Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.7 L+₹1.2 L (4.58%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹31.4 L+₹5.9 L (22.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹31.5 L+₹5.9 L (23.1%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹32.4 L+₹6.9 L (26.9%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹27.5 L
EMD Value
₹54,940
Closing Date
3 Sept 2024, 6:00 pmClosed
GE (U) UDHAMPUR
GE (U) UDHAMPUR, PO-GARHI, PIN-182121
Spl repairs/replacement of U/S conductor pole and connected electrical eqpt at officer Accn, water supply system at T-morh and provn of water coolers and deep freezers under GE (Utilities) Udhampur
2024_MES_661405_1
GE/U- -2024-25
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (U) UDHAMPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (U) UDHAMPUR
₹54,940
18 Oct 2024
22 Jun 2024
10 Sept 2024
22 Jun 2024
3 Sept 2024
6 Jul 2024
Amount
S&F of Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-55 (11m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed by Engineer-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’.
Dismantling of old / vintage ACSR Conductor site complete all as specified & directed by Engr-in-Charge.
Supply and fix cross arms, bracings, supports , clamps and back plate fabricated from structural steel sections including nuts, bolts , washers , welding, bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and incxlusive of one primer coat , one under coat and one finishing coat of paint complete all as specified & directed by Engr-in-Charge.
M & L for providing earthing with GI earth plate electrode 600 X 600 X3.14mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 20/3 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engr-in-Charge. Note:- All the joints shall be made with welding to get proper conductivity.
Supply , laying and stringing of ACSR Conductor , Aluminium conductor reinforced with steel including various acessories like line connectors , line taps and compression joints wherever required in streaching of conductor, complete all as specified and directed by Engr-in-Charge.
Supply & fix for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 400 sq mm ,3.5 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Supply & fix for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 150 sq mm ,3.5 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Supply & fix for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 50 sq mm ,3.5 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Supply & fix for XLPE insulated, armoured, aluminium conductor cable, 11000 volts grade, heavy duty, cross sectional area 35 sq mm ,3.5 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Supply & fix for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 16 sq mm ,4 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Supply and lay DWC (Double wall corruguated) pipe180x152 mm conforming to IS: 14930/ IS 16205 for protection of HT/LT Cable including necessary snap-fit coupler required for fixing complete all as specified and directed by Engr-in-Charge .
Supply and lay DWC (Double wall corruguated) pipe120x103 mm conforming to IS: 14930/ IS 16205 for protection of HT/LT Cable including necessary snap-fit coupler required for fixing complete all as specified and directed by Engr-in-Charge .
Supply and lay DWC (Double wall corruguated) pipe77x63 mm conforming to IS: 14930/ IS 16205 for protection of HT/LT Cable including necessary snap-fit coupler required for fixing all as specified and directed by Engr-in-Charge .
Supply and lay DWC (Double wall corruguated) pipe50x38 mm conforming to IS: 14930/ IS 16205 for protection of HT/LT Cable including necessary snap-fit coupler required for fixing all as specified and directed by Engr-in-Charge .
Supply and lay DWC (Double wall corruguated) pipe40x32 mm conforming to IS: 14930/ IS 16205 for protection of HT/LT Cable including necessary snap-fit coupler required for fixing all as specified and directed by Engr-in-Charge .
Taking down the old/vintage LT feeder piller box from the circuit system S/F LT feeder piller box of following nomanclature as illustration below:- Type:- CPRI approved / Factory made Panel size:- 3.15mm CRCA Voltage:-415V, 3 Phase, 50Hz BUSBAR:- Copper 600 Amps (Tinned) System:- Outdoor Panel Base:- Angle iron 50x50x6mm Accessories:- Indication lamps (R,Y,B), CTs(Required incommer size), Voltmeter,Ammeter,Cable glands whenever required. Wiring:- Wiring shallbe 2.5sqmm for acc. (copper) Size of Panel:- Size as per switchgear accomdation , double door system ,hindge to be provided,powder coated to complete panel. Note:- PCC foundation according to panel. coping/finising is included in quoted rates.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of GI/CI pipes and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of GI/CI pipes and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Removing excavated meterial not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Returning,filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engr-in-Charge.
M&L for laying tubes medium grade galvanised with all fittings laid in trenches of size 80 mm bore including all fittings such as elbows, Tee, socket, union, reducers, etc complete all as specified and directed by Engr-in-Charge. Note:-(i) Flanges to be provided at every 6 m length or shorter length as directed by Engr-in-Charge. flange will be welded to the pipe and gasket to be provided between two flanges and will be fixed with 08 Nos of nuts and bolts (M20 Type) at each jointing. Flanges will be of IS-6392 specifications. The cost of flanges,nuts & bolts, gaskets and connecting of flanges to pipeline by welding will be deemed to be included in the quoted item rate.
(ii) All standard fittings such as bends (any type, radius or angle), tapers any type (straingt, bend, increasing, decreasing or double socket etc) TEE pieces single branch, 'Y' Junction, double branch, cross collars, cap and plugs, MS flanges complete bends, TEE pieces, collars, elbow, tail piece etc jointing are deemed to be included in the quoted item rate. Make of fitting - ISI marked. (iii) Jointing of pipe line will be done through flanging only and as directed by Engr-in-Charge. (iv) Excavation and earthwork will be measured and paid separately. (v) Any special fittings to be fabricated at site as per typical site condition will be measured and paid seprately. (vi) Welding of flanges to be done by trained personnels at site and included in the quoted rate for normal flange joints for nominal length of pipes. However if the welding of pipes (other than normal flanged joint at normal length) is required the same shall be measured and paid separately.
M & L for laying tubes medium grade galvanised with all fittings laid in trenches of size 50 mm bore including all fittings such as elbows, Tee, socket, union, reducers etc complete all as specified and directed by Engr-in-Charge.
All as per serial item No 22.00 here-in-before but of size 20 mm bore including all fittings such as elbows, Tee, scocket, union, reducers etc complete all as specified and directed by Engr-in-Charge.
Supply fabrication and fixing MS joints like bends Tee, tapers, collars, elbow, tail piece (any type) caps, plugs up to 150 mm bore complete all as specified and directed by Engr-in-Charge.
Supply and fixing cast iron sluice valve of size 80 mm dia (PN 1.6) ISI Marked with iron wheel head both end flanged, CI /steel spindle, non rising type complete with neoprene rubber gasket, nuts, bolts and washers including taking down the old one etc coplete all as specified and directed by Engr-in-Charge.
Cutting of existing GI/CI water main pipe line upto 250 mm bore in position for making branch connection (insertion of GI Tee) including excavation and earth work complete all as specified and directed by Engr-in-Charge. Note:GI fittings such as tee, elbows, collar, reducer etc joint and jointing material for fixing of cast iron fittings shall be measured and paid separately.
Supply and fixing gun metal gate valve of size 50 mm dia bore ISI marked cast copper alloy, with iron wheel head screwed both ends for iron pipe or for union and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fixing gun metal gate valve of size 20 mm dia bore, ISI makred cast copper alloy screwed down high pressure with clutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed by Engr-in-Charge.
M&L for cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary exacavation and earth work including repairing the same as per existing with pre mix bituminous carpet complete all as specified and directed by Engr-in-Charge.
Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, buil in 1:3 in CM complete all as specified and diected by Engr-in-Charge.
M&L cement concrete in foundation, filling and mass concrete type C2 1:3:6 (40mm graded aggregate) for base 100mm thick concrete for bk pillar and providing thrust block complete all as specified and directed by Engr-in-Charge.
M&L rendering 10mm thick on fair faces of bricks works or concrete surfaces in cement plaster and add or deduct to/from the rates for rendering for each 5mm thickness over or under 10 mm (CP 1:3) complete all as specified and directed by Engr-in-Charge.
Construction of brick masonry valve pit chamber all as specified and including excavation and earth work in any type of soil plastring PCC in foundation MS sheet cover 3mm thick with locking arrangement 65mm dia : Godrej (Freedom) painting with two coats of bituminous paint etc complete of size 1000 x 900 x 600 mm complete all as specified and directed by Engr-in-Charge.
M&L for supplying installing, testing of Electronic Liquid Chlorine (SODIUM HYPOCHLORITE) dozing pump 230V AC 50 HZ capacity upto 10LPH @ 5 Kg/CM2 pressure, pump head PP with glass filled, Teflon Diaphragm with suction and discharge tubing 3 meters alongwith PVC injector with NRV with 150 Ltr capacity heavy duty FRV tank complete, with 15mm dia GI Pipe medium grade with control valve for inlet connection of dosing tank with necessary electric connection to dosing pump complete all as specified and directed by Engr-in-Charge.
M&L for cast iron air release valve with two air outlets of size 80 mm dia including all jointing materials like high pressure rubber gasket nuts, bolts, etc complete all as specified and directed by Engr-in-Charge.
Taking up or down GI water mains pipe 80/50 mm bore (including all fittings), complete all as specified and directed by Engr-in-Charge.
Supply and fix Deep freezer hard top 320 litre capacity having double door, BEE star rating, warranty as per OEM on product complete all as specified and directed by Engr-in-Charge.
Supply and fix normal and cold water cooler electric driven (single phase), stainless steel body, having approx storage capacity of 80 litre and nominal cooling capacity of 40 litres per hours and inlet water connection complete with PCC foundation as per site requirement complete all as specified and directed by Engr-in-Charge.
Supply and fix 4 KVA digital voltage stabilizer copper wound for automatic operation single phase naturally air cooled indoor type and disigned for input voltage 130V to 280V with output voltage 230V with accuracy of + 2.5% and capacity 4 KVA complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with two single core 2.5 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor (FRLS) ISI marked drawn into & including medium grade surface conduit/casing caping, 25mm dia with all fittings and accessories and one continuous run of 2.5 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into surface conduit/casing capping (not less than 25mm outer dia) with all fittings and accessories fixed conealed/surface complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination 5 in 1, 5 and 15 Amp flush type universal controlled by one switch (ISI marked) complete all as specified and directed by Engr-in-Charge.
S&F steel water tubing medium grade galvansied with all fitting and fixed complete to wall and ceiling or laid in floor of 20 MM bore complete all as specified and directed by Engr-in-Charge.
Supply and fixing water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in-Charge.
S&F Gun-metal, Gate valves 20 mm bore, ISI marked with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F in replacement ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of 20 mm bore including fixing of socket, if required complete all as specified and directed by Engr-in-Charge.
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3058200)
PREM NATH KHAJURIA AND SONS (BID ID -3074255)
FANGALIA TRADERS (BID ID -3069672)
MOHAN LAL AND SONS (BID ID -3068343)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .