Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹42.8 L+₹74,294.25 (1.77%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹42.9 L+₹90,445.75 (2.15%)Rejected-Finance | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹43.0 L+₹97,581.50 (2.32%)Rejected-Finance CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | L4 | Rejected-Finance Rejected being 4th Lowest Bidder | |
| 5 | L5₹43.9 L+₹1.8 L (4.31%)Rejected-Finance | L5 | Rejected-Finance Rejected being 5th Lowest Bidder |
Tender Value
₹42.6 L
EMD Value
₹85,160
Closing Date
24 Jun 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-74 OF 2019-20 SPECIAL REPAIRS TO BUILDING NO. P-28 (CIVIL MES MARRIED ACCOMMODATION) ALONGWITH CONNECTED ITEMS AT MILITARY STATION ABOHAR
2020_MES_325792_1
CA NO. CWE SGNR - 74 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
ABOHAR
Class D
Category a(i)
10 documents required · 10 mandatory
₹500
GE ABOHAR
₹85,160
Yes
7 Jul 2020
27 May 2020
26 Jun 2020
27 May 2020
24 Jun 2020
10 Jun 2020
Amount
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) in roof , floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspepnded work complete all as specified and directed by Engineer-in-Charge.
Demolition of mud in roofs any thickness incl plastering and leeping complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick tiles or terracing tiles in roofs single layer complete all as specified and directed by Engineer-in-Charge.
M & L for 50mm thick cement concrete type C2 1:3:6 (40mm graded aggregate) as in plinth protection , surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-0 as required (superficial area n. exc 150 sq cm) complete all as specified and directed by Engineer-in-Charge.
M & L for mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 7 here-in-before but for 5 mm dia and over up to and including 8 mm dia as in stirrups complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in as in foundations, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Columns, pillars, piers, posts & struts etc. complete all as specified and directed by Engineer-in-Charge. Note : form work & reinforcement measured separately
M&L for Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5 metre span complete all as specified and directed by Engineer-in-Charge. Note : Form work & reinforcement measured separately
M&L for Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. Note : Form work & reinforcement measured separately.
M&L for Form work to sides of concrete fdns, footings bases of columns and plinth beams and similar works rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs, such as roof slabs, floor slabs landing and similar work not exceeding 200mm thick (Horizontal & sloping) fair finished surfaces complete all as specified and directed by Engineer-in-Charge. Note- Steel props to be use
M&L for From work to edges of concrete flates treads breaks in floors, window cill concrete railing, opening in convert valley floor and roof exc 10 cm but n.exc 20 cm wide and sides RCC/PCC band in walls complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides of pillars, posts, struts, piers columns & stanchions : rough finished surface of flat concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer-in-Charge.
S & F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick work built in cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 20 here-in-before but for except bricks complete all as specified and directed by Engineer-in-Charge.
M & L for brick work in half brick thick wall using fly ash bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices complete all as specified and directed by Engineer-in-Charge.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over 10mm thick cement sand (1:4) as in backing coat complete all as specified and directed by Engineer-in-Charge.
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 26 here-in-before but for in skirting over 10 mm cement mortar backing (1:4) complete all as specified and directed by Engineer-in-Charge.
M & L for Machine cut kota stone slab flooring 18 - 20 mm thick over cement screed base laid over and including 15mm thick screed bed in cement mortar 1:6 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M & L for Machine cut kota stone slab 18 - 20 mm thick in riser of steps,skirting,dado and pillar over cement screed base laid over and including 10mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 18 - 20mm thick(of any type) works (table rubbed and polished) in step, window cills, cooking platforms and the like in cement mortar (1:4), 20 mm thick including pointing in white cement (1:2) using marble dust with admixture of pigments to match complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as specified and directed by Engineer-in-Charge.
S&F for "fiberways" brand fiber glass reinforced plastic (FRP) Door frame of three legged of cross section 90x45 mm size single nrebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame moulded with two resistant grade unsatratedpolyster plain and chapped mat door frame laminate shall be 2mm thick and shall be filled with subbish wooden block in all two three legs . the frame shall be covered with fibre glass from all side. MS stay shall be provided at the bottem to steady the frame complete all as specified and directed by Engineer-in-Charge.
S&F for "fiberways" brand 30mm thick glass fiber reinforced plastic (FRP) panelled door shutter of required colour are approver brand and manufacture made with fire resistance grade unsatratedpolyster plain moulded to 3mm thick fiber laminate for foming hollow ralliuded styles with wooden frame and suitable blocks of sessoned wood inside at required place for fixing of fiber-cast monolithitically with 5mm thick FRB laminated for panels and conforming to IS-4858-2000 complete all as specified and directed by Engineer-in-Charge.
S & F for PVC butt hinges, medium weight 100 mm size fixed with steel screw complete all as specified and directed by Engineer-in-Charge.
S & F for tower bolt 150 mm of PTMT complete all as specified and directed by Engineer-in-Charge.
S & F for door handle D type 150 mm of PTMT complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down shutters refixing in same opening but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm complete all as specified and directed by Engineer-in-Charge.
Taking down shutters but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm complete all as specified and directed by Engineer-in-Charge.
S & F for Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S & F for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed by Engineer-in-Charge.
S & F for Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
S & F for pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 105X60mm complete all as specified and directed by Engineer-in-Charge.
S & F for pressed steel door frames size of 125X60mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:3:6 type C-1 for filling of pressed steel fram and hold fast blocks etc complete all as specified and directed by Engineer-in-Charge.
S & F for aluminium tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long complete all as specified and directed by Engineer-in-Charge.
S & F for aluminium bow handle stove enamelled black, 150 mm long complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel sliding door, bolts 250mm long, plate type, stove enamelled black with bright bolt not less than 12mm dia, with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified and directed by Engineer-in-Charge.
S & F for small fittings such as door stops and like, including all necessary labours articles not exceeding 200 Cucm each of 2nd class hard wood complete all as specified and directed by Engineer-in-Charge.
S&F for hasp & staple size 125mm safety type aluminium anodised with hinges pins incl bolt to hinge plate fixed with screw complete all as specified and directed by Engineer-in-Charge.
S&F for peg set of stainless steel solid body of 125mm to 175 mm having 6 Nos hooks fixed with brass chromium plated screws complete all as specified and directed by Engineer-in-Charge.
S& F in repairs Drapory curtain rod of 25 mm dia decorative type with brass coated ends caps includinf fixing arragements like brackets,stops,rollers etc. complete all as specified and directed by Engineer-in-Charge.
S&F for Factory made box type steel window/Ventilators with hung shutter both glazed and gauged ,shutter frame 60x25mm ERW hollow 'P' section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx 70mmx1.6mm thick including fixing glazed portion,iron grills 8mm suare MS bar hunges with steel handle and fitting, lugs etc, including one coat of primer complete all as shown in drg No BTD 889 sheet 1/4 to 4/4 complete all as specified and directed by Engineer-in-Charge. Note :- Wire mesh and glass shall be measured and paid separately under relevent items of BoQ
S & F for 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S & F for figured glass 4 mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each pan complete all as specified and directed by Engineer-in-Charge.
M & L for providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engineer-in-Charge.
S & F for framed work such as grills, cooler stand ,grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S & F for structural steel work rolled mild steel joist, channel,angle,or Tee sections, fixed independently conforming to Fe 410-W complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel bolts purpose made with hesagonal or square head one end and screwed to other, or screwed to both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 12mm dia and not exc 20mm dia and exc 30 cm long complete all as specified and directed by Engineer-in-Charge.
M&L for plates (plain or chequered) channels , square cut or notched (ordinary and counter sunk) forming holes , without any attachment Fe-415 -W (Gde -e -250) quality -B complete all as specified and directed by Engineer-in-Charge.
S&F in repairs sink with drainage board made of Stainless Steel 1mm thick kitchen with plug washer and waste including bedding in cement mortar to dwarf wall including fixing contilever brackets connecting union to pipe over all size 915x460 mm bowl of size 410 x 330 x 160 mm complete all as specified and directed by Engineer-in-Charge.
Dismantaling boarding, any discription fixed in any position with nails complete all as specified and directed by Engineer-in-Charge.
M & L for prelaminated particle board both side with decorative choice laminations exterior grade 19mm thick in repair kichen cabinate complete all as specified and directed by Engineer-in-Charge.
S & F for tower bolt 100 mm of PTMT complete all as specified and directed by Engineer-in-Charge.
S & F for door handle D type 100 mm of PTMT complete all as specified and directed by Engineer-in-Charge.
S & F for Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed by Engineer-in-Charge.
S&F for 'Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in complete all as specified and directed by Engineer-in-Charge.
M&L for water proofing treatment for RCC sunken slab (not exceeding 45cm depth of sunken) as specified below complete all as specified and directed by Engineer-in-Charge. (a) 15mm plaster in cm 1:3 with WPC on raised vertical surface (b) cleaning the surface with wire brush / coir brush, removing lose material like dust particals, dirt etc. (c) Creating fillet covering of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and vertical surface (e) provision of glass fiber mesh of 2x2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) laying concrete 1:4:8 over the coating as per requirement (h) joining the sanitery pipes with the waterproofing tape having bridging ability of more then 1.5mm (j) filling the gap between the wall opening and sanitery pipe with non shrink cementatious grout (k) Complete the treatment to be carried out by authorised applicater of waterproofing manufacturer. Make ; Dr. Fixit / Fosroc / BASF / STP Note: (i) the treatment shall be carried out as per the manufacturer instruction and as directed by the Eng in Charge. (ii) The plan area of floor shall be considerd for payment. (iii) Cost of WPC @ 3% by wt of cement is included in the unit rate of item.
Providing 100mm thick cement concrete Type E-2, 1:5:10 (40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
S&F for Stainless steel plate rack of size 750mm x 600mm, made out of 1mm thick stainless steel of sheet of 1st quality complete all as specified and directed by Engineer-in-Charge.
S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified and directed by Engineer-in-Charge.
S & F in repairs vitrous china wash hand basin coloured top bowl type of size 380x380mm long screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore bib taps,chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down, secrewed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15mm bore stop cock one way fancy type, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Sink mixer with swinging spout(wall mounted model)Chromium plated brass with connection and nut complete all as specified and directed by Engineer-in-Charge.
S&F in repairs brass chromium plated wall mixer for mixing hot& cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC bathroom cabinet mirror 450 x 350 mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Swivel shower of any colour with Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of any colour for fixing with 15mm dia pipe. (Minimum weight 40 + 40gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge.
S & F for soap dish fixed as chromium plated brass complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F for PVC corner shelf with bracket complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing 15mm bore and connections complete all as specified and directed by Engineer-in-Charge.
Fixing only GI tubing any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required complete all as specified and directed by Engineer-in-Charge. Note : Serviceable galvanised tubes retrieved from respective items shall be laid under these items
S & F for 15mm bore medium grade GI tubing with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing 20mm bore and connections complete all as specified and directed by Engineer-in-Charge.
Fixing only GI tubing any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required complete all as specified and directed by Engineer-in-Charge. Note : Serviceable galvanised tubes retrieved from respective items shall be laid under these items
S & F for 20mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
S&F in repair for rotational moulded polythene three layered white colour water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 500 Litres complete all as specified and directed by Engineer-in-Charge.
M&L for Ball valves PTMT 20mm, with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe of following description :-.(Min. wt 20 mm -210 gms) complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fittings complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC socketed SWR pipe with rubber ring joints 110mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC socketed SWR pipe with rubber ring joints 75mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge.
S&F in repairs cast iron waste and vent pipe in any length with or without ear with cement joints laid in trenches or in floor 100mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repairs cast iron waste and vent pipe in any length with or without ear with cement joints laid in trenches or in floor 75mm dia complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S & F for Grating doom 125 mm dia with waste hole of PTMT ( Min wt 40 gm ) complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 15mm thick on fair faces of brick work in CM 1:4 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Providing & applying Rising damp proof coating system with single component ready to use damp-proof coating Roff Hydamp: 1.SURFACE PREPARATION:Thoroughly brush and clean all laitance,loose particles such as dirt,grease,mortar droppings,release agents,efflorescence,bird droppings etc. all large voids or hollow portions must be removed and replastered.Non-moving cracks having width upto 5 mm must be filled with polymer based crack filler. 2.APPLICATION: Apply the first coat of Hydamp with paintbrush directly on the prepared surfaces.Allow to dry for a minimum 2-3 hrs.Apply one part of Roff Hydamp and 2 parts of OPC white cement and make the putty,apply putty on the entire surface area.Allow it to dry for atleast 3-4 hours.Apply the final coat of Roff Hydamp on the entire surface complete all as specified and directed by Engineer-in-Charge.
M&L for three coat of white wash on ceiling including necessary preparation complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered and unplastered surfaces of wall by applying two coats of interior grade wall putty( 1mm thick of each coat) and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of oil bound distemper over one coat of cement primer including complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered surfaces of wall by complete removing old treatment and applying two coats of interior grade wall putty( 1mm thick of each coat) and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of oil bound distemper over one coat of cement primer including complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered and unplastered surfaces of wall by applying two coats of interior grade wall putty( 1mm thick of each coat) manually and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of weather coat emulsion over one coat of primer manually complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of Old plastered external surfaces of wall by complete removing old treatment and applying two coats of interior grade wall putty( 1mm thick of each coat) manually and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of weather coat emulsion over one coat of primer including all as specified by mechanical method and complete all as specified and directed by Engineer-in-Charge.
M&L for preperation of old wooden surface and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preperation of old steel surface and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M & L for providing two coats of synthetic enamel paint over new wooden surface including preparation of surface with primer complete all as specified and directed by Engineer-in-Charge.
M & L for providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
Hard core of broken bricks of gauge not exceeding 63mm, deposited,spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate)as in sub base complete all as specified and directed by Engineer-in-Charge.
M & L for Machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade over 25 mm thick layer of fine sand complete all as specified and directed by Engineer-in-Charge.
M&L for contineous brick edging with burnt clay brick work with sub class ‘B’ with width equal to width of brick laid dry on end vertically complete all as specified and directed by Engineer-in-Charge.
S&F for Floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
Excavation trenches n exc 1.50 wide and n exc 1.50 m depth for foundation etc in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading leveling, watering and well ramming in layers n exc 25 mm thick soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc 250 m and deposited where directed at a level not exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Providing cement concrete Type D-2, 1:4:8 (40 mm graded stone aggregate as in foundation, filling and mass concrete) complete all as specified and directed by Engineer-in-Charge.
S&F for cast iron bend 100mm bore dimenshing pieces or tappers ( large bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F for cast iron bend 75mm bore dimenshing pieces or tappers ( large bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for cast iron floor trap 75mm dia incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 75mm dia complete all as specified and directed by Engineer-in-Charge.
S & F for steel work in rectanguler/square trusses including special shaped washer etc complete using ERW or incl butt welded tubes confirming to IS 1161-1979 grade ST-240 with one coat of sink chromate primer paint incl preparation of surface complete all as specified and directed by Engineer-in-Charge.
S&F for 50mm thick PUF panel made of Puf insulation in core having density 40+2 Kg/Cum sandwiched betweeen two numbers of polyster coated galvalume steel sheet.these sheets shall be made out of 0.50mm thick (TCT) High tensile steel having min yield strength of 550 Mpa confirm to AZ 150 of AS-1397 wityh hot dip metalic coating of 55% ZN alloy having total coating mass of minimum 150 gms/sqm inclusive of bothside. the material shall be coated with polyster coating paint system of 20 micron over primer of 5 micron (exposed side) & alkyd back coat of 5 micron over primer coat of 5 microns.the material shall be supplied as per drawing (approved by GE),colour and as per instruction complete all as specified and directed by Engineer-in-Charge. Make : Jindal / Mectech
S&F for powder coated GI, E-grid suspended false ceiling grid system 600mmx600mm with main runner 39x29.7x0.8mm, cross tee 39x27.7x0.80mm, and wall angle 22.20x22.20x0.65mm, ceiling suspended with 4mm dia GI wire hanger fixed with steel dash fastener or frame purlin of the roof with butterfly clips, hold down clips etc. main runner, cross tee, wall angle, of MS galvanised (PPP COS) complete all as specified and directed by Engineer-in-Charge.
S&F for 7mm - 8 mm thick exposed metal frame celing with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmx600mm grid all as per manufacturer's instructions finish, fixed to aluminium/ CGI frame work with hold down clips in false ceiling complete all as specified.
M& L for Plain Pre painted gavalume zinc coating GI based corrugated steel sheet 0.50mm thick for ridges, hip, vally gutter, drips of an colour having tensile strength of 550 Mpa as in wall,fixed with self tapping screws complete all as specified.
M& L for Pre painted gavalume zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverings/cladding to wall,fixed with self tapping screws complete all as specified.
Shotcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mm average thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete all as specified.
S&F for Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt complete all as specified.
M & L for 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified.
M& L for PCC 1:2:4 type B1, using 20 mm graded agg.as in bed blocks ,coping, hold fast blocks etc. complete all as specified.
Sand filling under flooors or in foundation including and consolidation as as specified and directed at site complete all as specified and directed by Engineer-in-Charge
M & L for brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed by Engineer-in-Charge
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 4 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes complete all as specified and directed by Engineer-in-Charge Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Taking down carefully copper /aluminium point wiring (light ,fan ,socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and directed by Engineer-in-Charge
M & L for point wiring with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in including concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, for one light / bell / fan point controlled by one way switch 5 Amps complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 148 here-in-before but for One light point controlled by by one two way switches 5 Amps complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 148 here-in-before but for 3 pin socket outlet, 5 Amps on the same board with other switches with cable 1.5 Sqmm size complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 148 here-in-before but for one 3 pin socket outlet, 5 Amps on independent board with other switches with cable 1.5 Sqmm size complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete with 2.5 Sqmm (Nominal area) PVC insulated multistranded fire retardant low smoke unsheated and stranded copper conductor cable ISI marked in and including PVC concealed conduit medium quality and conduit fitting for 3 pin 15 amp multicore switch socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100V grade in Existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly with copper including provn of of 1.2 mm thick pressed steel sunken terminal boxes 60mm deep suitable lenth and painted with red oxide primer in place of unserviceable shunken box complete for housing switches, regulators, bell push etc, for one light / fan point controlled by one way piano switch 5 Amps complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 153 here-in-before but for one socket point 5 Amps on an independent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 153 here-in-before but for one socket point 5 Amps on same board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 153 here-in-before but for one light point wiring controlled by two, two way switches complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 153 here-in-before but for existing concealed conduit one 3 pin socket outlet, 15 Amps on independent board with other switches with cable 2.5 Sqmm size complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 153 here-in-before but for switch piano flush type single pole, one way 5 Amps complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 153 here-in-before but for 2 ways 5 Amps complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 153 here-in-before but for bell push complete all as specified and directed by Engineer-in-Charge.
S&F for switch piano, flush type single pole, one way 15 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete all as specified and directed by Engineer-in-Charge
M & L for celling rose 3 pin/pvc/ polycarbonate isolated body complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of FTL, LED type tube rod 1x18/20W, 230v, not less than 6000K(4') complete all as specified and directed by Engineer-in-Charge
M&L for Batten for LED tube light lighting fixture with extruded aluminium heat sink, envirironmental friedly energy efficient ready to use with 18/20 W LED 6000 (4') including electric connection with PCC copper flexible twin core cable, 1.0 Sqmm from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed by Engineer-in-Charge
Earthing complete with galvanised steel earth platge electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal round level) with edge of the plae not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and GI washers earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around bottom and top of earth plate as shown in electrical piate No. 3 of SSR Part-I and connecting to earthing test point and testing on completion including PCC 1:3:6 type C2 for earthing pit, GI light grade protection pipe of size 15mm dia, watering pipe 20mm bore medium grade, CI cover and frame necessary earth works and PCC work etc complete all as specified. Earth plate shall be surrounded by alternate layer of charcoal of coke and common salt 15cm thick alround the earth plate including bottom and top complete all as specified and directed by Engineer-in-Charge. Note: PCC chamber shall be constructed at least 1.5mtr away from the earth electrod and pipe for watering shall be slanting manner
S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways complete all as specified and directed by Engineer-in-Charge
S&F for MCB SPN 63 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge
S&F for MCB SP 6 to 40 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge
S & F for submain wiring with two single core cables PVC FRLS insulated unsheathed 6 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer-in-Charge Note:PVC cables two single core and one single core of sizes as mentioned will considered as one unit
S&F for pressure dia cast aluminium housing LED type street light fitting luminaries 15/18/20 Watts, not less than 6000K clear transperant acrylic cover with IP 66, gray colour and fixing to wall with 25 mm dia GI pipe bracket connected with suitable size of copper conductor complete all as specified and directed by Engineer-in-Charge
Taking down existing main control board and supply and fixing CRCA sheet metal board made out of 2.0mm thick and painting with 2 coats with synthetic enemel paint over a coat of red oxide primer including copper bus bar and fixed on/inside wall for fixing arrangement of existing electronic meter incl internal connection with suitable size of copper conductor wire, and accessories, locking arrangement with opening handle (size not less than of box 100cmx80cmx25cm and adequate depth for the following equipments,internal wiring and termination of external cables, lugs and glands and conduit as required) comprising of following complete all as specified and directed by Engineer-in-Charge (a) Incoming : MCCB 63 Amp, 4 Pole, 415 Amps, 25 KA - 01 No. (b) Copper Bus Bar 200 Amps for phase and neutral and earth bar (c) Out going MCB SPN 40 Amps - 04 Nos. (d) Taking down electric meter from existing distribution board and re-fixing only existing electronic meter single phase 15 amps to 40 Amps, 240 Volts on new distribution panel - 04 Nos.
S & F for GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in-Charge.
S&F for call bell ding-dong type, AC 230 Volts single pole complete all as specdied and directed by Engineer-in-Charge.
S&F for batton holder insulated body with back plate inluding 9 watts LED lamp complete all as specified and direcrted by Engineer-in-Charge. --------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,93,179.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 43(R) & 44(R) (Schedule of Credit) of Tender document
SUDESH ENTREPRISES
MANCHANDA CONSTRUCTION CO
POOJA CONSTRUCTION COMPANY
RANDHIR AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .