Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L3₹34.3 L+₹285.60 (<0.01%)Accepted-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L3 | Accepted-AOC Declared l1 bidder amongst bonafide bidders | |
| 2 | L1₹34.4 LRejected-Finance WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Rejected-Finance quoted less than min wages of labour | |
| 3 | L2₹34.4 L+₹107.10 (<0.01%)Rejected-Finance FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L2 | Rejected-Finance quoted less than min wages of labour | |
| 4 | L3₹34.4 L+₹285.60 (<0.01%)Rejected-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-AOC OK | |
| 5 | L3₹34.4 L+₹285.60 (<0.01%)Rejected-AOC | L3 | Rejected-AOC OK |
Tender Value
Refer Docs
EMD Value
₹84,480
Closing Date
11 Mar 2021, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
OUTSOURCING OF SERVICES FOR HT 11KV MRS, DESIDOC, ISSA AND DCA SUB STATION, DG SET INSTALLATION AT SAG AND LASTEC, AC PLANT FOR SSPL ION LAB AND CEPTAM SUB STATION AT METCALFE HOUSE UNDER GE I RND DELHI
2021_MES_414506_1
GE/RND-46/DLI/2020-2021
Open Tender
Civil Works
Works
330 days
DELHI
Class D, Cat - d(v)
2 documents required · 2 mandatory
₹500
GE I RND DELH
₹84,480
Yes
30 Mar 2021
20 Jan 2021
12 Mar 2021
20 Jan 2021
11 Mar 2021
6 Mar 2021
Amount
Outsourcing of services for manning and operation, routine maintenance of the following sub station at M’House area to be operated in the three shift per day (0600hrs to 1400 hrs Ist Shift, 1400hrs to 2200 hrs 2nd Shift, 2200 hrs to 0600 hrs 3rd Shift) from Monday to sunday including holidays by deployment of one skilled electrician cum mechanic in each shift per day complete all as specified and as directed by Engineer-in-Charge:-
(A) MAIN 11 KV HT RECEIVING SUB STATION - This sub station mainly comprises of the following equipments & switchgears :- (i) HT incoming VCB 11 KV 630 Amps, 50 Hz, 3 Phase complete Make Andrew Yule – 01 No. (ii) HT outgoing VCB 11 KV, 3 Phase, 630 Amps complete Make Andrew Yule – 06 Nos and HT outgoing VCB 11 KV, 3 Phase, 400 Amp complete Make Crompton greaves. -01 No. (iii) Transformer step down Capacity 500 KVA, 11 KV/415 V, 3 Phase with HT bushing on one side and bus bar trunking on other side Make – Crompton Greaves – 01 No. (iv) Transformer step down 400 KVA, 11 KV/415 V, 3 Phase with HT bushing on one side and bus bar trunking on other side Make – ECE – 01 No. (v) Transformer step down 300 KVA, 11 KV/415 V, 3 Phase with HT bushing on one side and cable network on the other side Make – ITL – 01 No. (vi) Transformer 1500 KVA, 11 KV/415 V - 01 No. Make :- GEC (vii) Voltage Stabilizer 300 KVA Make- AE - 01 No.
(viii) LT Cubical Panel floor mounting at main receiving HT sub station consisting of the following switchgears:- (a) Incoming ACB Make:- C&S 800 Amps – 03 Nos. (b) Bus coupler(ACB) Make:- C&S 800 Amps - 04 Nos (c) (i) Outgoing MCCB 630 Amps – 09 Nos. Make:- 1 No Havells & 08 Nos CG. (ii) Outgoing MCCB 400 Amps – 01 No. Make:- L&T (d) Outgoing MCCB 300 Amps – 01 No. Make:- CG (e) Outgoing MCCB 225 Amps – 02 Nos. Make:- CG (f) Outgoing MCCB 200 Amps – 01 No. Make:- CG (ix) LT Cubical Panel floor mounting at 1500 KVA transformer consisting of the following switchgears:- (a) Incoming ACB Make:- L&T 2000 Amps – 01 No. (c) MCCB 630 Amps – 03 Nos. Make:- 2 Nos Havells & 01 No Merlin Gerin. (d) MCCB 400 Amps – 03 Nos. Make:- Havells (e) MCCB 300 Amps – 01 No. Make:- Havells (f) MCCB 200 Amps – 01 No. Make:- L&T (g) MCCB 100 Amps – 06 Nos. Make:- CG
(x) LT Cubical Panel floor mounting at 300 KVA voltage stabilizer room consisting of the following switch gears:- (a) Incoming ACB Make:- L&T 1000 Amps – 02 Nos with IDMT relay. (b) Changeover switch - 02 Nos wall mounted installed out side the 300 KVA Voltage stabilizer room. (xi) LT Panel floor mounting near 300 KVA Transformer consisting of the following - 01 No. (a) Incoming ACB 800 Amps – 01 No. (b) MCCB 400 Amps Make:- Havells - 01 No. (c) MCCB 630 Amps Make:- Havells - 01 No. (xii) LT feeder panel installed back side of Main HT sub station consisting of the following switchgears - 03 Nos 1. LT panel:- (a) Incoming MCCB 400 amps - 01 No, Make:- schneider. (b) MCCB 200 Amps – 02 Nos. Make:- Merlin Gerin. (c) MCCB 100 Amps – 04 Nos. Make:- CG 2. LT panel(SAG):- (a) Incoming MCCB 800 amps - 01 No, Make:- Havells. (b) MCCB 400 Amps – 02 Nos. Make:- Havells & SKN. (c) MCCB 800 amps - 01 No, Make:- Standard. 3. LT panel (LASTEC):- (a) Incoming MCCB 630 amps - 01 No, Make:- MERLIN GERIN. (b) MCCB 400 Amps – 01 No. Make:- Merlin Gerin. (c) MCCB 125 Amps – 04 No. Make:- Merlin Gerin.
(xiii) Capacitor Bank (APFC) Panel with all accessories and connected switchgears - 02 Nos, (01 No in 300 KVA voltage stabilizer room and 01 No in Main HT sub station.) (xiv) Earthing complete for VCB, transformer & LT Panels. (B) DESIDOC 11 KV SUB STATION - This sub station comprises of following equipments & switchgears:- (i) HT incoming VCB 11 KV, 3 Phase, 400 Amps complete Make Crompton greaves – 01 No. (ii) HT outgoing VCB 11 KV, 3 Phase, 400 Amps complete Make Crompton greaves – 02 No. (iii) Transformer 500 KVA, 11 KV/415 V – 01 No., Make:- Crompton greaves. (iv) Transformer 400 KVA, 11 KV/415 V – 01 No, Make:- ITL (v) Capacitor Bank Panel with all accessories and connected switch gears - 01 No. (vi) LT Cubical Panel floor mounting consisting of the following - 01 No
(i) ACB 800 Amps with enclosure – 02 Nos, Make:- CG (ii) Outgoing MCCB TP 800 Amps – 01 Nos, Make:- Merlin Gerin. (iii) Outgoing MCCB TP 800 Amps – 01 Nos, Make:- Havells. (iv) Bus coupler 800 Amps - 01 No, Make:- CG. (v) MCCB 300 Amps – 02 Nos, Make:- CG. (vi) MCCB 300 Amps – 01 No, Make:- L&T. (vii) MCCB 225 Amps – 02 Nos, Make:- CG. (viii) MCCB 200 Amps – 11 Nos, Make:-CG (10 Nos), Havells (ix) MCCB 100 Amps – 03 Nos, Make:- CG (02 Nos), Havells (01 No) (f) Isolator Panels with 800 amps ACB, Make:- L&T (g) Earthing complete for transformer, HT Panels & LT Panels. (h) Capacitor Bank Panel 160 KVAR – 02 Nos. (Make:- New Engineer works, SMS)
Outsourcing of services for manning and operation, routine maintenance of ISSA Sub Stn at M’House area two shift (each shift of 08 hrs) (0600 hrs to 1400 hrs) and (1400 hrs to 2200 hrs) Monday to Sunday including all holidays by deployment of one skilled electrician cum mechanic in each shift per day complete all as specified and as directed by Engineer-in-Charge. The installation comprises of the following:- (a) HT incoming VCB 11 KV 400 Amps, 50 Hz, 3 Phase complete - 01 No, Make:- CG (b) HT Outgoing VCB 11KV, 3 Phase, 400 Amps complete - 02 Nos, Make:- CG (c) Voltage stabilizer 630 KVA - 01 No. (d) Transformer 11 KVA/0.415 capacity 630 KVA Make : ITL - 02 Nos. (e) LT cubical panel floor mounting consisting of the following switchgears:- (i) Incoming ACB 1000 Amps 4 pole microprocessor based - 02 Nos. Make:- ABB (ii) Bus Coupler (ACB) 1000 Amps 4 pole microprocessor based - 01 , Make:- ABB. (iii) Change over switch 1000 Amps 4 pole - 01 , Make:- ABB (iv) MCCB TP 1000 Amps- 01 No, Make:- ABB. (v) MCCB TP 800 Amps- 01 No, Make:- ABB. (vi) MCCB TP 630 Amps- 01 No, Make:- ABB. (vii) MCCB TP 400 Amps- 03 Nos, Make:- ABB (viii) MCCB TP 200 Amps- 01 No, Make:- ABB (ix) MCCB TP 100 Amps- 08 Nos, Make:- ABB (f) Earthing complete for transformer, HT, LT, APFC panel and chemical earthing with copper earth electrode -02 Nos. (g) Capacitor bank Panel 200KVAR with all accessories and connected switchgear - 02 Nos.
Outsourcing of services for manning and operation, routine maintenance of DCDA Sub Stn at M’House area two shift (each shift of 08 hrs) (0600 hrs to 1400 hrs) and (1400 hrs to 2200 hrs) Monday to Sunday including all holidays by deployment of one skilled electrician cum mechanic in each shift per day complete all as specified and as directed by Engineer-in-Charge. The installation mainly comprises of the following:- (a) HT incoming VCB 11 KV 400 Amps, 50 Hz, 3 Phase complete – 01 No, Make:- CG (b) HT outgoing VCB 11 KV 400 Amps, 3 Phase,complete – 03 Nos, Make:- CG, HT VCB 11 KV 630 Amps 3 phase complete - 01 No, Make:- Andrew Yule. (c) Transformer 400 KVA – 01 No, (Indoor type) Make:- ABB (d) Transformer 400 KVA – 01 No, (outdoor type) Make:- Rajsthan electrics (e) LT Cubical Panel floor mounting consisting of the following:- (i) ACB 1000 Amps – 02 Nos, Make:-CG. (ii) Bus Coupler (ACB) 1000 Amps – 01 No. Make:- CG (iii) Bus Coupler (ACB) 800 Amps – 01 No, Make:- CG (iv) MCCB 400 Amps – 02 Nos, Make:- CG. (v) MCCB 300 Amps – 02 Nos, Make:- CG. (vi) MCCB 300 Amps – 01 Nos, Make:- L&T. (vii) MCCB 225 Amps – 02 No, Make:- CG. (viii) MCCB 200 Amps – 11 Nos, Make:-CG (10 Nos), Havells (ix) MCCB 100 Amps – 03 Nos, Make:- CG (02 Nos), Havells (01 No) (f) Isolator Panels with 800 amps ACB, Make:- L&T (g) Earthing complete for transformer, HT Panels & LT Panels.
Out sourcing of services for manning and operation, routine Maintenance of standby DG Set 300 KVA (LASTEC) & 200 KVA (SAG) with AMF, LT Panel, earthing and batteries for One Shift each shift of 08 hrs (0830 hrs to 1730 hrs) Monday to Sunday including Sunday & all holidays by deployment of one skilled electrician cum mechanic in each shift per day complete all as specified and directed by Engineer-in-Charge. The installation mainly comprises the following:- (a) For 300 KVA DG Set (i) Prime mover Diesel Engine 300 KVA (ii) Alternator. (iii) AMF Panel with connetced all MCCBs, Change over switches etc. (b) For 200 KVA DG Set (i) Prime mover Diesel Engine 300 KVA (ii) Alternator. (iii) AMF Panel with connetced all MCCBs, Change over switches etc.
Outsourcing of services for manning and operation, routine maintenance of AC plant 3X10 TR at SSPL ION lab Metcalfe House Delhi to maintain inside ambient temperature condition during running period by cooling or heating to be operated in one shift of 08 hours per day 0830 hrs to 1730 hrs and five days a week (from Monday to Friday) by deployment of one skilled operator cum mechanic per shift per day including routine and periodical check ups and attending minor repair for proper functioning of plant, component such as compressor , condensor electric motor , pumpset, AHU,blower motor ,water sunction and discharge pipelines, refrigration piping system along with functioning of interlocking system LP/HP outlet etc, including upkeep of the installation in clean and tidy condition internally and surrounding areas externally by cutting of grass and bushes / wild plants complete all as specified and as directed at site by Engineer-in-Charge.The installation mainly comprises of the following:- (a) Compressor of 10 TR make Voltas -03 Nos. (b) Condensor shell type 10 TR -03 Nos. (c) Pump set monoblock 5HP -02 Nos. (d) AHU with motor cooling coils - 01 No. (e) MS C' class ERW pipe and fitting for refrigrant of size- 01 Set (f) Cooling tower induced type with PVC tank 1000 Ltr - 01 Set (g) Monoblock pump set 7.5 HP -02 Nos. (h) Electric LT panel including:- (i) Main incoming MCCB TPN 250 Amp- 01 No (ii) Outgoing MCCB TP 125 Amp-01 No (iii) Outgoing MCB TP 63 Amp-03 Nos (iv) Bus bar of capacity 400 Amp. (v) Digital ammeter and volt meter for each outgoing and incoming including indicating lamps, CT nd other required accessories.
Outsourcing of services for manning and operation, routine maintenance of CEPTAM Sub Stn at M’House area two shift (each shift of 08 hrs) (0600 hrs to 1400 hrs 1st shift and 1400 hrs to 2200 hrs 2nd shift) Monday to Sunday including all holidays complete all as specified and as directed by Engineer-in-Charge. The installation mainly comprises of the following :- (a) HT incoming VCB 11 KV 400 Amps, 50 Hz, 3 Phase complete – 01 No, Make:- CG. (b) Transformer 11 KVA/0.415 Capacity 500 KVA - 01 No, Make:- CG. (c) LT Cubical Panel floor mounting consisting of the following switchgears :- (i) Incoming ACB 800 Amps – 01 No, L&T. (ii) MCCB 250 Amps 4 pole - 01 No, Make:- Havells. (iii) MCCB 160 Amps – 03 Nos, Make:- Merlin Gerin. (iv) MCCB 100 Amps – 02 Nos, Merlin Gerin. (v) MCCB 200 Amps – 01 No, Make:- Merlin Gerin. (d) Timer switch complete with timer contactor with MCB TPN 16 Amps-01 No. (e) Earthing complete for transformer, HT panels & LT panels and APFC Panel. (f) Capacitor Bank Panel 200 KVAR complete with all accessories and switchgears - 01 No.
Rate required to be quoted for executing the work as described in Ser item No 1.00 to 6.00 above
Workers wage per person as per existing rules.
ESIC (Employees state insurance contribution) as mentioned in tender document.
Bonus as mentioned in tender documents
Overhead & Profit on Ser No 7.01 to 7.03
LWC as mentioned in tender documents.
GST as mentioned in tender documents.
Notes : Rate quoted by the contractor shall deemed to be included the following :- (i) Operator cum mechanic (skilled) shall be of Diploma/ITI passed with having training certificate in relevent trade not less than three year shall be employed for each shift.. (ii) It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/State Govt/Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC , Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable. (iii) In case the rates quoted by tenderer are less than the notified minimum wages as on bid submission end date including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable, his tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongst valid/bonafide bids only. (iv) The firm/contractor shall be solely and fully responsible to his reprsentative/personal for any accident/damage during maintenance/operation/health related liabilities/compensation, penelty etc on this account. (v) T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost.
(vi) Contractor shall be responsible to maintain log books, duty roster attendance register and spare for repair/renewal of parts register, earth register, serviceability register of lifts and as directed by Engr-in-charge. (vii) Shift Operator (reliever) shall neither leave the installations without prior permission of JE/Engineer-in-Charge. Proper handing/taking over to the next operator will be made. (viii) Two pairs of uniform with name plate of operator & firm and shoes shall be provided to each operator by the contractor. (ix) First Aid box will be provided by contractor at each installation. (x) Any increase in minimum wages of labour as fixed by the Govt of India/state Govt/ union Territory, whichever is higher shall be paid to the contractor in accordance with the provision made vide condition 63 of IAFW-2249. Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. no other claim whatsoever shall be addmissible on this account and the bidders shall consider this aspect while quoting their rates. It must be noted that in compliance of the statutory provisions, the increased will be passed over to the workers. (xi) Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt for this shall be maintained by the Engineer-in-Charge & contractor.
(xii) The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates. (xiii) Duty roster for detailement of operators shall be approved by Engr-in-charge within first three days of every month and the same shall be kept on record and properly displayed at each installation. (xiv) The contractor will arrange the earth tester, Megger & clamp meter for installation and will check all the earthings of lifts for its serviceability in presence of JE E/M, Engr-in-Charge and test report shall be submitted to the office of AGE E/M duly signed by the contractor on commencement of work for record. (xv) For any damage to the installations due to negligence of operator such as loose connections, improper routine check up/maintenance etc. the contractor shall be held fully responsible to replace the same damage at his own cost all as directed by Engr-in-charge. (xvi) Original certificates regarding qualifications of operators engaged in the work, police verification and identity proof shall be produced by the contractor to the Engineer-in-Charge for verification and approval.
Taking down carefully point wiring aluminium (light, fan, socket, and power) complete (including fittings such as switches ceiling roses, pendent regulators sockets etc except light fitting and making good the disturbed surfaces complete all as specified and as directed.
M&L for point wring for one light/ceiling fan controlled by one switch with 1.5 sqmm nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLSH in and including concealed PVC conduit 20 mm dia medium duty ISI marked, including suitable new steel sunken boxes, modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLSH connected to common earth duly complete including cutting, chasing the surface and then making good the same in CM 1:6 complete all as specified and directed.
S&F modular switche one way 6 Amps single pole 240 V complete all as specified and as directed.
S&F in replacement of old unserviceable LED light to new 42W LED Recess mounted bakalite panel 2 x 2 luminaire suitable for Ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector complete all as specified and as directed.
S&F in replacement of old unserviceable LED light to new 42W LED Surface mounted bakalite panel 2 x 2 luminaire suitable for Ceiling for low ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector complete all as specified and as directed.
S&F in replacement of old unserviceable fluorescent tube light with LED Tube rod of 20 Watt aluminium heat sink & polycarbonate diffuser having high efficiency suitable for installation in existing T5/T8 tube light including necessary electric connection complete all as specified and directed.
S&F in replacement of old unserviceable LED Bollard light 8 W, BAMBOO type IP-65 including necessary excavation and PCC work 60cm high above ground level and 30 cm below ground level for fixing including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings complete all as specified and directed.
S&F in replacement of old unserviceable LED Garden spike light 12 W, cob integrated Aluminium Green colour light including necessary fixing and fixtures including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings complete all as specified and directed.
Supply only CRC 2-23 Electrical equipment (contact) cleaner spray used for prevent electronic multifunction equipment caused by water penetration, humidity, corrosion etc and of 500ml can.
Supply only Electrical insulation HT tape of 3/4"width of 30 feet length Ethylene Propylene backing highly comfortable to wrap snugly over most any shape stretches up 100 percent to provide avoid moisture, resistant insulation tape complete all as specified and directed. Note:- Proper RV & IV shall be maintained during execution of work.
HIND CONSTRUCTIONS
BRIJ MOHAN LAL AND CO.
M/S VEDHANT ASSOCIATES
V r traders
Pradeep Bros
RUHI ASSOCIATES
jay maa engineers
M/s Wazer Enterprises
M/s Adhikari construction co.
Suman Uni Controllers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .