Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.3 CrAccepted-AOC RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | ₹2.3 Cr | 1 | Accepted-AOC BEING LOWEST |
| 2 | 2₹2.3 Cr+₹2.7 L (1.18%)Rejected-Finance | ₹2.3 Cr+₹2.7 L (1.18%) | 2 | Rejected-Finance Other than lowest |
| 3 | 3₹2.4 Cr+₹11.4 L (5.01%)Rejected-Finance DH 101 DEEN DAYAL NAGAR MAHARAJPUR GWALIOR 474020 MP | GWALIOR | MADHYA PRADESH | 474020 | ₹2.4 Cr+₹11.4 L (5.01%) | 3 | Rejected-Finance Other than lowest |
| 4 | 4₹2.6 Cr+₹32.8 L (14.4%)Rejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹2.6 Cr+₹32.8 L (14.4%) | 4 | Rejected-Finance Other than lowest |
| 5 | 5₹2.6 Cr+₹35.9 L (15.8%)Rejected-Finance OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | ₹2.6 Cr+₹35.9 L (15.8%) | 5 | Rejected-Finance Other than lowest |
Tender Value
₹3.1 Cr
EMD Value
₹3.9 L
Closing Date
8 Nov 2022, 6:00 pmClosed
CWE AF GWALIOR
CWE AF GWALIOR
IMPROVEMENT OF LIVING IN ACCOMMODATION FOR CPL AND BELOW AT AF STN GWALIOR
2022_MES_531621_3
85031/E8
Open Tender
Civil Works
Item Rate
540 days
GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,000
GE (AF) ADM AREA GWALIOR
₹3.9 L
Yes
19 Dec 2022
7 Oct 2022
16 Nov 2022
7 Oct 2022
8 Nov 2022
25 Oct 2022
Amount
Demolition of plain cement concrete (unreinforced) of any mix / grade in ground floor and pavings not exceeding 15cm thickness (below or above ground level) including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed .
Dismantling, floor, hearth or wall tiling including cement mortar bedding complete and removing rubbish off from the premises complete all as specified and directed.
Taking down cement plaster of brick or stone masonry etc including raking out joints , hacking for key & scrubbing down with water etc complete all as specified & directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, staircases, landings and similar suspended work (reinforcement cut as required to facilitate demolition) including removal of debris out off the premises / MOD land complete all as specified & directed.
Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off the AF station premises / MOD land etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
Demolition of plain cement concrete (unreinforced) of any mix / grade ,any description and in any position other than ground floor (for sunken portion ) exceeding 15 cm thickness including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed .
M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surface , finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick / external surface of masonry wall using liquid water proofing compound mixed by weight of cement as per manufacturers instructions surface finished even and smooth without using extra cement complete all as specified and directed. (Note: WPC will be measured & paid separately under respective item of BOQ )
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surface of ceiling finished even and smooth without using extra cement complete all as specified & directed.
Supply only polymer liquid water proofing compound of approved make all as specified & directed
M&L for glazed ceramic digitally designed coloured tiles 450 mm X 300 mm X 6 to 7 mm thick with highlighter on vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including 10 mm thick backing coat in cement mortar (1:4) etc complete all as specified & directed.
M&L for premium quality non skid joint free digitally designed coloured ceramic floor tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles ,over & including 15 mm thick screed bed in cement mortar (1:6) complete all as specified & directed.
M&L for 15 mm to 18 mm thick Baroda green marble slab of approved type / variety (table rubbed and pre mirror polished) in window cill, jambs, steps, and cooking platforms including pointing in coloured cement to match with shade of Baroda green marble slab including half moulding of Baroda green marble slab edges over & including 20 mm thick screed bed in CM(1:4) for laying of Baroda green marble slab etc complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 18 mm to 25 mm thick of size not less than 575 mm X 575 mm over and including 75 to 100mm wide marble strip as motif laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing over & including 20 mm thick screed bed in CM (1:6) complete all as specified & directed.
M&L for machine cut kota stone slab in riser of steps (single piece), skirting 18 to 22 mm thick, laid and jointed with grey cement slurry pointed with coloured cement to match the shade of the slab including grinding rubbing & polishing over 10 mm thick backing coat in CM (1:4) etc complete all as specified & directed.
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware etc complete all as specified & directed.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc including builders hardware etc complete all as specified & directed .
M&L for Factory made Single extruded WPC solid door frame of size 125 mm X 63 mm double rebate comprising of virgin PVC polymer of k value 50-60 (suspension grade),calcium carbonate and natural fibres and non toxic additives (maximum toxicity index of 12 for 100 grams) fabricated with miter joints and applying PVC solvent cement and screwed with full body threaded star headed SS screw having minimum frame density of 780 kg/cum , screw withdrawal strength of 2220 N (face ) & 1100 N (edge) minimum compressive strength of 58 N/sqmm, modulus of elasticity 900 N/sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in portion single/double leaf complete all as specified
S&F Factory made solid panel PVC door shutter 35 mm thick solid panel PVC(style) consisting of frame made out of M.S tubes 19 gauge thickness and size 19 x19 mm for stiles and 15x15mm for the top and bottom rails M S frame shall have a coat of metal primer of approved make and manufacture. M S frame shall be covered with heat moulded (100% LEAD FREE) plain PVC 'C' channel made from 5mm thick sheet of density 600kg/cum manufactured by an ISO 9001-2015 certified company of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles and 5 mm thick 95 mm wide plain PVC sheet out which 75mm shall be flat and 20mm shall be tapered in 45 angle on inner side to form top and bottom and lock rail and 115mm wide PLAIN PVC sheet out which 75mm shall be flat and 20mm shall be tapered on both side to form lock rail Top bottom and lock rail shall be provided either side of the panel. An additional 5mm thick shall be provided either side of the panel. An additional 5mm thick PVC strip of 20mm width is to be stuck on the bottom side of the C channel paning of 5mm thick plain PVC sheet to be fitted inside the M S frame welded /seated to the styles and rails with 5mm x 30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc 10mm thick ,20 mm wide cross PVC sheet as gap insert for the top rail & bottom rail. Door to be fixed to frames with 3 nos. MS powder coated butt hinges of size 100mm x25mm x2mm using 32mm long steel screws drilled suitable to pass through both the walls of the M S tube other hardware should be fixed with 19x6mm six steel screws complete all as specified and directed.cted.
S&F Factory made wire mesh solid PVC door shutter 35mm thick solid panel PVC(style) consisting of frame made out of M.S tubes 19 gauge thickness and size 19 mm x19 mm for stiles and 15 mm x15mm for the top lock and bottom rails. M S frame shall have a coat of metal primer of approved make and manufacture 19 mm x 19 mm M S frame shall be covered with heat moulded (100% lead free) plain PVC 'C' channel made from 5mm (+_)0.25% thick PVC sheet of density 600kg/cum manufactured by an ISO 9001-2015 certified company of size 35mm thickness 90mm width out of which 75mm shall be flat and 15 mm shall be bend in 90 degree angle on either side forming stiles as well as rails to inner side of door to hide wire mesh fixing steel screw and 5 mm thick 115 mm wide PVC sheet out which 100 mm shall be flat and 15 mm shall be bend in 90 degree angle on inner side to form top and bottom and lock rail and 130 mm wide PVC sheet out which 100 mm shall be flat and 15 mm shall be bend in 90 degree on both side to form lock rail. An additional 5mm thick (+_0.25) PVC strip of 20mm width is to be stuck on the inner side of the C channel using PVC solvent cement adhesive panel with a GI/SS wire mesh of 0.36 mm to be fitted inside area of stiles and rail. The wire mesh in top, bottom and locked rail is sealed with 15 mm X 15 mm tube with steel screw of 13 X 6 mm.10 mm(5mm X 2 Nos) thick PVC strip of 25 mm width Is to be struck and nail on both side of GI wire mesh interior at the top, bottom and locked rail 10 mm thick 10mm thick ,20 mm wide cross PVC sheet as gap insert for the top rail & bottom rail. Door to be fixed to frames with 3 nos. MS powder coated butt hinges of size 100mm x25mm x2mm using 32mm long steel screws drilled suitable to pass through both the walls of the M S tube other hardware should be fixed with 19x6mm six steel screws complete all as specified and directed.
M& L for solid PVC door frame of size 50 mm X 47 mm made out of 5 mm extruded 5 mm thick PRELAM PVC Sheet of density 600 kg/cum Manufactured by an ISO 9000: 2015 certified company having pattam width of 50 mm and thickness of 10 mm providing weather sea/Non-woven self adhesive gasket throughout the frame. All three frame lengths reinforced with 19 mm x 19 mm MS Square tube of 19 gauge mitred cut at two corners and joined with 2 nos of 150 mm long brackets of 15 mm x15 mm MS square tube. The door frame shall be fixed to the wall using 80/100mm long M S screws through the frame by using PVC fasteners. A minimum of 4 nos of screws to be provided for each vertical member and minimum 2 nos for horizontal members etc complete as per manufactures specification and direction of Engineer – in – Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick solid panel PVC(style) consisting of frame made out of M.S tubes 19mm gauge thickness and size 19 x19 mm for stiles and 15x15mm for the top and bottom rails M S frame shall have a coat of metal primer of approved make and manufacturer. M S frame shall be covered with heat moulded (100% LEAD FREE) plain PVC 'C' channel made from 5mm thick sheet of density 600kg/cum manufactured by an ISO 9001-2015 certified company of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles and 5 mm thick 95 mm wide plain PVC sheet out which 75mm shall be flat and 20mm shall be tapered in 45 angle on inner side to form top and bottom and lock rail and 115mm wide plain PVC sheet out which 75mm shall be flat and 20mm shall be tapered on both side to form lock rail Top bottom and lock rail shall be provided either side of the panel. An additional 5mm thick shall be provided either side of the panel. An additional 5mm thick PVC strip of 20mm width is to be stuck on the bottom side of the C channel paning of 5mm thick plain PVC sheet to be fitted inside the M S frame welded /seated to the styles and rails with 5mm x 30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc 10mm thick , 20 mm wide cross PVC sheet as gap insert for the top rail & bottom rail. Door to be fixed to frames with 3 nos. MS powder coated butt hinges of size 100mm x25mm x2mm using 32mm long steel screws drilled suitable to pass through both the walls of the M S tube other hardwares should be fixed with 19x6mm six steel screws complete all as specified and directed.
S&F for stainless steel handles of 125 mm long for shutter etc complete all as specified and directed.
S&F for stainless steel handles of 75 mm long for shutter etc complete all as specified and directed.
S&F for stainless steel butt hinges of 100 mm long for PVC door shutter complete all as specified and directed..
S&F Stainless Steel barrel tower bolts of extruded section and fixed 150mm long complete all as specified and directed.
S&F Stainless Steel barrel tower bolts of extruded section and fixed 100mm long complete all as specified and directed.
S&F for 250 mm long stainless steel sliding door bolts( bolt type ), with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts and fixed complete all as specified and directed.
S & F for mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S & F for floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring over all length of cover plate 150mm complete all as specified and directed.
Supply and fixing of rubber beading door seal 40x 5mm strip in bottom of door complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregate ) as in coving on chajja, balcony or in roof Kerbs, benching,coping , bed plates for fixing hold fast bed block ,kerb stone in sides of interlocking tiles , rounded or chamfered on edges and similar work including necessary formwork complete all as specified and directed.
M&L for applying acrylic based waterproofing, flexible, liquid applied, single component, weather resistant, acrylic waterproofing membrane for all types of exposed roof slabs (new and old), terraces (sloped and flat), ultra violet rays and heat reflection system having following key performance properties: 1. Acrylic polymer dispersion single component liquid appalled system sika cool coat not less than 650 micron (1.2mm system built up), contains Cross-linking polymers, Special Glass micro fibers, pigments and advanced antifungal additive that provides long lasting tough water proofing membrane conforms to: IS101, IS 2645, EN 1542, ASTM D 5589, ASTM D 5590, ASTM C-1202-08, ASTM D 4587, ASTM C 836, ASTM E1980, EN-673, EN 410. It should have solid content - 66% (by weight), VOC<10 gm/I complies to Green building standards and should meet the properties of Adhesion Strength on cement after 14 days curing > 1.5N/sqmm as per EN E1542, tensile strength 1.5 MPa as per ASTM D 41, crack bridging properties 3.2mm as per ASTM C-836, water absorption (%by mass) < 10% as per ASTM D570, solar reflectance index not less than 100(5%) (low wind to high wind condition), elongation at break (%) 200% as per ASTM D 412, algae & fungal resistance as per ASTM D- 5590, should have a hardness 45 after 1 month and should pass accelerated weathering, 500 hours without any cracking & 100% gloss retention as per ASTM D 4587. 2. Fully reinforced with glass fiber reinforced sika fab 1. 3. The roofing system should be compatible with bitumen system. 4. Side termination bar of 2mm thick aluminium valley strip with one side bending for membrane termination to be used with SBF fasteners. 5. Providing and applying primer over the prepared surface with sika cool coat primer @ coverage: 0.1-0.12 kg/sqm. first coat: sika cool coat consumption @ 0.5 kg/sqm. Reinforcement : sika Fab 1. second coat: sika cool coat consumption @ 0.5kg/sqm. Third coat: sika Cool cat, consumption@ 0.5kg/sqm and Top coat: sika cool coat primer, consumption @0.05-.08kg/sqm all as per specification & direction of the engineer -in -charge. Note : - Contractor may use equivalent chemicals of equivalent makes from latest approved list of E-in-C’s Branch as approved by GE. The work shall be executed by authorized applicators of make approved by E-in-C branch. The contractor have to submit MOU to the GE within 15 days after placing of Work order No1.
(i) Cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any share edges, etc (ii) M&L for sealing of pipe penetration of toilets core cutting in the following stages :- Supply and apply solvent sikagard 694 F(I) or equivalent, free moisture insensitive epoxy resin based patch repair putty on pipe penetration surfaces. The moisture insensitive putty with yield : 0.6 ltr/kg suitable for submerged condition; compressive strength of 40 N/sqmm (1day) according to IS 9162-1979. The putty shall be applied to a groove thickness of minimum 20mm on pipe penetration joint to concrete as per direction of the Engineer –in-Charge (iii) Supply and apply a glass fiber reinforced acrylic modified cementitious coating system. Preparation of surface of sunken portion and M & L for glass fibre reinforced acrylic modified cementitious coating system as top coat: Sika to seal -107 or equivalent @1.5kg/sqm over reinforcement: Sika fab-1 or equivalent over base coat: Sika top seal-107 or equivalent @1.5kg/sqm etc all as specified and directed system should have compressive strength : 20 N/sqmm; bond strength : 2.0 N/sqmm. (iv) On Horizontal surface : supply and apply a protection screed 1:2 in 50 mm thickness laid to be admixed with integral waterproofing compound sika plastorcrete plus or equivalent confirming to IS 2645 at the rate of 0.10 kg per bag of cement. (v) On vertical surface: Supply and apply a protection plaster in CM 1:3 (12-15mm thick) admixed with appropriate integral waterproofing compound admixture : Sika pastorate plus or equivalent @ 0.10 kg per bag of cement. Product requirements admixture: conforms to IS 2645. Note : Contractor may use equivalent chemicals of equivalent makes from latest approved list of E-in-C’s Branch as approved by GE. The work shall be executed by auth applicators of make approved by E-in-C branch. The contractor have to submit MOU to the GE within 15 days after placing of Work order No1.
M & L for PCC 1:5:10 type E-2( using 40 mm graded crushed stone aggregate) as in filling under sunken floor of toilet and bath room etc complete all as specified & directed.
Use & waste of formwork to soffits of suspended slabs such as roof slabs floor slabs, landing and similar work not exceeding 200mm thick (Horizontal or Sloping) complete all as specified and directed.
S&F TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
M&L for reinforced cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) ,as in chajjas repairs complete all as specified and directed.
M & L for 75mm thick PCC (1:3:6) type C-1(using 20mm graded crushed stone aggregate) as in plinth protection laid in panels and joints filled with mix of bitumen and sand (1:3) by weight, finished the surface even and smooth using extra cement including demolition of damaged plinth protection and removal of debris out off the premises etc complete all as specified and directed.
M & L for providing and injecting chemical emulsion for Post Construction Anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 Litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
M & L for post construction anti-termite treatment of soil under existing floors using chemical emulsion @ one litre per hole , placed 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors etc complete all as specified and directed.
S&F in repair stainless steel 20 mm dia (wall thickness not less than 1 mm ) as hanger rod in required length for Cupboard/wardrobe/ curtain rod etc excluding mild steel approved pattern brackets & socket complete all as specified & directed.
S&F mild steel prepainted brackets suitable to hold the drapery rods/curtain rod 20 mm dia and fixed to wall (concrete /bricks masonry ) with the help of 02 Nos , 50 mm long steel screws and rawl plug including drilling with electric drill & making good the disturbed surface ,colour & pattern as approved by GE complete all as specified and directed.
S & F SS (Stainless Steel) decorative corner/end cap for Curtain rod complete all as specified and directed.
S&F stainless steel peg set of six with base plate and fixed to wall/door with rawal pugs/ s/s screw complete all as specified and directed.
S&F shelf of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleats (minimum weight 300 gms ) complete all as specified and directed.
S & F in repair brass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, complete all as specified and directed.
S&F in repairs WC squatting pan " Orissa Pattern" of size 580 X 440 mm white with integral foot rest including PVC P or S trap, front or back inlet and making connection to trap & to flushing cistern and lime concrete bedding complete all as specified & directed.
S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flush system valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set all as specified and directed.
S & F in repair vitreous China wash hand basin white angle back size 600 mmx480mm fixed on and including brackets,32mm dia brass waste coupling and 32 mm dia PVC waste pipe (rigid quality) including PVC connection 15 mm size with PTMT nuts of length 450 mm & fixing of tap etc. etc.complete all as specified and directed. Note :- Pillar tap shall be measured & paid separately as supply only under respective item of BoQ".
Supply only 15 mm bore pillar tap cock quarter turn with water saving nozzle with or without lettered 'Hot' or 'cold' with iron pipe and fixed complete all as specified & directed.
S&F in repair concealed stop cock fancy type chromium plated with long shank & cup cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both end of size 15 mm bore complete all as specified and directed.
S&F in repairs brass chromium plated shower rose with swivel joints, 125 mm size in square with chromium plated long shank arm including fixing to steel pipe or union complete all as specified & as directed.
S&F in repair concealed angle cock chromium plated with long shank & cup cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both end of size 15 mm bore complete all as specified and directed.
S&F in repair 15 mm bore bib taps, with flanges quarter turn with water saving nozzle screwed for iron pipe and fixed complete all as specified & directed.
S&F in repair PVC connection 15 mm size 600mm long with PTMT nut complete all as specified and directed.
S&F in repair grating doom with hole or without hole 100 mm dia of CP (minimum weight 150 gms) complete all as specified and directed.
S&F rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI medium grade over flow ( 450mm long) and washout pipe (600 mm long ) with fittings including dismantling of existing tank and lowering down etc complete all as specified and directed.
S&F in repair 20 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified & as directed.
S&F in repair gun metal globe or gate valves(ISI MARK), with iron wheel head, screwed both ends for iron pipe 20 mm bore complete all as specified and directed.
Dismantling of cast iron of 75 mm/100 mm bore, jointed in cement mortar by taking out of trenches upto first manhole complete all as specified & directed.
M&L for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including taking up or down steel tubing and connections 15 mm bore,complete all as specified & directed.
M&L for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including taking up or down steel tubing and connections 20 mm bore,complete all as specified & directed.
M&L for GI water tubing medium grade, ISI marked, galvanised, 32 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including taking up or down steel tubing and connections 32 mm bore,complete all as specified & directed.
S&F in repair 110 mm bore PVC (SWR) Soil/waste and vent pipe in any length single socketed with rubber ring joints fixed to wall,laid under floor etc complete all as specified and directed.
S&F 110 mm bore PVC (SWR) soil waste pipe for sanitary connection socket to fit WC outlet complete all as specified & directed
S&F in repair 110 mm bore PVC (SWR) vent cowl complete all as specified and directed
S&F in repair PVC bends 110mm bore of pipe branch piece single (equal or unequal) ordinary or inverted ordinary as inverted spigot and rocket type or with parallel branches or ‘T’ piece with oval access door with solvent joint complete all as specified and directed
S&F in repair 110 mm bore PVC (SWR) branch piece,single (equal or unequal) ordinary or spigot and socket type or with parallel branches as ‘T’ piece with access doors complete all as specified and directed
S&F in repair 75mm bore PVC (SWR) (equal or unequal) ordinary or inverted spigot and socket type or with parallel branches or ‘T’ piece with overall access door with solvent joints complete all as specified and as directed
S&F in repair stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roofs for 100 mm bore pipe etc complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) pipe soil/ waste and vent pipes in any length with rubbering joints fixed to wall, laid under floor etc complete all as specified and as directed
S & F in repair 75mm bore PVC (SWR) (any radius) diminishing pieces or tapers (large bore measured) with access door with solvent joint complete all as specified and as directed
S&F in repair PVC bends 75mm bore (any radius) diminishing piece or tapers larger measured) with solvent joint all as specified and directed
S&F in repair PVC bends 75mm bore of pipe branch piece single (equal or unequal) ordinary or inverted ordinary as inverted spigot and rocket type or with parallel branches or ‘T’ piece with oval access door with solvent joint complete all as specified and directed
S&F in repair PVC (SWR) 75mm bore pipe branch piece single (equal or unequal) ordinary or inverted spigot and socket type or with parallel branches or ‘T’ piece with solvent joint complete all as specified.
S&F in repair 75mm bore PVC (SWR) floor trap including jointing to waste pipe fixed in cement concrete type B-I 1:2:4 (using 20mm graded crushed stone aggregate) complete all as specified and directed.
M&L for PVC (SWR) gully trap 125/110 mm ,setting and jointing with solvent cement complete all as specified and directed.
S&F in repair stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roofs for 75 mm bore pipe etc complete all as specified and directed.
M & L for preparation of new surface of walls and apply two coats distemper oil emulsion (OBD) with roller finish over a coat of cement wall primer from same manufacturer of (OBD) over and including layer of wall care putty not less than 3mm thick completed all as specified & directed.
M&L for complete removal of existing treatment from old surface of wall, shall be sanded through mechanical wall sander to remove all the previous layer and exposes the plaster surface, including filling depression of scrapped surfaces and apply two coats of distemper oil emulsion (OBD) over a coat of cement wall primer from same manufacturer (of OBD) and shall be allowed to dry 6-8 hrs the surface for painting subsequent coats over a layer of wall care putty not less than 3mm thick complete all as specified and directed. Note: (i) Surface shall be sprayed with water proof cementious putty from airless spray machine .Putty shall be prepared in liquid form as per manufacturer's specifications and shall be allowed to dry for 6 to 8 hours. (ii) Primer/ paint shall be applied with fully automatic airless spray machine. Time period of 6 to 8 hours shall be allowed to dry the surface for painting of subsequent coats. (iii) The work shall be executed by auth applicators of make approved by GE.
M&L for preparation of old or untreated steel surface of any description , not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for preparation of old or untreated wooden surface of any description , not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coat distemper emulsion (OBD) with roller finish over a coat of cement wall primer (for same manufacturing of OBD) over and including layer of wall care putty not less than 3mm thick complete all as specified and directed.
M&L for complete removal of existing treatment from ceiling (any number of layers) by rotary scrappers/sand cutting machine to achieve paint/periodicals free even and smooth finish plastered surfaces and applying two coats of distemper oil emulsion (OBD) with roller finish over a coat of cement wall primer (from same manufacturing of OBD) over and including layers of wall care putty not less than 3mm thick completed all as specified & directed.
S&F vitreous china urinal full stall urinal complete including providing and fixing plug bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60mm brass screws pointing around urinal back in cement, including fixing CP water spreader with brackets, flush pipe, , CP grating and union for discharge pipe ,any accessories which are required to stall the urinal. Complete all as specified and directed
M&L for Roof tiles mangalor pattern interlocking at side joints over screed bed or bedding layer of mortar 20mm thick with cement mortar 1:4 for laying floor finish with & including water proofing compound as per manufacturing instructions etc complete all as specified and directed. Note: WPC will be measured & paid separately under respective item of BOQ,
M&L for PCC 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) in roof kerbs or mud stops, including finishing the surface with grinder to receive the acrylic based water proofing material as mentioned in item no 1.34 here in before, rounded or chamfered on edges etc complete all as specified and directed.
Removal of existing felt/if any waterproofing treated system from the roof slab & cleaning the surface to remove dust, loose particles,etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges etc. complete all as specified and directed.
S & F powder coated anodised aluminium frame for windows, ventilators with one or more rebates including aluminium openable shutter for window & joining cleat for fixing etc complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings such as peg stays 150mm long (1No.),100mm long hinges type B-21 (2Nos) suitable handle(1No.)complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples etc complete all as specified & directed.
S&F 4.0 mm thick sheet glass, ordinary quality in square/ rectangular, not exceeding 0.5 Sqm in each pane complete all as specified & as directed.
S&F 4.0 mm thick figured glass pin headed type in squares/ rectangular not exceeding 0.5 Sqm in each pane complete etc complete all as specified & directed.
S&F for powder coated aluminium deco grills size 4mmx4mm, 5.8mm thick and aperture not exceeding 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint match with existing shade including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminum powder coated standard section around the opening complete all as specified & directed.
M&L for applying two or more coats of 100% premium emulsion paint having VOC less than 50gm / litre and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade roller finish (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat to be applied with fully automatic airless spray machine of paint application and allow 6-8 hrs dry the surfaces for painting of sub squint coats of exterior primer applied @0.90 litre/10 sqm over & including layer of wall care putty not less than 3mm thick including necessary scaffolding etc complete all as specified and directed. Note: (i) Surface shall be sprayed with water proof cementious putty from airless spray machine .Putty shall be prepared in liquid form as per manufacturer's specifications and shall be allowed to dry for 6 to 8 hours. (ii) Primer/ paint shall be applied with fully automatic airless spray machine. Time period of 6 to 8 hours shall be allowed to dry the surface for painting of subsequent coats. (iii) The work shall be executed by auth applicators of make approved by GE.
M&L for complete removal of existing treatment of external surface of wall, shall be sanded through mechanical wall sander and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm / litre and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade with roller finish (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over and including a layer of wall care putty not less than 3 mm thick including necessary scaffolding etc complete all as specified and directed. Note: (i) Surface shall be sprayed with water proof cementious putty from airless spray machine .Putty shall be prepared in liquid form as per manufacturer's specifications and shall be allowed to dry for 6 to 8 hours. (ii) Primer/ paint shall be applied with fully automatic airless spray machine. Time period of 6 to 8 hours shall be allowed to dry the surface for painting of subsequent coats. (iii) The work shall be executed by auth applicators of make approved by GE.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft /loose soil etc complete all as specified and directed.
M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & levelled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed.
M&L for 60 mm thick pressed approved factory made precast concrete rubber moulded glossy finished interlocking paver block of any size & shape conforming to IS:15658-2006 of compressive strength not less than 350 Kg/sq.cm (M-35) including laying over & including 50 mm thick Stone dust cushion (filling) and joints filled with sand etc and 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. NOTE : Manufacturer’s test certificate of Interlocking paver block shall be produced on each/every lots before making payment.
Removal of surplus excavated spoil exceeding 1.50km but n’exc 5.00km distance and depositing where directed by Engineer-in-Charge complete all as specified.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete etc complete all as specified and directed.
M&L for brick work with old size sub class "B" bricks built in cement mortar 1:4 straight or curved on plan exceeding 6.0 mean radius complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) as in surface channels and drains etc complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar (1:4) on brick work finished even and smooth without using extra cement all as specified and directed.
M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, including forms, moulds, etc (inner girth only to be measured) complete all as specified and directed.
Add or deduct to Srl item No. 2.09 here in before for each 25mm girth or part thereof over or under 30cm inner girth of drain or channel ditto
Returning, filling in including spreading, levelling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Cleaning of first manholes of any description and in any position depth n’exc 1.5mtr deep mechanically or manually by taking off sludge waste/ night soil and silted soil from the existing manhole of any size, collecting and removal of sludge in sealed container out side Air Force boundary and disposal of the same complete all as specified and directed
Demolition and breaking up rain water pipes (SGSW, AC or RCC) of internal dia 150 mm, set in cement mortar including removal of debris out off the AF station premises / MOD land complete all as specified and directed.
M&L for reinforced concrete pipes, class NP-3, 150 mm bore, laid and jointed in cement mortar 1:1 with collars and tested complete all as specified & directed.
M&L for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested complete for pipe of 100mm bore complete all as specified & directed.
M&L for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested complete for pipe of 150mm bore complete all as specified & directed.
Cutting into existing manholes for connecting new drains of internal dia of pipe 150mm making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required
Cutting into existing manholes for connecting new drains of internal dia of pipe 100mm making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete etc complete all as specified and directed.
M&L for providing pre-cast cement concrete 1:2:4,type B-1 (using 20mm graded crushed stone aggregate) as in cover slab , RCC flatform set in cement mortar 1:4 etc for cable duct and base for antenna or similar work etc complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately under respective items of BOQ)
M& L for mild steel TMT bars 8 mm dia grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
Removal of surplus excavated spoil not exceeding 1.5 Kms distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
M&L for Cutting holes in brick walls built in cement mortar as cement lime mortar for inserting hold fasts and making good dismantled portion in CM 1:6 and cement concrete 1:2:4 type B-I as required depth of imbedded portion of hold fasts exc half brick but n’exc one brick
M&L for preparation of newly plaster surfaces of ceiling, wall and any places etc and applying three coat of white wash complete all as specified as directed
M&L for complete removal of existing treatment from ceiling, walls and any places by scrapping with mild steel scrappers of any other means, including filling depression scrapped surface with preparation of plastered surface and applying two coats of white wash etc completed all as specified & directed etc
M&L for 18 to 20 mm thick machine cut pre polished kota stone slab in single piece in treads of steps including bull nosing & cutting two serrations on top set & jointed in neat cement slurry & pointed in coloured cement to match over & including 20 mm thick screed bed in CM (1:6) etc complete all as specified & directed
Taking down door shutter of any description exc 1 sqm but not exc 2 sqm resecuring or easing and adjusting and refixing in same opening / other opening complete all as specified and directed by Engineer-in-charge.
Taking down door shutter of any description exc 2 sqm resecuring or easing & adjusting and refixing in same/other opening complete all as specified and directed by Engineer-in-charge
Taking down carefully existing unserviceable copper/ aluminium point wiring of any description & in any position with and including PVC/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. NOTE: Old fittings/fixtures/accessories like switches, sockets, lamp holders, regulators light fittings etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under respective item of BOQ.
M&L for Point wiring using FRLSH PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLSH PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar (1:4) and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for one light /ceiling fan/Exhaust fan point etc controlled by one way switch complete all as specified and directed. NOTE :-(i) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & caping of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Fittings like switch/bell push, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers complete.
All as per Srl item No.2.30 above but for 5 pin switch socket outlet combination, 5/6 Amps point on independent board controlled by one switch 5Amp, one way, etc complete all as specified and directed.
All as per Srl item No. 2.30 above but for 5 Pin 5 Amp socket outlet point controlled by one switch 5 Amps one way on same board, etc complete all as specified and directed.
All as per Srl item No. 2.30 but one light point controlled by two, two way switches etc complete all as specified and directed..
M&L for point wiring with 4 sqmm single core 1100 volt grade FRLSH PVC insulated unsheathed multistranded copper conductor with in and including PVC concealed conduit medium grade with all fittings including pressed MS sheet (1.6mm thick) sunken box with 3mm laminated sheet cover ISI marked suitable an independent 6 pin 15/16 Amps socket outlet including 4 sqmm single core 1100 volt grade FRLSH PVC insulated unsheathed multistranded copper conductor connected to common earth dolly including cutting chases in wall /floors for concealed and making good disturbed surface area to match wiih the adjoining surface all as specified and directed.
S&F switch piano, flush type, single pole, one way 5 amps 230 volt AC ISI marked white ivory finish complete all as specified and directed.
S&F switch piano, flush type, single pole, two way 5 amps 240 volt AC ISI marked white ivory finish complete all as specified and directed.
S&F socket outlet, five pin, 5/6 Amps flush type, 230 volts AC ISI marked white ivory finish complete all as specified and directed.
S&F switch socket outlet combination multi purpose, five pin ,5/6 Amps flush type, 230 volts AC circuit ISI marked with indicator complete all as specified and directed.
S&F ceiling rose, surface bakelite 18 mm X 50 mm AC, 230 V polycarbonate isolated body , two or three terminals complete all as specified and directed.
S&F lamp holder PVC/Polycarbonate type with cord grip cap/back plate suitable for batten/angle /pendent fitting complete all as specified and directed.
S&F fan regulator electronic, step type hum free, socket type , suitable for ceiling fans of any capacity, pre wired 230 volts AC 50 HZ supply 100/120 Watt complete all as specified & as directed
Supply & Fix for decorative slim linear LED tube light fitting batten type 01x20 watt light with co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with all accessories and connecting the same to ceiling rose with using copper conductor 24/0.20 flexible PVC sheathed and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified & directed by Engineer in-charge
S&F 1X10 W watt LED Bulkhead fitting with IP 65 environmental friendly, ultra modern, energy saving mounted decorative oval bulk head edge lit LED luminaire comprising of high brightness LED 230 Volts AC circuit complete all as specified and as directed.
S&F Street/Security light fittings 1X35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP-66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(max) with complete (40 mm dia GI pipe light grade ),clamp,nut-bolt and washers all directed by Engineer-in-Charge.
Disconnecting & taking up or down existing unserviceable MCB DB VTPN with all MCB's/Isolator & metal clad box of any description and in any position with existing fittings (MCB's) complete all as specified & as directed.
Supply and fixing of sheet metal enclosure Double door for DB’s 8 way 240 Volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
S & F factory made epoxy powder coated distribution board TP & N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts including provision for housing MCCB in the incoming and MCBs in the out going complete all as specified & directed .
S & F factory made sheet metal enclosure Double door for DB’s 4 way 415 volts, triple pole and neutral supply complete, fixed properly on MS strips and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified & directed .
S&F MCB SP 6 to 32 Amps ('C' Series) having current rating 10 KA complete all as specified and as directed .
S&F MCB SP&N 63 Amps ('C' series) having current rating 10 KA including making electrical incoming/out going connections with lugs/thimbles all as specified and directed.
Supplying & fixing MCCB, 3 pole, 125 Amps, 50Hz, 415 Volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having type DPX 160 fixed in distribution board, complete all as specified & directed.
S&F in repair MCB TPN 63 Amps ('C' series) having current rating 10 KA including making electrical incoming/out going connections with lugs/thimbles all as specifed and directed.
Disconnecting & taking up or down existing unserviceable submain wiring including aluminium/ copper conductor with conduits and M & L for provision of Sub main wiring with FR PVC insulated unsheathed 2X4 sqmm multistranded copper conductor cable 1100 V with 1X4 sqmm FR PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 20 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing etc complete all as specified and directed. NOTE :(i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface
Disconnecting & taking up or down existing unserviceable submain wiring including aluminium/ copper conductor with conduits and M & L for provision of Sub main wiring with FR PVC insulated unsheathed 2X10 sqmm multistranded copper conductor cable 1100 V with 1X10 sqmm FR PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 25 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing etc complete all as specified and directed. NOTE : (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of rating 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable size of MS strip, nuts, bolt and washer including taking down existing two pin and earth plug and socket complete complete all as specified and as directed.
Taking down carefully from existing place for ceiling fan/ Exhaust fan and removing to MES store yard Scraping, cleaning & painting with two coats of super enamelled paints (as approved by GE) greasing/oiling and refixing at site complete incl electric connection with three core flexible wire 1.5 sqmm all as specified and directed by Engineer-in-Charge.
Taking down carefully from existing place for re use geyser by disconnecting elect /water supply connection and refixing the same after civil work incl all elect /water supply connection connecting with suitable wire all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 20 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal, magnesium, salt etc & 50mm thick pre-cast RCC (1:2:4) type B-1 (Nominal mix) cover with reinforced with 8 mm dia TMT bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally with suitable steel handle and angle iron 40X40X6mm frame and chamber of PCC (1:3:6) type C-1 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, including taking down of existing earthing complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegetable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
S&F for LED mirror light fitting ( 2 feet) 1 x 10 watt batten type LED, complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F exhuast fan, steel body AC single phase 230v of size 450mm sweep heavy duty with blade, frame and louversall all as specified and directed.
Supply, laying , jointing & testing XLPE insulated,screened ,PVC bedded, galvanised steel strip or wire armoured, electirc power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 35 Sq mm 3.5 core including taking out of cable any type and capacity from trenches ,pole,road etc including necessary joints & bricks & removing form site complete all as specified and directed. Note : Excavation , earth work, sand cushioning for cable and cable protection cover shall be measured & paid under respective item. .
M &L for sand filling with clean, dry and sieved fine natural river sand in two portion, including gently punning around cables after the cables are laid, in trenches for cable protection complete all as specified and directed. (NOTE: Only punned thickness measured).
Supply & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Adhunik Builders
M/s Bijender Singh
NSC Projects Pvt. Ltd.
M/s Himgiri construction
Deepesh Electricals
ATUL CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .