Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹90.0 LAccepted-AOC 143 ALLAHABADPUR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹93.5 L+₹3.5 L (3.88%)Rejected-Finance 302 RAYDIANT TOWER AMARABATI PATH GUWAHATI KAMRUP METRO ASSAM 781006 | KAMRUP METRO | ASSAM | 781006 | L2 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 3 | L3₹1.0 Cr+₹13.4 L (14.9%)Rejected-Finance 439 D DEFENCE COLONY JAJMAU KANPUR 208010 | KANPUR NAGAR | UTTAR PRADESH | 208010 | L3 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 4 | L4₹1.1 Cr+₹22.3 L (24.8%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110 075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L4 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 5 | L5₹1.2 Cr+₹25.4 L (28.3%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
Tender Value
₹98.5 L
EMD Value
₹1.7 L
Closing Date
22 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
PROVN OF CENTRAL MI ROOM AT SIGAR MIL STN UNDER GE 872 EWS
2025_MES_700797_1
84411/E8
Open Tender
Civil Works
Lump-sum
365 days
GE 872 EWS
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹1,000
GE 872 EWS
₹1.7 L
Yes
12 Jul 2025
10 Mar 2025
26 Apr 2025
10 Mar 2025
22 Apr 2025
1 Apr 2025
Amount
Total amount of Sch 'A' Part-I Building Works Note :- This schedule is not pre-priced by MES and the rate indicated as "Rs. 0.00" under column 6 signifies this fact only.
Soil investigation, Design, Fabrication and Construction of CENTRAL OF MI ROOM in RCC Framed Structure as per Arch Drg No. CWE/DIN/15/25 sheet No. 1/3 to 3/3 dated 20.01.2025 AND CWE/DIN/15/25 sheet No. 1/1 dated 20.01.2025 and specification given in Sch A Notes and Particular Specifications including complete RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. NOTE : Soil investigation will be measured and paid separately. (i) Size – As per Arch drawing (ii) Height – 320 CM (iii) Fdn – To be design as per SBC report with RCC framed construction. (iv) Plinth – Burnt Brick wk in CM 1:6 (v) DPC – 40 mm thick PCC 1:2:4 with WPC (vi) Super Structure – All RCC structure to be M25 design mix PCC blocks wk wall upto ceiling. (vii) Seismic Zone – Strengthening measures for Zone V (viii) Roof – RCC roof slab, (thickness as per design) (ix) Internal Plaster – Internal 15 mm thick in CM (1:6) (x) Flooring – Coloured vitrified tiles in all room, verandah & non skid ceramic tiles in toilet and bathroom over 15 mm thick screed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of 1:5:10. (xi) Dado/Skirting – Glazed ceramic tails over 10 mm thick cement screed in CM (1:3) up to lintel height. (xii) Joinery – Frames – Aluminium frame, shutter – Aluminium glazed shutter (TD Drg No CESZ/2015/TD/005 & 007 dt 05 Jan 2015) & PVC doors in toilet bathroom and Main entrance door of Toughened glass 12mm thick (minimum) with frostening and tinted as per requirement in double leaf with necessary fixing arrangement, lockes, floor springs, gaskit etc. (xiii) Joinery Window – Aluminium windows with grills (TD Drg No CESZ/2015/TD/005 & 007 dt 05 Jan 2015 (xiv) Steel Guard – Aluminium grill to windows (xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) (xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core. (xvii) Painting – Synthetic enamel paint on steel/wooden surface. (xviii) Finishes – Internal - 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer. External - 02 Coats of weather proof exterior emulsion over one coat of primer. (xix) Antitermite treatment - As per IS-6313 Part-II : 2001 (xx) Mosquito proofing - All external doors & Windows (xxi) 18mm thick granite over CM 1:3 for steps (xxii) Sanatory Fitting – Vitreous China EWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2 & 2/2 and TD Drg No CESZ/TD-31 Sheet No 1/2 & 2/2). (xxiii) Mosquito Proofing – All external Door and window.
NOTE: Schedule ‘A’ Part II to IX are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured.
Total amount of Sch ‘A’ Part II (Excavation and Earthworks)
Total amount of Sch ‘A’ Part III (Internal Electrification)
Total amount of Sch ‘A’ Part IV (Internal Water supply)
Total amount of Sch ‘A’ Part V (Path with interlocking paver block)
Total amount of Sch ‘A’ Part VI (Sewage Disposal)
Total amount of Sch ‘A’ Part VII (Area Drainage)
Total amount of Sch ‘A’ Part VIII (External Water Supply)
Total amount of Sch ‘A’ Part IX (External Electrification)
SCH 'A PART X (Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
M & L for boring 100 mm dia hole in all kind of soil upto maximum depth 10 meter or up to refuse (N=100) whichever meet earlier including collection of undisturbed sample from cohesive soil only conducting standard penitration test at 12 meter and 1.5 meter interval alternatively as per relevant IS code complete all as directed.
Completion of field work & lab test result and submission of report in Per Job quadruplicate suggesting depth of foundation type of fundation and safe bearing capacity with CD-1 (one) copy complete all as specified and directed.
Supply, installation, testing and commissioning factory made LT feeder pillar box Outdoor type suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 400 Amps for phases and neutral, install on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and painted with two coats of syntheitc enameled paint over a coat of red oxide primer and made out of 3.15mm CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50 mm lock make Navtal/Harrison and including grouting of panel with necessary PCC work icomplete all as specified. The scope of work includes the following accessories with ciruit breakers :- Incoming : - (i) MCCB 4 pole 16 kA,415 Volts,3 phase 63 Amps - 01 Nos (ii) Digital Multi function meter showing :- Volt meter 0 to 500 Volts, Amp meter 0 to 200 Amps – 01 Nos (iii) Indicating lamp LED type one set in incoming phases. (iv) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs. (v) Connection from MCCB to Busbar shall be of solid Aluminium conductor. (vi) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable. Outgoing :- (i) MCCB 4 pole 16 kA,415 Volts, 3 phase 40 Amps - 03 Nos (ii) MCB SPN, 240V, 10 KA, 32 Amps - 03 Nos
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primercomplete all as specified and as directed.
M&L for GI bracket fabricated out of light grade GI Tubing of 32 mm dia, 1.5 mtr long of one sided Arm type and along with 02 sets of suitable size of clamps and nut & bolts to fix the bracket on steel tubular pole and inclusive of one primer coat, one under coar and one finishing coat of paint (synthetic enamel) complete all as specified and directed.
S&F PVC insulated FRLS copper conductor Wire 1.0 Sqmm, 3 Core, multistranded cable for Providing Connection from Street Light Fitting to Overhead Line/ Junction Box complete all as specified and as directed.
Supply and installation of Wall mounted split units indoor/outdoor complete with cordless remote control unit and with in built airioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and direced.
S & F Voltage stabilizer for automatic operation, air cooled indoor type & designed for input variation between up to 140 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and direced.
S & F Exhaust fan made of study engineering plastic complete wth louvers shtter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250mm connecting cable of suitable size upto ceiling rose complete all as specified and directed.
S & F MCB distribution board, TPN 4 way, 415 Volts AC, double door type of sheet steel phosphotised powder painted with 200 Amps, neutral bars, earth bar all as specified and directed.
S & F MCB TPN 63 Amps, 415 Volts, 10 KS, 'C' Series complete all as specified and directed.
Shiva Soltronics Private Limited (BID ID -3278653)
Anand Construction (BID ID -3282394)
The new hut furnitures (BID ID -3282276)
V r traders (BID ID -3282258)
R K CONTRACTOR AND SUPPLIERS (BID ID -3282121)
M K Engineers and Contractors (BID ID -3282974)
M/s Vimal Traders (BID ID -3285543)
M/s Vatsh Raj and co (BID ID -3282331)
M/S S.B. Singh and Sons (BID ID -3282341)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .