Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.0 L+₹2.7 L (7.12%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹41.3 L+₹3.9 L (10.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹44.2 L+₹6.9 L (18.4%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L4 | Rejected-AOC L4 | |
| 5 | L5₹44.4 L+₹7.1 L (19.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹45.9 L
EMD Value
₹91,760
Closing Date
15 Dec 2022, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
SPECIAL REPAIRS TO BUILDING NO. P-152 AT AFS BEGUMPET AND PROVN OF ROOF TREATMENT IN CERTAIN OMQS AND SMQS AND ADDN/ALTN TO GATE NEAR SUB GUARD ROOM AT AFS BEGUMPET UNDER GE (AF) HAKIMPET
2022_MES_565925_1
8451/E8
Open Tender
Civil Works
Item Rate
180 days
BEGUMPET
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Hakimpet
₹91,760
Yes
27 Dec 2022
29 Nov 2022
17 Dec 2022
29 Nov 2022
15 Dec 2022
30 Nov 2022
Amount
Taking down chowkats or frames n exc 1.5 sqm each with shutters (without taking off shutter from the frames)
Demolition of PCC cement concrete in groung floor and paving n.exc 15 cm thickness below or above ground level and removed debris outside the MD land..
Demolition of PCC cement concrete of any description and in any position not otherwise specifically provided for (in 1st floor of toilet) and removed debris outside the MD land.
Demolition of brick or stone masonry bilt in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stone work and precast concrete articles all as directed.
M&L Cement concrete 1:4:8 type D2 in 75mm thick base concrete under floor.
M&L for PCC 1:5:10 type E2 as in mass concrete such as in sunken floor.
M&L for 15mm thick plastering in CM 1:4 for masonry/concrete surfaces using 3% of water proofing compound by weight of cement (but excluding the cost of water proofing compound) as in sunken floor surfaces including finishing the surface even and smooth without using extra cement
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) a in floor using 3% of water proofing compound by weight of cement (but excluding the cost of water proofing compound) including finishing the surface even and smooth without using extra cement
M&L for Bitumen blown any grade, applied hot, two coats to concrete or plastered surfaces at the rate of 1.5kg per Sqm per coat all as specified and as directed.
Taking down cement plaster from stone/brick walls/concrete surfaces including raking out joints for keys and scrubbing down with water etc., and removed debirs outside MD land complete all as specified and directed .
M&L rendering 10 mm thick on fair face of brick work or concrete surfaces finished even & smooth without using extra cement in CM 1:6, complete all as specified and directed internal walls.
M &L rendering fair faces of brick work (or) concrete surfaces 5mm thick in CM 1:4 with WPC over 10mm thick in CM 1:6 finished even and smooth without using extra cement exteranal walls .
M&L for brick work with subclass 'B' bricks straight or curved on plan to any radius half brick thick wall built in CM 1:4
M&L for brick work with subclass 'B' bricks straight or curved on plan n.exc 6 mtr mean radius built and setting in CM 1:6 complete all as specified
M&L washing,rubbing down and stopping of distempered and painted surfaces on wall and applying two coats of Distemper oil emulsion on over a coat of primer on walls all as specified and as directed.
M&L for applying Altec or equivalent putty as approved by GE on wall to obtain even and smooth finished all as specified and as directed.
M&L washing,rubbing down and stopping of distempered and painted surfaces on ceiling and applying two coats of Distemper oil emulsion on ceiling over a coat of primer all as specified and as directed.
M&L preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali-resistant priming paint as directed.
M&L preparation of old plastered surfaces of walls and applying two coats of cement based paint as directed.
Dismantling floor/wall tiling including cement mortar ( but not backing) removing of unserveable tiles from site and rubbish of the premises.(vertical surface)
M&L for Cement concrete type B-1,1:2:4(20mm graded aggregate) 25mm thick in floor
M&L for screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes.
M&L for rendering 10mm thick in CM 1:4 to wall as a backing coat to dados.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces and finished surfaces even and smooth without using extra cement all as specified and as directed.
S&F non skid ceramic coloured antiskid tiles 300x300x7mm thick in floors etc.Set and jointed in neat cement slurry and pointed in white or coloured cement to match
M & L coloured Glazed ceramic tiles in vertical surface 350 x 450 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match
S&F vitrified Double charged tiles 10mm thick (square/rectangular) polished area of each tiles not exceeding 0.36sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Labour only for rounding to edges of stone slabs one edge, like in steps, cooking platform, and other similar situations
Precast RCC 1:2:4 type B1 using 20mm graded stone agg in cover slabs set in cement mortar 1:6 including all necessary form work (Note : Reinforcement shall be measured and paid separately).
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel bars TMT 6mm to 8mm dia and over, cut to length bend to shape required incl cranking bending and binding with mild steel wire (annealed) not less than 0.9 mm dia.
S & F in repairs, vitreous china wash basin, white, flat back, size 550x400mm with brackets, inc. cutting for & pinning in ends of brackets, including. waste fitting, PTMT 32mm dia and CPVC down take pipes complete all as specified and directed.
Supply and fixed in repairs CP Wall mixture 3-IN-1 system with provision of for both hand and shower complete with 115 mm long bend pipe on upper side connecting legs & flanges ( without hand and head shower) Mk : Jagar Code No CQT-CHR- 23281UPR or Equivalent
S&F in repairs CP central hole basin mixture with popup waste system with 450mm braded hoses Make Jaquar, CAT No.CON-CHR-169KNB or Equivalent
S/F in repairs CP Angular stop cock 15mm Mk: Jaguar Cat No :CQT-CHR-23053 or Equivalent
S&F in repairs SS toilet paper holder with flap make JAGUOR code no.AKP 35735 or Equivalent
S/F in repairs CP two way bib cock. (Mk Jaguar Cat No DRC- CHR 37041) or Equivalent
S/F in repairs Stainless steel towel rail 600mm long Mk: Jaguar Cat No 7711 or Equivalent
S/F in repairs Soap dish holder Mk : Jaguar cat No 35731 or Equivalent
S&F in repairs of Vitreous China Urinal, Half stall type, White (back or corner wall type) Best quality including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, waste pipe pointing around urinal back in cement etc complete all as specified and directed
S&F in repairs of make Jaquar urinal spreader-13262 or Equivalent complete including providing and fixing plugs, complete all as specified and as directed.
S/F in repairs looking mirror of any size rectagular fancy type 2.0 x 0.60 having bevelled boarders of glass fixed to walls with stud pins.Make Gumaxy or Equivalentcomplete all as specified by engineer in charge.
S&F cornner glass shelf of size 9"x 9" shelf and frond,circle in design fixed over chromium plated brackets of heavy duty with frond linings with glass fixed in wall with necessary screws make Jaquor ACR 1173 or Equivalent
S&F in repairs single flow over head shower chromium plated fancy type bottom with rubber holes all as specified and directed fixed in repairs Make-Jaquor code 1989 & SHA 477
S/F in repairs health faucet with fluxi pipe and hand shower ,the length of hose 1mt fitted to the tap.make JAGUOR Code ALD CHT 565 or Equivalent
S&F in repairs vitreous EWC WITH PP SOFT CLOSE SEAT COVER, HINGES, FIXING ACCESSORIES SET SIZE 365X560X400MM, P TRAPcomplete all as specified and as directed. MAKE Jaquar CNS-WHT-551PSPP CONTINENTAL SERIES or Equivalent
S & F 32mm Dia PVC waste pipe with fly nut, coupling for sinks/urinals or wash basins etc.
PVC (SWR) floor trap plain with grating incl jointing with solvent cement. Dia of outlet 75mm.
S/F PVC(SWR)75mm bore pipes single socketed in any length with rubber ring joints fixed to walls/floor
All as per Item here-in above but 110mm bore
PVC (SWR)bend 110mm bore
PVC (SWR)bend 75mm bore
PVC(SWR) bend 110mm bore with access door
All as per item here-in-above but 75mm bore
S/F PVC(SWR) vent cowel 75mm bore
All as per item here-in-above but 110mm bore
S&F 10ltr capacity PVC flushing cistern low level white with brackts and connections to pipes fixed in repairs.
S&F PVC conniction 15mm size with PTMT nuts of length 450mm etc complete
S&F medium grade galvanised iron 15mm bore with all fitting and fixed complete to walls and ceiling or laid in floors including taking down old unserviceable pipes.
S&F medium grade galvanised iron 20mm bore with all fitting and fixed complete to walls and ceiling or laid in floors including taking down old unserviceable pipes.
Supply only integral water proofing compound.
S & F Solid PVC Door Frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube,supplying and fixing in opening as per manufacturers instructions and as directed by Engineer-in-Charge.
S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails .M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail ,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement and fixing in the frame as per manufacturers instructions and as directed by Engineer-in-Charge.
S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S & F, steel windows with side hung shutters including projecting type hinges with steel handle & steel peg stay, complete with glazing bars, dovetailed or welded MAKE NCL eqv.
S & F, steel ventilators with top hung shutter including projecting type hinges with steel handle & steel peg stay, complete with glazing bars, dovetailed or welded MAKE NCL eqv.
M&L Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete.
S&F 4mm thick sheet glass ordinary quality fixing with putty/beading in square in each pane.
All as per Item here-in-above but figured glass pin headed type.
Taking down shutters of any description exc. 1 Sq.m and n.exc. 2 Sq.m each.
Taking down shutters of any description exc. 1 Sq.m and n.exc. 2 Sq.m each and refixing in same opening after easing and cutting to size in height as suitable.
S&F 35mm thick, 2nd class hardwood glazed & skelton shutters, open rebated & prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a).
S&F 100mm long SS butt hinges, medium weight cold rolled.
S&F 150mm long aluminium anodised barrel tower bolt of extruded section.
S & F 150mm long extruded aluminium alloy handles fabricated type anodised.
S&F 250mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete.
S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
M&L Preparatioin of new wooden surfaces of any description over 10CM width or girth and applying two coats of synthetic enamel paint over a coat pink primer.
M&L Preparatioin of old wooden surfaces of any description over 10CM width or girth and applying one coat of synthetic enamel paint.
S&F 1000 ltrs capacity ISI marked Rotational moulded polythene water strong tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed including taking down old unserviceable water tank.
S&F in repairs Ball valves high pressure of PTMT with eppoxy coated Aluminium rod & high density plastic ball screwed for iron pipes and fixed 25 mm bore (Minimum weight 455 gms)
S & F in repairs 15mm bore gun metal gate valves with iron wheel head screwed both ends for iron pipe and fixed.
All as per Item here-in-above but 20mm bore
M&L for Machine cut kota stone slab flooring 20 -25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slabd including rubbing and polishing complete
Taking down plain or corrugated steel sheeting, any gauge, thickness, including all type of sheeting in any position etc complete.
S & F in repairs 0.56mm thick plain aluminium sheeting, Alloy 31000H4 as in bottom portion of door shutters complete all as specified and directed.
S & F 2mm thick Fibre glass reinforced transulucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof wall etc.
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 medium grade
Providing precast cement concrete louvers and jallies 35 mm thick (measured solid) including all mouldings but excluding frame set in CM 1:4 Type Bo 1:2:4 12.5 mm graded aggregate
Dismantling water tanks of capacity exc 250 & n exc 500 Ltrs and removing to store complete all as specified and directed by Engineer-in-Charge.
S & F 500 Ltrs capacity Rotational moulded, polythene water storage tanks ( cylindrical shape with vertical top closed) hoisted and fixed in position all as specified and directed.
Fixing only water tanks removed under the relevant item. Note: Old retreived tanks shall be reused as directed)
S&F in repairs 20 mm bore dia ball valves, high pressure of PTMT with epoxy coated aluminium rod & high dencity plasstic ball screwed for iron pipe and fixed .(minimum weight 15 mm-142gms/20mm-210gms) all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore pipe all as specified and directed.
Demolition of cement concrete in roofs, floors (other than ground floors), etc. (unreinforced) including old tarfelt & cement mortor bedding and plastering etc complete all as specified and as directed and removed debris outside MD land.
Ditto- all as per item above, but reinforced cement concrete demoltion.
M & L cement concrete 1:2:4 Type B1 (using 20 mm graded stone aggregate) as in roof kerbs, bands etc .
M & L 25 mm thick plain cement concrete (1:2:4) type B0 using 12.5mm graded agg as in levelling/padding course on roof slab for water proofing treatment.
M & L rendering 10mm thick on concrete surface in CM 1:4 and finishing even and smooth without using extra cement with using WPC @ 3% by wt. of cement, complete all as specified and as directed (Note:- WPC will be measured and paid separately).
Supply only Liquid water proofing compound
M & L for cleaning the roof surface and applying oil bond bitumen primer @ 0.2 kg/sqm providing and laying 3mm thick APP modified water proofing membrane weight not less than 4kg/sqm reinforced with non woven polyester mat weighing not less than 160 gm/sqm having soften point not less than 140 degree centigrade tensile strength not less than 800 N/sqcm tearing strength 180N with minimum of 10cm side laps and 15cm end laps by application of torch applying a coat of blown grade hot bitumen over the membrane @ 1.2kg/sqm and providing garnish with solar reflective bitumen aluminium paint @ 0.1 kg/sqm over completed area of membrane complete all as specified and as directed by engineer in charge. Note: the quoted rate shall included for cutting grooves in roof parapets, upward facias, etc and inserting of membrane and making good with CM 1:3 wherever required all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for
M&L excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc, or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in hard/dense soil, complete all as specified and directed.
Returing filling in excavated material in any type of soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as directed.
Removing of excavated soil to a distance exceeding 50 mtr and not exceeding 100 mtr and depositing at places as directed by the Engineer-in-charge.
Cement concrete 1:4:8 Type D2 (40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L Formwork to sides and soffits of floor or roof beams, lintels and similar work fair finish surfaces
M&L Formwork to flat surfaces sides of pillars, posts, struts, piers, columns complete fair finish surfaces
M&L Reinforced cement concrete (nominal mix) Type B1 1:1.5:3 ( 20 mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L Reinforced cement concrete (nominal mix) Type B1 1:1.5:3 ( 20 mm graded aggregate) as in beams/band,candileavers, lintels over 1.5 mtr span
M&L Reinforced cement concrete (nominal mix) Type B1 1:1.5:3 ( 20 mm graded aggregate) as in columns, pillars, piers, post and struts all as specified and directed.
M&L Reinforced cement concrete (nominal mix) Type B1 1:1.5:3 ( 20 mm graded aggregate) as in columns, pillars, piers, post and struts all as specified and directed.
Dismantling of plain /corrugated steel sheeting any gauge, thickness including Ninital or similar pattern roof covering
S&F Framed work such as grills and gratings etc with end bars shouldered and or reveted conforming Fe-290 Grade E-165 including necessary weldings and achorage in to concrete complete all as specified and as directed
M&L for stainless steel letters of size height not less than 30 cm and 25 cm vide and thickness 20 mm to be fitted on granite stone all as directed and specified.
Taking down carefully copper/ aluminium point wiring (light, fan,socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface complete all as specified and as directed by the Engineer-in-charge.
Point wiring complete with 1.5 sq mm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn through and including non metallic, med. grade rigid PVC conduit with all conduit accessories and including provision of 1.5 sq mm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel terminal box made out of 1.60 mm thick MS sheet concealed in walls and covered with 3 mm thick hylum sheet for fixing the switches /sockets/ regulators etc.all specified for :-
(a) One light point controlled by one way switch .
(b) One exhaust fan point controlled by one way switch.
(c) One 3 pin socket outlet 5 Amps on the Independent board.
M&L for Sub main wiring complete with Two runs of 4 Sq mm Single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with One run of 4 Sq mm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including suitable size PVC casing and caping and accessories complete all as specified and as directed including taking down old U/S submain wiring. Note: Two runs of 4 Sq mm + One run of 4 Sq mm + PVC casing caping with accessories measure as a one unit.
S&F Switch Piano, flush type single pole, one way 5 Amps.
S&F Switch socket outlet, 2 in 1, flush type 5 Amps.
S&F ceiling rose 3 terminal PVC/Polycarbonate insulated body.
Supply & fix Highly durable surface mounted LED batten 4 ft 20W complete with LED constructed of fire retardant engineering grade extruded plastic and decorative end caps.
Supply & fix Highly durable surface mounted LED batten 2 ft 10W complete with LED constructed of fire retardant engineering grade extruded plastic and decorative end caps.
Supply and fix 20 Amps SP MCB metallic Plug and socket with enclosure.
Taking down old U/S DBs with fittings complete and making good all as specified and as directed by Engr-in-Charge
Supply & fix MCBs 'C' series 6-32A, SP, 230 volts 10KA suitable for fixing in MCB DB .
Supply & fix MCBs 'C' series 32A, DP, 230 volts 10KA suitable for fixing in MCB DB .
M&L for Distribution board when MCB for in coming and MCBs for out going to be used 12 way, 240 volts, double door complete as specified and as directed. Note: MCB will be measured and paid seperately under relevant items.
M&L for making hole in stone/brick masonary suitable for exhaust fan of size 380mm and making good all as specified and as directed by Engr-in-Charge
BEEGEE DESIGN SYSTEMS
AMK Builders
SAI RUPA CONSTRUCTIONS
VACON INFRASTRUCTURES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .