Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹5.2 L+₹35,789 (7.37%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹5.7 L+₹82,305 (16.9%)Rejected-Finance DEVERTHA NO 1 SHAHGANJ AGRA | AGRA | AGRA | UTTAR PRADESH | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹11,000
Closing Date
10 Jul 2021, 6:00 pmClosed
Maj Vijay Kumar Sharma
Garrison Engineer West 62 Station Road Agra Cantt
PROVISION OF PARKING AREA NEAR OFFICER S MESS ADDN ALTN TO FOL STORE OF HQ AFSOD OF GE W AGRA
2021_MES_444252_2
8012/803/E8
Open Tender
Civil Works
Item Rate
120 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹11,000
2 Sept 2021
25 Jun 2021
13 Jul 2021
25 Jun 2021
10 Jul 2021
25 Jun 2021
Amount
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified & as directed.
M&L cement concrete1:2:4, type B-2 (using40 mm graded stone aggregate) in foundations, filling and mass concrete all as specified & as directed.
M&L 100 mm thick PCC1:4:8, type D-2 (using 40 mm graded stone aggregated ) as in sub base complete all as specified & as directed.
M&L machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment including sand bed cushioning 25 mm thick complete all as specified & as directed.
S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410W(GdeE-250) quality B complete all as specified and directed.
S & F MS pipe as in post using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S & F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed.
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or grith and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified & as directed.
Demolition of cement concrete (unreinforced) in any position not exc 15cm thickness (above ground level) complete all as specified and directed.
M&L cement concrete type B-1, 1:2:4 mix ( 20 mm graded agg) in padding, roof kerbs or mud stops, rounded or chamfered on edges and similar work including necessary use & waste of formwork all as specified and directed.
M & L for water proofing treatment of roof slab all as followes: - (a) Preparation of roof surfaces by brushing, cleaning and applying 15mm thick plaster in CM 1:4 with water proofing compound as per manufacturer's instruction. (b) Applying a priming coat with bitumen primer @ 0.5 ltr/Sqm (c) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (d) Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen. (e) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and sand in confirming to Zone II in dry condition shall be dusted over the bitumen @1.00 Kg/Sqm Note : WPC shall be measured and paid separately under respective item
M&L for surface excavation n.exc. 30 cm deep and averaging 12cm deep and getting out inloose/soft soil complete all as specified & as directed.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface complete all as specified and directed.
M&L for 15mm thick rendering plastering in CM 1:4 on brick or concrete surface with water proofing compound as per manufacturer's instructions, finishing even & smooth without using extra cement complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
Supply only integral water proofing compound complete all as specified and directed.
M & L for rendering 10mm thick plastering in CM 1:3 on ceiling surface finishing even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of cement base paint over a coat of priming paint complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying two coat of weather proof paint (APPEX Paint) complete all as specified and as directed
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection (75 mm thick) laying in alternate ways finished even and fair without using extra cement complete all as specified and directed.
M&L for plain cement concrete 1:2:4, Type B-1(using 20mm graded stone aggregate) 40mm thick as in floor complete all as specified and directed.
M&L sand cushion as in floors of FOL store complete all as specified and as directed.
M&L dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
M & L cutting holes into or through brick wall built in cement mortar superfacial area exc 150 Sqcm but n exc 400 sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F mild steel joist channel, angle or tee sections fixed independently with out connecting plates etcof grade fe-410-0 & fe 310-0 complete all as specified and directed.
M&L for steel (Fe-290, Gde E-165) framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L 1.25mm thick Mild steel, plain black steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S & F Mild steel angles, bars, flats etc., hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 290 complete all as specified and directed.
Material & labour PCC 1:2:4, type B-0 (using12.5mm graded stone aggregate) for fixing hold fasts, angle etc complete all as specified and directed.
S & F Mild steel work in framed work such as grills, gratings, guard bars etc, with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified & directed.
M&L for preparation of old paint on steel and iron surfaces of any description not other wise described over 10 CM width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down chowkats or frames n' exc 1.50 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed.
S & F galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
M/s Sharda Costruction Company
M/S Solanki Brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .