Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹49.7 L+₹2.7 L (5.80%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹49.7 L+₹2.7 L (5.83%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹50.0 L+₹3.1 L (6.51%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
17 Feb 2021, 6:00 pmClosed
R S SHUKLA EE
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
IMPROVEMENT OF CRCA SHEET ELECTRICAL DISTRIBUTION PANEL BOARDS OF WATER SUPPLY AND OTHER BR WORK AT GE I GOS
2021_MES_415716_1
8000/92/20-21/0993/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR MILITARY STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹90,000
Yes
5 Mar 2021
23 Jan 2021
19 Feb 2021
23 Jan 2021
17 Feb 2021
8 Feb 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M & L coloured vitrified tiles 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed
M & L coloured vitrified tiles 10 mm thick (square/rectangular)polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles but in verticle surface incl 10 mm thick rendering in CM 1:3 complete all as specified and directed
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
Taking down old wooden/wood based particle board & S&F 18/19 mm thick high density PVC solid fibre board duly laminated 2mm thick prelaminated PVC sheet on front face (ISI mark) etc in kitchen cupboard etc complete all as specified and directed.
Taking down old wooden/wood based particle board & S&F 12 mm thick high density PVC solid fibre board duly laminated 2mm thick prelaminated PVC sheet on front face (ISI mark) etc in kitchen cupboard etc complete all as specified and directed.
S & F 40 mm dia cupboard knobs fixed with nuts screw and washer of brass polished, complete all as specified & directed.
S&F continuous (piano) hinges of brass width of flaps (when open) 40 mm,bright finish or electrogalvanised with cadmium plated screws complete all as specified and directed
S & F magnetic catcher catcher with nut and screw of mild steel bright finish complete all as specified and directed
S&F in repairs door seal with aluminium beading and 50 mm wide rubber seal complete fixed to aluminium/ Wdn doors complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
S & F in repairs sheet Glass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings laid in trenches of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings laid in trenches of 20 mm bore of pipe complete all as specified and directed.
S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed
S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed
Making connection of PPR distrubtion branch with PPR main of following outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed.
Taking down bib tap /wash basin tap/pillar tap/stop cock/mixture tap and refixing the same after repair and replacement of washer 15 mm bore size complete all as specified and directed.Note: spindle where required will be measured and paid separately
S&F in repairs brass spindle short body of 15 mm bore complete all as specified and directed
S&F in repairs brass spindle long body of 15 mm bore complete all as specified and directed
S&F in repairs bib taps cast copper alloy with crutch or butterfly handle fancy type, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore dia of pipe complete all as specified and directed. Make- Jaguar
S & F in repair Brass chromium plated wall mixer hot and cold arrangement long shank suitable for 15 mm bore of pipe complete all as specified and directed. Make- Jaguar
S & F in repair Brass chromium plated Basin mixer hot and cold arrangement long shank suitable for 15 mm bore of pipe complete all as specified and directed. Make- Jaguar
S&F in repair Chromoium plated angle cock, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or brass ferrule, 15 mm bore complete all as specified and directed. Make- Jaguar
S&F in repair, 15 mm bore stop cock, cast copper alloy with long shank and cup (concealed type) fancy type chromium platedscrewed down high pressure with crutch & butterfly handle screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs Stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle chromium plated fancy type screwed both ends for iron pipe or for unions for 15 mm bore of pipe complete all as specified and directed. Make- Jaguar
S & F in repair brass chromium plated bottle traps for Wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed as per approved quality complete all as specified and directed
S&F in repair PVC waste pipe for urinal/WHB etc complete all as specified and directed
S&F in repairs CP 32 mm bore waste coupling of (half or full threaded) etc complete all as specified and directed.
S&F in repairs Chromium plated grating doom 100 mm dia fixed in floor in CM 1:3 complete all as specified and directed
S & F in repair CP Jet spray of approved quality complete all as specified and directed
S & F in repair Toilet Paper holder chromium plated fixed to wall complete all as specified and directed.Cat CAN 1151 N make Jaguar
S&F in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mm with brackets, including supply & fixing pillar cock 15 mm bore CP fancy type, PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc complete all as specified and directed.
S&F in repairs Wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed.
S&F in repairs plastic water closet seat cover, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S& F in repair 1 mm thick stainless steel plate rack of size 900X600X200 incl fixing with rawal plug and screws complete all as specified and directed.
S & F rotational moulded three layered white coloured polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed.
S & F rotational moulded three layered white coloured polyethylene water storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed
S&F ball valves for 20 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F ball valves for 25 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S&F in repairs ball valves for 20 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs ball valves for 25 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S&F in repairs brass chromium plated shower rose 125 mm size with or without swivel joint complete all as specified and directed.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm long complete all as specified and directed.
S&F in repairs PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, cantilever brackets ,inlet, ball valve, float and handle, PVC connection 15mm dia etc complete all as specified and directed.
S & F in repairs internal fitting (syphon) for low level flushing cistern complete all as specified and directed.
S&F in repairs flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cistern complete all as specified and directed.
S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
S & F in repair Europian WC floor mounted cascade pattern vitreous china with dual core flushing cistern incl all fitting flush pipe etc make Hindware cat 92048 (starwhite) or equivalent of specified make complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed. Make- JAguar
S & F in repair chromium plated towel ring with bracket complete all as specified and directed.Cat AQN -7721 Make JAGUAR
S&F in repairs Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of 20 mm bore of pipe complete all as specified and directed.
S&F in repairs Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked) for iron pipe of 25 mm bore of pipe complete all as specified and directed.
S&F in repairs cabinet mirror of size 600 mm x 450 mm in bathroom complete all as specified and directed
S & F in repair Soap dish any type fixed to plug with chromoium plated brass screw complete all as specified and directed. Make- Jaguar
S&F in repairs Stop cock single lever 3 inlet diverter exposed parts kits consisting of operating lever wall flange Model OPP-15193 KPM make Jaguar
S & F in repairs wall mounted wash basin Cat CNS WHT 807 size 600 X 500X215 mm complete all as specified and directed
S&F in repairs Towel Rack 600 mm long without lower Hangers but with 3 hooks Cat CAN-1181 FHN make Jaguar
S & F in repairs Hand shower (Health faucet) with 1 mtr long Easy flex tube in crome finish & wall hook Cat ALD-565 make Jaguar
S & F in repair Over head Shower 100 mm round shape single flow (ABS body chrome plated with gray face plate ) with rubit cleaning system Model OHS 1989 Make Jaquar
S & F in repairs Chromium plated Pillar tap for wash basin cat 81001 make Jaguar
Supply and laying 40mm dia GI pipe, medium grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc complete all as specified and directed. Make : Tata/ Jindal /Zenith
M&L in replacement of earthing complete with galvanised iron strip 32mm x 6mm and galvanised iron earth plate electrode 600x600x6mm thick, burried directly in ground(earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 2.25 meters below normal ground level, connected to galvanised earth lead wire 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel and GI pipe 'L' grade of 40mm dia for protection of earth lead and 20mm dia GI pipe 'M' grade for watering with wire wash funnel etc as shown in electrical plate No. 5 of SSR part - I (2009) connected to earthing test point all as specified or indicated including testing on completion as per IE rule. (Note-GI strip and protection pipe beyond 7.5m shall be measured and paid seperately)
Supply and Replacement for On Load Change Over Switch 63 Amp capacity, 415 volts , 3 phase AC , 50 HZ 4 pole in sheet steel encloser type including Grouting on floor along with necessry channels , brackets , nuts , bolts & PCC work also including Reconnecting to existing cables with new lugs complete all as specified and directed .
Supply and fix in replacement of MCCB 4 pole , 415 V , with Microprocessor release 250 Amps with breaking capacity 36 KA panel mounting type , AC, complete all as specified and directed . Make – CG/HAVELL’S/ L&T/C&S.
All as per item no 79 but of 100 Amps
All as per item no 79 but of 63 Amps
Supply, laying and testing in replacement XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve for cable of size 50 sqmm 3.5 core complete all as specified and directed . - Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items Make:- Havells / polycab / cci / nicco / Gloster
All as per item no. 82 above but 70 sqmm 3.5 core complete all as specified and as directed
All as per item no. 82 above but 35 sqmm 3.5 core complete all as specified and as directed
All as per item no. 82 above but 25 sqmm 4 core complete all as specified and as directed
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5M deep for foundation/cable trench, not exceeding 10 Sqmm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed..
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.
Supply and laying flyash building bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Supply and replacement contactor 16 Amps capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ Make – CG/L&T/BCH/ HAVELL’S/Seimens.
All as per item No 91 above but 25 Amps capacity.
All as per item No 91 above but 32/35 Amps capacity.
All as per Item No. 91 above but 40/50 Amps capacity
Supply and fix in replacement of DOL starter for submersible pump set type MK-I and relay range 9-14 amps with contactor complete all as specified and directed.
Supply and fix in replacement thermal over load relay of range 6.5 to 10 Amps complete all as specified and directed Make- CG/L&T/ BCH/C&S.
All as per item No 96 above but 15 to 22 Amps capacity.
All as per item No 96. above but 24 to 34 Amps capacity.
Supply and fix in replacement of indicating lamp set (RYB) LED type complete.
S&F in repair Star Detla Timer 0-30 Seconds duration make L&T/Havell's/C&S
Supply and fix in replacement of low/high voltage monitoring device 440 volts, 3 phase Make- EAPL/L&T./Minilec
Supply and fix in replacement of phase monitoring device 440 volts, 3 phase Make- EAPL / L&T/Minilec.
Supply & fix in replacement of Dry run & over load protection with phase failure relay alongwith suitable CTS Make : EAPL/MINILEC
Supply and fix in replacement of electronic adjustable cyclic timer Make : EAPL /L&T/Minilec.
Supply and fix in replacement Voltmeter digital type (0-500V) Make : AE/L&T/HPL
Supply and fix in replacement Ammeter digital type (0- 100 Amps) Make : AE/L&T/HPL
Supply and fix in replacement CT Coil 60/5 Amps Make : L&T/AE
Supply and fix in replacement CT Coil 30/5 Amps Make : L&T/AE
Supply and fix in replacement of MCB TP 40 amps,
Flushing the bore well for flushing of silt, fine sand etc by air compressor of suitable capacity and pumping out turbidity till obtaining clear water all as directed and as per site requirement.
S& F of gland packing of motors/Pumps of various capacity,including necessary tools,greasing of gland.complete all as specifed and directed by engg-in-charge
S& F of gland packing of Sluice valve of any size ,including necessary tools,greasing of gland.complete all as specifed and directed by engg-in-charge
Dismantling of old unserviceable and M & L for Construction of Brick masonry valve chamber of size 900x900x900mm (internal dimension) chamber depth to be reckoned from the top of PCC foundation to top of brick wall, including PCC1:4:8 type D2 in foundation PCC 1:2:4 type B1 in coping, brick work in cm 1:4, plaster 15 mm thick in CM 1:4 flush pointing externally as the work proceeds, MS Sheet cover 3.00 mm thick with handle and locking arranging and angle iron frame of size (25 x 25 x 5 mm) including painting with two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed
Dismantling of old unserviceable and M & L for Construction of Brick masonry valve chamber of size 600x600x450mm (internal dimension) chamber depth to be reckoned from the top of PCC foundation to top of brick wall, including PCC1:4:8 type D2 in foundation PCC 1:2:4 type B1 in coping, brick work in cm 1:4, plaster 15 mm thick in CM 1:4 flush pointing externally as the work proceeds, MS Sheet cover 3.00 mm thick with handle and locking arranging and angle iron frame of size (25 x 25 x 5 mm) including painting with two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed
S & F MS Sheet cover 3.00 mm thick with handle and locking arranging including hinges and angle iron frame of size (25 x 25 x 5 mm) including painting with two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
Taking down old unserviceable and S & F Heavy Duty Fully Automatic Star-Delta AC-3 Duty, 415 V , 50 HZ, 3-PH starter upto 15 HP relay range 9-10 KW type DX-P with robust 4 pole Contactor includig Electronic star-Delta Timer in S.S. enclosure complete all as specified and directed .
M & L for preparation of old steel surfaces and applying one coat of synthetic enamel paint in position to all surfaces for pump sets complete including base frames , Suction and discharge pipe lines, sluice valves , NRV , LT Panel Board etc pump house, writing of SM/MES No. neat and clean, visible size of letters and all as specified.
M&L in repair mild steel work for angles supports clamps, fabricated from structural steel section including nuts,bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing of paint including taking out existing unserviaceble MS work of open well channel and MS ladder etc complete all as specified and directed.
Supply and fix in repair street light LED type fitting 25 watt 240 volt,50 Hz,6000K cast aluminium housing toughened glass IP 65/66 and wired with all accessories with 20 mm light grade GI pipe through clampig on pole from of size 1.5 sqmm twin core weather proof including 25 mm GI bracket bend to shape with suitabl enuts ,bolts and angles for fixing of bracket all as specified and directed
Point wiring in replacement for one light/fan/bell buzze rpoint or one call bell point controlled by one switch with FRLS cable 1100V grade single core confirming IS 694 (1990) PVC insulated and unsheathed multi standard FRLS copper conductor 1.5 Sqmm as wiring and earth continuity conductor 1.5 Sqmm PVC insulated connecting to common earth drawn in PVC Casing Caping of white/ ivory colour including all accessories heavy duty ISI marked, with all fittings and accessories including factory made M S / pressed steel terminal boxes with zink coated suitable for mounting switches and Fan regulators etc and 3 mm thick plastic laminated sheet top cover including necessary casing and capping complete all as specified and directed.
S & F in repacement for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F in replacement for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and as directed (Make 3M, REYCHEM, M-seal)
All as per item No 125 above above but of size 70 to 150 Sqmm complete all as specified
Taking out old mechanical type water level indicator complete,with float (PVC) heavy duty of suitable size connected to one end of approved quality flexible nylon rope 13mm dia and indicator dead weight type, MS steel needle to the other end of the rope for smooth movement, including suitable size of pulley fixed on angle iron bracket mounted on wall top of the tank/sump and drilling hole for passing rope of level indicator into the tank from the top of the level indicator board, preparation of old plastered surface of wall applying two coats of synthetic enamel and marking of indicator scale for depth in feet and quality of water in litres complete all as specified and directed.
M/s Bapujee Builders and Traders
M/s MAA BHAIRABI ENTERPRISES
M/s Ats Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .