Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.2 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹35.0 L+₹8.4 L (31.4%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹36.5 L+₹9.9 L (37.0%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹36.9 L+₹10.3 L (38.6%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹39.9 L+₹13.3 L (49.9%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PALAM
GE (AF) PALAM DELHI CANTT-10
REPAIR / MAINTENANCE LT UG CABLES, LT OVERHEAD LINES, LT SWITCHGEARS AND CONNECTED ITEMS IN TECHNICAL AREA AND CAMP AREA AT AF STN PALAM UNDER GE (AF) PALAM, DELHI CANTT - 10
2024_MES_656348_1
8024/A/T-20/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM
₹80,000
Yes
31 Aug 2024
28 May 2024
2 Jul 2024
28 May 2024
25 Jun 2024
11 Jun 2024
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid, tested complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) complete all as specified and as directed.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed.
Laying old serviceable bricks in trenches for cable protection of burnt bricks complete laid dry flat complete all as specified and as directed. Note:- Old bricks are retrieved under item 01 of Sch ‘A’.
Taking out old unserviceable LT under ground cable any type from trenches, pipes & poles complete all as specified and as directed.
Relaying of old serviceable LT cables complete all as specified and as directed. Note:- Old LT Cable retrieved from item No. 7.00 above.
Supply and laying in replacement of XLPE LT 1100 Volt Grade, armoured under ground cable of size 10 Sqmm 2 core with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified and as directed.
Description all as per srl item No 9.00 above but 16 Sqmm 2 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 16 Sqmm 4 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 25 Sqmm 4 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 35 Sqmm 3.5 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 50 Sqmm 3.5 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 70 Sqmm 3.5 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 95 Sqmm 3.5 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 120 Sqmm 3.5 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 150 Sqmm 3.5 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 185 Sqmm 3.5 core complele all as specified and as directed.
Description all as per srl item No 9.00 above but 240 Sqmm 3.5 core complele all as specified and as directed. Notes for ser item No. 8.00 to 20.00:- Excavation, earth work and protection of cable shall be measured and paid seperately.
Supply & jointing heat shrinkable straight through joint kit suitable for LT 1100 Volt grade XLPE cable of size 400/500 Sqmm 3.5 core complete with treating of cable to make ready for jointing etc complete all as specified and as directed.
Description all as per item No. 21.00 here in before but suitable for cable size 240-300 sq mm complete all as specified and as directed.
Description all as per item No. 21.00 here in before but suitable for cable size 150-185 sq mm complete all as specified and as directed.
Description all as per item No. 21.00 here in before but suitable for cable size 70-120 sq mm complete all as specified and as directed.
Description all as per Srl item No. 21.00 here in before but suitable for cable size 25-50 sq mm complete all as specified and as directed.
M&L for galvanised steel tube, light grade with all fitting complete laid in trenches/ road / Path/ on pole of 80 mm bore complete all as specified and as directed.
Description all as per srl item No 26.00 above but GI pipe of 100mm bore complete all as specified and directed.
Description all as per srl item No 26.00 above but GI pipe of 150mm bore complete all as specified and directed.
Description all as per srl item No 26.00 above but GI pipe of 50mm bore complete all as specified and directed.
Description all as per srl item No 26.00 above but GI pipe of 40mm bore complete all as specified and directed.
Dismantling concrete poles/steel tubular poles,struts of any size complete all as specified and as directed by Engineer-in-Charge.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (09 Mtr long) with and including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and as directed. Note:- Excavation, earth work and PCC shall be measured and paid separately under relevant items.
M&L in replacement of lugs/thimbles at termination of LT cable by cutting the end portion and removing insulation and fixing new aluminium lugs /thimble properly with crimbing tool of size 185 -400 sqmm complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No. 33.00 here in before but for cable size 50-150 sqmm complete all as specified and directed by Engr-in-Charge.
Description all as per srl item No. 33.00 here in before but for cable size upto 35 sq mm complete all as specified and directed by Engr-in-Charge.
Cutting and trimming of tree branches to clear street light lines in the area of the street light sorrounding area (including repairing and jointing of street light connection damaged during cutting of tree) and removal of the trimmed branches of trees and depositing the same in MCD waste bins inside the campus complete all as specified and directed by Engr-in-charge.
M&L for preparing existing old surface of steel tubular poles including cross arms and clamp of any type 09 Mtr long and painting one coat of aluminium paint on the surface of steel tubular pole, with white /blue 30 cm wide strip upto the height of 1.5 mtr above ground level and marking the pole No in 4” dia yellow paint complete all as specified and as directed.
M&L for painting to PCC pole with cross arms and clamp of any type and any size with a coat of synthetic enamel paint with white /blue 30 cm wide strip upto the height of 1.5 mtr above ground level and marking the pole No in 4” dia yellow paint circle complete all as specified and as directed.
M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 15 Mtrs long with and including laying HDPE pipe of 150mm dia complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCCB 400 Amps 4 pole 50 kA 415 Volts 50 Hz with thermal adjustable magnetic settings, necessary conection including taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed.
Description all as per srl item No. 40.00 here in before but 320/350 Amps 36 kA complete all as specified and directed by Engineer-in-Charge.
Description all as per srl item No. 40.00 here in before but 250 Amps 36 kA complete all as specified and as directed by Engineer-in-Charge.
Description all as per srl item No. 40.00 here in before but 200 Amps 36 kA complete all as specified and as directed by Engineer-in-Charge.
Description all as per srl item No. 40.00 here in before but 160 Amps 36 kA complete all as specified and as directed by Engineer-in-Charge.
Description all as per srl item No. 40.00 here in before but 125 Amps 16 kA complete all as specified and as directed by Engineer-in-Charge.
Description all as per srl item No. 40.00 here in before but 100 Amps 16 kA complete all as specified and as directed by Engineer-in-Charge.
Description all as per srl item No. 40.00 here in before but 63 Amps 16 kA complete all as specified and as directed by Engineer-in-Charge.
M&L for defect rectification LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additional excavation in normal alluvial strata required for exposing the cable fault, removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sqmm 3.5 core. The fault locating equipments shall be brought to site within the hours of instructions from Engr-in-Charge. Note :- (Cost for excavation, earthwork, refilling etc shall be included in the quoted rate by the contractor).
Supply and fixing vertical type load line distribution board, double door, 8 way, AC 3 Phase, 415 volts ,TPN, bus bar 200 Amps, rating and earth bus & din rail suitable for MCCB, IP 43, metal door complete all as specified and as directed by Engineer -in-charge.
Supply and fixing MCCB, 3 pole,125 Amp,10kA complete all as specified and as directed.
Supply and fixing replacement MCB, SPN, 240V, 10 kA, 'B' curve, single poles and current carrying capacity 32 Amp in the eisting MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in replacement MCB 240V, 10kA 'C' curve, SP, 5-32A in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of MCB, TP 25 to 63 Amp ,10kA, 415V 'B' curve MCB complete with connection testing and commissioning complete all as specified and as directed by Engr-in-Charge.
Supply only Power contactor 3 phase, MNX 650 series complete all as specified and directed. Make:- L&T / Seimens / Havells
Supply only Power contactor 3 phase, 32A/40A MNX A2 series complete all as specified and as directed. Make:- L&T / Seimens / Havells
Supply and fixing in replacement of outdoor type cubical Feeder pillar box (1000x800x500)mm size suitable for 3 phase, 4 wire, 415 Volt, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof IP 65 class protection and the panel should have 800 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame (40mmx40mmx6mm) duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and front opening type, with aprons for cable entry, with double door shutter and locking arrangement with MCCB 400 Amp 4 pole 36 kA as incoming including terminating the existing incoming and outgoing cables etc including PCC foundation in (1:2:4) type B-1 complete all as specified and as directed by Engineer -in-charge.
Supply and fixing in replacement of outdoor type cubical Feeder pillar box (750mmx500mmx450mm) size suitable for 3 phase, 4 wire, 415Volt, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof IP 65 class protection and the panel should have 400 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame (40mmx40mmx6mm) duly painted with two coats of synthetic enamel paint over a coat of zinc chrome primer and front opening type, with aprons for cable entry, with double door shutter and locking arrangement with MCCB 250 Amp 4 pole 36 kA as incoming including terminating the existing incoming and outgoing cables etc including PCC foundation in (1:2:4) type B-1 complete all as specified and as directed by Engineer -in-charge.
Supply and fixing in replacement of outdoor type cubical Feeder pillar box (600x500)mm x 450mm size suitable for 3 phase, 4 wire, 415Volt, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof IP 65 class protection and the panel should have 300 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame (40mmx40mmx6mm) angles duly painted with two coats of synthetic enamel paint over a coat of zinc chrome primer and front opening type, with aprons for cable entry, with double door shutter and locking arrangement with MCCB 160 Amp 4 pole 25/36 kA as incoming including terminating the existing incoming and outgoing cables etc including PCC foundation in (1:2:4) type B-1 complete all as specified and as directed by Engineer -in-charge.
M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
M&L for earthing in replacement of with galvanized mild steel earth plate electrode (60cm x 60cm) x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip (25x4)mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) with fair finish internal surface of concrete, chamber shall be given 15mm thick plaster in CM (1:4), funnel with wire gauge mesh, 80 mm thick RCC pit cover (320mm x 320mm) of RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & as directed by Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode (60cm x 60cm)mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I of 2009 and including excavation & earth work in any type of soil, disposal of soil, providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix (1:3:6) type C-1 with 40 mm thick RCC (1:2:4) type B-1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and as directed by Engr-in-Charge.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundtion of PCC poles/struts complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundtion of pole/stay assembly etc including necessary use and waste of form work complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping around poles, including necessary use and waste of form work, finishing surface even and smooth without using extra cement complete all as specified and as directed.
M&L for welding hinges to existing panel board with existing shutters and fixing to panel board complete all as specified and as directed.
M&L for replacement of shutter of with 3 mm thick CRCA sheet as per existing size to match with the existing panel and welding hinges and fixing complete all as specified and as directed.
M&L for painting of existing LT panel board with spray gun with syynthetic enamel paint to match with the existing colour/ surface complete all as specified and as directed.
Supply and fixing in replacement glands for cable upto 240 Sqmm size double compression type complete including removing and refixing cables from LT panel for fixing the glands complete all as specified and as directed.
S&F in replacement of analog type time switch 3P module, DIN 24 hours programmable every 30 minutes of current capacity 16 Amps with one change over including connecting to existing power contactor complete all as specified and as directed. Make:- Havells/ IndoAsian/HPL
S&F in replacement of digital type time switch 3P module, DIN 24 hours programmable every 1 minutes with 28 memory location of current capacity 16 Amps with one change over including connecting to existing power contactor complete all as specified and as directed. Make:- Havells/ IndoAsian/ L&T.
S&F in replacement of RYB indicator LED type capacity complete campus complete all as specified and as directed. Make:-HPL/ Indo asian/ L&T
M&L in replacement of PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 16 Sqmm 2 core complete and all as specified and as directed.
Description all as per srl item No. 73.00 here in before but cable of size 10 Sqmm 2 core complete and all as specified and as directed.
M&L in replacement Junction box outdoor type, 3 phase 415 Volts of size (350x250x150)mm made out of hot press moulded SMC front openable hinged type including 4 Nos. Al bus bars mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmps, nuts, bolts etc of size (25 x 4) mm duly painted with two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
M&L in replacement Junction box outdoor type, single phase 230 Volts of size (300x200x105)mm made out of hot press moulded SMC front openable hinged type including 2 Nos. Al bus bar mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmp, nuts, bolts etc of size (25 x 4) mm duly painted with two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
Supply and fixing in replacement of ACB 1000 Amp, 4 Pole, LT 415 V, 65 kA breaking capacity with Electrical draw out, Micro processor release (IPR2 04 Pole) with auxiliary switch 6NO+6NC, Main CTs, safety shutters, 36 way auxiliary isolating contacts and horizontal terminal type complete including disconnecting and taking down the existing unserviceable ACB any type and making necessary electrical connections including making necessary fixing arrangements in the existing panel complete all as specified and directed.
Supply and fixing in replacement of ACB 800 Amp, 4 Pole, LT 415 V, 65 kA breaking capacity with electrical draw out, Micro processor release (IPR2 04 Pole) with auxiliary switch 6NO+6NC, main CTs, safety shutters, 36 way auxiliary isolating contacts and horizontal terminal type complete including disconnecting and taking down the existing unserviceable ACB any type and making necessary electrical connections including making necessary fixing arrangements in the existing panel complete all as specified and as directed.
M&L for PCC M-15 (nominal mix), type B-1 (using 20mm graded crushed stone aggregate) as in pole coping after demolishing the damaged coping complete all as specified and as directed.
M&L for preparation of old painted for chain link/barbed wire fencing/gate/angle iron/PCC post of sub station (outer exposed surface). Painting shall be started from above ground level including MS channel / angle iron and GI bracket/clamps with bolts, nuts and applying two coats of aluminium paint / snowcem including writing substation details with black colour of existing size letters complete all as specified and as directed.
Cutting existing road / foot path / bituminous macadam and PCC on foot path for laying protection pipe for cable and making good the disturbed surfaces of road/ foot path to match with the existing surface complete and all as specified and as directed. Note:- PCC shall be measured and paid seperately.
Supply and spread stone agregate 45mm size for transformer yard/ HT 2 pole/4 pole structure after preparing the sorrounding by brick work and removing the vegetation and making brick work and necessary surface excavation and spreading of layer of sand complete all as specified and as directed. Note:- (i) Earth work and brick work shall be deemed to be included in quoted rate. (ii) sand shall be measured and paid seperately.
Repairs to the existing earthing complete by replacing the US GI strip, bolt, nut, check nut and washer, earthing test point all as specified including testing on completion including making PCC chambers, RCC cover, GI funnel for watering, GI funnel, earth strip protection pipe, including 10 kgs of salt and watering, testing of earth result by megger and submitting the report etc all as specified and as directed including writing and painting of earthing details complete all as sdpecified and as directed. Note:- (i) Required excavation and demolition shall be deemed to be included in unit rate. (ii) Earth strip and protection pipe and watering pipe shall be measured an paid seperately under respective items of BOQ.
S&F in repair GI strip (32 x 6) mm as eath continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing after removing the unserviceable strip complete and all as specified and as directed.
S&F in repair GI strip (25 x 4)mm as eath continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc after removing the unserviceable strip complete and all as specified and as directed.
S&F in repair aluminium strip (25 x 3)mm as eath continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc after removing the unserviceable strip complete and all as specified and as directed.
M&L for earth marking plate made out of mild steel plate 3 mm thick of size (200mm x100mm) fixed on angle iron (25x25x 6)mm 400mm long grounded in PCC (1:3:6) type C1 near earth pit and steel surfaces shall be treated with two coats of synthetic enamel paint over a coat of zinc chrome primer. Necessary marking of earth No., equipment connected, tested on date, results in ohms etc shall be embossed complete all as specified and as directed.
M&L for danger notice plate of 1.6mm thick mild sheet steel vitreous enamelled white with letters figures and conventional skull and in bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT/HT 25X20cm size complete all as specified and as directed.
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium bus bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and out going controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT panel is deemed to be included in the quoted rate ) INCOMING (i) MCCB 400Amp, 4 pole, 50kA with adjustable thermal & adjustable magnetic setting - 1 No (ii) Digital Multi functional meter VAFPP (voltage, current, frequency, power factor) - 1 No. (iii) Phase indicator lamp (LED type) - 1 Set. (set of three) OUT GOING:- (i) MCCB 125A , 4 P, 25 KA with adjustable thermal & fixed magnetic setting – 02 Nos (ii) MCCB 100A, 4 P, 25 KA with adjustable thermal & fixed magnetic setting - 04 Nos (iii) Digital type time switch 16 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory with suitable MCB control - 01 No.
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and out going controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT panel is deemed to be included in the quoted rate ) INCOMING (i) MCCB 250A 4 P, 36KA with adjustable thermal & adjustable magnetic setting - 1 No (ii) Digital Multi functional meter VAFPP (voltage, current, frequency, power factor) - 1 No. (iii) Phase indicator lamp (LED type) - 1 Set. (set of three) OUT GOING:- (i) MCCB 100A, 4 P, 25 KA with adjustable thermal & fixed magnetic setting – 04 Nos (ii) MCCB 63A, 4 P, 16 KA with adjustable thermal & fixed magnetic setting -01 Nos (iii) Digital type time switch 16 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory with suitable MCB control- 01 No.
Supply and fixing of Ruby clear post top 25W LED, 5700K new generation energy saving & environmental friendly, long life versatile aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs light source IP 65 complete all as specified and as directed.
S&F in repalacement of street light bracket made out of 40 mm dia light grade GI pipe bend to shape 1.2 m long with 02 Nos clamp made out of (25 x 6)mm GI strip including drilling holes bending welding and made to clamp on building/ concrete/ rail/ tubular pole complete all as specified and as directed.
S&F in repair MCB TPN 32 Amp to 40 Amp 415V complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting of 90 Watt, 5700K complete including all fixing accessories complete made up of pressure die cast aluminium housing with high power LED as lighting source and lens with heat resistant toughened glass & IP 66 protection with 10 KV built-in surge protection device complete complete with driver and all accessories fixed on and including GI bracket of sufficient length and size with all nuts, bolts, washers etc duly connection with & including three core flexible copper cable including taking down the existing light fittings complete all as specified and as directed by Engr-in-Charge.
Dismantling posts or struts (wood steel or RCC) any section including taking out embeded portion of concrete and making good disturbed in ground complete all as specified and as directed.
Dismantling old chain link/barbed fencing of any size or mesh complete all as specified and as directed.
Dismanlting wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for PCC (1:2:4) type B2 (using 40mm graded stone aggregates) as in posts and pillars complete all as specified and as directed.
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and ountersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290 Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed.
M&L for preparation of new surfaces of steel and iron surfaces of any description over 10cm in width or grith not otherwise described for and applyying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
Supply and fixing chain link fencing 4mm dia galvanised steel wire (150x100)mm mesh, including provision of binding wire complete all as specified and as directed.
M/s Prakash Enterprises
H.B. Traders
Commercial Traders
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .