Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹53.6 L+₹8.8 L (19.7%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted |
Tender Value
₹46.9 L
EMD Value
₹93,900
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_491556_1
8400-703/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
PANAGARH
Class D, Cat a (i) and b (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹93,900
Yes
4 Jan 2022
30 Nov 2021
29 Dec 2021
30 Nov 2021
27 Dec 2021
13 Dec 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Excavation over areas n. exc 1.50m deep and getting out in soft/loose soil complete all as specified and directed
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for hardcore of broken stone boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for sand filling under floor in foundation including watering and consolidation complete all as specified and directed.
M&L for cement concrete 1:4:8, Type D-2 (Using 40 mm graded stone aggregates) in foundations etc complete all as specified and directed.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs complete all as specified and directed
M&L for two coats of weather proof paint on newly plastered surfaces over a coat of chalk whetining including preparation complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4),complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with mixture of grey cement and pigment complete all as specified and directed.
E/M Portion M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres with top edge of the plate not less than 1.5 metre below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150mm to a packed thickness of 150 mm on all sides with and including necessary exacavation earth work including GI strip 25 X 4 mm as earthing lead connected with bolted and reverted to earth plate at one end in and connected to continuous GI strip 25 X 4 mm and including all as shown in electrical plate No 5 including taking down old one complete all as specified and directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, commissioning and testing Outdoor type LT Distribution Panel, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x2200 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-250 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (Make - GE/Schneider/Seimens) (d)MCCB-200 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 Nos(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-160 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-03 No(Outgoing) (Make - GE/Schneider/Seimens) (f) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make - GE/Schneider/Seimens) (g) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos (Note: (i) PCC rate for foundation to be included in this item rate. (ii) All accessories for LT distribution panel must be OEM recommendation.)
Supply, commissioning and testing Outdoor type LT Distribution Panel, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 2200 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. . New Panel board shall comprise of :- (a) Copper Busbar rating- 800 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) ACB - 630 Amp, 4 pole, 50 KA Manually operated, microprocessor based, 415 V, 50 Hz AC-01 No(Incoming) (Make - L&T/Schneider/Seimens) (d) MCCB-250 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-200 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 Nos(Outgoing) (Make - GE/Schneider/Seimens) (f) MCCB-160 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-03 No(Outgoing) (Make - GE/Schneider/Seimens) (g) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (h) S&F digital multimeter meter 3 line display to show Voltage and Current having CT for measurement 800 A current and 0-500 Volts in Three phase system (j) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (k) S & F digital voltmeter 0-500 V = 01 Nos (Note: (i) PCC rate for foundation to be included in this item rate. (ii) All accessories for LT distribution panel must be OEM recommendation.)
Supply, commissioning and testing Outdoor type LT Distribution Panel, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 200 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-250 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (Make - GE/Schneider/Seimens) (d) MCCB-160 Amp, 4 pole, 25KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (f) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (g) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-06 No(Outgoing) (Make - GE/Schneider/Seimens) (h) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (j) S & F digital voltmeter 0-500 V = 01 Nos (Note: (i) PCC rate for foundation to be included in this item rate. (ii) All accessories for LT distribution panel must be OEM recommendation.)
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for wiring socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC casing caping and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified.
S&F switch socket combination 16 Amps flush type controlled by one switch complete all as specified and directed.
S&F double door refrigerator, electric driven (Single Phase) of capacity 310 Ltr ,ISI marked,240 Volts complete all as specified and directed. (Make: M/s Whirlpool/ M/s Kelvinator/ M/s LG)
M&L for wiring socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC casing caping and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor, PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
S&F switch socket 2 in 1 multipurpose 5 pin, (6 Amps) complete all as specified and directed.
S&F Wall Fan of sweep 400mm with metal blade,240 volts,steel body, BEE 5 star rated, ISI marked complete all as specified and directed by Engr-in-Charge.
M&L and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 400 Sqmm 3.5 core complete all as specified and directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
All as per item No 26.00 mentioned here-in-above but 240 Sqmm 3.5 core complete all as specified and directed
All as per item No 26.00 mentioned here-in-above but 120 Sqmm 3.5 core complete all as specified and directed
All as per item No 26.00 mentioned here-in-above but 95 Sqmm 3.5 core complete all as specified and directed
All as per item No 26.00 mentioned here-in-above but 70 Sqmm 3.5 core complete all as specified and directed.
All as per item No 26.00 mentioned here-in-before but 50 Sqmm 3.5 core complete all as specified and directed
All as per item No 26.00 mentioned here-in-before but 16 Sqmm 4 core complete all as specified and directed Note: (For Sl No 26 to 32) : Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punned down to a thickness of 18 cm complete all as specified and directed. (Note : Punned thickness shall be measured).
M&L for laying Fly Ash bricks for cable protection complete all as specified and directed.
M&L for 80 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint complete all as specified and directed. (Make: M/s TATA/M/s JINDAL/M/s PRAKASH).
M&L in repair 40 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint complete all as specified and directed. (Make: M/s TATA/M/s JINDAL/M/s PRAKASH).
M/S JK TRADING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .