| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L1 | Accepted-AOC Being a lowest Bidder | |
| 2 | L2₹46.1 L+₹5.6 L (13.9%)Rejected-Finance 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹46.2 L+₹5.7 L (14.0%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.2 L+₹5.7 L (14.1%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹46.4 L+₹5.9 L (14.5%)Rejected-Finance 0 KALIKAPUR KALIKA PUR CHAMPAHATI SOUTH 24 PARGANAS WEST BENGAL 743330 | 24 PARAGANAS SOUTH | WEST BENGAL | 743330 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
23 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY SYSTEM AT OTM/MD ACCN AT OUTSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2021_MES_485686_2
8801/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
GE (FW) Kolkata
₹72,000
27 Jan 2022
9 Dec 2021
24 Dec 2021
9 Dec 2021
23 Dec 2021
9 Dec 2021
60 days
Amount
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed.
Excavation in trenches exc 1.5 metre width and not exceeding 3.0 metre in depth for laying of Steel tubular poles/stays etc., in soft/loose soil and getting complete all as specified and as directed.
Excavation of trench in road/hard standing etc, not exc 1.50 m wide and not exc 1.50 m deep and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed.
Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M & L for hardcore of gauge exc 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 using 40 mm graded crushed stone aggregate complete all as specified and directed by the Engineer-in-Charge.
M&L for dry sand cushioning/sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. NOTE: Punned thickness only shall be measured for payment)
Supply and laying bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
Horizontal Boring under road / foot path/hard standing, for passing pipes up to 100 mm bore (dia), not exc. 20.00 metre in a single length, complete all as specified and directed. (NOTE: Pipes shall be measured and paid separately)
Dismantling of broken/dislodged pre-stressed concrete poles/steel tubular poles, of any description including earthwork for removal of concrete foundation, keeping serviceable poles in safe custody for re-use and removal of unserviceable poles from site complete all as specified and directed.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 50 Sqmm, 3.5 core
70 Sqmm to 120 Sqmm, 3.5 core
150 Sqmm to 185 Sqmm, 3.5 core
240 Sqmm to 400 Sqmm, 3.5 core
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No.13 above) complete all as directed by the Engr-in-Charge of the following sizes :- Note : Necessary earth work shall be measured and paid separately under respective items.
10 sqmm 3.5/4 core to 16 Sqmm, 3.5/4 Core
25 Sqmm to 50 Sqmm, 3.5 core
70 Sqmm to 120 Sqmm, 3.5 core
150 Sqmm to 185 Sqmm, 3.5 core
240 Sqmm to 400 Sqmm, 3.5 core
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole complete of the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
25 Sqmm, 3.5 core
35 Sqmm, 3.5 core
50 Sqmm, 3.5 core
120 Sqmm, 3.5 core
185 sqmm, 3.5 core
240 sqmm, 3.5 core
400 sqmm, 3.5 core
S&F heat shrinkable straight through Joints using suitable jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
upto 16 sqmm, 3.5/4 core
25 sqmm to 50 sqmm, 3.5/4 core
70 sqmm to 150 sqmm, 3.5 core
185 sqmm to 240 sqmm, 3.5 core
300 sqmm to 400 sqmm, 3.5 core
S&F in repair MCCB, 4 pole, 50 KA, with thermal magnetic release, 630 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM94104OOT1OG / LEGRAND, Cat No: 4220 23 / C&S, Cat No: CSCS630EM6304P / HAGER, Cat No; HMJ631DE or equivalent model in SCHNEIDER / ABB)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 400 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM98403OOROOG / LEGRAND, Cat No:4220 07 / C&S, Cat No: CSE3N400ATM4P-400 / HAGER, Cat No: HNJ401DR or equivalent model in SCHNEIDER / ABB)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, range 315 - 320 amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No - CM98403OOQOOG / LEGRAND, Cat No: 4220 06 / C&S, Cat No: CSE3M400ATM4P_320 / HAGER, Cat No: HNJ321DR or equivalent model in SCHNEIDER / ABB)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 250 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM92109OOP1OG / LEGRAND, Cat No: 4202 49 / C&S, Cat No: CSE2SX250ATM4P-250 / HAGER, Cat No: HNT251DR equivalent model in SCHNEIDER / ABB)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 200 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM92109OON1OG/ LEGRAND, Cat No: 4202 48 / equivalent model in C&S / HAGER/ SCHNEIDER / ABB)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic, 160 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM92108PPM1OG / LEGRAND, Cat No: 4200 97 / C&S, Cat No: CSE2NN250ATM4P-160 / HAGER, Cat No: HNS161DR or equivalent model in SCHNEIDER / ABB)
Supply and fix (in replacement) MCCB 4 pole 25 KA with thermal magnetic release range 100 Amps Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make : L&T, Cat No : CM91712OOKOOG / LEGRAND, Cat No: 4200 55 / HAGER, Cat No: HHS101DR / C&S, Cat No: CSE1M125ATM4P-100 or equivalent model in SCHNEIDER /ABB)
Supply and fix (in replacement) MCCB 4 pole 36 KA with thermal magnetic release range 63 Amps Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make : L&T, Cat No - CM97919OOH2OG / LEGRAND, Cat No: 4200 93 / HAGER, Cat No: HNS064DR / C&S, Cat No: CSE1NN125AATM4P-63 or equivalent model in SCHNEIDER /ABB)
S&F 100 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor complete, as in repairs, all as specified and as directed by the Engineer-in-charge.
S&F 80 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor complete, as in repairs, all as specified and as directed.
S&F GI tubing 50mm bore (light grade) in trenches/floor/fixed along pole for cable/earth strip protection with proper size of clamp, nuts and bolts or for fixing lightning conductors etc., as in repairs, all as specified and as directed by Engineer-in-Charge.
Supply and errection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt as specified type 410 SP-31 (9 Meter long) duly painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and one coat of black bituminous paint on embedded surface and applying two coats of synthetic enamel paint upto 1.20m height with two black & two yellow colour strips and inscribe the pole Nos with white colour synthetic enamel paint on black shade, complete all as specified and directed. NOTE: Earthwork and PCC foundation for installation of pole shall be measured separately.
Erecting of serviceable pre-stressed concrete poles/steel tubular poles, of any description, with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt etc complete all as specified and directed. (NOTE: PCC foundation for installation of pole shall be measured separately)
Supply and fixing in replacement brackets made out of 32/40 mm dia light grade GI Pipe 1.50 mtr long bent to shape and size fixed on location using new 30 x 5 mm FI clamps- 02 Nos made to shape incl nuts, bolts & washers incl taking down existing bracket complete all as specified and directed.
Material & Labour for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in poles concrete etc., using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge.
Material and labour for PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge.
S&F PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs incl taking down existing cable, as in repairs, complete all as specified and as directed.
S&F cable route indicator (blue in colour) for LT UG cable of 1100 volts, with embossed letters, min 80 mm dia, made from 5 mm thick cast iron plate 80 mm dia, bolted with 40 x 40 x 6 m angle iron of height 0.60 mtr above GL, embedded in PCC (1:3:6) type C2 (using 40 mm graded aggregate) of size 200 x 200 x 200 mm block, including taking down old unserviceable one, complete all as specified and directed. NOTE: Cost of PCC is deemed to be included in quoted rate)
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts, in any shape of size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint incl dismantling of existing unserviceable cross arms complete all as specified and as directed.
S&F in repair cable junction box 205 x 255 x 112 mm in size, made out of thermoplastic sheet having IP 66 protection for outdoor installation including terminals for fixing on street light pole using GI clamps of size 30 x 5 mm (02 Nos each pole) with suitable size of nuts, bolts, washers etc incl dismantling of old unsv box complete all as specified and directed. (MAKE : HENSEL, Cat No: KF 2525B or equivalent model in SPELSBERG / SCHNEIDER / RITTAL)
S&F in repair GI tubing 50mm bore (light grade), 70 to 100 cm long with long bends on one end, for incoming and outgoing cables, duly grouted in cement concrete complete all as specified and as directed. (NOTE: Cement concrete will be measured separately)
Taking down and re-fixing of serviceable street light/security light fitting, any wattage or size, in any position with new bracket incl necessary electrical connection with existing cable complete all as specified and directed. (NOTE: Bracket shall be measured and paid separately)
M&L for preparation of old painted surfaces of steel tubular poles above PCC coping including cross arms, brackets, pole box and applying one coat of aluminium paint including removal of vegetation on poles, trimming of tree branches in the vicinity, writing of pole number with stencil in white paint over black base and two black and two yellow stripes upto 1.20 m height with synthetic enamel paint complete all as specified and directed.
Dismantling carefully serviceable isolating LT panel board of size 1500 mm x 900 mm x 600 mm to 2500 mm x 2000mm x900 mm, duly unscrewing/opening front and back cover and cleaning complete bus bar chamber, tightening all the nuts, bolts, incoming and outgoing terminals including cleaning all the switchgear/accessories and replacement of cable gland and replacement of stainless steel hinges of size 100mm for panel board door, fixed with welding machine incl applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface including reconnecting the panel and testing to the entire satisfaction of the engineer-in-charge. (NOTE: Cost of nuts, bolts, washers, screws, stainless steel hinges, colour tape for bus bar, recharging and testing shall be deemed to be included in the quoted rates)
All as per item No.41 above, but panel of size 500 x 500 x 500 mm to 1500 x 900 x 600 mm complete
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
JAGATMATA ENTERPRISE
M A ENTERPRISES
SINHA ENTERPRISE
GHOSH ENTERPRISE
AZIM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .