Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Accepted-AOC Satisfy | |
| 2 | L2₹15.3 L+₹52,818.25 (3.57%)Rejected-Finance | L2 | Rejected-Finance Higher rate | |
| 3 | L3₹15.3 L+₹52,955.25 (3.58%)Rejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Higher rate | |
| 4 | L4₹15.8 L+₹1.1 L (7.10%)Rejected-Finance VILL BALIPOTA P O NARAJOLE P S DASPUR DIST PASCHIM MEDINIPUR PIN 721211 WEST BENGAL | NARAJOLE | PASCHIM MEDINIPUR | WEST BENGAL | 721211 | L4 | Rejected-Finance Higher rate | |
| 5 | L5₹15.9 L+₹1.2 L (7.83%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L5 | Rejected-Finance Higher rate |
| Sl No | Description | Qty | Unit | Electromech Engineers Co-Operative Society Ltd. L1 | BISWAKARMA ELECTRIC WORKS L7 | GHANASHYAM ELECTRIC STORES L5 | S. A. ENTERPRISE L3 | M/S. N.C. HORE L6 | EFFORTECH L4 | M/S SAMRIDDHI ELECTRO & CO. L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.01 | LT panel with IP66 Enclosure Box:- | 1 | Nos. | 1,25,253 ₹1,25,253 Lowest | 2,70,000 ₹2,70,000 | 3,18,000 ₹3,18,000 | 2,53,560 ₹2,53,560 | 2,70,000 ₹2,70,000 | 2,28,301 ₹2,28,301 | 1,67,167 ₹1,67,167 |
| 1.02Supply,Installation,Testing of Cubical type floor mounted LT panel Board of suitable dimension comprising of the following electrical accessories fabricated from 40X40X5 mm MS angle and 14 SWG CRC Sheet with necy. Welding incl painting with 2coats of Synthetic Enamel paint over 1 coat of RO primer as per GS.Whole arrangement must covered with suitable enclosure like Feeder pillar Box, should have IP-66 Protection class (As the panel may install at outside the generating station, i.e in open space),Should have Body earthing terminal etc and with proper door lock arrangement. A. INCOMING:-- 1)S&F 415V,250A,50kA, 4 Pole MCCB in SS enclosure (make -- legrand, Equivalent L&T,Schneider)-1nos.With Thermal magnetic release;Type- DPX3 250 Cat no 4202 79, with spreader terminal,MIL base plate etc as required. B.Bus Bar:- 4 nos tinned Copper bus bar of size 50X5mm, length as per requirement each having for Phase and N in Sheet metal box (14 SWG) with hinge type door with locking arrangement with telescopic screw -1 no.Panel should have continious earth busbar for Body earthing. | ||||||||||
| 1.03C.OUTGOING:--(all are SS enclosure type) 1) S & F 415V, 125A, 36kA, 4 Pole MCCB (make -- Legrand, Equivalent L&T, Schneider) ---5 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 95, with spreader terminal,MIL base plate etc as required. 2) S & F 415V, 160A, 36kA, 4 Pole MCCB (make -- Legrand,Equivalent L&T,Schneider) ---1 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 93, with spreader terminal,MIL base plate etc as required. 3)S & F 415V, 63A, 36kA, 4 Pole MCCB (make -- Legrand, Equivalent L&T, Schneider) ---2 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 95, with spreader terminal,MIL base plate etc as required. | ||||||||||
| 1.04CABLE ALLEY cable alleys on both sides for out going connection are to be made incl. S & F suitable nos of Brass Studs type connector on insulated chair having current carrying capacities as per the out going switches rating. Inter connection with the M S & Stud connectors is to be made with suitable size stranded copper wire as per the switch rating as specified in Interconnection. | ||||||||||
| 1.05INTERCONNECTION Inter connection to be made same with 20X5 mm (For 125A and 160A MCCB) and 15x3 mm (for 63 A MCCB) copper bar/ 35sqmm (For 125A and 160A MCCB) &16sqmm(for 63 A MCCB) stranded flex copper cable (Finolex/Havells/Polycab/RR kabel) & metering circuit with 1.5 sq mm single core stranded FRLS PVC copper wire with proper copper socketing & taping ( R Y B & N). All nut bolts are of Stainless steel type. | ||||||||||
| 1.06READING ARRANGEMENT a) S & F digital multifunction meter (L&T, MFM5010 LED meter CI 1.0 with RS485, cat no-- WL501011OOOO/Schneider Conzerv-EM6400NG)---1nos (for incoming ) c) 250A/5A CT Coil ( Kappa Make) - 3 nos (for incoming) e) LED type indicating lamp ( R Y B ) - 3nos (incoming) f) 2 A MCB ("C" curve, Legrand) --- 3 nos g) Danger board -- 02 no | ||||||||||
| 1.07Drawing and Make,cat no of all items and feeder piller box must be approved prior any execution/manufacturing work.Test reports of each MCCBs and others should be submitted along with the drawing for necy. approval from EIC. | ||||||||||
| 2.00Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Gloster/Havells/polycab) as mentioned below as per choise of EIC:- Vide page no F-5 Item no 8(a) | ||||||||||
| 2.10 | 4 core 150 sqmm.(For panel to WBSEDCL) | 220 | Mtr | 1,393 ₹3,06,460 | 1,900 ₹4,18,000 | 1,242 ₹2,73,240 | 1,080 ₹2,37,600 Lowest | 1,102 ₹2,42,440 | 1,410 ₹3,10,200 | 1,600 ₹3,52,000 |
| 2.20 | 4 core 120 sqmm.(From Seminar Room AC VTPN to Gr floor Panel) | 65 | Mtr | 1,163 ₹75,595 | 1,500 ₹97,500 | 1,011 ₹65,715 | 890 ₹57,850 Lowest | 896 ₹58,240 | 1,159 ₹75,335 | 1,249 ₹81,185 |
Tender Value
Refer Docs
EMD Value
₹38,267
Closing Date
7 Jun 2025, 3:00 pmClosed
EE II CKHED
P12 CIT Road 1st floor Kol 14
Construction of New Hostel cum messing Facilities at Hariharpur BPHC RHTC of NRSMC in the of South 24 Paraganas under Kolkata Central Health Division PW Dte during the year 2021 2022 3 storied Building with 4 storied foundation External electrica
2025_WBPWD_848758_1
WBPWD/EE-II/ CKHED/eNIT-02/25-26R
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
NRS MCH
as per nit
4 documents required · 4 mandatory
₹38,267
27 Aug 2026
19 May 2025
9 Jun 2025
19 May 2025
7 Jun 2025
24 May 2025
Amount
LT panel with IP66 Enclosure Box:-
Supply,Installation,Testing of Cubical type floor mounted LT panel Board of suitable dimension comprising of the following electrical accessories fabricated from 40X40X5 mm MS angle and 14 SWG CRC Sheet with necy. Welding incl painting with 2coats of Synthetic Enamel paint over 1 coat of RO primer as per GS.Whole arrangement must covered with suitable enclosure like Feeder pillar Box, should have IP-66 Protection class (As the panel may install at outside the generating station, i.e in open space),Should have Body earthing terminal etc and with proper door lock arrangement. A. INCOMING:-- 1)S&F 415V,250A,50kA, 4 Pole MCCB in SS enclosure (make -- legrand, Equivalent L&T,Schneider)-1nos.With Thermal magnetic release;Type- DPX3 250 Cat no 4202 79, with spreader terminal,MIL base plate etc as required. B.Bus Bar:- 4 nos tinned Copper bus bar of size 50X5mm, length as per requirement each having for Phase and N in Sheet metal box (14 SWG) with hinge type door with locking arrangement with telescopic screw -1 no.Panel should have continious earth busbar for Body earthing.
C.OUTGOING:--(all are SS enclosure type) 1) S & F 415V, 125A, 36kA, 4 Pole MCCB (make -- Legrand, Equivalent L&T, Schneider) ---5 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 95, with spreader terminal,MIL base plate etc as required. 2) S & F 415V, 160A, 36kA, 4 Pole MCCB (make -- Legrand,Equivalent L&T,Schneider) ---1 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 93, with spreader terminal,MIL base plate etc as required. 3)S & F 415V, 63A, 36kA, 4 Pole MCCB (make -- Legrand, Equivalent L&T, Schneider) ---2 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 95, with spreader terminal,MIL base plate etc as required.
CABLE ALLEY cable alleys on both sides for out going connection are to be made incl. S & F suitable nos of Brass Studs type connector on insulated chair having current carrying capacities as per the out going switches rating. Inter connection with the M S & Stud connectors is to be made with suitable size stranded copper wire as per the switch rating as specified in Interconnection.
INTERCONNECTION Inter connection to be made same with 20X5 mm (For 125A and 160A MCCB) and 15x3 mm (for 63 A MCCB) copper bar/ 35sqmm (For 125A and 160A MCCB) &16sqmm(for 63 A MCCB) stranded flex copper cable (Finolex/Havells/Polycab/RR kabel) & metering circuit with 1.5 sq mm single core stranded FRLS PVC copper wire with proper copper socketing & taping ( R Y B & N). All nut bolts are of Stainless steel type.
READING ARRANGEMENT a) S & F digital multifunction meter (L&T, MFM5010 LED meter CI 1.0 with RS485, cat no-- WL501011OOOO/Schneider Conzerv-EM6400NG)---1nos (for incoming ) c) 250A/5A CT Coil ( Kappa Make) - 3 nos (for incoming) e) LED type indicating lamp ( R Y B ) - 3nos (incoming) f) 2 A MCB ("C" curve, Legrand) --- 3 nos g) Danger board -- 02 no
Drawing and Make,cat no of all items and feeder piller box must be approved prior any execution/manufacturing work.Test reports of each MCCBs and others should be submitted along with the drawing for necy. approval from EIC.
Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Gloster/Havells/polycab) as mentioned below as per choise of EIC:- Vide page no F-5 Item no 8(a)
4 core 150 sqmm.(For panel to WBSEDCL)
4 core 120 sqmm.(From Seminar Room AC VTPN to Gr floor Panel)
4 core 25 sqmm.(For lift)
2 core 10 sqmm.(For Compound light)
Laying of one No. cable upto 35 sqmm inunderground trench 460mm wide x 760mm average depth,with brick protection on the top of the cable with 8 (eight) Nos.brick asper Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. Vide page no F-2 Item no1.(b)
Laying of cable of following sizes on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting as mentioned below as to GS:- Vide page no F 1 Item no 2
4 core 25 sqmm
4 core 120 sqmm
4 core 150 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : vide page no F-4 item no 7
a) 2 core 10 sqmm
b) 4core 25 sqmm
c) 4 core 120 sqmm
d) 4 core 150 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
a) 2 core 10 sqmm
b) 4 core 25 sqmm
c) 4 core 120 sqmm
c) 4 core 150 sqmm
Supply & Fixing of perforated GI cable tray reducer with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the reducer incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
a)200X50X1.25mm(18SWG)
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS.For soft soil Vide page no G 1 Item no 1.a.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below By TATA-Medium GI pipe. : Vide page no G 1 Item no 2.a
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as per GS Vide page no G 2 Item no 4.c
Connecting the equipments body to earth busbar incl. S & F 25 mm x 3 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. as to GS. Vide page no G 3 Item no 5.e.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS. Vide page no G 2 Item no 3.a
Extra for treatment of soil by using salt & charcoal or coke for plate electrode as to GS. Vide page no G 2 Item no 3.b
Connecting the equipments to earth busbar including S & F GI(Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Solid No 10 SWG GI wire
Note: All bolts/washers/nuts etc must be are of Stainless steel type and washers must be spring type.
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc Vide page no D-2, Item no 3a
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required vide page no F-6 item no 11
a)100 mm.(For service cable protection)
b) 80 mm. For service cable protection)
c) 40 mm.( for compound light road crossing protection).
S&F 12" long MS frame with both side D clamp, drilled holes made of 30x30x5mm MS angle with nuts, bolts, washers and grouted in the cement concrete on wall suitable for fixing of 150 sqmm XLPE armoured cable complete with fastner and mending good the damages as per direction of EIC.
Cost for wall cutting, others civil work,Cleaning all the sites (where civil dismantling & new work done) & restoring the area (for Public Use) & remove all the rubbish outside premises as per direction of EIC.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Vide page No D-11, Item No-15] Incoming - 415V, 25/35KA, 160A, FPMCCB (1 -nos)[Vide page No D-8, Item No-10] Outgoing - 10KA, (C-characteristics) 63A, TPMCB - (6 -nos)[Vide page No D-6, Item No-7 (For Seminar Room AC) (dew to not included at Verticel extension internals works)
6 way [Legrand/ LK]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(RR Kabel/Finolex/Polycab/KEI as approved by EIC) incl the following sizes of the polythene pipe 25mm/19mm as required and by the prelaid GI fish wire and making necy. connection as required. [E-9,1]
a) 4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC) [ For AC ] [Vide page no-E-9,item no-1(d1)] (From VTPN to AC outdoor) (dew to not included at Verticel extension internals works)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.[Vide page No F-5, Item No-9 (i)& (ii)]
a) 4x6 sqmm + 2x4 sqmm ECC [ F-5,9(iv&iii)]
S&F only Exhaust fan ( Heavy Duty ) & louver shutter after making hole in wall and making good damages and smooth cement finish etc. as reqd:300mm(12").[Make: EPC]
Supply and Delivery of 7 mts long, as per specification Top dia -70mm, Bottom dia - 130mm, (Section Length - 7000mm) thick - 3mm, Base plate-(225 x 225 x 16)mm,PCD - 225mm. Hot Dip GI Octagonal pole fabricated from HT steel confirming to BS EN 10025, S-355JQ along with 4 Nos. M20 x 700" 'J' type foundation bolts and necessary earthing terminal etc. (TRANSRAIL/Valmont/Utkarsh/Bansal)
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.(h-1/1)
a) Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
Supplying & fixing 50mm dia x 5.64 metre long (incl. bends) GI pipe vertical type service bracket on wall for carrying 4 wires and an earth wire complete with Galv. MS clamps for stay, insulators and earth wire, 7/14 SWG stranded GI (Hot Dip) Stay wire with 230x31 mm dia straining screws, 75x88 mm porcelain shackle insulators with Galv. (Hot Dip) strips, bolts, bush etc. incl. painting(h-6/2)
S/F single arm header fabricated with 100 mm dia G.I pipe of 10" length wlded with 1.5 m long 32 mm dia. G.I pipe at an angle of 10 to 15 deg with plate incl. S / F nuts, bolts washer etc incl. painting as per G.S.
Providing CC (6:3:1) muffing 0.3 mtr dia upto the height of 0.3 mtr. above the ground level around the pole base complete with 3 mm hick neatly finished cement plaster all-round after dismantling the unserviceable muffing if necessary(i-1/11)
Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary. (a)Without Loop Box.(i-1/12,A)
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting.Ref I-2/16 (a)
(a) 200 x 150 x 100mm
Loop wiring by 3 x 1.5 sq mm PVC insulated copper wire through alkathene pipe from loop box to LED fittings incl. making necy. Connection as required.
S/F G.I pipe (ISI - Medium) for cable protection with necy. Fitting & jointing materials as required.(For cable protection)Ref:F-6/11(b)
i)32 mm dia GI protection pipe (ISI Medium) from loop box to muffing.
Supply and fixing of LED Light is an IP66 road/ Street lighting luminaire. [Make-Philips, Cat no-BRP409 LED CW 036 MR FG S1 PSU GR 2 or equivalent make and model of Lighting Technology/Wipro]
Supply and fixing of LED Light is an IP66 road/ Street lighting luminaire. [Make-Philips, Cat no-BRP409 LED 115 CW SLC FG PSU GR 2 or equivalent make and model of Lighting Technology/Wipro]
Supply & Fiixing of indoor type LED SIGN Board i) 12'(L)x4'(B)x.8''(W) ii) 6(L)x4'(B)x.5''(W) fabricated from 3 mm thick ACP sheet on all five sides finished with approved metallic colour & suitable size hollow Al rectangular bar as frame inside the box. All LED Module, wiring to be fixed inside the ACP box. Silicon adhesives, SS screws to be used in such a way so that ingress of water can be restricted inside the box and maintenence / replacement of the LED modules can be done easily. All screws/nuts & bolts/clamps etc metals used inside the box should be of non-ferrous metal/Stainless steel.
SIZE-i)12'X4'=48 sqft.x2 (Front/back)=96.00 sqft ii)4'X0.8'=3.2 sqft x2(Top/bottom) =6.4 sqft iii)12'X0.8'=9.6sqft X2 (Top/bottom) =19.2 sqft Total=122.00 sqft Nurshing Hostel Horihorpur BPHC South 24 paragana
Supply & Fixing of Special type of 3D Boxing type letter(6" x 3.5") with top cover openable made from imported 3mm thick Acrylic sheet to accomodate LED module. Only front side of the letter should emit light. side to be made from opaque acrylic sheet. Letter height, width & depth of the letter will be proportionate & as per direction of E.I.C.. Suitable Ratio should be maintained between the letter size, spacing between each letters & spacing between each words as per the direction of the E.I.C. (Calculation of area (square inch) of a letter will be HeightXBreadth of the letter inclusive all wastage. ( letter 33 nos) i)8”x4”=32”Per letter x50 nos. letter=1600 sq.inch*80%=1280 sq.inch II)8”x0.5”=4.00”Per letter x27 nos. letter=108.00 sq.inch*80%=87.00sq.inch Total-1388.00 sq inch
Supply & Fixing of LED within the acrylic letter from backside (Make: SAMSUNG-Korea/ROHS) having the following specifications: COLOUR:WHITE or as per the choice of EIC. LIFE:70,000 burning hours. INTENSITY: Uniform without any bright/dark patches. VISIBILITY: 100Mtrs at least for normal eye vision. AMBIENT AIR: 0-50°C; 100% Relative Humidity. POWER CONSUMPTION: 1.5 Watt per module. (1 module consists of 3 nos LED)
SITC of water proof 400 watt Power Supply unit to be fitted inside the Sign board box. inclusive of water tight gaskette fitted stainless steel hinged door box. Input: 100V-240V AC; 4A; 50Hz. Output: 12V DC; 17-20A constant power supply. Make: Meanwell/Ven/Resang or equivalent.
Supply & Fixing of structural type frame suitable for ACP fascia fixing of size (6" x4"x 2" ) to be made by 3mm thick 2" dia square pipe including necessary machining , welding and jointing materials.
Supply & Fixing extra supporting of structure by 3mm thick 1"x 1" square pipe of 6" & 4" length 4 nos each .
S & F of 26 SWG G.I. sheet for covering of back side of iron frame incl. fabrication charge.
Painting the MS structure with 2 coats of RO primer and one coat of synthetic enamel paint after scrapping the structure emery paper properly.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of through 20mm dia PVC rigid conduit pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm)
Transpotatation charges of the above mentioned board from Co's workshop to work site.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
M/S SAMRIDDHI ELECTRO & CO. (BID ID -6501031)
S. A. ENTERPRISE (BID ID -6528861)
EFFORTECH (BID ID -6504480)
GHANASHYAM ELECTRIC STORES (BID ID -6516193)
M/S. N.C. HORE (BID ID -6507718)
BISWAKARMA ELECTRIC WORKS (BID ID -6509723)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .