Loading…
Loading…
Tender ID
Tender Value
₹2.8 L
EMD Value
₹4,000
Closing Date
23 Mar 2026, 1:00 pmClosed
SE ETC Mathura
132 KV S/S Aurangabad Mathura
Work of Erection of 01 Nos 33 KV New Cantt Bay at 132 KV S/S Aurangabad under ETD Mathura
2025_UPTCL_1099195_2
ET-55/ETC(M)/25-26
Open Tender
Electrical Works
Lump-sum
90 days
Under ETC Mathura
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ATT ETC Mathura
₹4,000
5 Mar 2026
5 Mar 2026
24 Mar 2026
5 Mar 2026
23 Mar 2026
5 Mar 2026
Erection-
Erection of following equipments as per Instruction manual of various equipments and technical specifications including shifting of material/equipment from store to erection site including all other associated work to complete the job satisfactorily as per direction of supervising engineer.
33 KV VCB
33 KV Bus Isolators
33 KV line isolator
Junction Box of CT
Erection of 33 KV Simplex type Tripple feeder control & Relay Panel
Erection of Main and auxiliary structure consisting of columns, beams, peaks, masts etc. and auxiliary structure required for installation of Isolators, C.Ts. P.Ts., CVTs, L.As. and all other equipments. The job consists of shifting of all material i.e. structure parts, nuts, bolts, washers etc. from store to site of erection. erection of structure as per relevant drawing and practices using flat and spring washer with each bolt. Matching of holes, cutting matching of members if required shall also be done by the contractor without any extra cost to complete the work satisfactorily. All material to be erected shall be supplied by UPPTCL free of cost but all men, material and T&P required for satisfactorily completion of work shall be arranged by the contractor at his own cost including all other associated work to complete the job satisfactorily as per direction of supervising engineer.(appx. 3 MT)
ABL Structure
ALP Structure
CCM/ CGM Structure
CPM/ YMM Structure
Interconnection work between 33 kv main bus to bus isolator and bus isolator to 33 KV VCB and 33 KV VCB to 33 KV CT to PT and 33 KV CT to Line Isolator And 33 kv line isolator to 33 kv transfer bus isolator 33 kv Transfer bus isolator to 33 kv Transfer bus, with single/double by Panther Conductor including cutting laying, fixing and proper tightening with the help of skilled labour & T&P including all other associated work to complete the job satisfactorily as per direction of supervising engineer.
Laying of flowing sizes of control cable in the cable trench from various equipment to control and relay pane, marshalling boxes etc. from switch yard as per cable schedule, its saddling at every 750mm distance with M.S. saddles of size 25X3mm. Size including carriage of cable drums from store to laying site and shifting back to store and all other associated work to complete the job satisfactorily as per direction of supervising engineer.
6X2.5 Sq. mm
4X2.5 Sq. mm
2X2.5 Sq. mm
Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or box wherever required, supply and fixing of cable glands of appropriate size, supply and providing ferrules and Nos. for each core. (The rates of termination of Control cable include the all cores of cable at one end with lug) including all other associated work to complete the job satisfactorily as per direction of supervising engineer.
6X2.5 Sq. mm (each end)
4X2.5 Sq. mm (each end)
2X2.5 Sq. mm (each end)
Cutting straightening, bending laying 600 mm below in side ground and above ground of with 50X6 mm size of M.S. Flat for earthing of main structure, Auxiliary structure, C.T, C.B, B.I, L.I, with by 50x6 MS. Round with newly laid earth mat ‘x’ & ‘y’ axis below 600 mm ground and above by excavation of trenches its back filling, straightening, cutting, bending work also includes painting of M.S earth ship above ground level with one coat of red oxide and two coat of bus green enameled paint, and below ground each earth point raising from main earthmat ‘x’ & ‘y’ axis should be painted with bitumen black Japan paint and all other associated work as required to complete the work satisfactorily as per direction of supervising engineer. (excluding the cost of M.S Flat).
Preparation of Inter connection diagram and cable schedule as per drawing to complete above job for C&R panel and circuit breaker
Providing and fixing new generation energy saving and environment friendly long life versatile pressure die cast aluminium out door high beam flood light with high power 120W LEDs as light source and exclusively design poly carbonate cover satisfying IP65 standard alongwith electronic driver and complete fitting including GI pipe, clamp for round pole or GI structure, suitable for 220 V AC supply make CGL/Havells/Phillips and providing and fixing of junction box of 16 SWG Fiber sheet size 150X150X200 mm for above light on bottom of main structure or pole with the help of clamps junction box contain 01 No., 10Amp single pole MCB (L&T/HavellsSchneider make), 01 No. link and cable gland etc, as per specification and laying, dressing and termination of control cable for the light with the help of clamps vertically on the gantry and all other associated to complete the work.
Providing and fixing of retro reflective sign board of size 3ftx2ft made out of 2mm thick aluminum sheet, face to fully covered with 3M DG cube retro reflective sheet of green colour. The letters and symbols shall be computer cut and in white colour. Board is to be supplied along with the back support from of size 35x35x5mm & two legs for grouting. Backside of aluminum sheet shall be painted with stove enamel black paint for new 33 KV New Cantt Bay. Language for writing will be provided by the department (UPPTCL).
Transpotation-
Safely Carriage of any other material required for bay construction from any sub station store under ETD, Mathura to 132 KV S/S Aurangabad, Mathura.
Supply-
Supply of hardware Accessories
Supply of P.G. clamp made of LM-6 alloy along with Galv. Nut. Bolt & washer suitable for Panther to Panther conductor
Supply of tinned copper bond size 16x450 mm long made of 12 mm multi stranded rope type 450 mm long should be joined together and cramped with copper lug (20 mm hole ) on both ends as per sample
Supply of P.G. clamp made of LM-6 alloy along with Galv. Nut. Bolt & washer suitable for Zebra to Panther conductor
Supply of MS Flat
50X6 Sq.mm
25X6 Sq.mm
Portable AFFF mechanical foam type fire extinguisher complete with intial charge hose pipe and all other accessories and fittings as per IS 1024 Trolley/wheel mounted 45/50 liter cpapcity
Dry chemical powder type fire exitnguisher of 4.5 Kg capacity conforming with IS 2171/1985
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_2088757.xls
BOQ • 0.30 MB
NITFR.pdf
Tender Documents • 0.98 MB
lextr1.pdf
PDF • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .