GE UTILITY BATHINDA
REPAIR/MAINT/REPLACEMENT OF LT NETWORK PANEL AND CONNECTED ACCESSORIES AT SOUTH MD ACCN UNDER GE(U) BATAINDA MIL STN.
2024_MES_676607_1
8830/2024-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER UTILITY BATHINDA
Class D cat b i
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER UTILITY BATHINDA
₹99,300
Yes
30 Dec 2024
25 Sept 2024
4 Nov 2024
25 Sept 2024
2 Nov 2024
18 Oct 2024
Amount
SCHEDULE 'A' PART- I (MATERIAL & LABOUR )
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Excavating in trencehes, n exc 1.5 m wide and exc m in depth but not exe 3 m in depth for foundation, etc or for laying of cables/poles, etc n exc 10 Sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil complete all as specified and directed
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for local sand cushioning, with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR-Part-1 before laying of cable and 150mm thick after laying of cable and punned down to 180mm after laying complete all as specified and directed by Engineer-in-Charge. (Note:- Punned thickness shall be considered for payment purpose.)
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata & relaxing taken out cable complete all as specified and directed.
M&L PCC (1:2:4) type C1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary Steel form work and finishing the surfaces fair in forms complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete for repair of existing structure of transformers/panels/poles etc complete all as specified.
M&L in replacement of heat shrink insulation tubes for all the bus bars of Lt Panels and maintaining the RYB sequence in the system complete all as specified and as directed
M & L in replacement of old unserviceable earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply,fixing,commissioning and testing ACSR conductor of any size on existing LT pole including copper binding wire or aluminium tab, complete all as specified and directed by Engineer-In- Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Un binding from old insulators and taking down old unservicable insulators and re–stretching only existing ACSR of any size on LT poles including binding the ACSR with new insulators with and including aluminium binding wire 2mm dia complete all as specified and as directed by Engineer-in-charge. Note :- The rate of aluminium binding wire 2mm dia is included in this item and nothing shall be paid extra on this account.2 New insulators shall be measured and paid seperately under respective item of this scheule of works
Cutting / trimming of tree branches upto 1.50 metre distance on each side and 3.00mtr distance on both sides of LT over head lines including collection and removal from road complete all as directed by Engineer-in-charge. Note :-For measurement and payment purpose each span shall be considered as 40.00 mtr. Span.If the length of span is less than 40.00mtr measurment and payment shall be considered proportionally. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in replacement for Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engr-in-Charge Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in replacement for shackle type porcelain, vitreous, white, brown or green insulator of size 75mm height, 90mm dia for working pressure 1100 volts including galvanized mild steel strips 31mm x 3 mm, washer, insulator bolts and nuts, dia of bolt 12mm complete all as specified and as directed by Engineer-in-charge.Note:- The rate of galvanized mild steel strips 31mm x 3 mm, washer, insulator bolts and nuts, dia of bolt 12mm is included in this item and nothing shall be paid extra. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and laying or fixing in replacement GI tubing light grade of following sizes for cable protection including fitting complete with flat iron clamps size of flat iron 25mm x 4mm or suitable size, nuts, bolts & washers complete fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench all as specified and directed by Engr-in charge :- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any finincial benefits complete all as specified by Engineer in Charge and GE.
All as per Item above but for GI pipe of 40 mm bore light grade.
All as per Item item above but for GI pipe of 80 mm bore light grade.
Supply and fixing in repair PVC separator suitable for 3/4 way conductor complete all as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any finincial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in repair PVC separator suitable for 5/6 way conductor complete all as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any finincial benefits complete all as specified by Engineer in Charge and GE. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Cleaning and preparation of old painted surface of LT PCC Pole / street light Pole/Steel tubular poles complee with cross Arms and base up to 1.50 mtr height from top of PCC foundation block, making alternative black and white strips VE waterproof high density reflective self adhesive strips on pole ( each strip 30cm hight ) and writing pole nos. including applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and as directed by Engineer-in-Charge.
Opening / Disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. Taking out the length of cable to be required from existing loop, cutting the defective portion of cable, providing to be required thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. all as directed by Engineer-in-charge. Note:- (i) The cost of excavation & earth work,returning filling, in relaying of sand / bricks and cost of drawing to be required length from protection pipe, breaking of brick work / concrete / plaster to be required and redoing to be required for work to match the existing surface shall be deemed to be included in quoted rates and nothing extra should be paid on this account.(ii) Additional cable/ protection pipe required at site shall be measured and paid seperatly. Note:- if the complaint not attend & resolved within 48 hrs, a pelenty of Rs 200 will be fined against per complaint, complete as directed by Engr-in-charge.
Restretching of LT ACSR conductor and GI wire of any size and on any type of poles including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles all as specified.
Supply and erecting pre-stressed concrete poles 9 mtr long of cross section (102mmx172mm) at top and (102mmx279mm) at bottom, class-10 complying with requirements of IS-1678-1978, zebra painting with two coats of synthetic enamel paint and making alternative black and white strips 30 cm each up to 1.5 mtr height from top of PCC foundation block, numbering of poles including necessary excavation & earthwork in any type of soil, PCC (1:4:8) in foundation , PCC (1:3:6) in coping , and dismantling the old pole and removal all the debris complete all as directed by the Engineer-in-Charge. Note:The T&P vehicles will be arranged by the contractor for transporting the pole from AGE (E/M) Elect store yard to site of work and the cost deemed to be included in the quoted rates.
Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
M&L Loop type insulator, vitreous porcelain, white, brown or green: Large size, with overall dimensions 90mmx140mm, learance of hole 25.5mm Note :- (i) Old unserviceable material retrieved from site shall be deposited to E/M yard in his own arrangements by the contractor. (ii) Item measured after depositing the old credit to the E/M yard and tallying the quantity both new and old materials retrived. (iii) Quoted rates included the dismantling of old unsv materials.
M&L Stay assembly (20mm dia rod) complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) Note :- (i) Old unserviceable material retrieved from site shall be deposited to E/M yard in his own arrangements by the contractor. (ii) Item measured after depositing the old credit to the E/M yard and tallying the quantity both new and old materials retrived. (iii) Quoted rates included the dismantling of old unsv materials.
M&L for Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Repair and Replacement of damaged service cable incluing supply and fixing 1100 volt grade alluminium solid conductor cable with pvc armoured tape and overall pvc sheathed nominal cross section in service connction complete all as specified of following sizes :-. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
6 Sqmm 2 core
4 Sqmm 2 core
M&L for electrical insulation tape roll of 25mm wide and 20 Mtr length heavy duty in repair/maintenance of cables or fixing of thimbles or colour coding of cables in panels/joints etc complete all as specified and directed.
Supply & fix in repair aluminium thimble/ferrule suitable for LT UG Cable,1100V for the following size of cable:- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
M&L for surface dressing not exc 15cm deep and averaging 10cm deep and cleaning of surroundings of electrical installations/sub stations/2 & 4 pole structure/Panels/transformers drainage installation by cutting vegetation, bushes, grass etc. and surface dressing, complete all as specified and directed by Engineer-in-charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
S&F of following accessories in repair of Lt panels of various sizes at various location complete all as specifed by Engr-in Charge or GE :- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Volt meter digital, 96 x 96mm size, 0-500 volts, AC, complete all as specified and directed.
Ampere meter digital, 96 x 96mm size, 0-500A size, AC, complete all as specified and directed.
Phase indicating lamps LED type RYB, complete all as specified and directed.
Die cast resin CT for digital Amp meter of any capacity and ratio of CT as per existing ground requirement, complete all as specified and directed Engineer-in-Charge.
Wiring of voltmeter or ammeter with copper conductor single core 1.5 sqmm size, complete all as specified and directed.
Supply & fix aluminium strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in replacement amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) single pole and current carrying capacity of following sizes in the MCB DB or FRP looping box of security lights or Lt panels of poles/panelscomplete with connection testing and commissioning. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
240V, 10KA 'C' curve miniature circuit breaker (MCB) single pole and current carrying capacity 6 to 32 Amps
240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN and current carrying capacity 32/63 Amps in the MCB DB or FRP looping box of security lights poles/panels complete with connection testing and commissioning.
M&L for shifting of Lt panels from the any existing site as directed and reinstalling it to the new site including jointing fixing of cables and all connected accessries complete all as specified and directed by Engr-in-charge. Note :- The quoted rated are included the T&P reqd for the said job and excavation, cement motar etc reqd to complete the job.
Checking, testing Taking out all the LT cables by cutting old rusted nuts,bolts etc, refreshing all the cables (one in comming and 4 to 8 out going) by providing new lugs, MS nuts, bolts & washers and Lt straight through joints if required including excavation work, returning filling, removal and making god. welding of panels hings including making proper locking arrangement of LT panel ront and rear doors and proper opening and clossing. Painting of LT Panels with smoke gray paint over a paint of redoxide. Marking incoming & out going feeder to particular block/ Bldg Nos with white paint etc. complete all as directed by engineer -in -charge.a) Excavtion and earth work for taking out cable loop will be included in the rate of the same deemed included in the quoted rate by the contractor, not paid seperately.
Material and Labour for Preparation of the old painted surfaces of feeder piller box / panel of any size any description and in any position including removel of faded & deteriorated paint either by hand scrubbing or by blow lamps , applying necessary filler coat and scrapping as required and applying two coats of synthetic enamelled paint (grey in colour) with using spray machine after coat of primer complete all as specified and as directed by Engineer-in-Charge.
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size 2 to 4 core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junctionbox/LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation,returning filling,relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid seperatly.
Taking out of Air circuit breaker 4 Pole 630 Amps to 1600 Amps, 415 Volt of breaking capacity not less than 50 KA to 65 KA with electronic/thermal/micro processor based release ,Manual drawout/Mechinical drawnout/ fixed , Any-Type/Make, , cleaning, servives & maint of any type ACB including replacement of worn out patrs and making fully smooth functioning upto to desire level , complete all as specified and as directed by Engineer-in-Charge. Note :- All the required spare parts will be included rates qouted by the contactor.
Material and Labour for in replacement Danger notice plate 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20cm x 15cm size complete all as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
SCH 'A' PART- II (FREE FOR FIXING ONLY)
Labour only in replacement MCCB 4 Pole, 415 V,of following breaking capacity, thermal magnetic type of capacity including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge fo following sizes :-. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
40/63/100 Amp 4 Pole, 16 KA
200 Amp,, 4 P, 36 KA
250 Amp, 4 P, 36 KA
400 Amp, 4 P, 36 KA
630 Amp 4 P, 50 KA
Labour only for Dismantling of U/S ACB and fixing new ACB 4 Pole,415 volt, with microprocessor release, adjstable release mannual fixed type of capacity of following sizes including testing & commisioning :- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Fixing only ACB 4 Pole,415 volt, with microprocessor release, adjstable release mannual fixed type of capacity 630 Amps, 50 KA (with sheet metal enclosure) including testing & commisioning .
~~~~Do~~~ but 800 Amps, 4 pole and 50 KA
Labour for laying, jointing and testing in replacement of u/s LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of following sizes:- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
185 Sqmm 3.5 core
70 sqmm, 3.5 core.
50 sqmm, 3.5 core.
25 sqmm, 04 core.
16 sqmm, 4 core.
10 sqmm, 4 core.
Note:- The contractor shall deposited the old material retrived from item no 01 to 46.06 to AGE E/M Electric Supply store yard by his own arrangements without any financial benefits and shall maintain the record for the same as specified by Engr-In-Charge and GE.
M/s Kataria Construction Company (BID ID -3150391)
AJ. Owners (BID ID -3151000)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .