded Hydraulic Pressed Paver Block of 63mm thickness and crushed stone sand filling for pointing of approved quality and make suitable colour including cost of conveyance of Paver Blocks and labour charges for laying to proper level, slope etc.,
A27: Supplying and fixing of 4 way Distribution board including 2 Nos of 16 amps MCB, 2 Nos 10 amps and 4 Nos 6 amps, 40 amps ELCB four pole, rotary switch - 3 Nos, Indicator - 3 Nos, including all materials and labour charges etc, supplying and fixing in position of wall making good of the concealed portion with earth connection etc., all complete and as directed by the departmental officers.
A28: Supplying and Fixing of Aluminium Dye Cast Letters of approved size and colour. The colour treatment process is achieved with RF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes a) Aluminium Dye Cast Letters 9’’ size (Tamil)
b) Aluminium Dye Cast Letters 6’’ size
c) 18" Emblem Logo
A29: Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing
A30: Drilling of Bore wells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling betonies and water required for drilling at site (Site will be shown by the departmental Officers) including construction of mud pit. a) Drilling of 140/150 mm pilot bore Upto 150 M
b) Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the departmental officers. i) From 0 m upto 60 m Depth ending from ground level
ii) From 60 m upto 90 m Depth ending from ground level
iii) From 90 m upto 120 m Depth ending from ground level
A31: Labour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers From 150mm dia Casing Pipes assembly
A32: Supplying, delivery and erection of PVC Casing Ribbed screen pipe suitable for 150 mm dia borewell as per IS 12818/2010 for Bore well including etc, all complete and as directed by the departmental officers.
A33: Supply and fixing 160 mm PVC end cap for approved materials including etc, all complete and as directed by the departmental officers.
A34: Supply and delivery of Three phase 3 HP openwell submersible motor with pumpset (lpm 200x 25m)
A35: Supplying and delivery of Three phase 3 HP borewell submerssible pumpset etc.,all complete (150X40) lpmxm
A36: Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable etc., all complete. upto 5HP
A37: Supply and delivery of Three phase panel Board with two level guard auto start with ISI mark for single phase wall mounted type with ammeter, Voltmeter, Indicating lamps ON/OFF push bottons with necessary controls for submersible pump set running preventor relay suitable for the above including wire for fixing sensor and main switch. a) For 3 HP pumpset
A38: Supply and delivery of 3 core 4 sqmm 1100V grade copper UG flat cable of best and approved quality having ISI mark etc., all complete
A39: Supply and delivery of Nylon rope of best and approved quality for tying the delivery line with submersible pumpset for safety measure etc., all complete.
A40: Supplying and laying of the 32mm dia UPVC column pipe for submersible motor etc., all complete
A41: Supplying and delivery of following Dia PVC Pipes below G.L a) 50mm PVC 10 Kg/Cm² pipe
b) 40mm Dia PVC Pipe 10 Kg/Cm²
c) 32mm PVC pipe for submerssible flat cable
A42: Supplying and laying of following dia GI pipe "B" Class of best and approved quality having ISI mark including cost of coveyance and delivery at site of work including earth work excavation, laying charges and cost of specials etc., all complete and as directed by the departmental officers. (Below GL) a) 65mm Dia GI Pipe 'B' Class
b) 50mm Dia GI Pipe 'B' Class
A43: Supplying and delivery of following dia PVC specials including cost of specials with ISI mark of best quality conforming to IS Specification. a) 50mm dia PVC Coupling
b) 50mm dia PVC Elbow
c) 50mm dia PVC Tee
d) 50 x 40 mm dia PVC Reducer
e) 40mm dia PVC Elbow
f) 40mm dia PVC Coupling
A44: Supplying and delivery of following dia GI/CI/GM specials including cost of specials with ISI mark of best quality conforming to IS Specification. a) 50mm dia G.I Bend
b) 50mm dia G.I Union
c) 50mm dia G.I Hex Nipple
d) 50mm dia Foot Valve CI with stainer
e) 50mm dia G.I Tee
f) 50mm dia GM Non-Return valve
g) 32mm dia G.I Union
h) 32mm dia G.I Hex Nipple
i) 100mm dia G.I Bend
j) 100mm dia G.I Coupling
k) 100mm dia G.I Equal Elbow plain
l) 32mm dia GM Gate valve
m) 50mm dia GM Gate valve
n) 25mm dia GM gate valve
A45: Supply and fixing Bib cock with health facet with ISI mark including cost of labour charge and etc., all complete and as directed by the departmental officers.
A46: Supplying and fixing of CP shower arm with shower Rose including cost of labour charge and etc., all complete and as directed by the departmental officers.
A47: Supplying and fixing of CP flange angle cock including cost of labour charge and etc., all complete and as directed by the departmental officers.
A48: METERING PANEL FOR 8 SERVICES (6 FLATS + 1 COMMON) Suitable for 15 PC/HC (1 Block of 15 in 1, S+5) Supply and erection of 125 Amps capacity floor mounting metering panel board (Cubical type) of size 5.5'X6.5'X1' with bus bar chamber made up of 16 SWG MS sheet for 3 phase 4 wire system with 25mm x 3mm tin coated copper flats for phases and neutral; individual metering chamber and with 2 Nos. 25 x 3mm GI flat for the earth bus on the supply and use)
A49: Supplying and Laying of specified aluminium LT UG Cable on Below Ground Level and above level to be at a depth of 0.75 m put in 0.15 m layer of sand and covering the cable completely with bricks and sand refilling the earth to good including cost of all materials and labour charges etc., a) 3.5 core 120mm sqmm from EB pole to meter pannel
A50: Supply and fixing of brass cable gland suitable for 3.5 core 120 Sq.mm with earth strips around the cable termination with crimping of terminals with lugs etc (for Incoming Cable).
A51: Supplying and laying of 300mm dia RCC Hume Pipe with ISI amrk of best quality etc., all complete and as directed by the departmental Officers.
A52: Supplying and fixing of following Dia GI pipe of best and approved quality having ISI mark including cost of coveyance and delivery at site of work etc., all complete and as directed by the departmental officers. (Above GL) a) 100mm Dia GI Pipe 'B' Class
A53: Supplying and fixing of 100 Amps Three Phase 500V 4 Pole Change Over Switch including cost of labour charges etc., all complete and as directed by the departmental officers.
PTM PROJECTS PVT LTD (BID ID -1226175)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .