Extension/Augmentation of Health Unit along with CC tile paving Infront, CC road and Compound Wall at Adilabad and CHI Office at Washim - Electrical Arrangements.
NED-E-10-2026-27
NED-E-10-2026-27
Open
12 Months
Adilabad, Telangana
₹0
₹82,000
17 Jun 2026
17 Jun 2026
25 Jun 2026
A-Extension/Augmentation of Health Unit along with CC tile paving
Supply and fixing of 18 W LED round/square type slim light fittings conforming to specification.Make : Bajaj/ Havells /Philips/ Surya
Supply and fixing of 20 W LED Tube Light fittings conforming to specification Make: Havells/Syska /Crompton /Bajaj /Surya.
Supply and fixing of 28 W 1200 mm BLDC Ceiling Fan, BEE 5 star rated with remote control and all connected accessories conforming to class 1 of IS:374/1979 with amdts 1 to 6 including lobor charges. Make:Gorilla /Havells / CG/Bajaj/ Orient.
Supply and fixing of Ventilating Fans (Exhaust fan) of 4 pole 300 mm sweep size with metalic body with capacitor conforming to IS No.2312/67 (Reaffirmed 2005) complete with louver and all connected accessories. Make: Havells/CG/ Bajaj/Khaitan.
Supply and fixing of 40 W LED type weather proof street light fitting complete with all accessories and conforming to specification no. Make: Bajaj/Havells/ Philips.
Supply and fixing of BEE 5 Star rated electric storage water heater (Geyser) of 15Ltrs. Capacity suitable for operation on 230 Volts (+/- 10%), single phase, 50 Hz AC supply with all connected accessories complete. Make:Bajaj/Havells/Crompton
Supply and fixing of Decorative 0.5 W LED Night Lamp in approved manner with lamp holder.
Supply and fixing of 30W 400 mm BLDC Wall Mounting Fan, Energy Efficient with remote control and all connected accessories conforming to class 1 of IS: 555/1979 with Amdts. including labor charges. Make: Gorilla/Havells /CG/Bajaj/Usha.
Supply, installation, testing and comissioning of BEE 5 star rated (ISEER above 4.5) 2.0 ton capacity wall mounting inverter split type air conditioning indoor unit, including inter 9 connecting pipes and cables, Clamps, supporting frame, channels, Angles, nuts bolts etc. complete with all other connected materials and works.(The lengths of the copper pipes shall vary according to the site condition. Installation includes necessary holes to be made on brick/stone walls etc.Contractor is advised to inspect the site before quoting their offer)Makes : Samsung/Blue star/Hitachi/ LLOYD/ LG/Voltas/Carrier /Misthubishi/ Daikin
Supply and fixing of wall /floor mounting type Voltage stablizer of 5 KVA Voltage Stabilizer for AC 2 Ton with all connected accessories and works.
Supply, installation, testing and commissioning of BEE 5 Star Rated 1.5 Ton Inverter type Split Air Conditioning unit conforming to specifications attached and marking S.No. and date of erection. Make: Samsung/Blue star/Hitachi/LLOYD /LG/Voltas/Carrier/ Misthubishi/Daikin
Supply and Fixing extra Copper two pipes for Split AC (if required as per site condition)
Supply and fixing of Drain pipe CPVC of 25 mm dia including accessories, bend, elbows, tees, flanges, tapping's, wall sleeves,hangers supports anchors etc.
Supply and fixing of 4 core x2.5 Sq.mm flexible copper cable (communication cabling) for Split/Cassette AC
Supply, fixing of outdoor suitable outdoor stand for Split AC.
Supply, fixing and connecting of Protected Power Unit for with Built-in 16-25A MCB (as per requirement) conforming to IS:13032 & IS:8623 with suitable sheet steel enclosure and all connected accessories complete. Make:Legrand/Havells /L&T/INDOASIAN.
Wiring points: Provision for wiring with two runs of 4 sq mm 1100 V and one run of flexible copper conductor 1.5 sq mm 1100 V PVC insulated wires (phase, neutral and earth) in 17 concealed PVC conduit pipe/ casing and capping with 6A flush modular type switch control including 2 way switches wherever required, 3 pin ceiling rose and modular type plate cover to MS switch control box including all labor charges complete for fan points, light points, bell points, exhaust fans points etc. All the material used shall be of ISI approved make.
Supplying and erecting unbreakable concealed type modular switch box with double 18 mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the back ground in an approved manner. Make: Legrand/Havells/GM/INDO ASIAN
Supplying and erecting unbreakable concealed type modular switch box with double 19 mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the back ground in an approved manner. Make: Legrand/Havells/ Schneider/GM/ INDOASIAN
Supplying and erecting unbreakable concealed type modular switch box with double 20 mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the back ground in an approved manner. Make: Legrand /Havells/ Schneider/GM/INDOASIAN.
Supply and erection of modular type 5 pin 6A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. Make: Legrand/Havells/GM/INDOASIAN.
Supply and erection modular type switch 6/10A ISI mark approved make duly 22 erectedon provided plate and box with wiring connections complete. Make: Legrand/ Havells /GM
Supply and erection of modular type 3 pin 16A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. Make: Legrand/Havells/GM/INDOASIAN.
Supply and erection of modular type switch 16A ISI mark approved make duly erected on provided plate and box with wiring connections complete. Make: Legrand/Havells/GM/INDOASIAN
Wiring points: Provision for wiring with two runs of 1.5 sq mm 1100 V and one run of flexible copper conductor 1.5 sq mm 1100 V PVC insulated wires (phase, neutral and earth) in the 25 existing concealed PVC conduit pipe/casing and capping with 6A flush modular type switch control including 2 way switches whereever required, 3 pin ceiling rose and modular type plate cover to MS switch control box including all labour charges complete for fan points, light points, bell points, exhaust fans points etc. All the material used shall be of ISI approved make.
Supplying & erecting mains with 2x4 sq.mm. and earth wire 2.5 sq.mm FRLSH PVC copper wire in HMS PVC conduit min. 20 mm dia, as per specification Make: Havells/Finolex /Polycab/Finecab
Supplying & erecting mains with 2x6 sq.mm. and earth wire 4 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min.20 mm dia, as per specification. Make:Havells/Finolex/Polycab/Finecab
Supplying and erecting triple pole and neutral distribution board (TPNDB) with door surface/flush mounted with 4 ways for incoming and 12 ways for outgoing SP/TP MCB's on iron frame/ laminated board as per specification No. SW-SWR/MCBDB Make: Legrand/Havells/L&T.
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 ways for incoming and 10 ways for outgoing SP MCB's on iron frame /laminated board as per specification No. SW-SWR/MCBDB Make: Legrand/Havells/L&T
Supply, erection and marking TPN MCB 63A, 10 kA C-series in provided distribution board as per specification No. SWSWR/ MCB Make: Legrand/ Havells/L&T
Supply, erection and marking DP MCB 16-32A, 10 kA B/C-series in provided distribution board as per specification No. SWSWR/ MCB Make: Legrand /Havells/L&T
Supply, erection and marking SP MCB 16-32A, 10 kA B-series in provided distribution board as per specification No. SWSWR/ MCB Make: Legrand /Havells/L&T
Supply, erection and marking 2P RCCB 32A, 30 mA inprovided distribution board as per specification Make:Legrand/Havells/L&T
Supply, fixing testing and commissioning of 4 Pole MCCB 100 A suitable for operation on 415 V, 50 Hz 3 Phase AC supply in LT Panel with supply of all connected accessories and allied materials as per specification attached. Make:L&T/Legrand /Havells
Supply, fixing testing and commissioning of 4 Pole MCCB 63A suitable for operation on 415 V, 50 Hz 3 Phase AC supply in LT Panel with supply of all connected accessories and allied materials as per specification attached. Make:L&T/Legrand /Havells
Excavation of cable trench 30 cm wide x 90cm deep in all types of soils for HT/LTUG cable as per specification No.Y/E.cable laying/6/99 annexed.
Cutting of esphated road/ concrete/ cement/under the track etc., and excavation of 37 cable trench 30 cm wide x 90cm deep road etc., for laying of HT/LT UG cable. After laying of cable the trench should be brought to its original position by providing tar/ concrete/ cement as per the site conditions and as per directions of Rly.Engineer.
Supply and laying of ISI marked 4 core 25 sq mm cross linked polyethylene (XLPE) insulated LT UG cable, PVC outer sheathed,armored with galvanized round steel wire or steel strip and with Aluminium conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 (Part-1)/1988 with amdt. no. 1,2 & 3 (reaffirmed 2005) or latest. Make: Polycab/ Finecab/Finolex/Havells
Supply and laying of ISI marked 4 core 50 sq mm cross linked polyethylene (XLPE) 39 insulated LT UG cable, PVC outer sheathed, armoured with galvanized round steel wire or steel strip and with aluminium conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098(Part-1)/1988 with am dt. no. 1,2 & 3 (reaffirmed 2005) or latest. Make: Polycab/Finecab/Finolex/Havells
Supply and running of 8 SWG GI wire is to be laid for earth continuity.
Supply and erection of earth electrode as per the enclosed specification.
Supply, erecting and laying of HDPE pipe of PE-80 grade in PN-4 outer dia of HDPE 42 pipe 63 mm (nearest 2"" dia) and wall thickness minimum 2.5 mm maximum 2.8 mm with "T' joints, bends, elbows etc.including all other connected accessories. Make: M/s.Sudhakar/ Nagarjuna polymer/Nandi/Plasto
Providing and fixing sheet metal work in CRCA sheet with fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc.treated with anti-rust treatment and duly power coated as per the above specification.
Supplying and erecting of any size electrolyte copper patti or bar in bus barchamber / 44 in panel or any other purpose, 500 V with require capacity with 99.9 % copper purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete.
Supply, erection and laying of HDPE (High Density Polyethylene pipe) pipe of PE-80 45 Grade in PN- 4 outer dia of HDPE pipe 160 mm (nearest 6" dia) and wall thickness minimum 6.2 mm maximum 7.1 mm with joints, bens, elbows etc. including all other connected accessories.Make: M/s.Sudhakar /Nagarjuna polymer/ Nandi/ Plasto
Supply and erection of 4-way Vertical Load line DB fitted with Busbars, Neutral Links and Blanking Plates suitable for 4 pole MCCB as incomer and 12 ways for MCBs as outgoing with all necessary material and labor complete. Make: L&T/Legrand/ Havells
Supply, fixing, testing and commissioning of Microprocessor Release 160 A ; 4Pole, MCCB suitable for operation on 415 V,50 Hz 3 Phase AC supply in LT Panel with supply of all connected accessories and allied materials as per specification attached.Make: L&T/Legrand/Havells.
Supply and fixing of Water dispenser
Supply ,erecting and laying of 4 core 10 sq mm copper cables XLPE insulated, cores laid up, PVC inner sheathed unarmoured 650/1100 V grade as per IS 7098 (Part 1) 1988.
Supply and laying of 4 core 240 sq mm cross linked polyethylene (XLPE) insulated LT 50 UG cable, PVC outer sheathed, armoured with galvanized round steel wire or steel strip and with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS:7098 (Part- 1)/ 1988 with amdt.no. 1, 2 & 3 (reaffirmed 2005) or latest..Make- Polycab, Finecab, Havells
Supply, erection, testing and commissioning of all material, excavation, and casting of cement concrete foundation/ concreting in ratio 1:3:6 as per site condition and as directed by site engineer.
Supplying and erecting selector switch suitable for volt meter/ ammeter for 3 phase AC supply 500/1000 V, 50Hz, on provided box/ panel and duly connecting with necessary PVC wire leads and lugs.
Supply & provision of 3 Nos RYB indication lamps of LED type including with all connected accessories complete
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting panel mounting type digital ammeter having three and half 55 digit LED display, external CT operated, calibrated for 0 to 1000 A AC supply with necessary PVC wire leads and lugs and mounting hard ware on provided panel complete with calibration certificate from manufacturer (suitable to operate on 500V)
Supplying and erecting panel mounting type digital voltmeter having Three and half 56 digit LED display, calibrated for 0-750 V AC suitable to operate on 500 V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.(suitable to operate on 500V)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022works.pdf
ATTACHMENT
GCCCorrectionSlips1to11_compressed.pdf
ATTACHMENT
Earthing Specification
ATTACHMENT
TechCircular05-2022provisionofearthelectrodesearthing3_compressed.pdf