| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹28.8 L+₹1.6 L (6.01%)Rejected-Finance NO 4 AC 114 EAST OF NGEF OPP THE KARNATAKA STATE APEX CO OPERATIVE BANK KASTURI NAGAR BANGALORE 560043 | BANGALORE | BANGALORE | KARNATAKA | 560043 | L2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹49,000
Closing Date
29 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
CERTAIN B R AND E M MAINTENANCE REPAIR WORKS AT MD OTM ACCN OF NTG NLC AND HQ NAVAL DET UNDER GE NORTH BANGALORE
2021_MES_456944_1
8238
Open Tender
Civil Works
Item Rate
180 days
GE North Bangalore
Class E category a(i) b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹49,000
Yes
13 Sept 2021
3 Jul 2021
31 Jul 2021
3 Jul 2021
29 Jul 2021
17 Jul 2021
3 Jul 2021 - 16 Jul 2021
90 days
Amount
PART I (B/R WORKS)
Dismantling wall and ceiling boards, fibre, pulp, insulation, etc., or insulation boards / slabs / blankets, any thickness, including cover fillets etc complete all as specified and as directed.
Demolition of brick work /stone masonry / PCC block masonry built in cement mortar of any description all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not specifically provided for complete etc all as specified and as directed.
Dismantling water tanks of any type and removing to store, capacity exc. 250 litres and not exc. 500 litres all as directed.
Taking up or down steel tubing 15mm dia and connections including cleaning for refixing or removal to store all as directed.
Taking up or down steel tubing 20mm dia and connections including cleaning for refixing or removal to store all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the the premises complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc., laid bedded and pointed in any cement mortar including removing off the premises etc complete all as specified and as directed.
Taking down cement plaster of any description including raking out joints, hacking for key and disposing of debris to a distance exc 1 Km out side MD land complete all as specified and directed.
Taking down chowkat (without taking of shutter from the frame) area not exc. 1.5 sqm each including making good the disturbed surface in PCC(1:2:4) type B0 or CM (1:3) all as specified complete all as specified and directed.
Taking down chowkat (without taking of shutter from the frame) area exc. 1.5 sqm and n.exc. 4 sqm each including making good the disturbed surface in PCC (1:2:4) type B0 or CM (1:3) all as specified and as directed.
Hacking out old broken glass of any thickness, size, quality or description from metal / wooden frame works or stone / concrete/ brick surrounds including punching or drilling out old glazing pins/spring clips or fixed with wooden beading etc complete all as specified and as directed.
Taking down PVC /Cast Iron as in soil / waste pipe / rain water pipes ( any size or pattern) including all fittings head shoes etc complete all as specified and as directed.
Decorated PVC false ceiling of size 600mm x 600mm x 5 mm thick, used as a panel insert in a frame work made out of using anodized aluminum T-section of size 25mm x 25mm in square pattern of grid size 600mm x 600mm, the aluminum frame work shall be supported from the ceiling with the help of J hook and 4 mm GI wire of required size to maintain the proper levels etc., the aluminum frame work is supported on side wall with the use of aluminum L section of size 25mm x 25mm angle complete all as specified and as directed.
Plain Cement Concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in sub base to floors, 75mm thick complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floors 25mm thick, as in levelling course of flooing complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.36 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Vitrified light coloured ceramic tiles 8-10mm thick (square/rectangular) polished, area of each tile not exc. 0.36sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) for layaing floor finishes complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces/dado 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick in CM (1:3) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
All as per Sl Item No. 1.019 above but as in skirting.
18 to 20mm thick Granite stone slab (of any type) work, table rubbed and polished in steps, jambs, pillars, window-cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including grinding the edges half round and polishing including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Cement concrete designer chequered tiles of exterior grade, coloured, glossy finish, rubber pressed of size 300mm x 300mm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floors etc., 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Factory made pressed steel frames of size 165mmX60mmX1.25mm for doors with one or more rebates(02 rebates) including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and as directed.
35mm thick flush shutters of solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed
Second class hard wood 35 mm thick factory made glazed and skeleton shutters open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and as directed.
PVC solid frame, single rebated of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete as sepecified and directed. NOTE:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
Factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face etc. complete all as specified and as directed.
Powder coated aluminium frame for doors, windows, ventilators (minimum thickness of powder coating 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
Powder coated aluminium window and ventilator shutters (minimum thickness of powder coating 50 micron), fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified NOTE:- Glass and wire mesh shall be measured and paid separately under respective items.
Powder coated aluminium door shutters (minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc., complete all as specified and as directed. Notes.Glass shall be measured and paid separately under respective items.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples etc complete all as secified and as directed.
Plain sheet glass 4mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane and all as specified and as directed.
4.00 mm thick figured glass , pin headed type and glazing with oil putty in square not exc. 0.50 sqm each pane complete all as specified and as directed.
5.50mm figured glass including fixing to any size and pannel etc., fixed in repairs complete all as specified and as directed.
Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed.
Aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc., complete all as specified and as directed.
100 mm thick stainless steel butt hinges, medium weight, and fixed etc complete all as specified and as directed
150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed.
150 mm long floor door stoper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor etc complete all as specified and as directed.
Mild steel 300mm long, ordinary rat tail rod pattern springs,including roller and roller plate complete fixed in repairs complete all as specifed and as directed.
Aluminium (extruded section body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
Precast Cement concrete, type (1:3:6) using 20 mm graded stone aggregates with solid blocks, exc 10 cm in width and setting in CM (1:6) all as specified and as directed.
Rendering 5mm thick on concrete surfaces of ceiling / chajja / facia of chajja etc in cement morter (1:3) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under reelvent items.
Supply only integral liquid water proofing compound all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in copings, chajja kerbs, roof padding / staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Demolition of existing roof treatment of any type including cement plaster 10 mm thick and PCC 25mm thick and providing screed bed/rendering 10mm thick in CM (1:4) mixed with and including supply of approved water proofing compound as per manufacturers instructions over and including 25mm thick (average) PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and providing 50mm x 50mm coving at the corners with PMC mortar as above, and applying APP modified water prrofing membrane as per IS 1654-2017/IS 16352-2017 mineral finish, 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm complete all as specified and directed.
Galvanised iron pipe of 15 mm dia, medium grade, laid in floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
Galvanised iron pipe of 20 mm dia, medium grade, laid in floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs complete all as specified and as directed.
20mm dia Ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) all as specified and as directed.
Vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, 32 mm bore wastepipe, stainless steel coupling and LDPE pipe 600 mm long fixed in repairs complete all as specified and as directed.
Vitreous china wash down water closet pan (pedestal pan) including fixing bolts, flush pipe anti syphonage pipe, plastic water closet seat, black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete of cera model cat pt no. 2008 fixed in repairs complete all as specified and as directed
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC(SWR) 'P' or 'S' trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor fixed in repairs complete all as specified and directed.
Viterous China urinals, bowl type (back or corner wall type), complete fixed in repairs including providing and fixing plugs, beddings urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; supply and fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed.
15mm bore pillar taps fancy type, cast copper alloy, with long swan neck , chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs all as specified and as directed.
Bib taps, 15 mm dia bore fancy type, cast copper alloy, chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed in repairs complete all as specified and as directed.
Brass CP wall mixer for mixing hot and cold water screwed down for iron pipe and fixed in repairs complete all as specified and directed (Cat No-7875 URBONA series of Prayag or equivalent make as specified in CA)
Sink mixer with swinging casted spout (wall mounted model) with connecting legs and wall flanges of 15 mm bore etc fixed in repairs complete all as specified and as directed (Cat No-7875 URBONA series of Prayag or equivalent make as specified in CA)
15 mm dia single lever basin mixture tall height without pop up waste system fixed in repairs all as specified and as directed.(Cat No PIS-7852 URBONA series of Prayag or equivalent make as specified in CA)
Brass chromium plated shower roses 125 mm size with or without swivel joints of standard size including fixing to 15mm steel pipe or union fixed in repairs complete all as specified and as directed
15mm bore stop/angle cock, cast copper alloy CP, fancy type high presure with capstan head handle,weight not less than 450 gms screwed both ends for iron pipe of for unions fixed in repairs complete all as specified and as directed.
Health faucet, brass body, chromium plated with 1mtr long SS braided tube & wall hook all as per Prayag Cat No-BEA-41/BEA-85 or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Jet spray, brass chromium plated suitable for EWC / Ango Indian EWC including fittings fixed in repairs complete all as specified and as directed.
Towel rail, stainless steel glossy finish all as per Prayag Cat No-BA10S or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Unbreakable square wall mounted shelf of 500mm size all as per Prayag Cat No. BEA-47A or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Corner shelf unbreakable (3Pcs set i.e 8"-1, 10"-1 & 12"-1) all as per Prayag Cat No. BEA-44A or techno commercially equivalent make specified in PS fixed in repairs complete all as specified and directed.
Toilet paper holder all as per Prayag Cat No. BA-88 or techno commercially equivalent make specified in PS fixed in repairs complete all as specified and directed.
PVC connections 15mm dia with PTMT nuts of length of 450 mm long fixed in repairs complete all as specfied and as directed.
PVC urinal waste pipe 32mm dia 800mm long, fixed in repairs complete all as specified and directed
75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement fixed in repairs complete all as specified and as directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete fixed in repairs complete all as specified and as directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints laid in floors with necessary fittings complete all as specified and as directed.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints laid or in floors with necessary fittings complete all as specified and as directed.
110mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
75mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
110mm bore PVC (SWR) branch piece (single Y), type 'B' equal or unequal with access door complete all as specified and as directed.
Preparation of new or previously untreated wooden surfaces of any description not other wise described over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of old painted wooden surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of old painted surfaces of steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
Preparing new plastered suface of walls and applying two coats distemper oil emulsion, white or tinted over a over a coat of alkali resistance primer etc complete all as specified and as directed
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer all as specified and as directed.
Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and directed.
Complete removal of existing treatment by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface incl rubbing and washing etc and applying two coats of distemper oil emulsion, white or tinted on walls over a coat of alkali resistance primer incl 2 mm wall care putty etc complete all as specified and as directed.
Preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat distemper oil emulsion, white or tinted complete all as specified and as directed.
All as per Sl Item No 1.090 above, but two coats of distemper oil emulsion, white or tinted complete all as specified and as directed.
Preparation of plastered or un plastered old decorated surfaces of ceiling by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat of white wash complete all as specified and as directed.
Preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat of white wash complete all as specified and as directed
Preparation of old treated plastered wall surfaces of any description and applying one coat of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) including filling the cracks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
Complete removal of existing treatment on wall surfaces of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the cracks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
Stainless steel decorative curtain rod of 25 mm bore with wood finishes (weight not less 400 gms per running meter) incl fancy finale caps fixed in repairs etc complete all as specified and as directed.
Brackets for curtain rod of dia 25 mm dia made out of SS flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with rawl plug of size not less than 50 mm long incl wooden base etc fixed in repairs complete etc all as specified and as directed.
Removal of sludge from septic tanks / manholes of any size and depth, burrying the sludge in pits with suitable depth and filled by earth including removal of surplus matrials and dewatering of water to a place as earmarked by state auth out side the defence land complete all as specified and as directed. . Note - Dewatering of water or mud will not be paid seperately only sludge to be paid for the above item.
Clearing and removal of all blockage in sewage line from manhole to manhole, any dia of sewer lines, manholes of any section and any depth, in any situation by way of cleaning / desludging foreign materials as well as blockage of sewage line in between successive manholes manunally / mechanically including desludging of manhole /sewage line where required and odered by Engineer-in-charge and keeping sewer line functional, upto final drop/outlet into septic tank /central sewage system terminating in other joining zone/ area or into sewage wells complete all as specified and as directed. NOTE FOR SL ITEM NO. 1.098 AND 1.099 :- (a) Contractor shall detail his supervisor to office of AGE B/R MEG daily by 9.00 AM who will report to concerned JE B/R /Engineer-in-Charge to receive all complaints of entire area under this contract
NOTE FOR SL ITEM NO. 1.098 AND 1.099 :- (b) Contractor shall provide service providers (sweepers) to the complaint cell located at Naval area Garrison as per the complaints list given alongwith all requisite tools, equipments, including saftey measures for attending complaint and ensure completion report by 5.00 PM same day. (c) Please note that all the complaints relating to sewage line shall be attended within same day (within 12 hour). In case of blockage in sewage line could not be detacted/completed same day and concerned JE / Engineer-in-Charge is satisfied to the efforts applied but the same shall be attended and all blockage must be cleared by 24 hours (next day by 5.00 PM) without fail. (d) Complaint/blockage cleared in one building in a day may be for WC, bath, kitchen, floor/nahani traps etc shall be treated as one complaint. (e) In case any complaint pertaining to clearing of blockage in sewage line is not removed /cleared within 24 hours (next day 5.00 PM). A penalty @ Rs. 200/- per complaint shall deducted from contractor payments.
Mechanically pumping out sewage liquid from septic tanks / manholes of any size and depth, removal of the same to a distance / place as earmarked by state auth out side defence land including any type of T & P required for dewatering of water complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in hard / dense soil etc complete all as specified and directed.
Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed.
Removal of excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting pointcomplete all as specified and as directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe complete all as specified and as directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 200 mm internal dia of pipe complete all as specified and as directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 300 mm internal dia of pipe complete all as specified and directed.
Taking down PVC, soil and waste pipe up to 300 mm dia (any size or pattern) including all fittings head shoes etc complete all as specified and as directed.
Plain Cement Concrete as in foundation filling and mass concrete (1:4:8), type D-2, using 40 mm graded stone aggregate complete all as specified and as directed.
Reinforced Cement Concrete pipes, class NP3, of 150mm dia laid in trenches and jointed complete with collars all as specified and directed.
Reinforced Cement Concrete pipes, class NP3, of 200mm dia laid in trenches and jointed complete with collars all as specified and directed.
Reinforced Cement Concrete pipes, class NP3, of 300mm dia laid in trenches and jointed complete with collars all as specified and directed.
150mm bore PVC (SWR) pipe, type 'B' , single socketed in any length with rubber ring joints laid in trenches or in floors etc., complete all as specified and as directed.
All as per Sl Item No. 1.113 here in before but 200 mm dia bore of pipes.
All as per Sl Item No. 1.113 here in before but 300 mm dia bore of pipes
PlainCement Concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested suitable for 150 mm bore of pipe complete all as specified and directed.
PlainCement Concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested suitable for 200 mm bore of pipe complete all as specified and directed.
PlainCement Concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested suitable for 300 mm bore of pipe complete all as specified and directed.
Plain Cement Concrete (1:2:4), type B1 using 20mm graded stone aggregate as in surfaces channel and drains etc., complete all as specified and directed.
Demolition of Reinforced cement concrete in ground floor and pavings n.exc. 15cm thick (below or above ground level) complete all as specified and directed.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar 1:6 type C1 1:3:6 ( using 20 mm graded aggregate) complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete (1:2:4), type B-1 smooth finished and reforming benching as required suitable for 150 mm internal dia of pipe complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete (1:2:4), type B-1 smooth finished and reforming benching as required suitable for 200 mm internal dia of pipe complete all as specified and as directed.
Precast Reinforced Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in cover slabs of man hole including necessary form work set in CM (1:4) complete all as specified and as directed.
TMT steel bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
TMT steel bars 6mm to 8mm dia, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Cleaning of sewage pipe line of 100mm bore by means of rodding / sewage cleaning machine / compressors if required and clean out the sludge / liquid mud or any other obstruction material including working in foul conditions and disposing of sludge /silt / liquid mud beyond the premises of MOD land etc complete all as specified and as directed.
All as per Sl Item No. 1.128 above but 150 mm dia bore of pipe
All as per Sl Item No. 1.128 above but 200mm dia bore of pipe
All as per Sl Item No. 1.128 above but 300mm dia bore of pipe NOTE FOR SL ITEM NO. 1.099 To 1.131:- the work shall be required to be carried out in foul / flowing of sewage water condition. Contractor shall provide all safety gear / eqpt to sewage labour, while they are working under manhole/septic tank to avoid any untoward incident / accident. Contractor shall quote his rate accordingly and nothing extra shall be admissible on the account.
Pre painted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strenght of 550 MPa as in roof covering / Cladding to walls, fixed with self tapping screw all as specified and as directed
Steel work as in tubular trusses including special shape washer complete using ERW or induction butt welded tube confirming to IS-4923 as in col, rafter and purlins etc complete all as directed.
Disconnecting existing tank, keeping aside (or lowering if required) of capacity 500/1000 ltr capacity for repairs, cleaning etc including cleaning and removing all scale and dirt etc from tank and from mouths of circulating pipes including writing the date of cleaning and refixing in same position etc complete all as specified and as directed.
PART II (E/M WORKS)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan,call bell socket or power circuits) including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., complete and making good the disturbed surface of walls, ceiling etc., including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete concealed with 1.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked including accessories concealed in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for one light point controlled by one switch.
All as per Sl Item No. 2.002 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.002 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.002 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on same board.
Point wiring complete concealed for modular type switch & sockets with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concelaed type wiring includign GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 2.008 here in before but for one fan point controlled by one switch/regulator
All as per Sl Item No. 2.008 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.008 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring complete surface type with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including PVC Casing & Caping ISI marked with accessories surface type wiring including 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed one light point controlled by one switch.
All as per Sl Item No. 2.014 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.014 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.014 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.014 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.014 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring concealed complete with 2.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium density ISI marked with accessories concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring (modular) complete concealed with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. NOTE FOR Sl ITEM NO. 2.002 to 2.021 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten suitable for indoor applications 18/20 Watts,4 feet with polycarbonate housing and integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.BCLAB 20 WH LED P / Havells Cat No: LHEXAPP7IN1W020 / C&S Cat no: LTTB4F20W LED EW BATTEN complete all as specified and as directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No. BCLAB 10 WH / Havells Cat No: LHEXACP5IN1W010 of Havells / C&S Cat No:LTTB2F 10WLEDW BATEN all as specified and as directed.
2' x 2' Recess mounted LED luminaire of capacity 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings all as per Bajaj Cat No : BZRSQL 36W GZI WH / C& S Cat No. LTCRSLM36WATT2X2 or techno commercially equivalent makes specified in PS complete all as specified and as directed.
1' x 1' Recess mounted LED Luminaire 24 Watts white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with all accessories all including taking out old fittings all as per Bajaj, Cat No : BZSSQL 24W LED WHI or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Bulk head fittings of 10 watt, IP -65 type luminaries complete with all accessories including taking out old fittings all as per Bajaj Cat No: BIBWP 10 W LED of BAJAJ or or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Modular switch 1 way, 6 Amps, one module complete all as specified and as directed.
Modular switch 1 way 16 Amps, one module complete all as specified and as directed.
Modular switch 2 way, 6 Amps, one module complete all as specified and as directed.
Modular bell push, 1 way, 6 Amps, one module complete all as specified and as directed.
Modular socket, 6 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular socket, 6 Amps / 16 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular fan regulator, five stepped, 120 Watt, 2 Module complete all as specified and as directed.
Switch piano flush button single pole two way 5 Amps with ISI marked complete all as specified and as directed.
Angle holder PVC/polycarbonate type all as specified and as directed.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Socket outlet 2 in 1, 3 & 2 pin 5 Amps all as specified and as directed
Bell push flush type, one way 5 Amps all as specified and as directed.
MCB single pole and neutral 240 Volts, 32 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB single pole 240 Volts, 6 to 32 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB TPN 415 volts 63 Amps including taking down the existing complete as specified and as directed.
MCB DB SPN 4 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB SPN 8 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
Stepped type electronic fan regulator flush Switch/Socket type including taking down the existing complete as specified and as directed.
Ding dong bell AC 230 volts single pole including taking down the existing complete as specified and as directed.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 6 sq.mm, earth continuity conductor of size 6 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors complete all as directed. NOTE:- Two wires of 6 sq.mm and one wire of 6 sq.mm and one run of PVC conduit shall be measured as one unit.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 4 sq.mm, earth continuity conductor of size 4 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors complete all as directed. NOTE:- Two wires of 4 sq.mm and one wire of 4 sq.mm and one run of PVC conduit shall be measured as one unit.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
30 Watt LED building security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings all asper Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or techno commercially equivalent makes specified in PS complete all as specified and as directed. .
Brackets made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc., applying two coats of aluminum paint over a coat of red oxide primer before fixing including removing the old existing GI bracket from building complete all as specified and as directed.
Sheet metal enclosure single pole and neutral with a two pin earth plug and socket with one single pole MCB 20 Amps, 230 Volts AC complete all as specifeid and directed.
Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling and reinstallation on the / at the same location including hydraulic pressure testing of container with hand operated hydraulic pump complete after necessary repair / replacement of old parts, brazing inner tank complete all as specified and as directed. NOTE:- Replacement of old parts shall be measured and paid separately.
Supply only stainless / Mild steel inner tank of capacity 25 ltrs unit with internal assembly complete fitting and fixtures of any type and size all as specified and as directed.
Supply only heating element of 2 KW rating triangular/round type including rubber washers all as specified and as directed.
Supply only heating element of 2 KW rating hexagonal / spiral type all as per existing size and type including rubber washers all as specified and as directed.
Supply only thermostat suitable for 25/50 Ltrs capacity Geyser all as specified and as directed
Supply only Indicator lamp red and green type square/round suitable for 25/50 Ltrs capacity Geyser all as specified and as directed
Supply only safety valve/high pressure valve ISI marked suitable for 25/50 Ltrs capacity Geyser all as specified and as directed
PVC insulated copper cable flexible 3 core of size 2.5 sq.mm ISI marked complete all as specified and as directed.
Supply only outer cover suitable for geysers of 25 ltrs capacity complete with all fittings and fixtures all as specified and as directed.
Supply only PVC flexible pipe (set of two) 16mm dia 450mm long with 2 Nos of brass ferrule and rubber washers for hot and cold water all as specified and as directed.
Preparation of old painted surfaces of the geyser of any type and capacity complete after cleaning and applying one coat of spray paint(DUCO) of same shade with synthetic enamel paint, writing MES No with approved stencil including taking down and refixing in the same or other location complete all as specified and as directed.
Taking down ceiling fan 1200mm/1400mm sweep and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint(DUCO) including writing MES No with approved stencil and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
Inspection, disconnecting electric connections and dismantling ceiling fan / exhaust fan /wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tightening of nuts and bolts and refixing on the the same complete after necessary repair/replacement of old parts all as specified and as directed. NOTE :- Replacement of old parts shall be measured and paid separately.
Supply only ball bearing of various sizes / make as required for ceiling fans/exhaust fan including greasing complete all as specified and as directed.
Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed.
Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust fans complete all as specified and as directed.
Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust fans complete all as specified and as directed.
PVC flexible cable twin twisted core of 23 / 0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust fans complete all as specified and as directed.
Rubber bush with MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed.
Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling / opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling / opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Taking down exhaust fans 300mm / 450mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint(DUCO) including writing MES No with pproved stencil and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
Dismantling /opening the exhaust fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. NOTE FOR Sl ITEM NO. 2.075 to 2.077, 2.079 & 2.080 :- Cost of spares will be measured and paid separately under relevant items.
Extension of down rod suitable for ceiling fans height upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
PVC fresh air fan of 250/300mm sweep, 1200/1400 RPM with louvers all as per Havells Cat No. Ventil air -DX or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable and taking down the existing fan all as specified and directed.
Motor with blades suitable for exhaust fans upto 280 mm sweep of any make and type, heavy duty, 1400 RPM, AC, single phase, 230/240 Volts complete including taking down the existing all as specified and directed.
Motor with blades suitable for exhaust fans 300 mm sweep of any make and type, heavy duty, 1400 RPM, AC, single phase, 230/240 Volts complete including taking down the existing all as specified and directed.
Outer frame for holding exhaust fan motor with supporting angle suitable for existing exhaust fans up to 280 mm sweep of any make and type complete including taking down the existing frame all as specified and directed.
Outer frame for holding exhaust fan motor with supporting angle suitable for existing exhaust fans 300 mm sweep of any make and type complete including taking down the existing frame all as specified and directed.
Removing the window type AC / split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, replacement of burnt out wiring terminals, cleaning the air filter, adjusting relays etc., replacement of unserviceable spare parts and fixing back at location, testing and commissioning complete all as specified and as directed.
All as per Sl Item No. 2.087 here-in-before, but for water coolers of 40 /60/ 80 ltrs capacity.
Labour only for charging of refrigerent gas (R-22/410A/134A) of required quantity for split/window type AC of 1.50 ton capacity including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing all as specified and as directed.
All as per Sl Item No.2.089 here-in-before, but for capacity of 2.0 ton AC.
All as per Sl Item No. 2.089 here-in-before, but for water coolers of 40 /60/ 80 ltrs capacity.
Painting of water coolers of 40 / 80 ltrrs capacity with two coats of synthetic enamel paint of existing colour all as directed over a coat of primer after welding the base plate with MS angle iron frame of existing size removing dust, tinkering, applying metal putty wherever necessary including writing of SM/MES No all as directed by Engineer-in-Charge.
Removing the unserviceable thermostat, supply and fix new thermostat of same make and type suitable for Split/window type AC 1.5/2 ton capacity all as specified and as directed.
All as per Sl Item No. 2.093 here-in-before, but for water coolers of 40 /60/ 80 ltrs capacity.
Removing the unserviceable potential relay, supply and fix relay of same make and type suitable for water cooler 40/60/80 ltrs capacity.
Removing the unservicable running capacitor of 40 MFD, Supply and fix of new capacitor suitable for 1.5 ton AC of any type and make as existing complete all as specified and as directed.
All as per Sl Item No.1.083 herein before, but starting capacitor of 80/100 MFD suitable for 1.5 TR /2 TR AC.
All as per Sl Item No.1.083 herein before, but starting capacitor of 60/80 MFD for water cooler.
Removing the unservicable over load protection, supply and fix new over load protector suitable for split/window type AC of 1.5/2.0 TR capacity.
Removing the unservicable push cock of any type from water cooler, supply and fix new stainless steel metal push cock 15mm dia of same type complete all as specified and as directed.
Removing the unservicable PVC ball valve 15mm dia including float and replace with new PVC ball valve of 15mm dia suitable for water coolers of any make and size all as specified and directed.
Removing the unservicable PVC flexible pipe, supply and fix new PVC flexible pipe of existing type size for water outlet of water cooler all as specified and as directed.
Disconnecting and removing the damaged unservicable supply cord for cooling appliances, supply and fix new PVC insulated 3 core 2.5 sq.mm multi stranded copper conductor cable complete all as specified directed.
Supply only refrigrent gas (R-22/410A/134A) for domestic cooling appliances complete all as specified and as directed.
Disconnecting and taking out the unservicable sensor / remote unit completely, supply and fix new sensor / remote unit of indoor unit of AC suitable for 1.5 Ton split type AC of any type and make complete all as specified and as directed.
Disconnecting and taking PCB circuit by disconnecting out PCB from split AC of 1.5 / 2 ton capacity, repairing the same and refixing in original location complete all as specified and as directed.
Disconnecting electrical connections, removing copper line, discharge line of split type AC up to 2 Ton capacity including indoor, out door units with all accessories and shifting / reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified.
Plastic / coir filter suitable for split / window type AC 1.5 / 2 ton capacity including taking down old un serviceable filter etc., complete all as specified and as directed.
Energy saving ceiling fans, 230 Volts, 26 Watts, single pole, 1200 mm sweep, high speed of approved colour with remote control and two years warranty certificate from the manufacturers, with latest BEE five star rating and BLDC technology all as per Havells Model No :- Efficiencia Neo (BLDC 26W) or techno commercially equivalent models specified in PS complete with down rod and GI hook with welding work, wire connections from ceiling rose to ceiling fans, with complete accessories including writing of MES No with unit name on ceiling fans using approved stencil with synthetic enamal paint complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr, connected to galvanized strip 25 x 4 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I 2010 and as specified or indicated including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast RCC slab 40mm thick in Reinforced Cement Concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including test point and testing on completion complete all as specified and as directed.
Replacemet of un serviceable existing /suitable size MCCBs 4 pole 415 Volts 50Hz including complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under:- (a) MCCB 125 Amps 36 KA with fixed thermal and magnetic settings.
(b) MCCB 100 Amps, 36 KA with adjustable, thermal setting.
(c) MCCB TPN 63 Amps, 16 KA, 415V, 4 pole.
GI pipe bracket made of 40mm bore light grade GI pipe1.5 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed.
FRP moulded junction box with IP 65 protection of size 300x200x80mm with 32 Amps 4 way heavy duty terminal block with 6 Amps MCB SP and two number of cable entry gland of standard size with suitable MSclamps to fix with pole complete including taking down the existing complete all as specified and as directed.
60 Watt LED street light fitting with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08. 4kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance all as per Bajaj, Cat No.:- ENXT P 72 L WH CR PC SD or techno commercially equivalent make of Havells/ Philips/Crompton all as specified and as directed.
70 Watt next generation LED street fittings with pressure die-cast housing along with prismatic polycarbonate modular secondary lens optics for city road application with IP-66 ingress protection and impact resistance of IKO8, 4KV inbuilt and 10 KV external surge protection with top opening drive cover for easy maintenance all as per Bajaj Cat No.:- ENXT P 84L WH CR PC SD or techno commercially equivalent makes specified in PS includingt aking down old unserviceable HPSV/ HPMV street light fittings complete all as specified and as directed.
90 Watt LED street light fitting with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics with IP 66 ingress protection and impact resistance of IK 07, 5kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance including taking down old unserviceable street light fittings from pole. all as per Bajaj Cat No.BRTFG 90W LED CR or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Two runs of PVC insulated 2.5 sq.mm single core multistranded copper conductor cable and one run of 2.5 sq.mm copper wire as earth continuity conductor drawn through and including rigid non metalic PVC conduit of 20 mm external dia fixed on poles & connecting up all as specified and as directed. NOTE:- Two runs of cable and one run of earth wire and one run of conduit shall be measured as one unit length.
Dismanling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 25 W to 45W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site.
Dismanling and taking out the LED street light fittings any make from pole and removing the burnt out /unserviceable LED driver 45/60 Watt and replacement of new driver to make the fitting serviceable and refixing the same in existing / new location all as directed at site.
45 Watt post top LED light fitting, die cast aluminum graphite, grey powder coated spigot, acrylic clear diffuser, spun aluminum power coated canopy, LED connected in series and parallel combination with better heat dissipation arrangement, LED colour 3000 K + 300K, open and short circuit protection, voltage surge protection 5KV, suitable for 60mm OD pipe entry with fixing bolts, IP-65. all as per Bajaj Cat No. BGCT W4 LED WH or equivalent in Havells/Phillips/Crompton.
LED bollard 10 watt with MS pipe housing glare free PMMA diffuser and IP 65 protection all as per Bajaj Cat No. BGBOL 605 9W LED WH or techno commercially equivalent makes specified in PS complete all as specified and as directed.
S&F in replacement of LED flood light luminaries 50 watt , with ultra sleek, light weight and secondary opticsmade of pressure die cast housing with IP 66 ingress protection and impact resistance of IK 07 inbuilt including channel for fixing of wall with complete fitments, accessories .Make:- BAJAJ BJFL 50W LED I or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Supply, installation, tesing and commissioning in replacement of lithium based solar security light system with bult in battery, PV Panel and LED lamp in FRP body and including taking down old unserviceable light fitting of any size/capacity complete system comprises of following items:- (a) PV Panel 30 W Monocrystalline. (b) Lithium cell for back up 15.4 AH with inbuilt BMS. (c) High brightness W-LED lamps 15W, CRI>700, CCT 6500K. (d) Microcontroller based charge controller cum diriver with automatic dimming dunction, Operation. (e) Working temperature; (-) 10 degree C to (+) 55 degree C. (f) System shall be supplied with adjustable MS clamp and 40 mm dia arm suitable for pole/wall mounting complete with satisfaction of Engineer-in-Charge. Make:- Bajaj/Philips/Havells/Syska/ C&S/CG.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for cable laying / errection of poles and getting in hard/dense soil complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing the excavated material to a distance exc. 50m but n. exc. 100m and depositing where directed at a level n. exc. 1.5m above the starting point.
Sand cushioning in layers for cables in trenches / ducts for cable using dry river sand including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technic and nessary machine including inserting of HDPE pipe of bore 80mm dia, suitable for 0.40 Mpa working pressure including excavation at ends complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 35 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 10 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
Cleaning of UG Sump of following capacities by draining out water, removing the silt / mud from inside, cleaning the internal surfaces of wall / ceiling / floors by using wire brushes, removing silt / sludge, complete drying the floor area by cleaning with anti bacterial agent (solution to be prepared in water @ 0.20 Kg of bleaching powder/ washing soda per sqm of internal area) at internal surfaces for making bacterial free, applying two coats of white wash on whole internal surfaces including making necessary writing the details of date of cleaning of UG sump and next due date of cleaning with synthetic enamel white paint over one coat of black painted surface complete all as specified and as directed by Engineer-in-Charge. (a) Capacity of 5000 gallons at NTG/NLC.
(b) Capacity of 50000 gallons at Naval Detachment
Removing old unserviceable float valve 20 mm bore from service tank supply and fix float valve with PVC body aluminium float rod, nylon float high pressure type complete all as specified and as directed.
Disconnecting the electric cable from the terminal box of 5HP motor, decoupling the motor from the pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop and performing following works as specified and directed by Engr-in-Charge. (i) Dismantling the motor and taking out the burnt out copper winding /fiber strip/insulating materials and worn out ball bearing - 2 Nos. (ii) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fiber strip/varnishing and made terminal connection of fiber glass coated wire. (iii) Replacement of ball bearing - 2 Nos. (iv) Assembling the motor and painting with two coat of primer and one coat of synthetic enamel paint including marking flow of water and MES NO all as per norms and all as specified and as directed as directed by the Engr-in-charge. (v) Transporting to the motor to the site refixing on foundation channel with new bolts and nuts, coupling the pump and motor with correct alignment apply grease and connecting electrical connections testing complete alll as directed and as specified by the Engr-in-charge.
Disconnect the electrical connection, lifting the submersible pumpset with 50mm GI pipe from 500 to 700 feet depth bore well of 03 HP to 7.5 HP capacity and dismantling the pump set and replacing the damaged impeller, bearing, bushes, stainer as per exisiting size and assembling the same including necessary lathe works, fixing the motor and proper insulation ,connecting and testing and lowering the same, testing and commissioning all as directed at site and as specified by the Engr-in-charge.
Removing the defective single phase preventer from star/delta starter, supply and fixing new single phase preventer suitable for 60/40/30/25/20/15/12.5/10/7.5 and 5 HP capacity of motors complete all as specified and as directed. Make :- L&T or equivalent.
Repairs to the star/delta starter of different type fully automatic including replacing with new spares ie. Contactor, timer, relays etc suitable for existing make and capacirty of ML1/ML2/ML3/ML4/ML1.5/MK1. NOTE:- Spares shall be measured and paid separately.
Dismantling the existing old pressure gauge from the pump set/water supply line and provision of new pressure guage 1-10.6 kg per sq cm 100 mm dia dial 3/8" threaded type with stop cock arrangement complete all as specified and as directed.
Dismantling the existing old vacuum gauge from the pump set / water supply line and provision of new pressure guage 0-760 mm Hg pressure 100 mm dia dial 3/8" threaded type with stop cock arrangement complete all as specified and as directed.
Replacement of defective pump shaft as per existing type and size of less than / equal to 7.5 HP pump set capacity complete all as specified and as directed.
Dismantaling the old shaft and performing the necessary work and remetalling the shaft as per existing size of less than / equal to 7.5 HP pump set capacity complete all as specified and as directed.
Supply only starter contactor assembly of ML 1.5 type all as per L & T Cat No. SS91851 or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Preparation of old painted steel surfaces of any description and applying one coat of synthetic enamel paint to external surface of pipes of sizes 200mm / 150mm / 100mm / 80mm / 50mm dia and marking arrows indicating direct flow with approved tint all as specified and as directed.
Replacement of submersible flat copper conductor cable of size 3 core 4 sq.mm complete all as specified and as directed.
Taking out the existing un serviceable LT panel, supply and fixing of new accessories like starter, single phase preventor, fuse cut outs, indicating lamp etc suitable for 5 HP submersible pump set for outdoor application complete all as specified and as directed. Note :- Job includes necessary civil works such as foundation, grounding of panel etc & connecting back existing old cables.
Galvanised iron pipe of 80 mm dia, medium grade, laid in trenches / fixed to walls with all fittings such as socket, bends, elbow, union etc., including dismantling the old un serviceable pipe complete all as specified and as directed.
Galvanised iron pipe of 50 mm dia, medium grade, laid in trenches / fixed to walls with all fittings such as socket, bends, elbow, union etc., including dismantling the old un serviceable pipe complete all as specified and as directed.
Galvanised iron pipe of 25 mm dia, medium grade, laid in trenches / fixed to walls with all fittings such as socket, bends, elbow, union etc., including dismantling the old un serviceable pipe complete all as specified and as directed.
Galvanised iron pipe of 20 mm dia, medium grade, laid in trenches / fixed to walls with all fittings such as socket, bends, elbow, union etc., including dismantling the old un serviceable pipe complete all as specified and as directed.
Replacement Volt meter range 0 -500 Volts and indication lamps all specified and as directed.
Cast Iron foot valves, 50 mm dia with ISI mark embosed on it, with jointing materials etc, including taking down the existing vlaves complete all as specified and as directed.
Replacement of Electronic timers ST 100 operating range of 160V to 500V all as per L & T Cat No. ST80328OOOO/ST80329OOOO or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Dismantaling the sluice valves of size 100mm bore in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts, gland packing etc., and refixing after carrying out repairs complete all as specified and as directed.
Dismantaling the sluice valves of size 80mm bore in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts, gland packing etc., and refixing after carrying out repairs complete all as specified and as directed.
Sluice valve 100mm dia both side flanged and ISI marked (IS-780) of sluive valve cast iron body with brass spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt, washers and rubber insertion packing 6mm thick including taking down the existing complete as specified and as directed.
Sluice valve 80mm dia both side flanged and ISI marked (IS-780) of sluive valve cast iron body with brass spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt, washers and rubber insertion packing 6mm thick including taking down the existing complete as specified and as directed.
Gun metal gate or globe valves 15 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Gun metal gate or globe valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Gun metal gate or globe valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Gun metal gate or globe valves 40 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Gun metal gate or globe valves 50 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and as directed.
Repacking stuffing box of 80 mm bore sluice valve spindle including taking our apart and reassembling after repairs complete all as specified and as directed.
Sai Ram Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .