| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.8 L+₹1.6 L (8.60%)Rejected-Finance | L2 | Rejected-Finance Higher bid value. | |
| 3 | L3₹21.0 L+₹1.8 L (9.26%)Rejected-Finance | L3 | Rejected-Finance Higher bid value. | |
| 4 | L4₹21.9 L+₹2.7 L (14.0%)Rejected-Finance | L4 | Rejected-Finance Higher bid value. | |
| 5 | L5₹22.0 L+₹2.8 L (14.5%)Rejected-Finance | L5 | Rejected-Finance Higher bid value. |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
22 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Gangtok
GE Gangtok ,New Military station, Gangtok 737102
REPAIR MAINT OF LT EM INFRASTRUCTURE AT OLD CANTT INCLUDING MS 02 TO MS 13 AREA UNDER GE GANGTOK
2022_MES_561168_2
8055AE8
Open Tender
Electrical and Maintenance Works
Works
180 days
Gangtok
Class E category bi
8 documents required · 8 mandatory
₹500
Garrison Engineer Gangtok
₹36,000
Yes
7 Jan 2023
6 Dec 2022
24 Dec 2022
6 Dec 2022
22 Dec 2022
15 Dec 2022
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for taking out/ laying of under ground cables etc and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in hard/dense soil complete all as specified and as directed
Removal of surplus excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. of size 50 mm outer dia complete all as specified and as directed by the Engr-in-Charge.
Taking out old unserviceable, burnt, punctured aluminium conductor cable LT, PVC/XLPE, 1100 volts grade, of cross sectional area upto 16 Sqmm all as specified and directed.
Supply and laying in trenches/through pipes or bare in road crossing/paths/drains/ducts/floors/along poles/walls/ceilling/equipments etc. Cable under ground, heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area, including taking out old u/s cable and remove from site all as specified and directed by the Engr-in-charge:- (a) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule. (b) The rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes
35 Sqmm 4 Core
25 Sqmm 4 Core
16 Sqmm 4 Core
10 Sqmm 4 Core
16 Sqmm 2 Core
10 Sqmm 2 Core
6 Sqmm 2 Core
M&L for taking out faulty UG cable cutting faulty end, supplying and making straight through joint with heat shrinkable kit outdoor including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV volts grade complete of following cross ectional area 25 to 50 Sqmm 3.5/4 core (Note : Excavation & earth work, DWC pipe for protection if necessary will be measured and paid separately)
Taking out old unserviceable, GI tubing of any size upto 80 mm bore from the excavated trenches, ducts, floors, along poles/ walls/ equipments, road crossing/drains/ paths etc all as specified and directed by the Engineer-in-charge.
Supply and laying in trenches/under roads/ crossings are fixed to wall/pole, GI tubing light grade of size 50mm dia for protection of UG cables :- Payment for excavation and earth work shall be paid for separately under relevant items of schedule.
M&L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in complete including finishing the surfaces by providing cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) upto 20cm depth, finishing to a uniform smooth surface to match the existing surface complete all as specified and directed. Note:- (a) GI pipes shall be measured and paid separately. (b) Any damages made/caused to the HT/LT cables, water supply pipelines, OFC cables etc during the excavation works shall be made good by the contr as per original and to the entire satisfaction of Engr-in-charge and GE cost of the same is deemed to be included in the unit quoted rates.
Supply, fix and test in replacement of LED street light fitting of capacity 60 watts, CRI>70, power factor >0.95, colour tempreture 5700k, luminous output, IP-66 protection including electronic driver (SMPS based constant current supply with lower THD, output open/shot circuit protection, surge voltage protection etc) unit suitable for working voltage 140-240 V AC, 50 Hz, pressure die cast aluminum housing and finishing epoxy power coated grey colour after phosphor chormate treatment with all accessories, lamp bracket with impact and corrosion resistant and connecting up complete including fixing with suitable bracket, taking down old unserviceable one all as specified and directed.
S&F loop in loop junction box of internal dimension 130 x 180 x 77mm made out of polycarbonate and locking arrangement incl 6 AMPs MCB - 1 No 20 Amps rated 4 way connectors for 3 Phase and neutral incoming/out going mounted in the box, fixing on steel tubular poles including necessary clamps, suitable glands, lugs and GI nut and bolts including taking down old unserviceable junction box complete all as specified and directed . Make : Hensel Cat No : DK 1010G or Sintex/OBO
S&F in repairs rigid non-metalic PVC conduits of external dia 20mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends with aluminium clamp, bolt, nuts etc for fixing including taking down old unserviceable conduits complete all as specified and directed.
S&F in replacement PVC insulated flexible multicore round copper conductor cable of size 3 core 1.5 Sqmm including necessary end connector incl taking down unserviceable cable all as specified and directed. Make : Havells/Finolex/Polycab.
DHARMINDER SINGH
KAMLESH ENTERPRISE
BIJAY MITTAL
M/S ANIL KUMAR THAKUR
GEETA CONSTRUCTION
KARMA SHERPA
NISHA CONSTRUCTIONS
MAHENDRA KHAWAS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .