Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.0 L+₹13.6 L (43.5%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹46.5 L+₹15.2 L (48.4%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹48.5 L+₹17.1 L (54.5%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
31 May 2024, 6:00 pmClosed
GE NAMS
GE NAMS AMRITSAR
DAY TO DAY COMPLAINTS OF INTERNAL ELECT SUPPLY, ELECTRIC METER, SOLAR WATER HEATING SYSTEM, LIGHTENING CONDUCTOR AND ALLIED WORKS AT NAMS
2024_MES_652216_1
GE NAMS-15/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE NAMS
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹98,000
16 Jul 2024
3 May 2024
7 Jun 2024
3 May 2024
31 May 2024
17 May 2024
Amount
Attending of day to day electrical complaints pertaining to internal electrification received through telephone/ Armaan or in person on detailment at MES Service centre located at NAMS Area by locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not increasing 0.50 mtrs and fixtures for power and light socket/light, fan and bell etc complete and carrying out repairs to the extent of tightening of loose connections, disconnection and dismantling of faulty wires, battens, conduits, boxes, main switches, MCB's, DB's and other E/M fixtures including providing necessary screws / nuts / bolts / nails for the rectification of defect and refixing of existing dismantled serviceable items and replacement of defective items with new ones complete all as specified and directed. Note - (i) Cost of labour for the fixing/replacement of unserviceable item shall deemed to be included in item no 2 and cost of store replaced shall be measured as supply only against relevant Items.
(ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub main wiring/DB's/fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement of two fixtures in one Qtr will also be measured and paid as one complaint. (iii) Replacement of more than two fixtures/items but multiple of three fixtures or part thereof in one Qtr/Bldg will be measured as an additional complaint. (iv) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as one till its completion. (v) Necessary tools for tradesman shall be provided by the contractor. (vi) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor. (vii) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent nature i.e no light, short circuit, earth fault etc shall be attended immediately on receipt of complaint round the clock. (viii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below
(ix) Requiring stores i.e switchs and sockets, fan regulator, bell push, metal flush box, lamp holder, bell ding dong of modular and non modular shall be issued by department for fixing only. (x) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit. (xi) Electrician will report to AGE EM complaint cell at 9 O'Clock daily for collecting of complaints. Complaint received on Armaan application will be done in the same day and after completion of complaint Electrician will report to Armaan Cell for uploading the completion report. (xii) Contractor deploy local electrician for the job so that urgent nature of complaint like no light, short circuit and earth fault will also done on Holidays/ Sunday. (xiii) The contractor will deploy 4 nos electrician and 2 nos geyser mechanic throughout the contract irrespective of no of complaint received. (xiv) For Non attending of urgent nature complaint within 24 hours a penalty of 100 RS/per day/per complaint will be levied on contractor.
Supply only in replacement switch piano flush type 5 Amps One-way, AC 230V on existing switch board all as specified and as directed.
Supply only in replacement of switch piano flush type 15 Amps single pole one-way, 230V complete all as specified and as directed.
Supply only in replacement switch piano type two ways AC 230 volts 6 Amps as per on existing switch board .
Supply only in replacement socket out let 2-in-1, 3 Pin 6 Amps flush type 230 volts complete all as specified and as directed.
Supply only in replacement socket outlet, flush type, 2-in-1, 3 pins, 6 & 16 Amps multipurpose complete all as specified and as directed.
Supply only in replacement bell push switch piano, flush type, 5 Amps complete all as specified and as directed.
Supply only in replacement of bell ding-dong 230 volts, single phase complete all as specified and as directed.
Supply only in replacement of ceiling rose 65x50mm two to three terminals AC 230 volts complete all as specified and directed of any make/model as per in existing building.
Supply only in replacement batten type angular/ Batten lamp holder insulated body with back plate suitable for batten fitting including PVC round block complete all as specifed and as directed.
S&F in replacement MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards all as specified.
S&F in replacement MCBs single pole and neutral (SPN) 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards all as specified and directed.
S&F in replacement MCBs single pole and neutral (SPN) 40 to 63 Amps with 10 KA breaking capacity of 'B' series in distribution boards all as specified and directed.
Supply only in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed.
Supply only in replacement plug top 3 pin, 5 Amps complete all as specified and as directed.
Supply only in replacement plug top 3 pin, 15 Amps complete all as specified and as directed.
Supply only in replacement LED Tube rod with polycarbonate diffuser 4 feet long of capacity 18 watts complete with all accessories base all as specified & directed by Engr-in-Charge.
Supply only in replacement LED Tube rod with polycarbonate diffuser 4 feet long of capacity 20 watts complete with all accessories base all as specified & directed by Engr-in-Charge.
Supply only in replacement LED Tube rod LED tube rod with polycarbonate diffuser 4 feet long of capacity 20/22 watts complete with all accessories base all as specified & directed by Engr-in-Charge.
Supply only in replacement of LED 12 Watt Square shape surface mounted LED Panel down lighter of size as per site requirement complete all as specified and directed,
Supply only in replacement LED bulk head light fittings including led lamp 10 watt as per IP65 and making necessary connections complete all as specified
Supply only in replacement LED slim panel cygnus series recess/surface/suspended mounting LED slim ceiling light 2'x2' with extruded aluminium housing and milky diffuser, suitable for recess mounted size 595x595mm complete with LED tube.
Supply only in replacement of 6 Watt Round/square recess mounted down lighter separate replaceable electronic driver celling cut out dia as per existing shaped polycarbonate fixture complete all as specified and directed,
Supply only in replacement of 12 Watt Round recess mounted down lighter separate replaceable electronic driver celling cut out dia as per existing size round shaped polycarbonate fixture complete all as specified and directed,
Supply only in replacement of 15 Watt Square/round recess mounted down lighter separate replaceable electronic driver celling cut out as per existing square shaped polycarbonate fixture complete all as specified and directed,
Supply only in replacement of 18 watt Square recess mounted down lighter separate replaceable electronic driver celling cut out dia as per exising size/round or square shaped polycarbonate fixture complete all as specified and directed,
Supply only in replacemnt box type PVC rectangular block for mounting switches, sockets, fan regulator etc 4 / 6 way, surface mounting including necessary gitti for fixing complete all as specified and as directed.
Supply only in replacement of frame plate with cover for modular switch 3/4 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
Supply only in replacement of frame plate with cover for modular switch 6/8 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
Supply only in replacement ceiling fan regulator, electronic Socket type, single phase, 230 volts complete all as specified and as directed.
Supply only in replacement ceiling fan regulator, electronic switch type, single phase, 230 volts complete all as specified and as directed.
Supply only in replacement MS machine screw 25 mm long suitable for fixing bakelite hylam sheets / square blocks complete all as specified and directed .
Supply only in replacement MS Housing box 5 / 6 module suitable for modular switch as per existing including taking out old UNSV switch box and making good to the disturb surface by pcc complete all as specified and as directed.
Supply only in replacement of MCCB 100 amps 4 pole, AC 415 volts 16 KA, four pole including making connections with suitable size of aluminium lugs of any make /Model as per Existing MCCB Fitted in DB. all as specified.
Supply only in replacement of modular switch 6 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
Supply only in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
Supply only in replacement of modular socket, 5/6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed.
Supply only in replacement of modular socket, 15/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed .
Supply only in replacement of capacitor AC 230 volts 2.25 MFD
Supply only in replacement of capacitor AC 230 volts 3.15 MFD
Supply only in replacement of 3 mm thick hylam sheet of any size including screws and washers etc as per required at site complete all as specified and as directed.
Supply only in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and as directed.
Supply only in replacement of 12 Watt round recess mounted down lighter separate replaceable electronic driver celling cut out dia as per existing , polycarbonate fixture complete all as specified and directed.
S & F in replacement LED tube light fitting. ,1 x 18/20 W, 230 V Energy efficient T8, Box type made of CRCA shee heavy duty industrial type housing with reflector cover channel, bipin holders, connector block, etc. complete with tube rod LED 18/20 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
S & F ( in repacement) PVC round fan cover plate of size 6" to 8" or as per exiting size complete all as specified and directed.
S & F ( in repacement) casing caping of existing size as per site including laying of electric wire inside, making electric connection and fixing necessary saddle and gitti at regular interval complete all as specified and directed.
S & F in LED mirror fitting. 1 x 8/9 W, 230 V Energy efficient , Batten type, polycarbonate housing with reflector cover channel, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply only in replacement of single core wire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
Supply only in replacement of single core wire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm multi strand pvc insulated copper conductor cable in existing concealed conduit for one light or bell point controlled by one switch including pvc insulated 1.5 sqmm copper conductor continuous earth wire using existing CI/MS sunken box and connecting earth with dolly complete all as specified and directed. ( Note : Switch, socket measured as separate item )
Description all as per item No 50.00 here in before but for one 5 Amps independent board complete
Description all as per item No 50.00 here in before but for one 5 amps socket out but on the same board complete
Matrial and labour for point wiring with 2.5 sqmm multi strand pvc insulated copper conductor cable in existing concealed conduit for one 15 amps socket outlet independent controlled by one switch including pvc insulated 2.5 sqmm copper conductor continuous earth wire connecting earth with dolly complete all as specified and directed.
Supply & fix in replacement of building security LED Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240,50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specified.
Supply and fix in repair GI pipe bracket ,made out of GI pipe 50mm dia light grade 1.2mtr long bend to the shape 120 degrees angle complete with two nos of clamps for fixing on walls complete all as specified and directed.
Supply & fixing in replacement of integral post top lantern 25/35 watt complete with black ABC plastic spigot, spun aluminium funnel shape with clear acrylic cover light opening on canopy with baffles and accessories and suitable for LED lamp complete all as specified and directed
M& labour in replacelment for service wire10 sqmm 2 core pvc insulated and pvc sheathested 1100 volts grade all as specified and directed
M&L for taking down the existing faulty single phase tamper proof Electronic Energy meter with LCD display 230 volts 4 wire system, 10-60 amps, 50 Hz ,replacing the unserviceable chip board, unsv body and all burnt parts complete,making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-Charge.
M&L for taking down the existing faulty 3 phase tamper proof Electronic Energy meter with LCD display 415 volts 4 wire system, 10-60 amps, 50 Hz ,replacing the unserviceable chip board, unsv body and all burnt parts complete,making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-Charge.
Attending complaints for taking down geysers of any make & size from existing position of any height for repair, mainteance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
S & F in replacement PVC connection pipe (hot type) 15 mm bore size with PTMT nuts, rubber washers etc complete of length 450 mm long complete all as specified.
S & F in replacement PVC connection pipe (hot type) 15 mm bore size with PTMT nuts,rubber washers etc complete of length 600 mm long complete all as specified.
S & F in replacement geyser element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
S & F in replacement geyser element 1.5 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
S&F in replacement thermostat (ISI marked) suitable for existing make of the geyser under repair of cap 50 / 25 Ltrs complete all as specified.
S&F in replacement geyser safety valve (pressure release valve) for the exsiting make & capacity of geyser complete all as specified.
S&F in replacement shyphon assembly suitable for 50 ltr geysers of any make, any type complete all as specified and as directed by Engr -in-Charge.
S&F in replacement shyphon assembly suitable for 25 ltr geysers of any make, any type complete all as specified and as directed by Engr -in-Charge.
S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 25 /35 ltr geyser vertical type including rubber gasket complete all as specified and directed.
S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 50 ltr geyser vertical type including rubber gasket complete all as specified and directed.
S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 50 ltr geyser complete all as specified and directed.
S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 25 ltr geyser complete all as specified and directed.
S&F in replacement 3 Core PVC insulated PVC sheathed flexible copper wire multistranded of size 2.5 sqmm complete all as specified and directed.
Supply & fix in replacement indicator lamp any type/size 230 Volts complete all as specified and as directed.
Supply & fix in replacement of brass non-return valve 15 mm dia horizontal/verticle type ISI marked complete all as specified and as directed.
Supply and fixing in replacement of metal clad plug top 20 Amps complete,all as specified and directed.
Supply and fixing in replacement of metal clad socket 20 Amps complete,all as specified and directed.
Disconnecting electrical connection of solar heating device carefully dismantling solar panel with water tube (copper assembly/ETC tube) rubber gasket; nut bolt; biding aluminum channel and glass carefully and servicing/Descaling/cleanning with acid & water circulation and wire brush and brazing of cooper tube checking of leakage if any . After servicing reassemble the same making electric and water connection and testing of solar water heater complete all as specified.
Supply and fix in replacement of heating elements for solar water heating system 5 KW with rubber gasket for any type of solar water heater as per exisiting complete all as specified and directed.
Supply and fixing in replacement of 500 ltrs pre insulated hot water storage tank with stand (inner tank SS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /argon welding and reclading,connecting the removed water lines,testing of solar hot water tank all as specified and as directed.
Supply and fix in replacement of Syntex tank cap 1000 ltrs of Solar complete all as specified and directed.
Supply and fix in replacement of Syntex tank cap 500 ltrs of Solar complete all as specified and directed.
Supply and fix in replacement of GI Pipe medium grade with insulation dia 20 mm complete all as specified and directed.
Supply and fix in replacement of GI Pipe medium grade dia 15 mm complete all as specified and directed.
Supply and fix in replacement thermostat for Solar water heater, AC, SP 220 volts including making necessary connection, ISI marked, complete all as specified and as directed.
Supply and fix in replacement of temparature gauge for water heating system ISI marked, complete all as specified and as directed.
Material and labour in replacement of solar glass panel complete all as specified and directed including collant quiet, absorbing plates , flow tube , insulation coolant outlet certificate for transmissibly will be provided from approved company complete all a specified and directed.
Supply and fixing in replacement of automatic monoblock pressure/booster pump size 25 mm x25 mm, tech motor S1 class B 230 Volts 500 Hz, RPM 2800, 10 MF, Input power 650 watt with pressure tank of cap 19 Ltrs PS max pressure bar 10 PT test pressure bar 14 with complete accessories incl GI pipe/gate valve/NRV complete all as specified and directed.
M&L for replacement of geyser assembly including heating element , relay , thermostat etc complete suitable for 25 ltr cap geysers as per existing make Complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of Air termination single pointed aluminium rod 12mm dia and 300mm long including taking out the existing one complete all as specified and directed
Description all as per item No 90.00 here in before but Fixing only of Air Termination rod 12mm dia and 300mm long complete etc retrieved for reuse complete or all as directed and Specified.
Supply and fixing in replacement of test terminal block made of gun metal or phosporus bronze size 75x75x25 mm drilled and screwed including 03 Nos, 8mm dia 25 mm long hex, head scew including taking out existing unsv test terminal blocks complete all as specified and direted.
Description all as per item No 92.00 here in above but Fixing only test terminal block made of gun metal of any size complete etc retrieved for reuse complete or all as directed and Specified by Engr-in-Charge.
Supply and fixing in replacement aluminum strip 25x3.15mm with saddles and fixing screws with rubber washers for protection of water leakage etc for roof conductors and down conductors above ground including fixing clamps/insulator and taking out existing aluminium strip complete all as specified and directed.
Supply and fixing in replacement GI strip 32x6 mm with saddles and fixing screws with rubber washers for protection of water leakage etc for roof conductors and down conductors above ground including fixing clamps/insulator and taking out existing aluminium strip complete all as specified and directed.
Description all as per item No 95.00 here in above but Refixing only GI strip including re aligning of strip and refixing of PVC/Porcelain insulators with 6cm long screws etc for roof conductors and down conductors retrieved ground complete all as speciifed and directed.
S&F in replacement for GI tubing, 40mm bore, light grade with fittings like MS clamps, Nut & Bolts for fixing to wall or laid in floors complete all as specified and directed.
M&L for PCC 1:2:4, type B1 (using 20mm stone aggregate) for install to air termination rod and fair finish to the exposed surfaces complete all specifed and direccted.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized iron strip of size 25X4 mm by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PART 1 , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified & testing on completion.
Santokh Singh and Associates
CHINAR ENGINEERS AND BUULDERS
UNITED ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .