Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | ₹33.3 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹33.8 L+₹45,878.91 (1.38%)Rejected-Finance | ₹33.8 L+₹45,878.91 (1.38%) | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹37.3 L+₹4.0 L (12.1%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | ₹37.3 L+₹4.0 L (12.1%) | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹43.9 L+₹10.5 L (31.6%)Rejected-Finance | ₹43.9 L+₹10.5 L (31.6%) | L4 | Rejected-Finance Not lowest bidder |
| 5 | L5₹44.4 L+₹11.0 L (33.2%)Rejected-Finance | ₹44.4 L+₹11.0 L (33.2%) | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹36.7 L
EMD Value
₹73,400
Closing Date
14 Sept 2020, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Special repair / replacement of LT OH line into underground cable and certain sanctioned works under GE (Army) Suratgarh at Suratgarh Mil Stn
2020_MES_369979_1
GE (A) SOG - 34/20-21
Open Tender
Civil Works
Item Rate
210 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE ARMY SURATGARH
₹73,400
Yes
29 Oct 2020
17 Aug 2020
16 Sept 2020
17 Aug 2020
14 Sept 2020
31 Aug 2020
Amount
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Dismantling existing unserviceable cross-arms of M.S. channel or angle sections etc. of any size and type complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down insulators of any type and size complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .
Suppyling, installing, testing and commissioning of factory made outdoor type bus bar chamber having MCCB 4 pole, 415 volts, 160 Amps, 25 KA of suitable size for operation on 415 volts, 3 phase, 4 wire 50Hz, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with hinges and locking arrangements etc suitables to accomodate the 160 Amps aluminium bus bar fixed horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators duly connected with 160 Amps MCCB including provision for taking out incoming and outgoing cable detacheable plate at bottom for cable entry and making six Nos hole in each bus bar including with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer-in-charge. Make of MCCB - ABB ordering code No 1SDA067410R1 / L&T cat part No CM090634OOMO / Schnieder Cat part No LV430320
All as per item No 6 above but MCCB 100 Amps, 4 pole, 25 KA, 415 volts and 100 Amps aluminium bus bar Make of MCCB - ABB ordering code No 1SDA067406R1 / L&T cat part No CM90681OOLOOG / Schnieder
All as per item No 6 above but MCCB 63 Amps, 4 pole, 25 KA, 415 volts and 63 Amps aluminium bus bar Make of MCCB - ABB ordering code No 1SDA067404R1 / L&T cat part No CM91712OOHOOG / Schnieder
Supplying, installing, testing and commissioning of thermoplastic polycarbonate IP 65 outdoor type in accordance with EN 60 529 (dust proof, weather proof & water proof) power distribution board of suitable dimension as per engineer practice, shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extingushing, UV Resistant, silica and halogen free recyclable material, glow wire tested at 960⁰C in accordance with IEC 60 695-2-11. type tasted as per IEC 61 439-1. total insulated with system. The manufacturer of board / panel shall submit a copy of ASTA certification by CPRI for the Degree of ingress protection in accordance with IEC 60529. The gasket material shall be polyurethane while the gasket shall be internally embedded including provision for taking incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable , danger board, detachable plate at bottom for cable entry etc. with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs. The manufacturer of board / panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 61 439-1. The report shall have mention of following tests performed and passed out satisfactorily:- (i) Tempreture rise. (ii) Dielectric properties (iii) Short circuit withstand current - rated peak & short time with stand current and rated conditional short circuit current. (iv) Efffectiveness of protective circuits (v) Clearance & Creepage distance (vi) Degree of protection (vii) Mechanical operation
Item No 9 Contd/-.......... The impact strength of polycarbonate enclosure / boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B-1 as in floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accessories :- Incoming (a) 500 Amps copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 320 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA054436R1 / L&T cat part No CM98401OOROOG / Schnieder Outgoing (a) MCCB 160 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067410R1 / L&T cat part No CM090634OOMO / Schnieder Cat part No LV430320 (b) MCB 40 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve - 08 Nos Make :- ABB order code No 1SYS273112R0404 / L&T/ Schneider (c) indicator lamp LED type complete - 01 Set (d) Internal all links & control cable and indicators of copper conductor or solid aluminium bus bar of adequate capacity - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
All as per item No 9 above but comprising of following accessories:- Incoming (a) 250 Amps copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 160 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067410R1 / L&T cat part No CM090634OOMO / Schnieder Cat part No LV430320 Outgoing (a) MCB 40 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve - 08 Nos Make :- ABB order code No 1SYS273112R0404 / L&T/ Schneider (b) indicator lamp LED type complete - 01 Set (c) Internal all links & control cable and indicators of copper conductor or solid aluminium bus bar of adequate capacity - set of three
All as per item No 9 above but comprising of following accessories:- Incoming (a) 150 Amps copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067406R1 / L&T cat part No CM90681OOLOOG / Schnieder Outgoing (a) MCB 40 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve - 05 Nos Make :- ABB order code No 1SYS273112R0404 / L&T/ Schneider (b) Indicator lamp LED type complete - 01 Set (c) Internal all links & control cable and indicators of copper conductor or solid aluminium bus bar of adequate capacity - set of three
All as per item No 9 above but including taking out old unserviceable LT panel with comprising of following accessories:- Incoming (a) 600 Amps copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 400 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA054437R1 / L&T cat part No CM98403OOROOG / Schnieder Outgoing (a) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 05 Nos Make - ABB ordering code No 1SDA067406R1 / L&T cat part No CM90681OOLOOG / Schnieder (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067404R1 / L&T cat part No CM91712OOHOOG / Schnieder (c) CTs 400/5 Amps - 01 Set (set of three) (d) Indicator lamp LED type complete - 01 Set (e) Internal all links & control cable and indicators of copper conductor or solid aluminium bus bar of adequate capacity - set of three
All as per item No 9 above but including taking out old unserviceable LT panel with comprising of following accessories:- Incoming (a) 300 Amps copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 200 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067016R1 / L&T cat part No CM92109OON1OG / Schnieder Outgoing (a) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 02 Nos Make - ABB ordering code No 1SDA067406R1 / L&T cat part No CM90681OOLOOG / Schnieder (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 02 No Make - ABB ordering code No 1SDA067404R1 / L&T cat part No CM91712OOHOOG / Schnieder (c) CTs 200/5 Amps - 01 Set (set of three) (d) Indicator lamp LED type complete - 01 Set (e) Internal all links & control cable and indicators of copper conductor or solid aluminium bus bar of adequate capacity - set of three
S&F street light pole box of size not less then 260x210x120mm, made of high quality thermo plastic polycarbonate enclosure tested for degree of protection IP-67 in accordance with EN60529 and glow wire test at 960 degree C as per IEC 60695-2-12, weather proof, dust proof, water proof, chemical, acid corrosion, impact, insulated & shock proof, with hinged transparent cover available with internally embedded gasket (PUR) including MCB SP 6 Amps 01 No premoulded knockout lower sides. The box fitted with 10 sqmm stud type terminal - 04 Nos including Elimex stud type TB 4 Nos. Make :- Hensal / Hanson Note :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.
All as per item No 14 above but including taking down old cable junction box
S&F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
S&F in replacement PVC insulated stranded copper conductor, 1100 volts grade, 1.5sqmm 3 core size of ISI marked connection from security light to pole box complete all as specified and directed by Engineer-in-Charge.
S&F isolator 32 Amps double pole suitable for 240 Volt AC supply complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 406500 or equivalent in/ Havells / Schneider
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 or equivalent in L & T / Havells / Schneider
S&F street light bracket made out of 32mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F LED flood light of 150 watt with high pressure die cast housing with lens with lument output 6000K complete (including LED, drive and internally prewired) with on board 5 KV surge protection with 10 KV external SPD. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 100 lumens per watt and FRLSH cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked for light to ceiling rose complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Syska Cat part No SSK-BLS-N-150W / Wipro cat part No LF20-192-060-57-G2 /Crompton Cat part No LFLN-150-CDL/60-M / Philips
Supply, fixing and testing LED Street / Security light fitting of 45 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Syska Cat part No. SSK-SLF-F-45W-WL / Crompton Cat Part No LSTV-45-CDL / Havells Cat part No ENDURAPEARL NEOSL45WLED757SASYTOPC / Wipro Cat Part No LR02-501-XXX-57-XX / Philips
All as per Srl item No 22 above but LED street / security light of 60 watt Make :- Syska Cat part No. SSK-SLF-F-60W-WL / Crompton Cat Part No LSTP-60-CDL-M / Havells Cat part No. ENDURAPEARLNEOSL60WLED757PASYTOPC / Wipro cat part No LR02-671-XXX-57-G2 or equivalent in philips Notes for srl Item No 22 & 23 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F Single phase automatic automatic street light switch suitable for 3 KW load complete with two numbers Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with one number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 01 No, outgoing MCBs single pole - 01 No of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor (one service & one stand by) should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a pole / wall mountable enclosure made of Rust proof, Electric shock proof, termite proof and FR grade confirming to IP66 complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD (Swadeep 02EC3KW1P) / Siemens / Legrand / Indo Asian
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engineer-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
All as per item No 25 above but including taking down old earthing
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 185 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 27 above but cable of cross sectional area 120 sq mm 3.5 core
All as per item No 27 above but cable of cross sectional area 95 sq mm 3.5 core
All as per item No 27 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 27 above but cable of cross sectional area 16 sq mm 2 core
All as per item No 37 above but cable of cross sectional area 10 sq mm 4 core
All as per item No 27 above but cable of cross sectional area 10 sq mm 2 core
All as per item No 27 above but cable of cross sectional area 185 sq mm 3.5 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 120 sq mm 3.5 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 95 sq mm 3.5 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 50 sq mm 3.5 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 35 sq mm 3.5 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 25 sq mm 4 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 16 sq mm 4 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 16 sq mm 2 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 10 sq mm 2 core including taking down old unserviceale cable
All as per item No 27 above but cable of cross sectional area 6 sq mm 2 core including taking down old unserviceale cable
Supplying, jointing and testing heat shrinkable type outdoor, end termination jointing kit, suitable for cable of size 70 to 120 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 44 above but suitable for cable of size 150 sqmm to 185 sqmm.
S&F cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel confirming to Fe-290 (Gde E-165) including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size complete all as specified and directed by Engr-in-Charge. Note :Exposed steel surface shall be treated with two coats of synthetic enamel paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 47 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note : - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable including taking out old unserviceable bricks all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 54 above but 80mm bore and including taking down Galvanized iron tubing
All as per item No 54 above but 50mm bore
All as per item No 54 above but 50mm bore and including taking down Galvanized iron tubing
All as per item No 54 above but 40mm bore tubing
All as per item No 54 above but 40mm bore and including taking down Galvanized iron tubing
All as per item No 54 above but 15mm bore
S&F steel tubular swaged pole 09 meter long type 410 SP-31 and including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint to remaining portion of pole, clamps etc and marking pole number with synthetic enamel paint black colour in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note :- Earthwork, PCC in foundation & coping shall be meaasured and paid saperately under respective items of BOQ. -------------------------------------------------------------------- Note :- A sum of Rs. 195515/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 24 & 25 (Schedule of Credit) of Tender documents.
Gupta Suppliers
SRI SAI CONSTRUCTION COMPANY
GURDEEP SINGH AND COMPANY
GARG ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .