Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.3 Cr+₹4.3 L (3.41%)Rejected-Finance FLAT NO 164 SHAKTISHIKHA GANDHI NAGAR SIGRA VARANASI UP 221003 | VARANASI | VARANASI | UP | 221003 | ₹1.3 Cr+₹4.3 L (3.41%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹1.4 Cr+₹12.2 L (9.57%)Rejected-Finance | ₹1.4 Cr+₹12.2 L (9.57%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹1.4 Cr+₹14.6 L (11.5%)Rejected-Finance | ₹1.4 Cr+₹14.6 L (11.5%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹1.4 Cr+₹17.0 L (13.3%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | ₹1.4 Cr+₹17.0 L (13.3%) | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Bharat Sales Corporation L6 | SATISH AND CO L7 | Amit Engineering L3 | Panwar Construction Co. L9 | GEPS PROJECTS L11 | Diamond Electric Co. L5 | Sanjai sales and services L1 | M K Engineers and Contractors L8 | Ashirwad Contractor and Supplier L10 | LUMOS INFRA PVT LTD L4 | Ray Enterprises L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying , installation, testing and commissioning of 12 KV, 630 Amps having short circuit capacity 21kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 2-way comprising of 01 Nos motorized operated Load Break Switch and 01 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled (SF6), robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank with min. thickness 3+0.5 mm, IP 67 Degree of Protection , internal-arc classified 21kA/1sec for cable box and tank both, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site. | 6 | Each Job | 6,00,000 ₹36,00,000 | 5,99,000 ₹35,94,000 | 5,40,000 ₹32,40,000 | 5,75,000 ₹34,50,000 | 6,15,000 ₹36,90,000 | 6,00,000 ₹36,00,000 | 4,95,000 ₹29,70,000 Lowest | 6,39,900 ₹38,39,400 | 6,50,000 ₹39,00,000 | 5,26,500 ₹31,59,000 | 5,40,000 ₹32,40,000 |
| 1.01(A) 01 Nos. Incoming Load Break Switch module each consisting of following accessories :- (i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 12KV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21kA/3-sec, Making Capacity - 50kAp -01 No (iii) Auxiliary contacts - 1NO + 1NC-01 No (iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 | ||||||||||||||
| 1.02(vi) Right angle boots (push on type)-Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No | ||||||||||||||
| 1.03(B) 01 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 12kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp-01 No (iii) Aux. contacts - 1NO+1NC-01 No (iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 | ||||||||||||||
| 1.04(vi) Right angle boots (push on type)-Each set of 3 (vii) 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol-01 No (viii) Associated ring-core cast-resin insulated CTs 50/1 Amp , 2.5 VA, 5P10 for protection - Each Set of 3 (ix) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (x) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (xi) Push button for breaker trip (xii) Shunt trip coil 24V DC - 01 (xiii) ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. (xiv) Emergency Trip Push Button - 01. | ||||||||||||||
| 1.05(xv) Vacuum circuit breaker with high mechanical endurance of 10000 operations (M2 Class) (xvi) To ensure reliablility of operation Vacuum interrupter shall be of same make as Ring Main Unit. (C) Additional equipment deliverd separately or mounted seperately :- (i) Operationg Handle for Manual Isolator/Disconnector/Earthing Operation-02 Nos (ii) Standard Manometer -01 No (iii) Operation and Maintenance Manual -01 No (iv) Installation & Commissioning Manual -01 No (v) Cable clamping provision (standard) -01No Note:- (i) Necessay interclocking arrangement shall be provided for safety and operations (ii) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. Any claims towards internal arc compliance, number of mechanical/electrical/short-circuit operations, gas-leakage rates etc. shall not be accepted unless proven via type-test reports of model being offered. | ||||||||||||||
| 1.06(iii) Cost of construction of foundation including construction material, necessary earth work and excavaton as per manufacturer design for RMU complete all as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate. (iv) The height of foundation shall not be less than 60 cm and necessary foot step to be provided for operation of RMU without any extra cost | ||||||||||||||
| 2.00 | Supplying , installation, testing and commissioning of 12 KV, 630 Amps having short circuit capacity 21kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 3-way comprising of 01 Nos motorized operated Load Break Switch and 02 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled (SF6), robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank with min. thickness 3+0.5 mm, IP 67 Degree of Protection , internal-arc classified 21kA/1sec for cable box and tank both, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site. | 9 | Each Job | 9,08,800 ₹81,79,200 | 9,10,000 ₹81,90,000 | 8,80,000 ₹79,20,000 | 9,35,000 ₹84,15,000 | 8,82,000 ₹79,38,000 | 8,70,000 ₹78,30,000 | 7,90,000 ₹71,10,000 | 9,39,335 ₹84,54,015 | 9,10,000 ₹81,90,000 | 8,41,500 ₹75,73,500 | 7,82,000 ₹70,38,000 Lowest |
| 2.01(A) 01 Nos. Incoming Load Break Switch module each consisting of following accessories :- (i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 12KV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21kA/3-sec, Making Capacity - 50kAp -01 No (iii) Auxiliary contacts - 1NO + 1NC-01 No (iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 (vi) Right angle boots (push on type)-Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set | ||||||||||||||
| 2.02(ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No (B) 02 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 12kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp-01 No (iii) Aux. contacts - 1NO+1NC-01 No (iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 | ||||||||||||||
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
2 Mar 2026, 6:00 pmClosed
AGE (I) Ayodhya Cantt
Asst Garrison Engineer (I), Military Engineer Services, Ayodhya Cantt PIN-224001
SPECIAL REPAIR/ REPLACEMENT OF GOD/ AIR BREAK SWITCH WITH LOAD BREAK SWITCH (LBS) AND RMU ALONG WITH CERTAIN ALLIED WORKS UNDER AGE (I) AYODHYA
2026_MES_750808_1
8400/164/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Ayodhya Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Ayodhya
₹2.2 L
Yes
14 Jul 2026
31 Jan 2026
4 Mar 2026
31 Jan 2026
2 Mar 2026
23 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , installation, testing and commissioning of 12 KV, 630 Amps having short circuit capacity 21kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 2-way comprising of 01 Nos motorized operated Load Break Switch and 01 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled (SF6), robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank with min. thickness 3+0.5 mm, IP 67 Degree of Protection , internal-arc classified 21kA/1sec for cable box and tank both, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site. | 6 | Each Job | - | - |
| 1.01 | (A) 01 Nos. Incoming Load Break Switch module each consisting of following accessories :-
(i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch.
(ii) 12KV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21kA/3-sec, Making Capacity - 50kAp -01 No
(iii) Auxiliary contacts - 1NO + 1NC-01 No
(iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No
(v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 | - | - | - | - |
| 1.02 | (vi) Right angle boots (push on type)-Each Set of 03
(vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No
(viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set
(ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No
(x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No | - | - | - | - |
| 1.03 | (B) 01 Nos. Outgoing VCB module each consisting of following accessories :-
(i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function.
(ii) 12kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp-01 No
(iii) Aux. contacts - 1NO+1NC-01 No
(iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No
(v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 | - | - | - | - |
| 1.04 | (vi) Right angle boots (push on type)-Each set of 3
(vii) 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol-01 No
(viii) Associated ring-core cast-resin insulated CTs 50/1 Amp , 2.5 VA, 5P10 for protection - Each Set of 3
(ix) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No
(x) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No
(xi) Push button for breaker trip
(xii) Shunt trip coil 24V DC - 01
(xiii) ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01.
(xiv) Emergency Trip Push Button - 01. | - | - | - | - |
| 1.05 | (xv) Vacuum circuit breaker with high mechanical endurance of 10000 operations (M2 Class)
(xvi) To ensure reliablility of operation Vacuum interrupter shall be of same make as Ring Main Unit.
(C) Additional equipment deliverd separately or mounted seperately :-
(i) Operationg Handle for Manual Isolator/Disconnector/Earthing Operation-02 Nos
(ii) Standard Manometer -01 No
(iii) Operation and Maintenance Manual -01 No
(iv) Installation & Commissioning Manual -01 No
(v) Cable clamping provision (standard) -01No
Note:-
(i) Necessay interclocking arrangement shall be provided for safety and operations
(ii) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. Any claims towards internal arc compliance, number of mechanical/electrical/short-circuit operations, gas-leakage rates etc. shall not be accepted unless proven via type-test reports of model being offered. | - | - | - | - |
| 1.06 | (iii) Cost of construction of foundation including construction material, necessary earth work and excavaton as per manufacturer design for RMU complete all as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate. | - | - | - | - |
| 2 | Supplying , installation, testing and commissioning of 12 KV, 630 Amps having short circuit capacity 21kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 3-way comprising of 01 Nos motorized operated Load Break Switch and 02 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled (SF6), robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank with min. thickness 3+0.5 mm, IP 67 Degree of Protection , internal-arc classified 21kA/1sec for cable box and tank both, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site. | 9 | Each Job | - | - |
| 2.01 | (A) 01 Nos. Incoming Load Break Switch module each consisting of following accessories :-
(i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch.
(ii) 12KV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21kA/3-sec, Making Capacity - 50kAp -01 No
(iii) Auxiliary contacts - 1NO + 1NC-01 No
(iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No
(v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 (vi) Right angle boots (push on type)-Each Set of 03
(vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No
(viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set | - | - | - | - |
| 2.02 | (ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No
(x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No
(B) 02 Nos. Outgoing VCB module each consisting of following accessories :-
(i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function.
(ii) 12kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp-01 No
(iii) Aux. contacts - 1NO+1NC-01 No
(iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No
(v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 | - | - | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
TENDERDOCS.pdf
Tender Documents • 0.89 MB
BOQ_840905.xls
BOQ • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .