| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.9 L+₹68,397.46 (5.17%)Rejected-Finance HOLDING NO 198 178 WARD NO 23 NEAR SHAKTIBHAVAN INDA KHARAGPUR WEST BENGAL 721 305 | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721305 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹14.2 L+₹1.0 L (7.59%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹15.2 L+₹2.0 L (15.1%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹15.5 L+₹2.3 L (17.0%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
7 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR AND MAINTENANCE OF LT DISTRIBUTION SYSTEM WITH ALLIED WORKS AT AIR FORCE STATION SALUA UNDER GE (AF) KALAIKUNDA
2021_MES_452129_1
8674/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Kalaikunda
₹40,000
Yes
15 Jul 2021
17 Jun 2021
9 Jul 2021
17 Jun 2021
7 Jul 2021
30 Jun 2021
60 days
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
Disconnecting and Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of any size complete all as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 300 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
All as per item No 9 here-in-before but of size 185 Sqmm 3.5 complete all as specified and as directed.
All as per item No 9 here-in-before but of size 120 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 9 here-in-before but of size 95 Sqmm 3.5 Core. complete all as specified and as directed.
All as per item No 9 here-in-before but of size 70 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 9 here-in-before but of size 50 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 9 here-in-before but of size 35 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 9 here-in-before but of size 25 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 9 here-in-before but of size 16 Sqmm 4 core complete all as specified and as directed.
All as per item No 9 here-in-before but of size 10 Sqmm 2 core complete all as specified and as directed.
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 240 sq. mm to 300 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0144 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
All as per item No 19 here-in-before but of size of size 185 sq. mm to 300 sq. mm, complete all as specified and directed.
All as per item No 19 here-in-before but of size of size 95 sq. mm to 120 sq. mm, complete all as specified and directed.[Kit No.EPKJ 0137 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
All as per item No 19 here-in-before but of size of size 50sq. mm to 70 sq. mm, complete all as specified and directed.
Material and labour for 40 mm dia galvanized iron tube Medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
All as per item Serial No 23 here-in-before but for 50 mm dia pipe complete all as specified and directed.
All as per item Serial No 23 here-in-before but for 80 mm dia pipe complete all as specified and directed.
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 40 to 50 mm bore, galvanised steel tubing,complete all as specified and directed.
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 80 to 100 mm bore, galvanised steel tubing,complete all as specified and directed.
S&F in replacement cable PVC insulated heavy duty 1100 volts grade aluminium stranded conductor of size 10 Sqmm twin core, flat, served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangars not more than 1.0 mtr apart incl 4.0mm dia suspension wire complete all as specified and directed.
Supply, installation, commissioning and testing of LT Bus Bar Feeder Piller Box type factory made CPRI approved weather, dust & vermin proof Feeder Piller Box outdoor type having provision of double door openings with rubber beadings cubical type of size 0.6x0.6x0.15 Mtr as directed by the manufacturer, made out of 3.15 mm CRCA sheet compartmentalized with rubber beadings, angle iron 25 x 25 x 5 mm shall be used for making legs/ frame, duly including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces, including provn of Aluminium Busbar and 16 Amps SPN and suitable insulators and cable gland for terminal connections of cables and fixed with suitable size nuts and botls of size as directed including provn of PCC Platform of suitable size with PCC 1:2:4 as per manufacturer,s all as directed by the Engineer-in-charge. Note: The schematic diag of LT Panels shall be approved by GE before procurement.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 63 Amps and 10 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 16 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In,complete all as specified and directed.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 125 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed. [Cat No. CM90642OOLO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 160 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In,complete all as specified and directed. [Cat No. CM90642OOMO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 200 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed. [Cat No. CM90642OONO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
All as per Item No 34 here-in-before but of capacity 250 Amps, 36 KA breaking capacity complete all as directed. [Cat No. CM92109OOP1OG of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
All as per Item No 34 here-in-before but of capacity 400 Amps, 36 KA breaking capacity complete all as directed. [Cat No. CM94106OOS1OG of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs, On Load Change Over Switch in sheet steel enclosure, Four Pole, Current Rating 63 Amps, conforming to IS 13947 (Part 3)-1993; IEC: 60947-3, complete all as specified and directed. [Cat No. CO10630OSOO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs, On Load Change Over Switch in sheet steel enclosure, Four Pole, Current Rating 100 Amps, conforming to IS 13947 (Part 3)-1993; IEC: 60947-3, complete all as specified and directed. [Cat No.CO11000OSOO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
BUILDCON
VICKY ENTERPRISE
NAVYUG CONSTRUCTION
Neha Enterprise
Ultimate Solution Company
SENCO
shanti enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .