Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹29.4 L+₹3.6 L (13.9%)Rejected-AOC | L2 | Rejected-AOC higher rate | |
| 3 | L3₹29.8 L+₹4.0 L (15.6%)Rejected-AOC RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | L3 | Rejected-AOC higher rate | |
| 4 | L4₹35.6 L+₹9.8 L (37.9%)Rejected-AOC RZ F1 104 MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-AOC higher rate |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
27 May 2022, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI SP MARG NEAR ABHM NEW DELHI-21
PROVISION OF HARD STANDING UG SUMP AND DRAINAGE AT PEREIRA ENCLAVE AND SPECIAL REPAIRS TO TOILETS AND GALLEY IN VARIDHI AT NOM VARUNA UNDER GE NEW DELHI
2022_MES_520937_1
GE/ND-11/2022-23
Open Tender
Civil Works
Works
180 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹62,000
Yes
22 Aug 2022
29 Apr 2022
30 May 2022
29 Apr 2022
27 May 2022
13 May 2022
Amount
Surface Excavation not exc 30 cm deep and average 15 cm deep and getting out hard and dense soli complete all as specified and directed.
Rolling and consolidating formation surface with power roller exc 8 tonne and not exc 12 tonne complete all as specified and directed.
M&L for soling 150 mm thick with broken boulders quarried stone inner stacks filled surface formed and rolled and consolidated to required gradient complete all as specified. (Note:- Rolling and consolidation shall be measured and paid separately)
Rolling on broken boulder or quarried stone not exc 15 cm thick with power roller exc 8 tonne and not exc 12 tonne complete all as specified and directed.
M&L for 150 mm thick Cement concrete type C2 1:2:4 (40mm graded stone aggregate) as in sub base of concrete complete all as specified and directed.
M&L for cement concrete work 200 mm thick in pavement/hardstanding of flexural strength 40 Kg /Sqcm in field using 400 kg of cement per cum of concrete, thick of conc 25 cm or less complete all as specified and directed.
Vibrating on concrete surface for consolidation with using plate vibrator as per direction of Engr-in-Charge complete all as specified and directed.
Finishing surface of concrete roads by brooming complete all as specified and directed.
Forming 12 mm thick expansion 200 mm slab joint filled with pre formed bituminous filler and top 30 mm primed and sealed with sealing compound Grade 'A' complete all as specified and directed.
Removing excavated material exceeding 250 mtr and not exc 500 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Formwork to sides of concrete foundations, bases of sides and soffits or sides of concrete roads/pavements if any complete all as specified and directed.
Demolition of cement concrete unreinforced in any description in any position not otherwise provided for complete all as specified and directed.
Excavation over areas not exc 1.5 deep and getting out soft/loose soil complete all as specified and directed.
M&L for PCC 1:4:8 type C2 (40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for RCC M-30 conc for base complete all as specified and directed
RCC M-30 for wall including jointing kit complete all as specified and directed
RCC M-30 for slabs supported walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and slabs and in shelves and complete all as specified and directed
M&L for form work for sides of base concrete flat surface complete all as specified and directed
M&L for form work for sides of wall concrete flat surface complete all as specified and directed
M&L for form work for suspended slabs flat surface complete all as specified and directed
M&L for mild steel TMT bars 10 mm dia and over cut to length or bent to shape required cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming complete all as specified and directed.
Returning and filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil etc complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing out of defence land at a level not exc 1.5 m above the starting point complete all as specified and directed.
M&L for hard core of size 40 to 63 mm graded stone aggregate complete all as specified and directed
M&L for 75 mm thick PCC 1:3:6 type C2 (40 mm graded aggregate) as in plinth protection complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
Supply only of polythene film for laying of under the RCC base complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces finished even and smooth complete all as specified and directed. complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (20 mm graded aggregate) in mass conc on roof of any thickness, benching, coping including recron fibre/Poly propane fibre 125 Grm per bag of cement complete all as specified and directed. (recron fibre shall be measured and paid separately)
S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars;, staging, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, steel sheets for shutters and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
Preparation new steel surface of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply, laying, jointing & testing GI tubing medium grade in trenches with all fittings of size 40 mm dia complete all as specified and directed
Supply, laying, jointing & testing GI tubing medium grade in trenches with all fittings of size 25 mm dia complete all as specified and directed
Supply and fixing gate valve 40 mm bore with fittings complete all as specified and directed.
Supply and fixing Ball valves 25 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed
Supply, installation , testing and commissioning of self priming electric driven monoblock pump of capacity 2.0 HP with water head of 6 - 32 meter , single phase , voltage range 180-240V complete all as specified and directed
Supply and fixing DOL Starter suitable for 2 HP monoblock pump complete all as specified and directed
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm ,3 core, 1100 Volts grade complete all as specified and directed
Taking down carefully old point wiring with aluminium/ copper conductor (Light / Fan/ Socket/ power Point ) complete including fittings such as ceiling rose, pendent holders, regulators and socket point etc and making good the disturbed surface & wall/ floor complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed multi-stranded, single core, FRLS type, copper conductor cable of size 1.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi-stranded, single core, FRLS type, copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC concealed rigid non-metallic conduit medium grade in floor/wall and its accessories including provision of new galvanised modular concealed box with suitable back & front plate for housing the modular switches, sockets & fan regulators for the following:- Note:- (i) Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate.
(a) One light/fan/exhaust fan point controlled by one nos, one way switch.
(b) One three pin 5 Amp socket outlet point controlled by one no, one way switch on independent board
M&L for point wiring with PVC insulated unsheathed multi-stranded, single core, FRLS type, copper conductor cable of size 2.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi-stranded, single core, FRLS type, copper conductor cable of size 2.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC concealed rigid non-metallic conduit medium grade in floor/wall and its accessories including provision of new galvanised modular concealed box with suitable back & front plate for housing the modular switches, sockets etc.
S&F in replacement modular switch flush type 6 Amp, SP, one way 230 volts AC complete all as specified and as directed.
S&F in replacement modular switch flush type 16 Amp, SP, one way 230 volts AC complete all as specified and as directed.
S&F in replacement modular socket outlet 5 pin 6 Amp, 230 volts AC complete all as specified and as directed.
S&F in replacement modular socket outlet 6 pin 16 Amp, 230 volts AC complete all as specified and as directed.
S&F in replacement of ceiling rose 3 terminal / PVC/ Polycarbonate, insulated body ISI Marked.
S&F LED Tube Light of 20/22 Watt 230Volt (size 4 ft) , suspended aluminium extruded linear lighting luminaire complete with LED Tube Light 20 Watt & all accessories internally prewired including connecting up with three core sheathed flexible copper conductor cable of suitable size complete all as specified. Make: Philips/Havells/CG
S&F in LED Tube light fitting 10 watt ( 2 ft ), 230 Volt AC complete including connecting up with three core twisted flexible copper conductor cable all as specified. Make: Philips/Havells/CG
Supply and fixing Exhaust Fan 450 mm Sweep, 240 Volt, AC 50 HZ , Metal body, heavy duty including louvers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement mortar complete all as specified and directed.
Disconnecting mains connection and taking out old sub main wiring two single core 4/6sq mm and one single core 4/6 sq mm aluminium conductor cable from the concealed conduit from the wall or ceiling and making good to surface.
M&L in replacement of submain wiring with FRLS PVC insulated unsheathed copper conductor multi stranded 1100V grade heavy duty 2 x 10 sqmm complete drawn in new PVC concealed conduit and its accessories along with 1x 10 Sqmm PVC insulated unsheathed copper conductor multi stranded cable for continuous earth wire and duly connected to common earth dolly all as specified and directed (The specified runs of single core cables and specified runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one run length). MAKE : Havells/Polycab/RR.
Disconnecting electrical connection and taking out old distribution board 8/12 way SPN complete all as specified and directed
S&F factory made sheet steel distribution boards, double door, SPN 12 way, concealed type, 240 volts AC with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified.
Supply and fixing MCB, 240V 10KA 'C' curve , of following poles and current carrying capacity in the MCB DB complete with connection testing. :-
(a) MCB SP 6 to 32 Amps
(b) MCB SPN 32 Amps
(c) MCB SP 40 Amps
Supply and fixing MCCB, 4 pole, 415 volt of capacity 160-200 amp, breaking capacity not less than 36 KA , Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer including taking down of old unsv. MCCBs etc.complete all as specified and directed by Engr-in-Charge Make : Legrand cat part No 5078 90 or equivalent Make : Legrand/ Schneider/L&T.
S&F in replacement of factory made load line DB's double door made out of 2.15 CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TPN 160-200 Amp,36 KA as incomer & MCB SP 40 Amp as out going including taking down of old unsv. MCCBs etc. complete all as specified. MAKE:-Legrand/Havells/Indoasian.
DEV CONSTRUCTION
MRITUNJYA ASSOCIATES
Ex Serviceman Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .