Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹3.8 L
EMD Value
₹7,700
Closing Date
20 Aug 2024, 6:00 pmClosed
The Executive Engineer CivilTender KTK CIRCLE
Room No 324 3rd Floor CGMT Doorasamparka Bhavan, No1 Swamy Vivekananda Road Bengaluru 560008
Replacement of unserviceable drainage water supply pipelines of Type IV staff quarters repairs to sanitary channel 4th to 6th floor arresting leakage in DGM QA office at CACT Bldg K R Puram Bengaluru
2024_BSNL_203701_1
40EECBSNLCDBGL202425
Open Tender
Civil Works - Buildings
Item Rate
60 days
KR Puram Bengaluru
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
The Accounts officer Cash BSNL BGTD Bengaluru
₹7,700
24 Aug 2024
3 Aug 2024
23 Aug 2024
8 Aug 2024
20 Aug 2024
8 Aug 2024
8 Aug 2024 - 19 Aug 2024
Amount
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in- Charge.
Internal Work- Exposed on wall
Dismantling PVC pipe with fittings and clamps including stacking the material within 50 metres lead :
75 to 80 mm dia pipe
110 mm dia pipe
Providing and fixing on wall face unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type-B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
100 mm dia pipe
75 to 80 mm dia pipe
Providing and fixing rigid SWR UPVC fittings for PVC pipes of approved quality as directed by Engineer-in-charge.
PVC Plain bend 75mm dia
PVC Plain bend 110mm dia
PVC TEE with door-110X110mm
PVC TEE with door-75x75mm
PVC collar/Coupler -110mm
PVC collar/Coupler -75mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal dia Pipes
25 mm nominal dia Pipes
Providing and fixing CPVC gate/ball valve with handle of approved make (astral/ashirwad or equivalent)
25 mm nominal bore
Supplying & fixing CPVC fittings of following size etc
Union 25mm nominal bore
Making holes upto 250mm dia. in brick walls with breaker/drill machine to expose conceled pipe without damaging, removing debris applying bitumastic primer etc. making good the wall by filling brick bats and 15mm cement plaster 1:4 (1cement:4 fine sand) complete for all lift as directed
P/F 2mm thick GI slotted wall bracket for fixing of PVC pipes in shaft
600x50mm bracket
300x50mm bracket
200x50mm bracket
P/F GI saddle (U-clamp) with nuts and washers of matching size for fixing of PVC pipes over wall brackets
110mmx10mm
80mmx10mm
Making connection of CPVC distribution branch with G.I. main of following sizes by providing and fixing tee, threading the pipe including cutting and fixing with CPVC solvent cement etc. complete :
25 to 40 mm nominal bore
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Chipping of unsound/weak concrete material from slabs, beams, walls etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
a) 25 mm average thickness
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
Bars upto 12 mm diameter
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
25 mm average thickness in 2 layers.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge
With cement mortar 1:4 (1 cement : 4 fine sand
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete
a) 40mm thick with 20 mm nominal size stone aggregate
Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge.
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)
A) Stirrer mixed Acrylic Polymer (SUNPLEX of sunanda chemical or Cebex-100 of FOSROC or equivalent @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work
Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approvedmanufacturer in foundation and plinth in:
a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approved manufacturer in superstructure above plinth level up to floor V level
a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Cleaning monkey dung & garbage inside drainage pipe channel above window chajjas up to floor six level for lift up to 25 metre including washing of base slab with water & brush/broom, plucking out tree seedlings from of base slab/wall areas, spraying approved weed killer diluted with water complete as directed disposal of waste within 50m lead (rate shall be quoted excluding cost of scaffolding to be paid separately)
a) Chajja top area up to 7.00sqm of staff quarters
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
A) In gratings, frames, guard bar, brackets, gates and similar works
Providing and fixing GI welded wire mesh of aperture 50x50mm and 3.0mm dia. in steel frame work of window/ fencing etc. including cutting welding to steel frames and applying a coat of approived steel primer. (Steel work in frames with angle/channel flat etc. shall be paid separately)
Providing and fixing expansion hold fasteners on C.C. /R.C.C. /Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete- Wedge expansion type
Fastener with threaded dia 10 mm
Dismantling M.S. grills in windows by removing screws and refixing after attending repairs & painting of shutters etc. complete as directed.
grill of size up to 1.00sqm area
Cutting MS Rods in window grill for access to sanitary/drainage trench above 4th floor level for inspection/mainenance, grinding of sharp edges of rods with grinder complete.
Providing and fixing ISI marked IS: 1341 oxidised M.S. Pressed Parliamentary hinges with necessary screws etc. complete (Copper oxidised as per IS 1378)
75x100x20x2.24 mm
Providing & fixing polycarbonate monkey spikes above parapet to prevent monkey movement in sanitary trench above fourth floor level including fixing with 38mm SS screws/epoxy adhesive etc. as per manufacturer specifications
UV resistant Polycarbonate spikes-340x110x85mm (Plastkart or equivalent)
Water proofing treatment of RCC sunshade with Zycosil / equivalent water proffing solution [1 Litre Zycosil / equivalent & 20 litres of water stirred first & 2 litres of Zycoprime / equivalent added and stirred (total 23 litres)] till it meats the saturation level and testing as per RIELM or by water drops test in which water drop do not absorb but drop remains or rolls.
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Providing and fixing brass bib cock of approved quality :
a) 15 mm nominal bore each
Providing and fixing brass stop cock of approved quality :
a) 15 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length- 15 mm nominal bore
Removing old water supply fittings like bib cock & stop cock from damaged pipeline & refixing in newly laid water supply pipes
Cutting of banyan/peepal tree growth around pipes/chambers up to sixth floor level and root extractions with following operations (scaffolding and dismantling of pipes shall be paid for separately wherever required as per direction of Engineer-in-charge) a) Cutting branches/stems with hand saw/axe etc. including drilling 10mm dia. holes of 100mm deep in as many branches as possible at site and grouting Systemic Herbicide containing Glyphosate 41% (Glycocin of Maharashtra biofertilizer or roundup of Bayer) with 10ml injection syringe, with all safety precaution such as hand gloves, plastic container for handling the chemical, soap for washing hands immediately after grout opertation under proper supervision b) Uprooting the left over stem/roots embeded in masoary wall/slab adjecent to drainage pipes, after fifteen days with chiesel and pluging gap with cement mortar, disposal of vegetation, debris within 50m lead.
Repairs to old flushing cistern by removing old accessories and providing new accessories kit consisting of PVC syphon, Lever handle with knob, ball valve and rubber ring including adjusting level of ball valve, tightening of coupling of flush pipe attending leakage with M-seal if any disposal of debris complete as directed
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Credit to the agency for dismantled unserviceable material recovered under the relevant agreement items
GI pipes
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .