Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAdmitted-Finance | ₹12.5 L | L1 | Admitted-Finance |
| 2 | L2₹12.8 L+₹38,043.20 (3.05%)Admitted-Finance 01 AGNI AUTOMATION AND SECURITY 01 KUNDAN BHAWAN SHIVAM VIHAR COLONY OPP KIET ENGG COLLEGE MURADNAGAR GHAZIABAD 201206 U P INDIA MURADNAGAR | GHAZIABAD | UTTAR PRADESH | 201206 | ₹12.8 L+₹38,043.20 (3.05%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | AGNI AUTOMATION AND SECURITY L2 | K.L Enterprises L1 |
|---|---|---|---|---|---|
| 1.01 | Making of all safety arrangements at site before start of work. | 1 | Job | 12,000 ₹14,160 Lowest | 13,690 ₹16,154.2 |
| 1.02 | Dismantling of old liquid rotor starter by opening its incoming and outgoing connection of the motor and opening/cutting the grouted angles nut/bolts etc. | 1 | Job | 44,500 ₹52,510 Lowest | 44,580 ₹52,604.4 |
| 1.03 | Shifting of the LRS from the installed location to outside the pump house using Hydra/crane as per requirement & instructions of the engineer in charge. | 1 | Job | 24,750 ₹29,205 | 24,550 ₹28,969 Lowest |
| 1.04 | Supply of the FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 3.3 KV supply, motor rating 275 KW Motor using Crane/Hydra as per site requirement and as per instructions of engineer in charge. Make Innovative/ Jayshree/L&T/Schneider Electric/DJB approved | 1 | Job | 8,20,000 ₹9,67,600 | 7,99,200 ₹9,43,056 Lowest |
| 1.05 | Work of installation of FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 415 Volt supply, motor rating 275 KW /3.3 KV Motor using Crane/Hydra as per site requirement and as per instructions of engineer in charge. Make Innovative | 1 | Job | 1,42,500 ₹1,68,150 | 1,24,590 ₹1,47,016.2 Lowest |
| 1.06 | Work of connection of the feedback from the main incoming panel and connection of feedback of ACB/MCCB the FCMA panel & Connection of the FCMA rotor controller with required lugs/thimbles /tape etc to complete the work. | 1 | Job | 20,000 ₹23,600 Lowest | 24,700 ₹29,146 |
| 1.07 | Complete testing of the Panel after installation. | 1 | Job | 24,500 ₹28,910 Lowest | 24,700 ₹29,146 |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
27 Mar 2026, 2:45 pmClosed
OFFICE OF THE EXECUTIVE ENGINEER (SDW)-VIII
OFFICE OF THE EXECUTIVE ENGINEER (SDW)-VIII
Replacement of existing LRS with Soft starters at Dwarka Sector 7 SPS
2026_DJB_288972_6
NIT NO.17 (2025-2026)EE(SDW)VIII
Open Tender
Miscellaneous Works
Works
60 days
OFFICE OF THE EXECUTIVE ENGINEER (SDW)-VIII
as per NIT conditions
2 documents required · 2 mandatory
₹500
services.sabpaisa.in
₹26,000
2 May 2026
20 Mar 2026
27 Mar 2026
20 Mar 2026
27 Mar 2026
20 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Making of all safety arrangements at site before start of work. | - | Job | - | - |
| 1.02 | Dismantling of old liquid rotor starter by opening its incoming and outgoing connection of the motor and opening/cutting the grouted angles nut/bolts etc. | - | Job | - | - |
| 1.03 | Shifting of the LRS from the installed location to outside the pump house using Hydra/crane as per requirement & instructions of the engineer in charge. | - | Job | - | - |
| 1.04 | Supply of the FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 3.3 KV supply, motor rating 275 KW Motor using Crane/Hydra as per site requirement and as per instructions of engineer in charge. Make Innovative/ Jayshree/L&T/Schneider Electric/DJB approved | - | Job | - | - |
| 1.05 | Work of installation of FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 415 Volt supply, motor rating 275 KW /3.3 KV Motor using Crane/Hydra as per site requirement and as per instructions of engineer in charge. Make Innovative | - | Job | - | - |
| 1.06 | Work of connection of the feedback from the main incoming panel and connection of feedback of ACB/MCCB the FCMA panel & Connection of the FCMA rotor controller with required lugs/thimbles /tape etc to complete the work. | - | Job | - | - |
| 1.07 | Complete testing of the Panel after installation. | - | Job | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.20 MB
BOQ_383703.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .