| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46,063.71Accepted-Finance | ₹46,063.71 | L1 | Accepted-Finance Accept |
| 2 | L2₹48,103.67Accepted-Finance NANDED | NANDED | MAHARASHTRA | 431601 | ₹48,103.67 | L2 | Accepted-Finance Accept |
| 3 | L3₹52,761.23Accepted-Finance | ₹52,761.23 | L3 | Accepted-Finance Accept |
| 4 | L4₹57,682Accepted-Finance | ₹57,682 | L4 | Accepted-Finance Accept |
| 5 | L4₹57,682Accepted-Finance | ₹57,682 | L4 | Accepted-Finance Accept |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
23 Feb 2026, 6:00 pmClosed
Executive Engineer (Project) PHED Div Sardarshahar
Executive Engineer (Project) PHED Div Sardarshahar
Annual Rate contract for work of supply and fixing of various electric spare parts for starter and panel CI specials sluice valve NRVs of various UWSS city Sardarshahar under PHED div Sardarshahar
2026_PHCJA_536777_1
59/2025-26
Open Tender
Public Health Estate Works
90 days
Sardarshahar
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
e-GRAS 4836-X.EN Project Div SARDARSHAHR
₹20,000
Yes
26 Feb 2026
9 Feb 2026
24 Feb 2026
9 Feb 2026
23 Feb 2026
9 Feb 2026
261400 Supply and fixing of oil / Air break DOL / Star Delta Starter made out of sheet steel powder coated enclosure with single phasing protection, ON / OFF push buttons, etc. complete in all respect suitable for following rating motors.261420 Fully Automatic Star/ Delta Starter261424 30.0 HP to 35.0 HP
261400 Supply and fixing of oil / Air break DOL / Star Delta Starter made out of sheet steel powder coated enclosure with single phasing protection, ON / OFF push buttons, etc. complete in all respect suitable for following rating motors. Fully Automatic Star/ Delta Starter261423 20.0 HP to 25.0 HP
100700 P&F 240/415 V porcelain kitkat fuse (/HBC type) conforming to IS:2086,1983 0n existing board/ sheet including making connections with lugs, testing etc. as required100706 100 A ,415 V100706.2 Group - 1
080300 SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.080301 Analog type ( 96 mm x 96 mm )080301.2 Group - 1
080400 SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.080410 Analog type ( 96 mm x 96 mm )080411 Below 500 A080411.2 Group - 1
080800 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.080802 Blue colour080802.2 Group - 1
081400 P & F Cam operated rotary switches on existing panel with 2 way and off position081410 one pole081412 32 A081412.2 Group - 1
081500 P & F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081513 32 Amp.081513.2 Group - 1
081500 P & F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081513 32 Amp.081513.3 Group - 2
081500 P & F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081516 70 Amp081516.2 Group - 1
081700 P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081702 15 to 20 Amp081702.2 Group - 1
081700 P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081703 21 to 30 Amp081703.2 Group - 1
081700 P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081704 31 to 40 Amp081704.2 Group - 1
082000 P&F of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming etc. as required082002 One day & week reserve (mechanical type )082002.2 Group - 1
090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required.090610 With Thermal Magnetic release090611 up to 100 Amp , 10 kA, fixed O/L & S/C setting090611.2 Group - 1
090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required.090610 With Thermal Magnetic release090613 up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu090613.3 Group - 2
090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required.090610 With Thermal Magnetic release090617 250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu090617.2 Group - 1
090700 SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required.090710 With Thermal Magnetic release090711 up to 100 Amp , 25 kA, fixed O/L & S/C setting090711.3 Group - 2
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
Manually Operated CI Sluice valve of Class PN-1.0
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
3 core 4.0 Sq.mm
3 core 6.0 Sq.mm
3 core 10.0 Sq.mm
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
10.0 Sq.mm, 4 core
Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.
Plain ended CI specials including tail piece, spigot end and socket end.
Up to 300 mm dia
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_956628.xls
BOQ • 0.27 MB
TD59.pdf
Tender Documents • 16.99 MB
Download all tender documents and submit your bid