Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.1 L+₹2.3 L (5.01%)Rejected-Finance 2 FLAT NO 2 B GEETHANJALI CLASSIK APARTMENT 9TH CROSS KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.5 L+₹2.8 L (6.00%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹50.5 L+₹3.8 L (8.13%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹51.2 L+₹4.5 L (9.53%)Rejected-Finance 121004 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
24 Feb 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT OF CONDUIT DUCT FOR ELECTRICAL COMMUNICATION MEDIA CABLES MEDIUM HIGH BAY HANGER FITTINGS AIRFIELD LIGHTING AND CERTAIN MISC E M WORKS AT AF STN SULUR
2020_MES_321817_1
GE(AF)/SUL/Token/61 of 2019-2020
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
6 Mar 2020
4 Feb 2020
25 Feb 2020
4 Feb 2020
24 Feb 2020
18 Feb 2020
4 Feb 2020 - 17 Feb 2020
Amount
SCHEDULE A BOQ
Taking down existing AF Net cable /Electrical cable /Communication cable from wall / ceiling / floor for relaying .
DLP aluminium trunk of size 105 x 50 mm cat no 11100 of Legrand or equivalent of L&T or Siemens
Rigid cover of width 85 mm for DLP trunk of size 105 x 50 mm cat no 011111 of Legrand or equivalent of L&T or Siemens
Rigid cover of width 65 mm for DLP trunk of size 150 x 50 mm two compartment type cat no 2x011110 of Legrand or equivalent of L&T or Siemens
Cover joint for DLP trunk of size 105 x 50 mm cat no 011163 of Legrand or equivalent of L&T or Siemens
Trunking base joint for DLP trunk of size 105 x 50 mm cat no 011166 of Legrand or equivalent of L&T or Siemens
Clip-on partition for DLP trunk of size 150 x 50 mm Two compartment type cat no 011106 of Legrand or equivalent of L&T or Siemens
Dividers separation partition for DLP trunk of size 105 x 50 mm cat no 011108 of Legrand or equivalent of L&T or Siemens
End cap for DLP trunk of size 105 x 50 mm cat no 011158 of Legrand or equivalent of L&T or Siemens
External angles for DLP trunk of size 105 x 50 mm cat no 011232 of Legrand or equivalent of L&T or Siemens
Flat angles for DLP trunk of size 105 x 50 mm cat no 011243 of Legrand or equivalent of L&T or Siemens
Flat junction for DLP trunk of size 150 x 50 mm cat no 011251 of Legrand or equivalent of L&T or Siemens
Clip for DLP aluminium trunk of size 105 x 50 mm cat no 010682 of Legrand or equivalent of L&T or Siemens
Earth link for DLP trunk of size 105 x 50 mm cat no 011188 of Legrand or equivalent of L&T or Siemens
Supports for arteor 2 modules for cover 65 mm width cat no 011202 of Legrand or equivalent of L&T or Siemens
Supports for arteor 3 modules for cover 65 mm width cat no 011203 of Legrand or equivalent of L&T or Siemens
Supports for arteor 4 modules for cover 65 mm width cat no 011204 of Legrand or equivalent of L&T or Siemens
IP 65 polycarbonate MCCB distribution board of size 200 x 280 x 130 mm with inbuilt hinges, four pole, 125 amp breaking capacity 16 KA MCCB conforming to IEC-61439-1 complete with IP 65 polycarbonate window for easy operation of MCCB. The polycarbonate enclosure should be dust, water and all weather proof for outside mounting, flame retardant UL 94VO, UV resistant, glow wire test 960°, impact IK 08, Halogen free and ROHs complaint,, conforming to IEC 60529, including taking down existing one complete all as specified. Make :- L&T/ Schneider/ Hensel/ Grasp Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, RIGID 19/20 mm dia, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 22 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 22 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 22 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
S&F in replacement of all in one integrated solar street light of less than 12W with 2000 lumen and system lumen efficacy of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70. Make : Philips Cat No BRP 710 LED 20 series with Hy brid feature or equivalent in Wipro/ Bajaj. Note :- The unit rate is deemed to included for 6 mtr long MS/GI pipe of 50MM dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engr-in-Charge
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long MS/ GI pipe of 50mm dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor alongwith conduitshall be measured as one length including taking down existing one. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Replacement of convetional type boolard fitting with LED bollard light fittings suitable for 1x9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make /cat part No. CG cat no. LBLSN-10-CDL or Bajaj Cat Part No. BGBOS 600 9W LED /philips.
LED aviation obstruction light with IP 66 protection water clear poly carbonate UV stabilized dome neoprene rubber with bind spike with 302 Nos LED bulbs including necessary electric connections including 2.5 sqmm, 2 core, PVC copper cables fixed on wall with 20mm dia PVC conduit from DB to light fitting fixed in and including GI pipe 25mm dia 1 mtr long grouted with PCC complete/ binding with existing angle frame etc complete all as directed at site. Make : Bajaj Cat No - 110731 or equivalent in Wipro/ CG.
Indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4 feet (appx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm including taking town existing one complete all as specified and directed. Make : Philips CAt part NO.85395000 /Wipro cat part No. LL13-181-650 for rod and WIO921208 or equivalent in Bajaj
Notes :- (a) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved. (b) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (c) The contractor shall submit warranty certificate from manufacturer for minimum 02 year.
18 watt recess mounted sleek square downlighter enviornment friendly, new generation, energy saving with high power LED as light sources & clear glass inlcuding accessories including taking town existing one all as specified and directed by Engr-in-Charge. Make /Model : Philips cat part No.DN 295B LED16S-6500 PSU WH/Wipro/Syska Note : 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
High power LED street light fittings energy saving luminaire with lens , capacity 36 watt with system efficacy (lm/w) shall be 100 lumen per watt or more lumens per watt, total system lumen not less than 3600 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5000K TO 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% including taking down existing one complete all as specified. Make : Philips Cat No. BRP409 LED CW 036 MR FG S1 PSU GR or Equivalent of Bajaj/Wipro. Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Recess mounting powder coated luminaire white CRCA full glow LED ceiling lights indoor 2'x2' not less than 36watt, colour temperature white complete including taking down existing all as specified and directed. Make : Philips Cat No RC365BLED33-6500 PSU OD WH or equivalent in Hager/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing Capping : Modi/ Presto Plast/ Polycab Make of Wire : Plaza/ Polycab/ Havells Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 37 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 37 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 37 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Rigid, non-metallic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories complete all as specified and as directed
Integrated solar street light of less than 18W with 3000 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70 including taking down existing one all as directed. Make : Philips Cat No BRP 710 LED 30 series with Hy brid feature or equivalent in Wipro/ Bajaj. Note :- The unit rate is deemed to included for 6 mtr long MS/GI pipe of 50MM dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engr-in-Charge
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long MS/ GI pipe of 50mm dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
Lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 6 sqmm cable along with two run of 6 sqmm cable for earth conductor alongwith PVC casing capping shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
PVC casing capping of 50 mm (width) complete all as specified and directed.
4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned. Make : Philips Cat Part No BN308 LED20S 6500 L120 PSU WH or equivalent in Bajaj or schreder.
Note :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Replacement IP 65 polycarbonate MCCB distribution board with size 200 x 280 x 130 mm with inbuilt hinges, four pole, 63 amp breaking capacity 16 KA MCCB conforming to IEC-61439-1 complete with IP 65 polycarbonate window for easy operation of MCCB. The polycarbonate enclosure should be dust, water and all weather proof for outside mounting, flame retardant UL 94VO, UV resistant, glow wire test 960°, impact IK 08, Halogen free and ROHs complaint,, conforming to IEC 60529, complete all as specified. Make :- L&T/ Schneider/ Hensel/ Grasp Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
Excavation in trenches not exceeding 1.5m depth and not exceeding 1.5 mtr in wide in hard/dense soil and getting out.
Removing of excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Fly ash cable protection cover of size 23x11.5 x7.5cm including taking down existing bricks of any size.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 50 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Rigid, non-metallic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed.
S&F LED retrofit lamp 15W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj
All as per item No 57 above but LED retrofit lamp 12W
All as per item No 57 above but LED retrofit lamp 9W
All as per item No 57 above but LED retrofit lamp 7W
All as per item No 57 above but LED retrofit lamp 5W
IP 66 Pole Mounted street lighting Junction Box 160x240x120 mm made of Polycarbonate, supplied with 1 No. 6A 10KA SP MCB, 1 No. 63A 4P FR Polyamide color coded RYBN Terminals Block, 1 No. each of Earth & Neutral Terminal mounted on 35mm DIN channel and fitted inside Enclosure alongwith Pole Mounting bracket, pole clamp & hardware made of Stainless Steel 304. The Junction Box enclosure Cover should have inbuilt 2 nos Polycarbonate Hinges with SS 304 Hinge pin, for Cover not to detach from Base on opening and should be properly tightened to base with Polycarbonate screws having sealing gaskets of extruded silicon rubber. The Polycarbonate enclosure should have properties Flame Retardant UL94V0, UV, Glow Wire test 960 Deg C, Impact IK08, Halogen free & RoHS compliant, Glow Wire Test for 960⁰ C. Type test reports from NABL lab in India along with Polycarbonate manufacturer batch test certificate should be submitted. Make of junction box shall be as per make mentioned in list of makes in PS.
PVC casing capping of 25 mm (width) complete all as specified and directed.
PVC casing capping of 40 mm (width) complete all as specified and directed.
LED Highbay Light, 200 Watts with housing –IP65 and IK07, circular high pressure die cast aluminum housing and manufacture logo embossed on the housing and High transmittance tempered glass cover, Optics-Lens with lens plate having NB & WB Optics, system efficacy->115 lumens/watt, Xitanium driver – IP66 complying to IEC- 61347 – 2- 13 Certification like CE, ENEC, ROHS, with rated life of 50000Hrs for driver at TC-80 deg C along with all safety features –Thermal protection, voltage range is 90 - 295 Volt,surge protection 4 KV, protection against input over voltage<320 VAC for 48 Hrs, Driver failure rate<0.2% per 1 Khr @ TC 70-80 Deg C, driver efficiency -93% at Max Load, internal wiring –Teflon, SDCM<5, CCT-5700, CRI>80, THD<20 at Max load , Third harmonics <20%, PF>.95 fixed complete all as directed at site.(Make: Philips cat No:415P LED145S CW NB FG PSU GR S2 or eqvt LT/ Schreder Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Rigid, non-metallic, PVC conduit pipe, ISI marked, 40 mm bore, including bends, saddles, accessories complete all as specified and as directed.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 sq mm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Replacement of convetional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed.Make/cat part No. CG cat no. LPTO-40-CDL or Bajaj Cat Part No. BRIL 45 W LED NW /philips.
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Wire : Plaza/ Polycab/ Havells Make of Casing Capping : Polycab/Modi/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
One light point/fan/bell point controlled by one switch
All as per item No. 70 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 70 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 70 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Electronic fan regulator 230 volts, step type socket type, hum free 120 watt. Make : Havells / Schnieder/ crabtree
Integrated solar street light of less than 28W with 4500 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70 including taking down existing one all as directed. Make : Philips Cat No BRP 710 LED 45 series with Hy brid feature or equivalent in Wipro/ Bajaj. Note :- The unit rate is deemed to included for 6 mtr long MS/GI pipe of 50MM dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engr-in-Charge
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long GI pipe of 50mm dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
LED Flood Light luminaire of capacity 120 Watt,system lumen efficacy not less than 90 lumen per watt, total system lumens not less than 12000 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV, colour temp 5700 k to 6500k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,luminaire IP 65 Class -I including taking down existing one all as specified and directedMake : Bajaj Cat No. 169641 BARFEG 120W LED or Equivalent of Philips/wipro. Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make: Anchor/ cona/ Plaza.
Ultra bright 18 watt LED lamp 4 pin PL-L with very high efficacy suited for installation in existing 2G11 lamp holders including taking down existing one. Make :- Havells Cat Part No LHLDEJNEUL7Z018 or equivalent in philips.
Supply and replacement of 4 pin 11 watt CFL. Make CG or equivalent
Supply and replacement of 2 pin 18 watt CFL. Make CG or equivalent
Supply and replacement of 4 pin 36 watt CFL. Make CG or equivalent
DLP aluminium trunk of size 150 x 50 mm cat no 011102 of Legrand or equivalent of L&T or Siemens
Rigid cover of width 130 mm for DLP trunk of size 150 x 50 mm cat no 011112 of Legrand or equivalent of L&T or Siemens
End cap for DLP trunk of size 150 x 50 mm cat no 011160 of Legrand or equivalent of L&T or Siemens
External angles for DLP trunk of size 150 x 50 mm cat no 011234 of Legrand or equivalent of L&T or Siemens
Flat angles for DLP trunk of size 150 x 50 mm cat no 011245 of Legrand or equivalent of L&T or Siemens
Clip for DLP aluminium trunk of size 150 x 50 mm cat no 010682 of Legrand or equivalent of L&T or Siemens
Earth link for DLP trunk of size 150 x 50 mm cat no 011188 of Legrand or equivalent of L&T or Siemens
Supports for arteor 2 modules for cover 85 mm width cat no 011212 of Legrand or equivalent of L&T or Siemens
Supports for arteor 3 modules for cover 85 mm width cat no 011213 of Legrand or equivalent of L&T or Siemens
Cover joint for DLP trunk of size 150 x 50 mm cat no 011164 of Legrand or equivalent of L&T or Siemens
Trunking base joint for DLP trunk of size 150 x 50 mm cat no 011166 of Legrand or equivalent of L&T or Siemens
Dividers separation partition for DLP trunk of size 150 x 50 mm cat no 011108 of Legrand or equivalent of L&T or Siemens
Metal clad switch socket single pole and earth enclosure with two pin and earth plug with socket complete with on SPN 20 Amps, 230 Volts. Make : Cat Pt No 607841 of Legrand or equivalent of Schnieder (Multi -9) or Siemens/L&T (Hegar).
Supply and fixing on Pole/Wall Flood light fittings for use with LED lamps, 160watts, 240 Volt, with high quality lenses & reflector, 240 Volt, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-65 class of protection, complete with control gear and all accessories including lamp. Make :Bajaj Cat part No. 169642 BARFEG160WLED or equvalent Philips, Havells/Philip Cat Part No BVP1410LED172CWHENBFGS3x7.
Electronic modular fan regulator 230 volts, step type socket type, hum free 120 watt. Make : Havells / Schnieder
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 sq mm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Avon Plast/ Supreme/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
One light point/fan/bell point controlled by one switch
All as per item No. 101 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 101 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 101 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Switch piano flush type 15 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Shuttered socket outlet 3 pin 5 amps, flush type
Shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps
Modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular Socket, 6/16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular Bell push 6A 1 module.
Bell push, flush type, 5 amps.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
High power LED street light fittings energy saving luminaire with lens , capacity 20 watt with system efficacy (lm/w) not less than 90 lumens per watt, total system lumen not less than 2000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5000K TO 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% including taking down existing one complete all as specified.. Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent in Bajaj/Wipro. Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Cover joint for DLP trunk of size 150 x 50 mm Two compartment type cat no 011162 of Legrand or equivalent of L&T or Siemens
Dividers separation partition for DLP trunk of size 150 x 50 mm Two compartment type cat no 011106 of Legrand or equivalent of L&T or Siemens
Ceiling rose, surface type Bakelite 65x55mm 3 terminals.
Flat junction for DLP trunk of size 105 x 50 mm cat no 011251 of Legrand or equivalent of L&T or Siemens
Clip for DLP aluminium trunk of size 150 x 50 mm two compartment type cat no 010682 of Legrand or equivalent of L&T or Siemens
Supports for arteor 4 modules for cover 85 mm width cat no 011214 of Legrand or equivalent of L&T or Siemens
Replacement IP 65 polycarbonate MCCB distribution board with size 200 x 280 x 130 mm with inbuilt hinges, four pole, 100 amp breaking capacity 16 KA MCCB conforming to IEC-61439-1 complete with IP 65 polycarbonate window for easy operation of MCCB. The polycarbonate enclosure should be dust, water and all weather proof for outside mounting, flame retardant UL 94VO, UV resistant, glow wire test 960°, impact IK 08, Halogen free and ROHs complaint,, conforming to IEC 60529, complete all as specified. Make :- L&T/ Schneider/ Hensel/ Grasp Note :- The contractor shall submit test report from the manufacturer to comply with all requirements and specifications given in the contract.
Supply, installing and commissioning factory made CPRI tested, Outdoor type Nature Switch with intelligent lighting control providing independently ON at dark/cloudy atmosphere and switch OFF in normal atmosphere based on lux level of natural light for energy efficient lighting with attention free operation. The panel shall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick CRCA mild steel sheet, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. The scope of work also comprising of the following:-
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt Magnesium Sulphate (1 : 1: 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed. Note :- (a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Sreyas Enterprises
Arunachaleswara enterprises
NAVEEN ENTERPRISES
Neptune Engineers and Builders
ARCHANA CONSTRUCTION CO
T C KARUNANITHI
DANDU CONSTRUCTIONS
LAKSHMI ELECTRICAL ENTERPRISES
Ravees Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .