Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹14.9 Cr
EMD Value
₹29.9 L
Closing Date
30 Nov 2026, 10:00 am5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
VIKAS DHANKHAR
Tosham PHED
Jaimalpura
2026_HRY_560582_1
202627639914 BE18 4F7B BCD6 33D5F1755042551PUH
Open Tender
Civil Works
Works
365 days
BALIALI Ramupura
Eligiblity Crieteria
2 documents required · 2 mandatory
₹20,000
₹29.9 L
Yes
PHED Tosham
17 Nov 2026
17 Nov 2026
30 Nov 2026
17 Nov 2026
30 Nov 2026
17 Nov 2026
17 Nov 2026 - 30 Nov 2026
23 Nov 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Credit of Old bricks available during dismantling | 42,051 | Each | - | - |
| 2 | Design, supply, installation, testing and commissioning of cubical type L.T. panel suitable for 630 V, 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 16 SWG thick for frame work and covers, 3 mm thick for gland plates i/c cleaning and finishing complete with 7 tank process for approved shades, having 630 Amp. Capacity extensible type TPN copper Bus bar for high conductivity, DMC/SMC bus bar supports, Panel Manufacturer shall have CPRI test certificate for short circuit with stand capacity of 31 MVA for 1 Sec. bottom based channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common tinned copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminium bus bar and control wiring with 2.5 sq. mm FRLS insulated copper conductor S/C Cable, Cable alleys, Cable gland plates in two half, i/c providing following switch gears etc. as required. The design and drawing of panel board will be approved from Engineerin-Charge before installation at site. Outgoing for pumping machineries and fully automatic ATS starter with following items: Incomer MCCB 630 Amp. 36 KA Ics 4 pole, complete with spreader links, phase barriers and ROM of make : LandT D Sine, Schneider NSX compact, Siemens 3 VL, Digital Multi Functional Meter with CT of 400/5 Amp. and RYB indicator for phase identification of Make :LandT Vega Series or equivalent in ABB and Siemens, Schneider, Siemens, ABB Outgoing Feeder 1 No. 630 Amp. 36 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine. Schneider NSX Compact, Siemens 3VL, for existing feeder (existing load)(Including third party inspection from any Govt. Agency ( as approved by Engineer-In-Charge) make as per Haryana DGSandD rate contract approved manufacturer. i) 1 No. MCCB 630 Amp. 25 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine, Schneider NSX Compact, Siemens 3VL. ii) 3 No. Inline contractor for fully automatic ATS starter AC 3x265 Amp. of make MNX 70 of LandT or equivalent in ABB/Siemens.iii) 1 No. fully automatic ATS starter for motor with inside delta connection min 70A for 6 wire Connection Cat No. EMX3- 0023B-411 of LandT or Equivalent model 3RW44 of Siemens/PSTB of ABB. Note :- Suitable Size of Semiconductor fuse shall be used for Backup protection of fully automatic ATS starter Design, supply, installation, testing and commissioning of APFC Panel of 14.50 KVAR of suitable steps capacity suitable for operation on 415 plus 5% volt, 3 phase, 50 Hz, AC supply having heavy duty static capacitors (Without oil) of suitable rating complete with TP MCCB of 630 Amps. 36 KA (Ics=100%) capacity with L.T. Panel with adjustable thermal magnetic bases release for over current and short circuit protection as incomer of the panel, of suitable step microprocessor based power factor controller, duty contractors for each capacitors protected with suitable rating MCCBs of minimum 18 KA ICs breaking capacity having thermal magnetic release for over load and short note circuit protection, cooling fans for panel and Digital multifunction meter, Class-1.0, indicating lights, earthing the panel etc. as reqd. The Panel should be manufactured with 2mm thick CRCA sheet duly powder coated etc. The APFC Panel shall be in continuous with L.T. Panel. Makes of Capacitor/ contactor/ MCCB/ APFC Controller : LandT/ Siemens/ ABB complete in respect to the satisfaction of Engineer-In-Charge. (For run the squirrel cage induction type energy efficient electric motor of 1440 RPM, 3 phase 50 Hz as per specification of efficient class IE-3 to run the raw water pump having discharge 3700 LPM with 40 mtr. Head) (Including third party inspection from CEIL). | 2 | Each | - | - |
| 3 | Supplying, erection, testing and commissioning or Horizontal motor pumping set or Clear Water having head 40.00 m as requirements of discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton Greeve, Lubi) Discharge Capacity (LPM) 3700 Power Capacity (BHP) 55.00 | 2 | Each | - | - |
| 4 | Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for Raw Water having head 35.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP Make: KSB, CRI, Kirlosker, Crompton Greeve, Lubi) (8550 Lpm 110 BHP ) | 2 | Each | - | - |
| 5 | Design, supply, installation, testing and commissioning of cubical type L.T. panel suitable for 630 V, 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 16 SWG thick for frame work and covers, 3 mm thick for gland plates i/c cleaning and finishing complete with 7 tank process for approved shades, having 630 Amp. Capacity extensible type TPN copper Bus bar for high conductivity, DMC/SMC bus bar supports, Panel Manufacturer shall have CPRI test certificate for short circuit with stand capacity of 31 MVA for 1 Sec. bottom based channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common tinned copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminium bus bar and control wiring with 2.5 sq. mm FRLS insulated copper conductor S/C Cable, Cable alleys, Cable gland plates in two half, i/c providing following switch gears etc. as required. The design and drawing of panel board will be approved from Engineerin-Charge before installation at site. Outgoing for pumping machineries and fully automatic ATS starter with following items: Incomer MCCB 630 Amp. 36 KA Ics 4 pole, complete with spreader links, phase barriers and ROM of make : LandT D Sine, Schneider NSX compact, Siemens 3 VL, Digital Multi Functional Meter with CT of 400/5 Amp. and RYB indicator for phase identification of Make :LandT Vega Series or equivalent in ABB and Siemens, Schneider, Siemens, ABB Outgoing Feeder 1 No. 630 Amp. 36 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine. Schneider NSX Compact, Siemens 3VL, for existing feeder (existing load)(Including third party inspection from any Govt. Agency ( as approved by Engineer-In-Charge) make as per Haryana DGSandD rate contract approved manufacturer. i) 1 No. MCCB 630 Amp. 25 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine, Schneider NSX Compact, Siemens 3VL. ii) 3 No. Inline contractor for fully automatic ATS starter AC 3x265 Amp. of make MNX 70 of LandT or equivalent in ABB/Siemens.iii) 1 No. fully automatic ATS starter for motor with inside delta connection min 70A for 6 wire Connection Cat No. EMX3- 0023B-411 of LandT or Equivalent model 3RW44 of Siemens/PSTB of ABB. Note :- Suitable Size of Semiconductor fuse shall be used for Backup protection of fully automatic ATS starter Design, supply, installation, testing and commissioning of APFC Panel of 14.50 KVAR of suitable steps capacity suitable for operation on 415 plus 5% volt, 3 phase, 50 Hz, AC supply having heavy duty static capacitors (Without oil) of suitable rating complete with TP MCCB of 630 Amps. 36 KA (Ics=100%) capacity with L.T. Panel with adjustable thermal magnetic bases release for over current and short circuit protection as incomer of the panel, of suitable step microprocessor based power factor controller, duty contractors for each capacitors protected with suitable rating MCCBs of minimum 18 KA ICs breaking capacity having thermal magnetic release for over load and short note circuit protection, cooling fans for panel and Digital multifunction meter, Class-1.0, indicating lights, earthing the panel etc. as reqd. The Panel should be manufactured with 2mm thick CRCA sheet duly powder coated etc. The APFC Panel shall be in continuous with L.T. Panel. Makes of Capacitor/ contactor/ MCCB/ APFC Controller : LandT/ Siemens/ ABB complete in respect to the satisfaction of Engineer-In-Charge. (For run the squirrel cage induction type energy efficient electric motor of 1440 RPM, 3 phase 50 Hz as per specification of efficient class IE-3 to run the raw water pump having discharge 8750 LPM with 35 mtr. Head) (Including third party inspection from CEIL). | 2 | Each | - | - |
| 6 | Supplying, erection, testing and commissioning or
Horizontal motor pumping set or Clear Water having head
as requirements of discharge in LPM and power
capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton
Greeve, Lubi) Discharge Capacity (LPM)
Capacity (BHP) 30.00.. | 1 | Each | - | - |
| 7 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)
START DELTA STARTER :-
1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos
2. Controlling MCB - 01nos
3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos
4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos
5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)
6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos
7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos
8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos
9. CAPACITOR BANK AS PER LOAD REQUIREMENT
10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos
11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos
12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos
13. ELCB BREAKER (ABB/LandT/SCHNEIDER)
30 BHP | 1 | Each | - | - |
| 8 | Operation and Maintenance for complete scope of work mentioned in the DNIT (Disinfection material supplied by PHED) as per schedule-IV for a period of 5 year after 12 month during defect liability period and 03 Months trial run period will be charged to the A/ Mtc. estimate complete in all respect as per Approved NIT.
(i) During defect liability period (Operation only) after 3 month Trial run period. | 1 | Job | - | - |
| 9 | (ii) During 1st year after defect Liability period. | 1 | Job | - | - |
| 10 | (iii) During 2nd year. | 1 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
BOQ_640648.xls
BOQ • 0.29 MB
NCAEM0Z185617.pdf
Additional Documents • 2.67 MB
OT0185617.pdf
Other Document • 2.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .