Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹39.3 L+₹3.6 L (10.1%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹44.2 L+₹8.5 L (23.9%)Rejected-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L3 | Rejected-AOC Rejected | |
| 4 | L4₹44.4 L+₹8.7 L (24.4%)Rejected-AOC 5 A KALPANA NAGAR 7TH CROSSING MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹45.8 L+₹10.1 L (28.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹49.6 L
EMD Value
₹99,280
Closing Date
14 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
REPAIR AND MAINT OF HT OH ELECTRIC SUPPLY, LT SUPPLY AND CONNECTED WORKS AT MORAR CANTT UNDER GE GWALIOR
2022_MES_558071_1
CWE/JHA/GWL/TOKEN/20 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GWALIOR
As per tender documents
9 documents required · 9 mandatory
₹500
GE GWALIOR
₹99,280
Yes
7 Dec 2022
15 Oct 2022
21 Nov 2022
15 Oct 2022
14 Nov 2022
1 Nov 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches n exc. 1.5 m wide and exc 1.5m deep and n.exc 3.0 m deep for foundation beyond the first 1.5 m ,etc. or for shafts, wells cesspits, manholes, pier holes, etc. n exc.10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning in trenches for cable protection including consolidation complete all as specified and directed.
M&L for laying un-reinforced precast concrete cable cover factory made, class HVP, Type 1 of size 300mmx180mmx40mm complete all as specified and directed.
M&L, Steel tublar swaged poles, complete with iron base plate size 75mmx 75mmmx 6mm thick, finials taper plug , bolts, nuts & screws as specified type 410 SP-55 (11.00 mtr long) complete all as specified and directed. Note : Earth work and PCC shall be measured & paid separately under respective items .
M&L for fixing of ACSR conductor on existing or new poles complete all as specified and directed. Note : Stringing of ACSR shall be carried out by winch machine.
M & L for lightening arresters expulsion type 11 KV grade complete with all fittings, transmission class, discharge capacity 65 Kilo Amps complete all as specified and as directed.
M & L for cross arms, bracing, supports, clamps and back plated fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms complete all as specified and as directed.
S&F disc type Insulator (single disc assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut for conductors working pressure 11000 volt grade complete all as specified and directed.
S&F pin type Epoxy Insulator including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 11000 volt grade complete all as specified and directed.
M&L for stay assembly 16 mm dia rod complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed.
M&L for loop type insulator, vitreous porcelain white ,brown or green large size over all dimension 90 X 140mm, clearance of the hole 25.5mm for stay assembly complete all as specified and directed.
BLANK
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminiium conductor, 11000 volts grade cross sectional area 95 sq. mm 3 Core earthed complete all as specified and directed.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminiium conductor, 11000 volts grade cross sectional area 120 sq. mm 3 Core earthed complete all as specified and directed.
Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
Cable joining kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Cable joining kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M & L for switch air break gang operated triple pole out door type with drop out switch fuse unit on HT 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on insulators (12 Nos epoxy insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement complete all as directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed.
M&L for PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M & L for PCC 1:3:6, type C1(using 20 mm graded stone aggregate) as in coping etc. including form work & finishing the surfaces even & smooth without using extra cement complete all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size, for HT of size 25x20cm size complete complete all as specified and as directed.
Supply, laying, jointing and testing, XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of size 3.5 core 150 Sqmm complete all as specified and as directed.
All as per item No 26 but 120 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 26 but 95 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 26 but 50 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 26 but 35 Sqmm 3.5 core complete all as specified and as directed.
M&L for laying un-reinforced precast concrete cable cover factory made, class LV, Type 1, flat size 250mmx150mmx40mm complete all as specified and directed.
Dismantling existing PCC Poles/rail poles, struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc complete all as specified and as directed.
Dismantling ACSR conductor of any size from existing overhead service feeder etc all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and as directed.
Dismantling 11/ KV HT switch gears/GOD/DO Fuse/LA and other accesoories, air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc. or carrying to MES store (spare/ components for replacement to be provided free by department) complete all as specified and as directed.
Restringing and stretching of existing sagged LT/HT ACSR conductor of any size on OH electric line of any length on existing poles after disconnection of binding wires (dismantling & taking down) service connection etc and making, binding and service connection complete all as specified and as directed.
S&F HDPE pipe PE 80 PN 10 of 150mm dia confirming IS-14930 part-I & II through jig machine for conduiting HT cable at the depth of 5 mtr below ground level complete all as specified and as directed.
M&L for vice type connectors consisting of two brass plates, and two steel bolts and nuts for 2 conductors of equal or unequal sizes for non-tension connections including treatment of connector and ACSR conductor with conductor jolly of size 10 to 13 mm complete all as specified and as directed.
M & L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 100 mm dia all as specified and directed.
All as per item No 39 but of size 80 mm dia complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete. Note : Protection pipe & strip beyond 7.5mtrs length will be measured separately.
M&L, earthing complete with galvanised steel earth plate electrode 60cm x 60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with the top edge of the earth plate not less than 1.5 metre below normal ground level connected to galvanised earth wire 4 mm by mean of steel bolts ,nuts,check nuts and washers all as shown in electrical plate No.3 of MES Schedule parts-I 2009 .and including excavation & earth work in any type of soil , disposal of soil , providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit in mix 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 as in cover slab, reinforced with 6 mm dia MS bars 3 Nos. both ways with lift hook made out of 6mm dia bar, watering arrangement with funnel and wire mesh and watering pipe of 20 mm dia GI light grade and 15mm dia light grade pipe for earth lead protection upto 7.50m length (Protection pipe & strip beyond 7.5m length will be measured and paid separately) and testing on completion, complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron steel wire complete all as specified and directed.
M & L for galvanized steel wire 4 mm dia as in cradle guard including dismantling old unserviceable cradle guard complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm galvanised iron steel strip complete all as specified and directed.
Dismantling the existing worn out jumpers of two pole/four pole structure and replacing with new set of jumpers of ACSR Conductor of size 6/1x2.59 from overhead line to AB switch, edge fuse and transformer incl PVC RYB sleeves aluminium thimbles etc complete all as specified and directed.
Supply & Fix HT SFU of 11 kv LBSF panel outdoor complete with, 630-A Load break switch, 200-A D.O.set, Earth switch,Pvc sleeved copper bus- bar for Incoming, Door Interlocking mechanism, Tripping mechanism, Epoxy insulator for bus supports, H. V. cable box provided, For end termination at incoming side, End plate , Provided at outgoing side for end termination etc complete all as specified and directed.
Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm complete all as specified and directed.
Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed.
M&L boring of holes under road, pavement, hard standing by trenches technology using ultra sound technique jig machine through upto 5m below the ground surface to facilitate the all necessary work of Ser item No 37 complete all as specified and directed.
M & L, preparation of old existing surface of steel tubular pole 11mtr long and 9 mtr long including cross arm etc of any description, in any position and applying two coats of high quality aluminium paint around pole and providing the high quality reduim Numbering on pole including making white and black strips on pole with super enamelled paint. complete all as specified and directed.
M & L, preparation of old existing surface of 2x Pole and 4Xpole structure having steel tubular pole 11mtr long including cross arms etc of any description, in any position and applying two coats of high quality aluminium paint around pole and providing the high quality radium Numbering on pole including making white and black strips on pole with super enamelled paint. complete all as specified and directed.
M&L for HT cable route indicator precast factary made from PCC 1:3:6 of size 600mm x 230mm x 100 including excavation PCC for foundation and painting and writing as "11 kv cable" incl preparation of surfaces both sides all as specified and directed.
Taking out HT/ LT un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair and testing by HT/LT meggar, cable fault locator, relaying after repairing complete with joining material and accessories suitable for re-use complete all as specified and directed. Note- (i) Excavation, earth work returning filling, relaying in of good condition cable protection brick/PCC cover up to 100m shall be measured and paid separately. (ii) Jointing Kit will be measured & paid separately. (iii) Sand will be measured & paid separately. (iv) Cost of minor items i.e insulation HT/LT tape insulation sleave for LT may be included in the coated rate.
PRADEEP SISODIYA
anand enterprises
M/S SANTOSH CONSTRUCTION CO
BHARADWAJ BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .