Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC 171 GLOBEL SPACE HUDA GLOBEL SPACE COLONY 125055 | SIRSA | HARYANA | 125055 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹6.0 L+₹90,741.06 (17.9%)Rejected-Finance | L2 | Rejected-Finance Higher rate to the contractor | |
| 3 | L3₹6.0 L+₹96,838.23 (19.1%)Rejected-Finance 134 BLOCK NO 2 HINDWAN HISAR HISAR | HISAR | HARYANA | 125001 | L3 | Rejected-Finance Higher rate to the contractor | |
| 4 | L4₹6.6 L+₹1.5 L (30.2%)Rejected-Finance | L4 | Rejected-Finance Higher rate to the contractor |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
23 Feb 2022, 5:00 pmClosed
Executive Engineer (M)
CCS HAU, Hisar
Repair renovation of office building of SNIATTE situated in Farm Area at CCS HAU, Hisar (including EI work)
2022_HRY_207519_1
3279-C
Open Tender
Civil Works
Works
90 days
CCS HAU
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹12,000
Yes
15 Apr 2022
10 Feb 2022
24 Feb 2022
10 Feb 2022
23 Feb 2022
10 Feb 2022
Amount
Civil work 1 to 18:- Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar (HSR 5.7.4)
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 sqm mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. (HSR 5.42)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (HSR 5.70)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size) (HSR 6.3.1)
Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR 6.13)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)
Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (HSR 10.70.2)
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Flush / Ruled/ Struck or weathered pointing (HSR 11.25.1)
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 11.58)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer (HSR 11.64.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/1 O sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (HSR 11.95.1)
Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (HSR 30.19)
Flush pointing with cement mortar 1: 3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for prefixed flat tile bricks on top of mud phaska: With F.P.S. brick tiles (HSR 30.20.1)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (HSR 30.21)
Providing and fixing PVC wall paneling consisting of 7mm thick cactus make hollow PVC section, PVC U section beading of size 25mmx8mmx12mm and PVC angle nosing of size 25mmx25mmx1.5mm including cost of PVC gutties, screws, jointed with polyfix (instant glue), complete in all respect as per drawing or as directed by Engineer-in-Charge. (NS)
Electrical work 19 to 36:- Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1)
1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2)
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.1.2)
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B (HSR 23.4.4.2)
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 1&2 Modules (HSR 23.8.10.1)
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. Bell Push (HSR 23.8.11.6)
Step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7)
RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable (HSR 23.8.11.11)
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. (HSR 23.22.4.2) SPN DB Double Door 16 way ( 2 incoming and 14 outgoing )
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- SP MCB 6-32 AMP (HSR 23.22.5.1)
SPN MCB 6-32 AMP (HSR 23.22.5.3)
TPN MCB 40-63 AMP (HSR 23.22.5.6)
40 amp to 63 amp. MCB's FOUR POLE. (HSR 23.22.5.8)
MISCELLANEOUS Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required 15 mm dia (HSR 23.23.2.1)
S/E/T/C of Cat-6 cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect. (HSR 23.23.9)
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor >0.95, CRI >80, Average life >50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial) Make: Philips, Havells, Wipro, Bajaj. (NS)
S/I/T/C iof push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to complete the job upto entire satisfaction of Engineer-in-charge (NS)
SHRI RAM CONTRACTOR AND SUPPLIER
Ajay Contractor
Varun Kumar Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .