Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹49.3 L+₹93,130.60 (1.93%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹49.8 L+₹1.5 L (3.00%)Rejected-Finance C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹51.4 L+₹3.0 L (6.29%)Rejected-Finance V P O JAGANOO TEH DISTT UDHAMPUR J K 182124 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹52.0 L+₹3.7 L (7.58%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹67.5 L
EMD Value
₹1.3 L
Closing Date
18 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR OF GOVT MD ACCN BLDG NO P-46 (BIKRAM ENCLAVE) UNDER GE (SOUTH) UDHAMPUR
2023_MES_573722_1
CWE/U(S)-80/2022-23
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
AS PER TENDER
7 documents required · 7 mandatory
₹1,000
GE (S) UDHAMPUR
₹1.3 L
Yes
15 Apr 2023
7 Jan 2023
25 Feb 2023
7 Jan 2023
18 Feb 2023
28 Jan 2023
Amount
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) exceeding 15 cm thickness but above ground floors, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles 350mm x 200mm x 7 to 8mm /450 mm x 300 mm x 7 to 8mm thick on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over & including 10mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge
Non skid, joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match, over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 06 above but in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering (backing) on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Calling Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified.
Machine cut kota stone slab flooring 10-12 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
150mm wide strip of makrana white marble 18-20 mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 20 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and mirror finish polishing over and including 20 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge double moulding), such as in steps, cooking platform, and other similar situations including mirror finish polishing complete all as specified and as directed by Engineer-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
10mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Supply only Integral water proofing compound, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 20 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
S&F for Solid frame wooden high density filament (HDF) double rebated of size 125 x 55 mm processed with polyole fins different wood fibre, fixed to opening including necessary fixing lugs, hinges, lock strike plate etc. complete, all as specified and as directed by Engr-in-Charge.
Solid PVC Door Frame of size 50mm x 95mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
S&F 35 mm thick HDF prelaminated (weng a/teak colour) moulded shutter 35 mm thick puf (poly ucrane from) insulation with minimum density 40 kg/cum filled in between two HDF sheets of thickness 3.2 mm both & border covered with 10mm thick PVC sheet complete in all respect with lock rail & beautified by PVC bedding all around with PVC solvent complete all specified and as directed.
S& F Prelaminated 18/19mm thick lead factory made 100% solid WPC (wood poltmer composite) sheet having natural fibre conter 25 to 30% wood colour sheets with density not less than 500 kg/cum and the weight of sheet of 1 sqm should be 11 kg (+/- 5%) manufactured by ISO 9001-2015 certified company the sheet should be 100 % water proof, termite proof, fire ratardant, manufactured by single layer extrusion process with excellent screw holding capacity and shore D hardness, complete all as specified and as directed by Engr-in-Charge.
18/19mm thick Prelaminated particle board, termit proof, chemically well pressed, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, shelves etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
S&F 34/35mm thick factory made single piece wire gauge door/ shutter solid PVC UV printed doors-wood free consisting of 5mm thick solid PVC sheet on both side (both side multi color UV printed using steel/ aluminium XPM/ wire mesh and consisting frame made out of M.S tubes 19 guage thickness and size of 19mm x 19mm for stilies and 19mm x 19mm for the top, bottom and lock rails with PVC beading in all around M S frame shall have a coat of metal primers. MS frame shall be covered with heat moulded (Rigid) 20/22mm PVC solid sheet at styles, top rail and bottom rail (Rigid) MS frame welding sealed to the style and with suitable PVC sheet beading and joined together with solvent complete all as specified and as directed. Note: The shutter is to be fixed with 50mm size self drilling star screws full threated.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per item above No 29 but without glazing bar complete all as specified and as directed.
Factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-O or Gde-E-165, complete all as specified and as directed.
3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
3 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples complete, all as specified and directed by Engr in Charge.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 38 above but except brick.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 20mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.50 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed by Engr-in- Charge.
Cement concrete tiles 20cm x 20cm and 20mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey cement and in floors, and cut and polished , over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge. complete all as specified. complete all as specified.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
250 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed by Engr-in-Charge.
Continuous (piano) hinges width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised, complete all as specified and directed.
100mm size hasp and staple safty type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified.
200 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm size extruded aluminium alloy handles (ISI Marked), fabricated type., anodised, complete all as specified and directed by Engr-in- Charge.
2nd class hard wood small fittings such as shaped door & window stops, cleat including all necessary labour, articles not exceeding 200 cubic centimetre each complete all as specified and as directed by Engr-in-Charge.
Mild steel cold rolled butt hinges (ISI Marked) 'Medium weight' 100 mm size, fixed to steel/angle iron frame by welding , if required complete all as specified and directed by Engr-in- Charge.
Description all as per item No 52 above but 75 mm .
Mild steel, 300 mm, ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified.
200 mm long, mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, complete all as specified and directed by Engr-in- Charge.
Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by Engr-in- Charge.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware fixed in repairs complete, all as specified and as directed by Engr-in-Charge.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide/ zink chrome primer complete all as specified.
Applying 1 mm thick a layer of wall care putty including preparation of new plastered/ unplastered surfaces of wall to give uniform surface, complete all as specified & directed by Engr-in-Charge.
Preparation old surfaces plastered or unplastered and applying two coats of white wash on ceiling, complete all as specified and as directed by Engr-in-Charge.
Preparation new surfaces plastered or unplastered and applying two coats of white wash on ceiling, complete all as specified and as directed by Engr-in-Charge.
Applying two coat of oil bound distemper over and including a coat of primer including preparation of old plastered surfaces of wall.
Applying two coat of oil bound distemper over and including a coat of primer including preparation of newly plastered surfaces of wall.
Preparing old plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed by Engr-in-Charge.
Preparing new surfaces, plastered or unplastered of wall and applying two coats of weather proof exterior emulsion paint (Apex Ultima or equivalent of makes mentioned in PS) over one coat of primer of any description/colour as approved, complete all as specified and as directed by Engr-in-Charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, complete all as specified and directed.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed.
S&F MS flat iron as in wind ties etc., confirming to Fe- 290 Gde-165 including iron clamps, complete all as specified and as directed by Engr-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position as in unframed work, complete all as specified and as directed by Engr-in-Charge.
Mild steel Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails guides for sliding doors, and vertical posts of pipes sections fixed with angle cleats or other connecting plates, Fe-410-W (Gde - E -250), complete all as specified and as directed by Engr-in-Charge.
Vitreous china water closet, 'Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Supply only cast iron P or S traps 100 mm size, complete all as specified and as directed.(ISI Mark)
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Supply only 32 mm dia PVC waste pipe, for low level cistern, complete all as specified and as directed by Engr-in-Charge
Stainless steel grating doom 75/100mm dia square or round fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs fixed in repairs complete alll as specified and as directed,
PVC connections 15 mm size with PTMT nuts of length 450 mm and washers, complete all as specified and as directed by Engr-in-Charge.
Magic eye, brass, chromium plated, fixed in main door complete all as specified and as directed by Engr-in-Charge.
Steel peg set colour coated of six as per sample in repairs complete all as specified.
Sinks made of stainless steel with draining board, made out of 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar including fixing cantilever brackets connecting union to pipe and 32mm dia GI pipe duly painted upto Nihani Trap or Floor trap complete as directed at site, overall size 495mmx420mm bowl size 410mm x 330mm x160mm, in repair complete all as specified.
Plate rack made of stainless steel, 600 x 750X0.55mm including fixing as per manufacturers instruction complete all as specified.
PCC 1: 3 : 6 type C2 (using 40 mm graded aggregate) in surafce channel and drains incl necessary formwork, complete all as specified.
Plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregates as insunken floor/ foundatiom, complete all as specified and as directed by Engr-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes, upto 100 mm internal dia jointed in cement mortar and taking out of trenches or fixed to wall, if required complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 100mm bore duly apply a coat of bitumenous black paint, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 89 above but 75 mm bore pipe.
Description all as per item No 89 above but 50 mm bore pipe.
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore pipe, fixed in repair, all as specified and as directed by Engr-in-Charge.
Description all as per item No 92 above but 75 mm bore pipe.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore pipe, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore pipe, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches for 75mm bore pipe fitted with oval access door, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches for 100mm bore pipe fitted with oval access door, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, fixed to wall, fixed in repairs, complete all as specified and as directed by Engr-in- Charge.
110 mm bore PVC SWR bends and fixed solvent etc fixed in repair complete all specified and as Directed (ISI Marked)
Cast iron vent cowl for 75mm bore pipe, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Cast iron vent cowl for 50mm bore pipe, fixed in repair complete all as specified and as directed by Engr-in-Charge.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4) , fixed in repair , complete all as specified and as directed.(ISI Mark)
Cast iron lid for oval access door of bends for 75mm bore pipes and fixed including necessary threading and nut/bolts as required complete all as specified and directed by Engineer-in-Charge
Cast iron lid for oval access door of bends for 100mm bore pipes and fixed including necessary threading and nut/bolts as required complete all as specified and directed by Engineer-in-Charge
Soap dish holder, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Towel rack, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
S&F in repair Front Glass shelf with chromium plated guard rails, complete all as specified and as directed by Engr-in-Charge.
S&F in repair Corner Glass shelf with chromium plated guard rails, complete all as specified and as directed by Engr-in-Charge.
15mm bore centre hole basin mixer without Popup waste system with 450mm long braided PVC hoses, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
15mm bore chromium plated mixer with swinging casted spout (wall mounted model), fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Bib taps long body, fancy type, cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed by Engr-in-Charge.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed by Engr-in-Charge.
Angular stop cock , brass chromium plated, screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixing in repair, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC connection 15mm bore 450mm long braided hose with M10X1 Nipple, 15mm Nut, O-Ring & Rubber washer (Suitable for basin Mixers), complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC connection 15mm bore 450mm long braided hose with two 15mm Nut, O-Ring & Rubber washer (Suitable for basin Mixers), complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair, complete all as specified.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm fixing in repair,complete all as specified.
Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Stop valves, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm fixing in repair , all as specified.
Bib taps , cast copper alloy, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed by Engr-in-Charge.
Brass chromium plated shower rose 125mm size with arms, round shape, swivel type, Chrome plated fixing in repair, complete all as specified.
Dismantling water tank of capacity exceeding 250 litres but not exceeding 500 ltrs each and removing from site/to store, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified.
75 mm thick, Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base for laying floor finishes including finishing the surfaces even and rough , complete all as specified and as directed by Engr-in-Charge.
Factory made, Machine pressed / vibro mechanically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment including 30 mm thick sand cushioning bed including spreading levelling watering if required, Shape shall be approved by Engr-in-Charge.
Removing excavated material exc. 500m but not exc 1.5 km and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Machine pressed (factory made) precast plain cement concrete 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in kerb stone of size 300mm x 300mm x 100mm thick and the like with plain fair faces including chamfering, weatherings, etc., embedding in position/laid in trenches on edges of roads including necessary formwork, including excavation in any type of soil, returning filing and removal of surplus soil/debris to a distance not exc 50 m from the starting point and including bedded, jointed and setting in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Broken stone hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engr-in-Charge.
Dismantling existing abondoned manholes of any size and any depth including removing all debris and making the surface levelled by filling earth/soil complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
M&L for mild steel steel TMT bars 6mm to 8mm dia and over cut to length bent to shape reqd incl cracking bvending spirally for hoping columns hooking ends and binding with mild steel wire annealed not less that 0.9mm dia all as specified.
Framed work of angle or other sections such as frames of manhole covers, hold fasts and similar work conforming to Fe-410-0 ,complete all as specified and as directed by Engr-in-Charge.
Pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab, chullah hoods and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Providing, Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and as directed by Engr-in-Charge.
Cleaning of manholes not exc 1.50m deep and removing sludge/waste materials etc. to a distance not exc. 1.50m and burrying in pits including filling pits with earth, complete all as specified and as directed by Engr-in-Charge.
Cleaning of gully traps of any size and burrying in pits the waste materials after removing upto 50 metres, complete all as specified and as directed by Engr-in-Charge.
Cleaning of drain pipes 150mm bore by rodding from manhole to manhole or manhole to septic tank or vice versa and well flushing with water after cleaning (the rates include for taking off manhole covers and replacing, removing the sludge and burrying in pits at a distance not exc. 50m), complete all as specified and as directed by Engr-in-Charge.
Cleaning of drain pipes 100mm bore by rodding from manhole to manhole or manhole to septic tank or vice versa and well flushing with water after cleaning (the rates include for taking off manhole covers and replacing, removing the sludge and burrying in pits at a distance not exc. 50m), complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Demolition & breaking up SGSW drain pipes of 100/150mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified.
150mm bore salt-glazed stoneware drain pipes of grade 'A' laid in trenches and jointed as specified, complete, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes all as specified.
200mm bore salt-glazed stoneware drain pipes of grade 'A' laid in trenches and jointed as specified, complete, complete all as specified and as directed by Engr-in-Charge.
Extra for forming fair finished drain or channel exc 30cm inner girth in cement concrete ,using extra cement ,incl forms moulds ,mitered/stopped ends etc
PCC 1: 3 : 6 type C1 (using 20 mm graded aggregate) in surafce channel and drains incl necessary formwork, complete all as specified.
Provision of Soakage well of size 3m (dia) x 3.0m (depth), including necessary excavation and earthwork, in any type of soil, PCC foundation, brick work in CM 1:6 (wall shall be honey combed as shown on drawing), RCC cover slab in M-25, filling the well with brick bats, complete all as specified, as directed. Note: 1. The drawing has not been made part of the tender document and it is assumed that the tenderers are in possession of the said drawing before quoting their bids being typical detail drawings. However the bidders are free to visit any MES office for refering the same during office hours. 2. RCC shall be M-25 grade design mix irrespective of whatever mentioned in drawing. 3. Foundation PCC shall be 1:3:6 type C-2 irrespective of whatever mentioned in drawing.
Provision of septic tanks (for 100 users), including necessary excavation and earthwork in any type of soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC cover slab including RCC precast manhole cover having 6mm plate embedded all around/ fibre reinforced cover with angle iron frame, vent shaft and sludge chambers etc. complete all as specified, as directed. Note: 1. The drawing has not been made part of the tender document and it is assumed that the tenderers are in possession of the said drawing before quoting their bids being typical detail drawings. However the bidders are free to visit any MES office for refering the same during office hours. 2. Depth of inlet pipe from ground level shall be 70 cm. 3. RCC shall be M-25 grade design mix irrespective of whatever mentioned in drawing.
Demucking of filled soil in drains of any size, any depth or any section in any condition as per site requirement including removing the excavated/demucked materials to a distance not exceeding 50m and spreading along road side berms complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exceeding 20 cm wide, etc. to obtain rough flat finished surface of concrete complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete 1:2:4 type B-I using 20mm graded aggregated stone aggregates as in lintels upto 1.50 metre clear span,cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form works complete all as specified and as directed by Engr-in-Charge.
Walling of random rubble stone masonry uncoursed, with best quality locally available harder stones such as granite, trap, basalt, trap, basalt stone etc, well bonded, bedded and solidly hearted , built in cement mortar 1:6 complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-1 (using 40mm graded crushed stone aggregates) as in surface channels and drains, complete all as specified and as directed by Engr-in-charge.
Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and as directed by Engr-in- Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or as in weep hole, complete all as specified and as directed by Engr-in- Charge.
Providing precast cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry/ kerbs), string courses, copings. kneelers, apex stones, pier aps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair aces, including chamfers, weatherings, throat- ing etc. and setting in cement mortar 1:6, complete with joints to match, complete all as specified and as directed by Engr-in-Charge.
Raised pointing to random or polygonal rubble stone Masonry, uncoursed or brought upto courses, in cement mortar 1:3 complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for one light / fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer sheet for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly,fixed in repair, complete all as specified & directed by Engr-in-Charge. Note: Modular metal flush boxes & cover plates deemed to be included inquoted rate.
Description all as per item No 169 above but one 3/5 pin 6 Amp socket outlet on independent board .
Description all as per item No 169 above but one 3/5 pin 6 Amp socket outlet on the same board with other switch.
All as per description of Serial item No 169 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 169 above but for light point controlled by 2-two way switches
Switch piano , single pole,1 module, two way ,10 Amp (modular type) , fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole,1 module, one way ,6 Amp (modular type) , fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole,1 module, one way ,16 Amp (modular type) , fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Bell push Modular type, 1 module, 6 Amps 230 volts including taking down old AC bell push complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 module, combined 3 pin, 6 Amp flush type modular type, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 module, 2 in 1- 3 pin combined , 6 & 16 Amp flush type modular type, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, 2 module, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, fixed in repair ,complete all as specified and as directed by Engr-in-Charge.
Supply and fixing sheet metal enclosures for DBs when MCCBs to be used double door DB VTPN 4 ways, vertical type with 400 Amps rated bus bar and neutral link including chases wall for fixing DB and making good disturbed wall surface to match with existing specifications, fixed in repair, complete all as specified and directed by Engr-in-Charge. (Including all PCC & cementing work for installation of TPN DB to wall).
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
Material and labour for replacement MCCB 100 Amps, 4 Pole, 16KA, 415 Volts. Complete all as specified and directed by Engr-in-Charge.
MCB SPN, 32 to 40 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 10 to 40 Amps,240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
M&L for sub main wiring with copper conductor cable (2 runs of cable) multistranded 4 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC rigid concealed conduit not less than 25 mm dia and 2 mm wall thickness ISI marked medium grade , with all conduit accessories for power pint snad single phase ACs such that GI shadle, GI screw, rowl plug etc. including cutting chasing and 1X4 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire, fixed in repair, connected to common earth and earth duly complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 191 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Taking down old serviceable/ unserviceable Electric meter including meter box from existing position carefully refixing including making good to disturbed surfaces , complete all as specified and as directed by Engr-in-Charge.
Taking down ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as per the directions of Engr-in-Charge.
Angula lamp holder, PVC/Polycarbonate type with cord grip cap suitable for light fittingsl, complete all as specified and directed by Engr-in-Charge.
LED Bulb, 15 Watt, 230V, suitable for angular lamp holder complete all as specified and directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +50 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 32mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , complete all as per the direction of Engg-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
S&F for modular socket outlet single with inner and outer cover strip required module including TV cable required length from roof, complete all as specified and directed by Engr-in-Charge.
Removing and refixing only LED light fittings 5W to 20W, 220V, decorative box type with driver, holder including LED tube lights C&S make connecting up with three core flexible copper conductor cable of suitable size for ceiling rose, complete all as specified & directed by Engr-in-Charge.
Removing and refixing only water heater/geyser, 25 litre capacity 220V, AC single phase including nut bolt, copper conductor cable of suitable size, complete all as specified & directed by Engr-in-Charge.
paras ram pachiala
M/S ASHOK KUMAR PACHIALA
HANS RAJ SHARMA
RAMAN CONSTRUCTION CO
TULSI RAINA AND SONS
SHIVAE CONSTRUCTION
KALSOTRA CONSTRUCTION CO
khajuria builders
jyoti parkash sharma
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .