Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹42.6 L+₹1.3 L (3.13%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹48.6 L+₹7.3 L (17.6%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Apr 2025, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR /MAINT/REPLACEMENT OF SUMMER COOLING APPLIANCES, UNSERVICEABLE PIPE LINE/PUMP SET /BOREWELL IN EXTERNAL WATER SUPPLY, PUMP HOUSE AND COMPREHENSIVE MAINTENEANCE OF CERTAIN WATER SUPPLY INSTALLATION ALONG WITH CONNECTED ITEMS AT 11 BR AF STN OJ
2025_MES_697645_2
8266/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹90,000
Yes
24 Jul 2025
20 Mar 2025
9 Apr 2025
21 Mar 2025
7 Apr 2025
24 Mar 2025
Amount
Material and labour for taking down Window type air conditioner of any type/make/capacity after disconnecting all electric connection from site (either in ground / any floor), transporting to work site if required, cleaning of air filter, front panel, suction grill, De-dusting of coupler unit, checking electrical connection, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, descaling with non corrosive acid on both side of cooling coil and components, identifying the fault/ trouble in the unit and their redressal, reassembling and refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge (Note: Repair/Replacement of the component required shall be paid under relevant item of schedule here-in-after). (Note:- For Sl No 1 - 110, if any complain not rectified within 24 hrs with user's satisfactory working report penalty of Rs 500 per defect per day shall be recovered from the contractor in FB)
Supply & Fix in repairs air filter elemant pads for window type A/C for 1.5 TR/ 2 TR of size and make during the maintenance complete all as specified & as directed by Engineer-In -Charge.
Supply & Fix in repairs louvers swing motor suitable for window type AC of cap 1.5/2.0 ton cap in situ as per existing make and compatible model, necessary electrical connection and testing after fixing to entire satisfaction of user and Engr-in-Charge.
Supply and fix in repairs blower drum, suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge
Repairs to Micro-processor electronic circuit board (PCB) suitable for 1.5/2.0 ton window type AC including disconnection and taking out unsv PCB and and fixing after repairs, testing complete as per existing make/model complete all as specified & as directed by Engineer-In -Charge.
Supply & Fix in repairs Condensor fan motor double shaft 1/6Hp, 1/8Hp, 1/10Hp for Window type AC of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge
Supply & Fix in repairs blower motor single phase AC 200/230 volts suitable for window type A/C for 1.5 TR/ 2 TR complete all as specified & as directed by Engineer-In -Charge.
Supply & Fix in repairs Air filter suitable for window type AC 1.5 /2.0 TR capacity as per existing make and model complete all as specified & as directed by Engineer-In -Charge.
Supply & Fix in Repairs new sealed unit compressor of 1.5 TR window type room air conditioner (Make: As Per Exisiting or Equivalant) complete all as specified & as directed by Engineer-In -Charge. Note - Cost of Refrigerant gas and Gas charging is deemed to be included in the unit rate quoted of this item.
Supply and Fix in Repairs new sealed unit compressor of 2.0 TR window type room air conditioner (Make: As Per Exisiting or Equivalant) complete complete all as specified & as directed by Engineer-In -Charge. Note - Cost of Refrigerant gas and Gas charging is deemed to be included in the unit rate quoted of this item.
Supply & Fix in repairs Condenser coil unit of window type AC of cap 1.5 / 2.0 ton cap in situ as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit & Fixing New Condenser Coil any Make/model and testing after completion to entire satisfaction of Engr-in-Charge.
M & L Gas Charging and Repairs to window AC of unit 1.5/2 T capacities after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, identifying the leakage in the unit, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a or any other) and non freezing oil achieving desired cooling. Testing the equipment for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Refrigerant will be issued under respective Item of this Schedule)
Material and labour for shifting of window type AC of any capacity and make after taking down of all electrical connection, closing existing window AC alocation with brick/PCC work and carrying it to the new location and cutting the existing window including additions/alterations to make suitable opening for fixing including welding/wood work as per site requirement to match with adjoining/existing surfaces and Refixing the window type air conditioner to the new altered location and making electrical connections, installation testing, commissioning and making good the disturbed surface to match with the existing surfaces complete all as specified and as directed by Engineer-in-Charge.
Material and labour for taking down split type air conditioner of any type/make/capacity after disconnecting all electric connection from site (either in ground / any floor), transporting to work site if required, cleaning of air filter, display, PCB, de-dusting of complete indoor/outer unit, washing condensor unit with suitable water spray jet, checking electrical connection, brush cleaning the whole unit with electric blower, cleaning with water, decaling with non corrosive acid on both side of cooling coil and components, identifying fault/ trouble in the Indoor and Outdoor unit and their rectification/ redressal, rewiring, grasing of movable part for getting trouble free servicing, refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge (Note: Repair/Replacement of the component required shall be paid under relevant item of schedule here-in-after)
Supply and fix in repair condensor coil of copper suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as directed and specified by Engineer-In Charge
Repairs to micro processor Circuit of existing Printed Circuit Board (PCB) in Non-Invertor Split type AC of any make, complete all as specified & as directed by Engineer-In -Charge.
Repairs to micro processor Circuit of existing Printed Circuit Board (PCB) invertor Split type AC of any make, complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs blower drum suitable for split type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs New Micro-processor Printed Circuit Board (PCB) For Non-Invertor split A/C of as existing sample/make or equivalent ,complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs New micro processor Printed Circuit Board (PCB) For Invertor Split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs Indoor blower motor single phase AC 200/230 volts suitable for split model A/C of capacity 1.5 TR/2 TR (Make - As per Existing Make or equivalent), complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs Heavy duty air conditioner outdoor unit stand/ brackets with complete accessorise for window/split AC of capacity of 1.5/2 Ton complete with grouting nut bolts all as specified and as directed by Engr-in-charge .
Supply and fix in repairs contactor switch suitable for existing multi (3 TR Unit) split type unit complete all as specified & as directed by Engineer-in Charge.(Make. Blue star,Schnieder)
Supply and fix in Repairs Suction valve for split AC of any capacity.
Supply and fix in Repairs Discharge valve for split AC of any capacity.
Supply and fix in repairs Condensor fan motor 1300rpm, 1/3 Hp, 1/6Hp, 1/8Hp, 1/10Hp for Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge
Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8 inch copper tubing complete all as specified & as directed by Engineer-In -Charge.
All as per above item 27 but of size 1/4 inch
All as per above item 27 but of size 1/2 inch
All as per above item 27 but of sizer 3/8 inch
Supply and fix in repair flexible cord PVC insulated and sheathed 3 core flexible with copper conductor of size 2.5 sq mm complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs 240 volts 32 amps capacity MCB single pole after taking out old unserviceable MCB from existing position Make - Standard/Havells/Legrand complete all as specified & as directed by Engineer-In -Charge.
M&L in replacement of air filter made out of nylon wire mesh moulded in plastic complete suitable for existing old filter's size and shape, as directed for 1.5/2 TR capacity of split type AC complete all as specified and as directed.
Supply and fix in repairs sheet metal enclosure single pole and neutral 2 Pin and earth metal plug and socket, 240 volts, (Make - Standard/ Havells/Legrand), 32 Amps capacity after taking out old unserviceable DB from existing position complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs Air filter suitable for indoor unit of split type AC 1.5 /2.0 tr capacity as per existing make and model.
Supply and fix in repairs Fibre reinforced PVC drain pipe suitable for split AC out let of 1.5T/2.T capacity.
Supply and Fix in repairs new sealed unit compressor of 1.5 TR split air conditioner (Make - As per Existing Make or equivalent), (Compressor should not be repaired/recondition from Trade). complete all as specified & as directed by Engineer-In -Charge. (Note - Cost of refrigerant gas & Gas charging is deemed to be included with unit quoted rate.)
Supply and Fix in Repairs new sealed unit compressor of 2.0 T for split air cinditioner ( Make - As per Existing make or equivalent) complete all as specified & as directed by Engineer-In -Charge. (Note - Cost of refrigerant gas & Gas charging is deemed to be included with unit quoted rate.)
Supply and fixing in replacement New indoor cabinet along with all Accessories for split AC 1.5 Ton capacity of suitable for existing out door unit fixing at any position, of any make including testing complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement New indoor cabinet along with all Accessories for split AC 2.0 Ton capacity of suitable for existing out door unit fixing at any position, of any make including testing complete all as specified and directed by Engr-in-charge.
Supply and replace remote control unit complete with 2 Nos Duracell battery of Split type AC 1.5 ton /2.Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer In Charge (Note- Cost of Duracell battery is deemed to be included in quoted rate of this item).
Supply and fix in repairs full body base suitable for 1.5 to 2 Ton capacity window / split type air conditioner, made out of GI sheet of 14 SWG and other portion with GI sheet of 20 SWG including motor mounting frame fixing with nuts and bolts of suitable size, duly painted with two coats of synthetic enamel paint over one coat of red zinc chrome primer etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs outer cover for window / split type AC of Capacity 1.5 to 2 TR, made out of GI sheet 20 SWG, duly painting with two coats of synthetic enamel paint over one coat of red zinc chrome primer complete all as specified and as directed by Engineer-in-charge
M & L Gas Charging to split AC of 1.5/2 T capacities after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system with nitrogen gas, identifying the leakage of system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a or as applicable) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling for the following complete all as specified & as directed by Engineer-In -Charge. (Note- Refrigerant will be issued under respective Item of this Schedule)
Taking down existing split AC of any capacity indoor & outdoor unit after disconnecting electrical connection with supporting accessories/brackets from existing position & relocating the same Split AC (making indoor unit and outdoor unit connections) duly mounted on brackets, connecting refrigerant piping , connecting up power supply,recommissioning & testing for smooth running, complete all as specified & directed by Engineer-In-Charge.
Repair to refrigerator of capacity 165/210/310 litres ,General servicing,dismantling unserviceable part of refrigerator, checking electrical connections & rewiring, working, identifying the fault in the system and rectification, cleaning of refrigerator unit ,and making refrigerator serviceable complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply and fix in repairs copper strainer and capillary tube suitable for refrigerator mentioned above as per existing make and sample, in replacement of unserviceable strainer & capillary complete all as specified & as directed by Engineer-In -Charge.
Supply & Fix in Repairs new sealed unit compressor unit (type 1/8 ) , Compressor shall not be got repaired/Recondition from trade. (Make- As Per Exisitng make or equivalent) ,Suitable for 210 litre refrigerator complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant Gas and Gas charging is deemed to be included in unit rate quoted of this item.)
Supply & Fix in Repairs new sealed unit compressor unit (type 1/6 ), Compressor shall not be got repaired/recondition from trade.(Make- As Per Exisitng make or equivalent) ,Suitable for 310 litre refrigerator complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant Gas and Gas charging is deemed to be included in unit rate quoted of this item.)
Supply and fix in Repairs Evaporative cooling coil for refrigerator of capacity 165 to 310 litres of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in Repairs Condensor coil for refrigerator of capacity 165 to 310 litres of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs NRV suitable for for 165 /210/300 lit refrigerator,complete all as specified and directed by Engineer in Charge
Supply and fix in repairs vegetable tray in moulded PVC or plastic suitable for 165 /210/300 lit refrigerator ,complete all as specified & as directed by Engineer-In -Charge.
M & L Gas Charging to refrigerator after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, identifying the leakge, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a or as applicable) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge. (Note- Refrigerant will be issued under respective Item of this Schedule)
M&L in replacement of broken freezer door complete with casing and lock nut as per sample for refrigerator of any capacity complete all as specified and as directed.
M&L for Relay suitable for 1/8 & 1/6 compressor of refrigerator of any make/capacity. complete all as specified and as directed.
M&L in replacement of Thermostat with control knob suitable for existing model of refrigerator of any capacity complete all as specified and as directed.
M&L in replacement of bulb pin type/thread type suitable for existing model of refrigerator of any capacity complete all as specified and as directed.
M&L in replacement of broken door panel gasket complete suitable for existing model of refrigeratior of any capacity complete all as specified and as directed.
M&L forRepair to Deep freezer of capacity 265/ 320 /500 ltrs ,general servicing ,taking down unserviceable part,checking electrical connections & rewiring, identifying the problem and rectification of the same, cleaning of deep freezer unit ,reassembling & making deep freezer serviceable complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply and fix in Repairs capillary tube and silica drier type strainer suitable for Deep Freezer 265/320/500 litre capacity ,complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in Repairs new sealed unit compressor, (Make- As Per Exisitng make or Equivalent) for deep freezer of capacity 265 ,320 ,500 litre complete all as specified & as directed by Engineer-In -Charge. Note- Cost of refrigerant Gas and Gas charging is deemed to be included in unit rate quoted of this item.
All as per above item 62 but for deep freezer of capacity 500 litre complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant Gas and Gas charging is deemed to be included in unit rate quoted of this item.)
Supply and fix in Repairs fan motor 1/35 HP suitable for deep freezer of capacity 265/300/320 litre , fan motor AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
M & L for Gas Charging to Deep freezer after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressere, leak testing of the system, identifying the leakage in system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge. (Note- Refrigerant will be issued under respective Item of this Schedule)
Supply & Fix in repair relay suitable for 1/8 and 1/6 compressor of capacity for deep freezer upto 500 ltr. Complete all as specified and as directed by Engineer-In-Charge.
General Servicing/ Repairs to storage type water cooler of capacity 40/80 & 60/120 ltrs , general servicing ,dismantling unserviceable part, checking electrical connections,cleaning internally and externally , identifying the fault in the system and its rectification, cleaning of water tank,tray & water outlet scraping with emery paper filling putty wherever required and painting with one coat of red oxide and two coats of synthetic enamel paint of approved colour and reassembling marking of MES/SM No in 25 mm size alphabetes,reassembling, refitting & making water cooler serviceable, complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply and fix in Repairs fan motor 1/64 HP suitable for water cooler of capacity 40/ 80 lit AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in Repairs fan motor 1/32 HP suitable for water cooler of capacity 60 / 120 lit , AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs push type spring loaded taps chromium plated brass suitable for 15 mm dia bore of pipe for water cooler complete all as specified & as directed by Engineer-In -Charge.
Supply & fix flexible cold water nylon reinforced PVC c pipe for drain outlet, complete all as specified & as directed by Engineer-In -Charge.
Repair to water cooler stainless steel water tank including soldering existing copper pipe where ever necessary complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in Repairs Brass Chromium plated stop cock both end screwed suitble for 15 mm dia GI Pipe complete all as specified & as directed by Engineer-In -Charge.
S&F in repair Set of Copper Pencil Strainer suitable for Water Cooler mentioned above including taking down old unserviceable copper pencil strainer, complete all as specified and as directed by Engineer-In-Charge.
S&F in repair aluminium fan blade for blower motor for water cooler of Capacity 60/120 ltrs/Hrs, 80/120 ltrs/Hr and 150 ltrs including taking down old unserviceable fan blade complete all as specified & as directed by Engineer-In -Charge.
Supply & fix in repairs Rubber gasket for water cooler top cover as per sample complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs float valve assembly complete with PVC ball valve suitable for 15 mm bore of pipe for water cooler. Make: Prayag, Water tech complete all as specified & as directed by Engineer-In -Charge.
Supply and fix drain tray made stainless steel with required nuts, bolts or screws, brazing out leakage places suitable for any cap incl dismentling taking out unserviceable one suitable for WC Make-Usha, Voltas or Blue Star whichever applicable. Note: Make & size of item shall be as recommended by the manufacturer of WC
Supply and fix in repair condenser coil unit of water cooler 40/80Ltrs or 80/120Ltrs cap as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge suitable for WC Make-Usha, Voltas or Blue Star whichever applicable. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. (ii) Make of item shall be as recommended by the manufacturer of WC
Supply and fix in repair condenser coil unit of water cooler 120/150 Ltrs cap as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge suitable for WC Make-Usha, Voltas or Blue Star whichever applicable. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. (ii) Make of item shall be as recommended by the manufacturer of WC
Taking out old unserviceable OLP of various capacity for 40/80 ltr or 60/120 Ltr capacity.& S&F new OLP for water cooler of any capacity complete all as specified and as directed.
S & F in replacement of PVC connection 15mm size with brass nuts suitable for hot/cold water nylon reinforced 450 mm length
Taking out old broken PVC flexible drain outlet pipe & S & F new drain outlet pipe 32/40mm dia complete for water cooler of any capacity complete all as specified and as directed.
M&L for replacement of old worn out / burnt wiring of water cooler/ deep freezer by using copper conductor wire PVC sheathed of suitable size and length complete all as specified and as directed.
All as per above item 84 but for window/split type A/C of any capacity complete all as specified and as directed.
M&L for repair/replacement of corroded bottom portion of the water cooler of any make & capacity with MS angle iron of suitable size as per existing, including welding/brazing with MS sheet 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as specified and as directed.
Supply and fix in repairs old defective water storing body of water cooler 40/80 or 60/120 ltr capacity by dismantling the outer body of the storage tank after disconnecting its suction and discharge line, taking out glass wool safely placing new stainless steel water storing body of same size including packing with glass wool, connecting suction/discharge line and fixing of body etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in Repairs new sealed unit compressor (Make :As per Exisitng Make or Equivalent) Suitable for water cooler of capacity 40/80 litre , ( Compressor shall not got repaired from trade). complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in Repairs new sealed unit compressor (Make :As per Exisitng Make or Equivalent) suitable for water cooler of capacity 60/120 litre. ( Compressor shall not got repaired from trade). complete all as specified & as directed by Engineer-In -Charge.
M & L Gas Charging to water cooler after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, identifying the leakage, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Refrigerant will be issued under respective Item of this Schedule)
General servicing of the desert coolers including dismantling of various internal and external parts cleanig ,scraping the rust and old paint wherever necessary painting with red-oxide metal primer from inside and one coat of synthetic enamell paint of approved color from outside ,carrying out maintenance / repairs, separating panels, pump, wood wool pads, float valve etc, cleaning the tank, tray, clearing of spray nozzles / holes, supply and fix new set of wood wool or Khus pads/grass pads reassembling the desert cooler and connecting up the controls and making desert cooler serviceable complete all as specified & as directed by Engineer-In -Charge.
Supply and Fix in Repairs water lifting pump 1/70 HP capacity , operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr -in-charge.
Supply and Fix in Repairs electronic control circuit board (PCB) as per existing type for desert cooler.
Supply and Fix in Repairs swing motor for Air cooler / Split AC as per existing Sample
Supply and Fix in Repairs fan motor of desert cooler of any capacity including supporting legs ,nuts and bolts etc.
Supply and Fix in Repairs fan blade with bush for desert cooler motor
Supply only Refrigerant (R-22) gas (enclosed in seamless new steel cylinder) duly tested of complete all as specified and directed by Engineer-in-Charge.
Supply only Refrigerant (R-134) (enclosed in seamless new steel cylinder, ) duly tested complete, all as specified and directed by Engineer-in-Charge.
Supply only Refrigerant (R-410A) (enclosed in seamless new steel cylinder) duly tested complete, all as specified and directed by Engineer-in-Charge.
Supply only Refrigerant (R-32) (enclosed in seamless new steel cylinder, ) duly tested complete, all as specified and directed by Engineer-in-Charge.
Supply and Fix in Repairs over load protector of various capacities for split AC, Winodw AC, water cooler, Refrigerator, deep freezer, complete all as specified & as directed by Engineer-In -Charge.
Supply and Fix in Repairs thermostats with control knob of various capacities split AC, Winodw AC, water cooler, Refrigerator, deep freezer, complete all as specified & as directed by Engineer-In -Charge.
Supply and Fix in Repairs blower/condensor fan blades as per existing make & type for Air conditioner/Water cooler/deep freezer/Desert Cooler all as specified and directed.
Supply and Fix in Repairs relay suitable for split AC, Winodw AC, water cooler, Refrigerator, deep freezer etc,complete all as specified and directed by Engineer in Charge
Supply and Fix in Repairs starting capacitor for split AC, Winodw AC,, water cooler, Refrigerator, deep freezer etc of capacity 80/100 mfd 440 VAC Make Epcos or Equivalent, complete all as specified and as directed by Engineer -in -Charge
Supply and Fix in Repairs capacitor for split AC, Winodw AC, water cooler, Refrigerator, deep freezer etc of capacity 2.5 to 25 mfd Make -Epcos or Equivalent , complete all as specified & as directed by Engineer -in -Charge
Supply and Fix in Repairs running capacitor for split AC, Winodw AC, water cooler, Refrigerator, deep freezer etc of capacity 36/45/50/60 mfd , 440 VAC Make Epcos or Equivalent ,complete all as specified and as directed by Engineer -in -Charge
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil all as specified and directed
Returning, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed
Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed.
M&L for Cutting existing CI / DI pipe in position for insertion of new pipe/tees, branches etc. of size 300 mm dia
All as per above item 112 but 250 mm dia
All as per above item 112 but 200 mm dia
All as per above item 112 but 150 mm dia
All as per above item 112 but 100 mm dia
All as per above item 112 but 80 mm dia
Taking up cast iron/ Ductile iron water mains including flanged rubber joints with spigot and socket ends and lead joint burning out and recovering lead of size :- 300 mm dia
All as per above item 118 but 250 mm dia
All as per above item 118 but 200 mm dia
All as per above item 118 but 150 mm dia
All as per above item 118 but 100 mm dia
All as per above item 118 but 80 mm dia
Supply, laying, jointing and testing DI (Ductile iron ) pipes with spigot and socket ends,centrifugally cast cast class k9 in any length and laid in trenches & walls as per site requirement of bore 300 mm . Complete all as specified and as directedby Engineer-In-Charge.
All as per above item 124 but 250 mm dia
All as per above item 124 but 200 mm dia
All as per above item 124 but 150 mm dia
All as per above item 124 but 100 mm dia
All as per above item 124 but 80 mm dia
M&L for run lead joints complete for water mains with spigot & socket pipes and fittings, all as specified and directed. Bore of pipe :- 300 mm dia. Note : Rate for excavation and earth work incl T&P as reqd at site for each joint are deemed to be included in quoted rates.
All as per above item 130 but 250 mm dia
All as per above item 130 above but 200 mm dia
All as per above item 130 but 150 mm dia
All as per above item 130 but 100 mm dia
All as per above item 130 but 80 mm dia
Supply & fix mechanical joint ISI marked for spigot end pipe, cast iron, detachable of size : 300 mm of cast iron detachable,Note : Rate for excavation and earth work incl T&P as reqd at site for each joint are deemed to be included in quoted rates.
All as per above item 136 but 250 mm
All as per above item 136 but 200 mm
All as per above item 136 but 150 mm
All as per above item 136 but 100 mm
All as per above item 136 but 80 mm
Dismantling/taking out unserviceable air release valve of size 80 mm by opening/cutting rusted nuts, bolts making necessary arrangement and fixing new cast iron double ball air release valves of size 80mm as per IS 14845, PN rating H-7 ISI marked. all as specified and directed.
Dismantling/taking out unserviceable non return valve of size 300 mm by opening /cutting rusted nuts, bolts making necessary arrangement and fixing new CI double end flanged and drilled non return valve with by pass arrangement of size 300 mm dia, ISI marked Make Zoloto /Leader/Kirloskar or Equivalent all as specified and directed.
All as per Item No.143 above but for 150 mm dia Make Zoloto /Leader/Kirloskar or Equivalent
M&L for rubber gasket joint suitable of DI pipe and fittings with size of nuts, washer & bolts etc complete all as specified and directed for the sizes:- upto 300 mm bore dia
M&L for Repair to CI foot valve of dia 150 mm by taking it out from existing position(Sump),transporting it to workshop, reparing the mesh and ball complete ,replacement of flap and nut bolt and washer making it serviceable , complete all as specified and as directed by Engineer-In-Charge.
Supply only pig lead wool ,complete all as specified and as directed by Engineer-In-Charge.
Supply & fix Fully Automatic Star Delta Motor starter 20 HP in sheet-steel enclosure type MK-1S (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14
Supply & fix DOL Motor starter 7.5 HP in sheet-steel enclosure type MK-1 (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Volts, 50 Cycles, and taking out to workshop (Workshop will be decided by Engr-In-Charge) induction motor 60 HP/50 HP/40 HP for repair purpose including complete cleaning,varnishing ,reinsulation and replacement of DE /NDE bearings and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. (note- Rewinding will be measure & paid seperately under relavant item of sch.)
All as per Sr item No 150 above but of capacity 25 HP/20 HP/15 HP
All as per Sr item No 150 above but of capacity 10 HP/ 7.5 HP/ less than 7.5 HP
Material & labour for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of existing coil with similar class of existing insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by engr -in - charge
Material & Labour for Repairs to centrifugal pump set of Make :Kirloskar, Model No DSM 4M ,32 LPS discharge and 50 HP capacity installed at sakora pump house (For technical area),,dismantling the pump set carefully from its connected electric motor including disconnecting and taking out the electric motor,transporting the pumpset to workshop for complete overhauling the pump set with the following replacement/repairs of pump set respectively all as specified and directed by Engineer-in-Charge. opening it through its casing For Dismantling pump and motor and carrying out repairs/overhauling including cleaning of casing and impeller, clogged, discharge line and oil chamber, Greasing and oiling of all moving parts & Refixing and recommissioning of pump with motor in proper alignments and recommissioning ,testing of pump set to the complete satisfaction of Engineer in charge. (Note:- a) Workshop will be decided by Engr-In-Charge. b) Spares as required shall be measure & paid seperately against the relevant items).
supply & fix Casing Wear Ring
supply & fix Shaft sleeve
supply & fix Inter Stage Ring
supply & fix Ball bearing SKF - 7310
supply & fix Ball bearing SKF - 6310
supply & fix Bearing cartridge DE
supply & fix Bearing cartridge NDE
supply & fix shaft sleeve Nuts
supply & fix Split Gland
Supply and fix oil seal set
Supply and fix in Repair to bush cast alloy
Supply and fix in Repair to the main spindle shaft (incl machining/ lathe work)
Supply and fix in Repair to the key and impeller (incl machining/ lathe work)
Supply and fix in Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side.
Supply and fix in Replacement of terminal plate for electric motor.
Supply and fix in Repairing of Sleeve of the casing of the bearing & Repair of any major or minor defects
All as per Sl. Item No.46 here in before but of Make :Kirloskar, Model No DSM 80/35 ,66 cu.m/hr discharge and 40 HP capacity installed at sakora pump house (For Raksha Nagar area) to the complete satisfaction of Engineer-in-Charge.
supply & fix Casing Wear Ring
supply & fix shaft sleeve
supply & fix Inter Stage Ring
supply & fix Ball bearing SKF - 7310
supply & fix Ball bearing SKF - 6310
supply & fix Bearing cartridge DE
supply & fix Bearing cartridge NDE
supply & fix shaft sleeve Nuts
supply & fix Split Gland
Supply and fix Oil seal set
Supply and fix in Repair to bush cast alloy
Supply and fix in Repair to the main spindle shaft (incl machining/ lathe work)
Supply and fix in Repair to the key and impeller (incl machining/ lathe work)
Supply and fix in Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side.
Supply and fix in Replacement of terminal plate for electric motor.
Supply and fix in Repairing of Sleeve of the casing of the bearing & Repair of any major or minor defects
All as per Sl. Item No.46 here in before but of Make :Kirloskar, Model No DSM /4MB , 128 cu.m/Hr capacity and 60 HP capacity installed at sakora pump house (For technical area) , to the complete satisfaction of Engineer-in-Charge.
supply & fix Casing Wear Ring
supply & fix shaft sleeve
supply & fix Inter Stage Ring
supply & fix Ball bearing 7310
supply & fix Ball bearing 6310
supply & fix Bearing cartridge DE
supply & fix Bearing cartridge NDE
supply & fix shaft sleeve Nuts
supply & fix Split Gland
Supply and fix oil seal set
Supply and fix in Repair to bush cast alloy
Supply and fix in Repair to the main spindle shaft
Supply and fix in Repair to the key and impeller
Supply and fix in Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side.
Supply and fix in Replacement of terminal plate for electric motor.
Supply and fix in Repairing of Sleeve of the casing of the bearing & Repair of any major or minor defects
All as per Sl. Item No.46 here in before but of Make :Kirloskar, Model No UP/00/35 , 108 cu.m/Hr capacity and 20 HP capacity installed at Raksha Nagar Pump House to the complete satisfaction of Engineer-in-Charge.
supply & fix Casing Wear Ring
supply & fix shaft sleeve
supply & fix Inter Stage Ring
supply & fix Ball bearing SKF 7310
supply & fix Ball bearing SKF 6310
supply & fix Bearing cartridge DE
supply & fix Bearing cartridge NDE
supply & fix shaft sleeve Nuts
supply & fix Split Gland
Supply and fix oil seal set
Supply and fix in Repair to bush cast alloy
Supply and fix in Repair to the main spindle shaft (incl machining/ lathe work)
Supply and fix in Repair to the key and impeller (incl machining/ lathe work)
Supply and fix in Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side.
Supply and fix in Replacement of terminal plate for electric motor.
Supply and fix in Repairing of Sleeve of the casing of the bearing & Repair of any major or minor defects
All as per Sl. Item No.46 here in before but of Make :Kirloskar, Model No DB100/40, 90 cu.m/Hr capacity and 25 HP capacity installed at MAP Pump House to the complete satisfaction of Engineer-in-Charge.
supply & fix Casing Wear Ring
supply & fix shaft sleeve
supply & fix Inter Stage Ring
supply & fix Ball bearing SKF 7310
supply & fix Ball bearing SKF 6310
supply & fix Bearing cartridge DE
supply & fix Bearing cartridge NDE
supply & fix shaft sleeve Nuts
supply & fix Split Gland
Supply and fix oil seal set
Supply and fix in Repair to bush cast alloy
Supply and fix in Repair to the main spindle shaft (incl machining/ lathe work)
Supply and fix in Repair to the key and impeller (incl machining/ lathe work)
Supply and fix in Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side.
Supply and fix in Replacement of terminal plate for electric motor.
Supply and fix in Repairing of Sleeve of the casing of the bearing & Repair of any major or minor defects
M&L to Repairs to vacuum pump of 50 LPM capacity Kirloskar Model No DV40 coupled with electric motor 3 PH 440V , 50Hz, 5.0 Hp capacity 1450 RPM after disconnecting the electric connections,transporting the pumpset to workshop and transporting the pumpset to workshop ,dismantling the pump set carefully from its connected electric motor including disconnecting and taking out the electric motor,transporting the pumpset to workshop for complete overhauling the pump set with the following replacement/repairs of pump set respectively all as specified and directed by Engineer-in-Charge. opening it through its casing For Dismantling pump and motor and carrying out repairs/overhauling including cleaning of casing and impeller, clogged, discharge line and oil chamber Greasing and oiling of all moving parts Refixing and recommissioning of pump with motor in proper alignments and recommissioning ,testing of pump set to the complete satisfaction of Engineer in charge. (Note:- Spares as required shall be measure & paid seperately against the relevant items).
supply and Fix in replacement Impeller
supply and Fix in replacement Gland Bush
supply and Fix in replacement Wearing Plate
supply and Fix in replacement Ball Bearing set
supply and Fix in replacement Stuffing box cover
supply and Fix in replacement Shaft Sleeve DE & NDE
supply and Fix in replacement Shaft
Supply Only Semiconductor fuse 300 A, Make- L&T. (For soft starter pannel)
M&L for Excavation in trench, detecting the leakage in existing pipeline and taking out the leakage pipe line of size 80 mm to 300 mm and repair the same by replacement of water mains/pipe with joint any type of suitable size compleet all as specified and as directed by engr in charge . Note :a)Pipe line will be measusered and paid separately. b) The rate of T&P are deemed to be included in quoted rate.
Repairs to submersible electric motor 3 phase 440V , 50Hz, 3.0 Hp capacity after taking out (connecting pipes/cable and submersible pumpset) from existing dugwell located at domestic area/raksha nagar (240 feet deep) with help of crane ,transporting the pumpset to workshop opening electric motor ,removing the burnt winding of motor from stator cleaning the enamelled slots carefully rewinding the stator with best quality super enamelled copper winding wire insulated as per existing size and number of turns, varnishing the winding with best quality varnish heating the winding for dyness, and finding out the defects segregating the serviceable spare parts for reuse and including machine work, reassembling the pump set after successful repair and refixing to the existing position and testing complete all as specified and directed.Make Kirloskar. (Note:- Spares as required shall be measure & paid seperately against the relevant items).
supply & fix Spacer Sleeve
supply & fix Top Sleeve
supply & fix Lock Washer
supply & fix Thrust Washer
supply & fix Bearing Sleeve for Bowl
supply & fix Bearing Bush G.M. for Bowl
supply & fix Neck Ring (Wear Ring)
supply & fix Bearing Bush GM for I.P.
Supply and Fix bearings (Make SKF) of suitable size.
supply & fix Replacement of main spindle shaft of suitable size
supply & fix Replacement of bush cast alloy of suitable size.
supply & fix Replacement of oil seal set complete
supply & fix Replacement of main spindle shaft sleeve of suitable size.
supply & fix Replacement of keys and multistage impellers of suitable size.
supply & fix Replacement of MS coupling with chain coupling including drilling required side of hole on either side.
supply & fix Replacement of terminal plate for electric motor.
supply & fix scrapping down existin paint & painting two coats of synthetic enamel paint over one coat of red oxide
Material & labour for taking down sluice valve from existing location,transporting it to workshop ,opening it through its head ,making necessary servicing /repair to its gate by doing machining or Lathe work,/fabricating as per valve /replacement of gland , replacement steel spindle with brass spindle & brass check nuts for sluice valve of 300 mm size,painting with synthetic enamel paint,installing and testing valve at original location using new rubber gsket and new nut bolts & washers of SS-304 for leakage free & smooth operation ,complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.267 here in before but 250 mm size, complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.267 here in before but 150 mm size, complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.267 here in before but 100 mm size, complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.267 here in before but 80 mm size, complete all as specified and as directed by Engineer-In-Charge.
Dismantling and taking out old unserviceable CI sluice valve from existing position and Supply & Fix CI sluice valve ISI marked PN-1 confirming to IS14846 both ends flanged with stainless steel stem with high tensile gun metal parts, iron wheel head check nuts etc including jointing with rubber gaskets, nuts, bolts and washer of sizes 80 mm dia Make:Zoloto or Equivalent in Leader/Kirloskar complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.272 here in before but of sizes 100 mm dia of Make:Zoloto or Equivalent in Leader/Kirloskar ,complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.272 here in before but of sizes 150 mm dia of Make:Zoloto or Equivalent in Leader/Kirloskar,complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.272 here in before but of sizes 300 mm dia Art No 1079A of Make:Zoloto or Equivalent in Leader/Kirloskar ,complete all as specified and as directed by Engineer-In-Charge.
M&L for Dismantling old unserviceable valve chamber & Material & Labour for construction of valve chamber of size 0.9x0.9x0.9 mtrs internal dimension complete of brick masonary of 23 cm thick in cement mortar 1:6 on PCC 1:4:8 foundation 75 mm thick using 40 mm graded stone aggregates & coping in PCC having wall thickness of 0.26 mtrs 1 :3:6 10 mm thick at the top of brick wall using 20 mm graded stone aggregates and 10 mm thick plastering in cement mortar 1:4 on exposed brick or concrete surfaces & MS cover of 3.15 mm thickness including 40 mm×40mm× 6 mm angle iron frame fixed with the same size of angle iron hold fast,handle with locking arrangement & two coats of synthetic enamel paint over one coat of red oxide primer on steel surface and two coats of white wash on plastered concrete surface ,complete all as specified and as directed by Engineer-In-Charge.
All as per SI. Item 276 here in before but of size 1.2x1.2x1.2 mtr internal dimension
M&L for Repairs to verticle type sewage handling pump set of Make :Kirloskar, Model No Dry/s type ,114 cu.m/hr discharge, and 25 HP capacity installed at sewage booster pump house ,dismantling the pump set carefully from its connected electric motor including disconnecting and taking out the electric motor,transporting the pumpset to workshop for complete overhauling the pump set with the following replacement/repairs of pump set respectively and Refixing and recommissioning of pump with motor in proper alignments and recommissioning ,testing of pump set to the complete satisfaction of Engineer in charge. Note: Workshop to be decided by Engr-In-Charge.
Supply and fix in repairs Gland Bush Split type
Supply and fix in repairs Impeller Nut
Supply & fix Ball bearing SKF of suitable size
supply & fix shaft sleeve gun metal
supply & fix Repair to bush cast alloy
Supply & fix Repair of Damaged oil seal
supply & fix Repair to the main spindle shaft
supply & fixRepair to the key and impeller
Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side
supply & fix in Replacement of terminal plate for electric motor
All as per item No. 288 above but capacity 15 HP & discharge 106.00 Cu.M/Hr pump set.
Supply and fix in repairs Gland Bush Split type
Supply and fix in repairs Impeller Nut
Supply & fix Ball bearing SKF of suitable size
supply & fix shaft sleeve gun metal
supply & fix Repair to bush cast alloy
Supply & fix Repair of Damaged oil seal
supply & fix Repair to the main spindle shaft
supply & fix Repair to the key and impeller
supply & fix Repair/Replacement to the Existing coupling with tyre coupling including drilling required side of hole on either side
supply & fix in Replacement of terminal plate for electric motor
Supply & Fix in repair pool pipe 2 inch dia PVC pipe for suction sweeper non toxic including necessary adaptor & fittings complete all as specified and as directed by Engineer in charge.
Material & Labour for repairing,servicing of existing diaphragm valve & replacing existing diaphram with new diaphram for 150 mm dia ,complete all as specified and as directed by Engineer-In-Charge
Supply only calcium hypochlorite 65% to 70% chlorine content in granular (calcium based granular disfenction for water treatment for swimming pool & drinking purpose packed in non returnable plastic drum of 45 kg complete, brand having pan india availability,acceptability & being manufactured in open market termed as traditional product.The brand/makes meeting technical requirement as per PS must have certified by all india institute of hygenic & public health.Test reports must indicate the sample has been drawn by all india institute of hygenic & public health.Contractor shall render purchase voucher & test reports against each lot of delivery Make:Chlor Sree Rayalseema /Declibac/Potter & watts,Complete all as specified & as directed by Engineer-In-charge.
Supply only Poly Aluminium Chloride-(PAC) coagulant containing approx 29% Al2O3 with basicity of approx 64 packed in 25 kg plastic bags, brand having pan india availability,acceptability & being manufactured in open market termed as traditional product.The brand/makes meeting technical requirement as per PS must have certified by all india institute of hygenic & public health.Test reports must indicate the sample has been drawn by all india institute of hygenic & public health.Contractor shall render purchase voucher & test reports against each lot of delivery Make: DECPAC-P of Declibac/Sree Rayalseema/ Potter & watts ,Complete all as specified & as directed by Engineer-In-charge.
Supply only VG 320 gear oil of Make : Servo Veedol /suitable for worm type gear box complete all as specified & directed
Supply of Chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation through recommended dosing system. Replacement indication: visual & weight variation, Water contact orifice design: Sealed when dry, exposed upon immersion Operation type: Non contact, non inhalatory Cylinder dia: 2.5 inches ± 0.5 inches Cylinder height: Minimum 10.0 inches ± 0.5 inches Item Name:STEQUA 411 AE REFILL Make: Declibac or equivalent
Material and labour for Rectification of leakage of CI/DI pipes of 80 mm to 150 mm dia laid in trenches/ on floor etc. including excavation and eartwork, dewatering and removal of mud or pumping out water etc. by replacing of unserviceable CI fittings and CI pipes of the existing size up to 01 metre length or cocking of lead wool in joints or replacing of rubber gaskets etc. (ISI MARKED) complete all as specified and as directed. Notes:- (a) CI Fittings, CI Pipes more than 01 metre length and lead joints incorporating with the job will be measured and paid separately.
Material and labour for Rectification of leakage of CI/DI pipes of 150 mm to 300 mm dia laid in trenches/ on floor etc. including excavation and eartwork, dewatering and removal of mud or pumping out water etc. by replacing of unserviceable CI fittings and CI pipes of the existing size up to 01 metre length or cocking of lead wool in joints or replacing of rubber gaskets etc. (ISI MARKED) complete all as specified and as directed. Notes:-(a) CI Fittings, CI Pipes more than 01 metre length and lead joints incorporating with the job will be measured and paid separately.
Material & Labour for disengaging motor from gear box,flexible coupling & turbine and blades from aeration tank ,complete Maintenance and Overhualing of surface aerator at STP complete greasing of movable parts,bearing, gear box,& associated SS-316 nut bolts and washers , Refixing and recommissioning of surface aerator with motor in proper alignments and recommissioning and test run from authorised rep of company and testing the pump set to the complete satisfaction & all as specified & as directed by Engineer in charge.
Material & labour for taking down existing flexible coupling from site and replacing it with new flexible coupling along with n SS-316 nut bolts and washers,complete all as specified and as directed by Engineer-In-Charge.
Material & labour for replacement of oil seal of type 90 x 70 x 12 ,complete all as specified and as directed by Engineer-In-Charge.
Material & labour for replacement of oil seal of type 75 x 55 x 12 ,complete all as specified and as directed by Engineer-In-Charge.
Material & Labour for Pumping out water and sediments from overhead resorvoir of capacity 1.50 lakh gallon situated at Technical area and Domestic area and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the OH resorvoir including the walk way arround, by removing all the debries & clearing the bushes,vegetation/weeds/salvage/scrap around 50 metre radius of reservoir , Prepration of surfaces, Applying two coats of white wash inside the overhead resorvoir, and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome,pumpset & associated pipeline (suction & delivery) with synthetic enamel paint as directed by Engineer-In-Charge . etc and marking a portion of size not exceeding more than 1 Sq M with black syntetic enamel paint over a coat of primer and writing in white synthetic enamel paint the sump capacity,date of cleaning , due for cleaning etc.& painting all the valve chambers with apex paint & valves & valve covers with synthetic enamel paint and marking flow direction & area and area of supply etc complete all as specified and directed by Engineer-In- Charge.( Note :-The water inside shall be pumped out with the installed machinery in the pump house to the level it picks up air . Balance quantity shall be vacated by the contractor by providing pump of suitable capacity at his own arrangement the entire scope of item shall be carried out in period of 24 hours so that water supply of area shall not be affected for more than 24 hours)
All as per Sl. Item No. 312 here in before but of Overhead reservoir located at Technical Area of capacity 2.5 Lakhs gallons capacity, complete all as specified and directed by Engineer-In- Charge
All as per Sl. Item No.312 here in before but of Overhead reservoir of capacity 50000 gallons located at Raksha Nagar Area / Domestic Area, complete all as specified and directed by Engineer-In- Charge
Material & Labour for Pumping out water and sediments from the semi underground sump of capacity 50000 gallon situated at technical area , Domestic area & raksha nagar respectively and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the sump including the walk way arround by removing debries & clearing bushes ,vegetation/weeds around 50 metre radius of sump,Prepration of surfaces, Applying two coats of white wash inside the sump, and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome ,pumpset & associated pipeline with synthetic enamel paint as directed by Engineer-In-Charge .etc ,and marking a portion of size not exceeding more than 1 Sq M with black syntetic enamel paint over a coat of primer and writing in white synthetic enamel paint the sump capacity,date of cleaning , due for cleaning & painting all the valve chambers & valves and valve cover with synthetic enamel paint and marking flow direction area and area of supply etc. complete all as specified and directed by Engineer-In- Charge.( The water inside shall be pumped out with the installed machinery in the pump house to the level it picks up air . Balance quantity shall be vacated by the contractor by providing pump of suitable capacity at his own arrangement the entire scope of item shall be carried out in period of 24 hours so that water supply of area shall not be affected for more than 24 hours)
Material & Labour for Pumping out water and sediments from swimming pool of capacity 11.00 lakh litre situated near Technical area and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the swimming pool& painting all the valve chambers with apex paint & valves & valve cover with synthetic enamel paint and marking flow direction area and area of supply etc and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome,pumpset & associated pipeline with synthetic enamel paint as directed ,complete all as specified and directed by Engineer-in-Charge.. ( Note :-The water inside shall be vacated by the contractor by providing pump of suitable capacity at his own arrangement the entire scope of item shall be carried out in period of 24 hours so that swimming pool can be bring back into operation within 24 hours)
All as per Sl. Item No.316 here in before but of Semi -UG sump of capacity 80000 litres located at swimming pool Area, complete all as specified and directed by Engineer-In- Charge
M&L for Pumping out continously raw sewage water & cleaning of underground raw sewage water well of size 4.87 mtr dia x 6.75 mtr deep by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side walls of sewage well with the help of wire brush. Stacking out complete sludge and silt at distance not exceeding 50 mtr from the pump house. Applying two coats of lime wash on side walls of sewage walls on interior & weather proof apex over primer on exterior surfaces of sewage wall and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome,pumpset & associated pipeline with synthetic enamel paint, cleaning the bushes, vegetation, weeds/ debris,around 50 mtr of installation complete all as directed by Engineer-In-Charge
M&L Pumping out raw sewage water & Cleaning of Aeration tanks of size 9.15 mtr x 9.15 mtr x 4.50 mtr by removing sludge and silt completely with the help of electric operated lift machine from the bottom of aeration tank scrapping out complete sludge from side wall of Aeration tanks with help of wire brush stacking out complete sludge and slit at distance not exeeding 50 mtr from tank,and taking out sludge for further dispolal outsidde domestic area .Applying two coats of lime wash on side wall at interiour surfaces & weather proof apex over primer on exterior surfaces ,cleaning and clearing,bushes and vegetaion arround 50 mtr of the tanks, painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome,pumpset & associated pipeline with synthetic enamel paint all as specified and directed by Engineer-in-Charge .
Pumping out raw sewage water and Cleaning of final settling tank of size 11 mtr (dia) x 5 mtr deep by removing sludge and silt completely with the help of electric operated lift machine from the bottom of final settling tank . Scrapping out complete sludge from the side wall of final settling tank with the help of wire brush, stacking out complete sludge and silt at distance not exceeding 50 mtr from the sewage treatment plant. Applying two coats of lime wash on side walls interior surfaces & weather proof apex over primer on exterior surfaces of final settling tank, cleaning and clearing the bushes and vegetation around the 50 mtr of tank area all as specified and directed by Engineer-in-Charge.
M&L for Pumping out continously raw sewage water & cleaning of underground collection pit of size 5.2 mtr x 5.2 mtr x 4.8 mtr deep at MAP Booster by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side wall of sewage well with the help of wire brush. stacking out complete sludge and silt at the distance not exceeding 50 mtr from pump house. Applying two coats of lime wash on side wall of sewage well on interior & weather proof appex over prime on exterior surface of sewage wall and painting of inlet , outlet pipe CI/DI/MS pipe at tank/sump at the base, dome,pumpset & associate pipeline with synthetic enamel paint as directed by Engr-In-Charge.
M&L for Pumping out continously raw sewage water & cleaning of Equalisation tank at MAP STP of size 6.8 mtr x 5.8 mtr x 3.2 mtr deep by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side wall of sewage well with the help of wire brush. stacking out complete sludge and silt at the distance not exceeding 50 mtr from pump house. Applying two coats of lime wash on side wall of sewage well on interior & weather proof appex over prime on exterior surface of sewage wall and painting of inlet , outlet pipe CI/DI/MS pipe at tank/sump at the base, dome,pumpset & associate pipeline with synthetic enamel paint as directed by Engr-In-Charge.
M&L for Pumping out continously water & cleaning of clean water tank of size 5 mtr x 5 mtr x 1.5 mtr deep at MAP STP by removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side wall of sewage well with the help of wire brush. stacking out complete sludge and silt at the distance not exceeding 50 mtr from pump house. Applying two coats of lime wash on side wall of sewage well on interior & weather proof appex over prime on exterior surface of sewage wall and painting of inlet , outlet pipe CI/DI/MS pipe at tank/sump at the base, dome,pumpset & associate pipeline with synthetic enamel paint as directed by Engr-In-Charge.
M&L for Pumping out continously water & cleaning of chlorine tank of size 2.3 mtr x 5.4 mtr x 1.8 mtr deep at MAP STP removing sludge and silt completely with the help of electric operated lift machine from the bottom of raw sewage water well scrapping out complete sludge from the side wall of sewage well with the help of wire brush. stacking out complete sludge and silt at the distance not exceeding 50 mtr from pump house. Applying two coats of lime wash on side wall of sewage well on interior & weather proof appex over prime on exterior surface of sewage wall and painting of inlet , outlet pipe CI/DI/MS pipe at tank/sump at the base, dome,pumpset & associate pipeline with synthetic enamel paint as directed by Engr-In-Charge.
Supply and Fix Swimming Pool plastic Water Overflow Grating Size 500 mm in width complete all as specified color and design as directed by Enginner-in-Charge
All as per Sl. Item No. 325 here in before but of Size 375mm in width.
All as per Sl. Item No.325 here in before but of Size 300mm in width.
Supply and fix ioniser electrode made up of copper -silver alloy of size 10 mm dia and 150 mm long suitable for ionising chamber of size 350 mm dia & 300 mm height Make - Satya Sai Aqua Pura or Equivalent complete all as specified and as directed by Engineer-In-Charge.
Material & Labour for new HDPE pipe of 150 mm dia suitable for 4 kg pressure mounted on suitable support and fixed inside existing back wash tank duly making hole of suitable size,& plastering after fixing inside tank ,white washing or colour washing to the disturbed surface of wall complete matching with the existing touch up Engineer-In-Charge.
Supply and Fix in repair PVC/PU tank of capacity 1000 Ltr coated with thermal insulation with 25 mm thick glass wool with chicken mesh as insulation to insulate complete covering the entire tank with factory backed aluminium foil/cladding necessary plumbing fitting of entire tank making inlet outlet connection With existing pipe are deemed to be included with quoted rate. complete all as specified and as directed by Engr-In-Charge
M&L for repair & overhaulling of non clogging pumpset Make: Grundfos- Model No SE1.75.100.150.2.52S.C.N.51D resulting head of pump : 20.3 mtr, flow 48.2 LPS Type of impeller: S-Tube, Primary shaft seal : SIC-SIC, Secondary shaft seal : SIC-Carbon, Pump housing: Cast Iron EN-GJL250, Impeller: Cast Iron EN-GJL250, Motor: Cast Iron EN-GJL250, Material: Whole Pump in cast iron, Maximum current consumption: 29 A, Insulation class H, Power input P1: 17 KW, Rated power P2: 15 KW, Mains frequency: 50 Hz, installed at STP dry installation, taking down the pump set carefully with help of crane from existing position with connected electric motor transporting the pumpset to OEM authorised dealer workshop with following replacement/ repair of pumpset (a) opening it through its casaing for dismantling pump and motor and carrying out repair/ overhauling including cleaning of casing and impeller, clogged, discharge line and oil chamber (b) Taking out the electric motor and carrying out for overhaulling warnishing the same (c) Repairing the sleeves of the bearing & Repair of any major or minor defects (d) Refixing and recommissioning of pump with motor with proper alingment and recommissioning and test run from authorised rep of company, testing the pump set to the complete satisfaction ( 2 yrs performance warranty shall be submitted for pumps ) Complete all as specified and as directed by Engr-In-Charge. Replacement of following spare part mentioned hereafter in the process of the maintainance will be measured and paid seperately Note: Item mentioned under SI no 223-230 are to be executed from authorized dealer of appointed by OEM exclusively. Item no 224 to 230 are the spare required in the process of maintainance which shall be measured and paid seperately.
Supply and fix Kit, Shaft Seal Cartridge F52 2P A
Supply and fix Bearing set
M&L for Rewinding of motor with suitable gauge copper winding of insulation class (IEC 85) : H
Supply and fix O-Ring set for dry motor NBR
Supply and fix S moisture switch kit
Supply and fix Leakage switch
Supply and top up Oil
S/F fitting for spigot socketed MS pipes Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc,) Tee pieces single branch. "Y" juction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150 mm bore including welding the same at desired location all as specified and directed by Engineer-in -Charge
M&L for fitting for spigot socketed MS pipes Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc,) Tee pieces single branch. "Y" juction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 300 mm bore including welding the same at desired location all as specified and directed by Engineer-in -Charge
Material & labour for fitting for spigot socketed CI pipes Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc,) Tee pieces single branch. "Y" juction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 300 mm bore including welding the same at desired location & taking out unserviceable fitting from existing position ,complete all as specified and as directed by Engineer-In-Charge.
M&L for upto 150mm bore cast iron (CI)/ Ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed. Make :- Kesoram, Kejriwal.
M&L for taking down Air Curtain of any make/any capacity after disconnecting all electrical connection from site, transporting it to the work site if required, complete servicing of blower, drum, motor , cleaning of filter, assembling all parts, installing the machine at same position, testing and commisioning for smooth running. Complete all as specified and as directed by Engr-In-Charge.
Supply and fix in Repairs fan motor suitable for Air Curtain of existing capacity/make, AC single phase 230 volts complete all as specified & as directed by Engineer-In -Charge.
Supply and fix Air Filter for air blower of Make: Usha/Everest Complete all as specified and as directed
S & F GI perforated tray of size 300mmx 50 mm( at both side) with MS channel/ angle supported duly grouted in ground using PCC , complete all as specified and as directed by Engr-In-Charge
Supply and fix cast iron Y-type stainer (flanged), PN 10, flanged ends to BS10 Table 'F'. S.S- 304 Perforated sheet screen - 1 mm of size 150 mm make: Zoloto/Hammer/SIR Complete all as specified and as directed
All as per item 347 but for size 100 mm
All as per item 347 but for size 80 mm
Excavation in trenches not exc 1.5 Mtr width and not exc 1.5 mtr deep for foundation, laying GI pipes in soft/loose soil and getting out,complete all as specified and as directed by Engineer-In-Charge.
All as per item no-350 above but in hard dense soil,
Returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25 cm levers of soil, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials not exc 50m and depositing where directed at a level not exc 1.5 above the starting point, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down old rusted water tubing and connections fixed to wall floor, celing, trench for bore of 15 mm dia , complete all as specified and as directed by Engineer-In-Charge.
All as per item no-354 but bore 20 mm dia
All as per item no-354 but bore 25 mm dia
All as per item no-354 but bore 40 mm dia
All as per item no-354 but bore 50 mm dia
All as per item no-354 but bore 80 mm dia
Supply & Fix GI water tubing medium grade with all fitttings and fixed to wall, floor, ceiling for bore of 15 mm diameter, complete all as specified and as directed by Engineer-In-Charge.
All as per item no 360 above but of bore 20 mm dia
All as per item no 360 above but of bore 25 mm dia
All as per item no 360 above but of bore 40 mm dia
All as per item no 360 above but of bore 50 mm dia
All as per item no 360 above but of bore 80 mm dia
Supply, laying, jointing and testing GI water tubing medium grade with all fitttings in trenches for bore of 15 mm diameter, complete all as specified and as directed by Engineer-In-Charge.
All as per item no 366 above but of bore 20 mm dia
All as per item no 366 above but of bore 25 mm dia
All as per item no 366 above but of bore 40 mm dia
All as per item no 366 above but of bore 50 mm dia
All as per item no 366 above but of bore 80 mm dia
Refixing only old serviceable water tubing medium grade received from item No 5 here in before and connected with new fittings of medium grade as required including cleaning, cutting, threading and fixed to wall, floor, ceiling for bore of 15 mm diameter , complete all as specified and as directed by Engineer-In-Charge.
All as per item no 372 above but of bore 20 mm dia
All as per item no 372 above but of bore 25 mm dia
All as per item no 372 above but of bore 40 mm dia
All as per item no 372 above but of bore 50 mm dia
All as per item no 372 above but of bore 80 mm dia
Supply & Fix in replacement of Bronze gate valve (Hex type) ISI marked screwed both ends of 50 mm diameter Art No 1006 of Make: Zoloto or Equivalent in Leader/L&T complete all as specified and as directed by Engineer-In-Charge.
All as per item no 378 above but of bore 40 mm dia
All as per item no 378 above but of bore 25 mm dia
All as per item no 378 above but of bore 20 mm dia
All as per item no 378 above but of bore 15 mm dia
Material & Labour for carring out repairs to Existing Star delta starter in open execution ,identifying the fault in wiring,rectifying the wiring fault using suitble flexible copper cable Replacement of time delay(timer), single phasing preventer & suitable relay with new one(as required as per its specification or as specified by Engineer -In Charge) ,rewiring of complete starter using suitable size flexible copper cable, suitable upto 60 HP electric motors and testing of electrical circuit/Pumpset to the complete satisfaction of Eng-In-Charge,complete all as specified and as directed by Engineer-In-Charge.(Note :Spares required other than mentioned above in the process of maintenance will be measured and paid separately under relevant item mentioned here after
Supply & fix in repair Contactor ML-02 Aux coil voltage 230 V , Make L&T or Equivalent in Siemens/Standard complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. item no 384 above but Contactor ML-03,Aux coil voltage 230 V
All as per Sl.item no 3384 above but Contactor ML-04, Aux coil voltage 230 V
Material & Labour for structral steel work with MS channel ,angles,tees,beam,plate,pipe for fabricationof ladder ,manhole ,valve chamber,railing including fabrication work i.e welding,cutting drilling,jointing work and painting two coats of synthetic enamel paint over one coat of red oxide and fixing same at desire location, complete all as specified & as directed by Engineer-in Charge
Material and labour for Painting of E/M installation (MAP STP) consist of MS Pipe, MS tank, MS structure, water supply pipes including cleaning the plant/equipment preparation of surface,removing rust, removing all dirt, scale deposits and painting with two coats of synthetic enamel paint over a coat of redoxide prime including marking all machinery with machine numbers and distempering on chilled water mains with oil bound distemper as per existing colour coding complete all as specified & as directed by Engr-In-Charge.
Supply & Fix flexible pipe both end screwed brass nuts of size 15mm dia having length of 300mm suitable for hot water connection,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix in replacement of Bronze ball valve with integral strainer both end screwed of size 15 mm bore Art no 1008 of Make: Zoloto or Equivalent in Leader/L&T ,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix in replacement of PVC stop cock of size 15 mm bore Make: PRAYAG/Jaguar or equivalent ,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix PVC BIB COCK STANDARD of size 15 mm (white) , Make - PRAYAG/Jaguar or Equivalent complete all as specified and as directed by Engineer-In-Charge.
Supply & Lay CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting in 40 mm dia trenches/surface for hot water complete all as specified & directed by Engineer-In-Charge.
Supply and fix in repair cast iron foot valve 150 mm dia with flange end with replacement of existing foot valve.of make: Zoloto/Kirloskar/Leader ,complete all as specified & as directed by Engineer-In-Charge
Supply & Fix in repair Non return valve (NRV) of 100 mm dia bore size both end flanged confirming to PN -1.0 rating ,Make : Zoloto/kirloskar/Leader ,complete all as specified & as directed by Engineer-In-Charge
Drilling and tapping CI/DI/GI water mains (in position) for branch connections of the internal dia 20 mm,complete all as specified & as directed by Engineer-In-Charge.
Supply & Fix in repair Butterfly valve wafer type made up of SG iron,without Lugs,Lever operated,SG iron Disc,Nitrile /Rubber linning/Neoprene lining,Test pressure PN-10/PN-16 150 mm Art No 1078 of Make: Zoloto /Leader /Kirloskar, complete all as specified and directede by Engineer-In-Charge.(Rates quoted are deemed to be included with cutting existing 150 mm MS/HDPE pipe to accomodate butterfly valve,inserting suitable flanges,rubber gaskets,nuts bolts,making necessary welding work & testing the pipeline for trouble free operation)
Material & labour to collect waste(sewage) water sample from domestic area 11 BRD in container,sending it to govt approved NABL accreditted lab , to carry out chemical analysis as well as & phisical parameter & bacteriological parameter test from approved lab & rate quoted are deemed to be quoted with this item.) (Note : - Report from approved NABL lab shall be submitted (Testing of sample before treatment & after treatment will be treated as one job ) for following parameter (i) BOD (ii) COD (iii)SS (iv) Ph:7-8 (v) Outlet coliform (vi)Residual chlorine) , complete all as specified and as directed by Engneer-in-Charge.
Material & labour to collect water sample from Rakshanagar/ Technical area 11 BRD in empty sterlized container, sending it to NABL acreditted lab , to carry out chemical analysis as well as organoleptic, physical & Parameters (Colour, Odour, pH, Turbidity, Total Dissolved solid) , bacteriological parameter (Total Coliform, E.Coli ) and chemical parameter (chloride, Free Residual Chlorine, flouride, Iron, Total alkalinity, total hardness, nitrate, zinc) test from approved lab Every month & rate quoted are deemed to be quoted with this item.) (Note : - Report from approved NABL lab shall be submitted by 15th of the Month.)
M&L for removal green vegetation, cutting of tree with girth not more then 10 cm from water supply installation as STP-1, STP-2, Tech area pump house, Raksh nagar Pump house, MAP pump house incl disposal of cut material not more than 50 mtr distance and levelling surface the ground complete all as specified and as directed by engr- in- charge.( Approx artea - 300 SQM)
S& F Fan motor suitable as per sample for swimming pool
S& F Orthotolidine solution (O-Tolidine ) 500 ml chlorine estimator enclosed in glass bottle all as specified and directed by Engineer-In charge, Make: Thermo Fisher Scientific India Pvt Ltd or equivalent as approved by GE
S& F Glufosinate ammonium 13.5% W/W SL enclosed in plastic container of 1 Ltr suitable as per sample
S& F relay suitable for existing 1 to 3 HP motor suitable as per sample for swimming pool
S& F Tyre coupling with fittings suitable as per sample for swimming pool complete all as specified and as directed by Engr- In- Charge
M&L for preparation of old painted surface of GI/CI/MS pipe 80 mm line , replacement/repairing its support/ supporting structure(angle, channel, clamps, nut bolt etc ) along brick wall/ stone wall and painting with two coats of weather proof apex paint in colour, as directed by engr in charge.
All as per item 406 but for pipe of size 50 mm
M&L for re-winding of 1 HP motor
M&L for re-winding of 2 HP motor
M&L for re-winding of 3 HP motor
Supply and fix in repair Rotational moulded polyethylene water storage tanks of capacity 5000 Litrs (Cylindrical vertical with closed top) hoisted, complete all as specified & as directed by Engineer-in Charge Make : Sintex / Himalaya/Polycon
S&F Straight plain brass ferrules (or connecting screw) screwed both ends and fixed 20 mm dia,complete all as specified & as directed by Engineer-In-Charge.
Supply & fix in repair for MS tubing 40 mm bore (internal) heavy grade class 'C' complete with class 'C' fittings such as bends,Elbow,Tees etc. duly welded to each other for carrying compressed air supply at pressure 7 Kg per sq cm including leak testing of the same & laying in trenches ,fixing on wall / floor/ceiling with necessary clips, clamps and saddles etc. including painting to pipe line with two coats of synthetic enamel paint over one coat of Red Oxide primer including the colour code as specified in relevent IS, complete all as specified and as directed by Engineer-In-Charge.
M&L for preparation of surface for board painting on MS display board of size 5x3 feet or more by scratching the board with emby paper and applying two coats of synthetic enamel paint of blue colour as approved and letter writing with white radium paint having font of size 3" to 1 inch including necessary fabrication/welding work of board, flling metal, applying support metal structure wherever required, complete all as specified and as directed by Engr-ln- Charge. Note: Painting of all display boards (Approx 10 nos. ) at EM installations under AGE E/M at various location in Domestic area Technical Area, Raksha Nagar are deemed to be considered as 1 job.
Material and labour for Rectification of leakage of GI pipes of 15 mm to 25 mm dia laid in trenches/ on floor/ fixing to wall etc. of any size including excavation, earthwork, dewatering and removal of mud or pumping out water etc. by replacing of unserviceable GI fittings like elbow, union, sockets, tees, nipple etc. of appropriate sizes and GI pipes of the existing sizes upto 01 Metre length (ISI MARKED) complete all as specified and as directed Notes:- New GI Pipe more than 01 metre length if required will be measured and paid separately.
Material and labour for Rectification of leakage of GI pipes of 25 mm upto 50 mm dia laid in trenches/ on floor/ fixing to wall etc. of any size including excavation, earthwork, dewatering and removal of mud or pumping out water etc. by replacing of unserviceable GI fittings like elbow, union, sockets, tees, nipple etc. of appropriate sizes and GI pipes of the existing sizes upto 01 Metre length (ISI MARKED) complete all as specified and as directed Notes:- New GI Pipe more than 01 metre length if required will be measured and paid separately.
M&L for rewinding of Booster Pump set of capacity 0.5 Hp to 1.5 HPwith same gauge of super enamelled copper winding wire after cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge
M&L for rewinding of Booster Pump set motor of capacity 2 HP to 3 HP with suitable gauge of super enamelled copper winding wire after cutting the burnt windings cleaning slots including insulating materials PVC sleeves insulation paper wooden stick etc complete all as specified and as directed by Engineer-in-charge
S & F for carrying out repair of power contactor 3 phase, 3 pole of any make any rating upto 80 A, 415 V, 50 Hz with replacement of contact kit and contactor coil of suitable voltage, complete all as specified and as directed by Engr-ln-Charge
Dismantling & taking out defective parts of booster pump set of capacity 0.5 HP to 1.5 HP and refixed after repairs / making complete serviceable by repairing / replacement of defective parts including tranportation to local work shop etc complete all as specified and directed by Engineer-in-charge. Note : - Parts replaced if any shall be paid under relevent items of the schedule
S&F in replacement old Running Capacitor 10.0 MFD
S&F in replacement old Running Capacitor 25.0 MFD
S&F in replacement old Running Capacitor 36.0 MFD
S&F chloroscope test kit range 0.05-5 mg/l as CI2, 1000 number of test, AQUASOL make; Aakiro
M&L for replacement of pressure booster pump 1 HP capacity single phase, 50 Hz mounted on roof for boosting water supply to high pressure and connected with existing water supply pipe line including necessary electrical wire and plug top , NRV socket alll as specified and directed by Engr -in-Charge.
Material & Labour for taking down pumpset upto 25 HP from its existing position by dissconnecting its inlet and outlet replacing its old base over new MS base plate/Chasis,Fixing it in PCC Type C2 1:3:6, making necessary inlet/outlet connections with existing pumpset
S& Fixing DOL starter suitable upto 2 HP water pump as per existing make and model complete all as specified and as directed by Engineer-In-Charge.
S & F in replacement of electronic digital water level indicator wireless communication between tank and pump house 180-260 V, 50 Hz with seven segment red LED display visible board (2.25 inch) high frequency non conducting processor based rust free with three wire system, range of 1 KM from the OHT to pump house, processor based senser at OHT, sensing probe in the tank including three core data shield cable of suitable size upto transmitter, water level indicator electrically operated with indications of level of water in RCC over head tank comprising of one number for each RCC over head tank (capacity up to 1.5 lakh gallons) of staging height up to 25 m and Electronic water level indicator installed at pump house building for smooth functioning complete all as specified and directed.
M&L for Repair to PU/PP/PVC foot valve of dia 150 mm by taking it out from existing position(Sump),transporting it to workshop ,reparing the PVC mesh and ball complete ,rivetting and reinforcing stainless steel support to the foot valve to avoid its buckling/bending,making it serviceable , complete all as specified and as directed by Engineer-In-Charge.
Material & labour for taking down existing butterfly valve from existing position ,checking its collar and flanges/bends,identifying the leakages,replacing damage piece of pipe,bend/flage/collar of NB 150 mm with new one,supply and fixing suitable size HDPE pipe tail piece & stub bend flange to mount over existing NB 150 mm size HDPE pipe, making and fusion joint using suitable type of heater so as to ensure leak proof operation ,incorporating suitable MS clampto ensure leak proof fuctioning incorporating SS 316 nut bolts & washer for fixing valve and testing for leak proof fuctioning , complete all as specified and directede by Engineer-In-Charge
Supply and fix in repair reciprocating chlorine chemical dosing pump 0-100 psi, out put 2US GPD-40 US GPD, RPM-44, Single phase 230 Volt, 50 Hz with all acessories including suspension tank 100 Ltrs, FRP coated single phase electric motor, agitator with shaft & impeller complete all as directed. Make: Declibec
M& L for Cleaning of Suction room of painting bay at Tech area complete incl suction fume filter , sprinkling system and nozzle including suction duct from painting bay to Suction room, Suction pit in paining bay incl all connected parts complete for smooth function of the system. Note - (1) All necessary T&P such as air compressor, blower, pressure pump , ladder etc as required at site are included in quoted rates . (2). The rates for dismantling and refixing of connected machineries during cleaning are included in quoted rates. (3) Contractor has to provide safety PPE (hand gloves, Mask, Safety googles etc) while execution of job, and are deemed to be included in quoted rate.
Material & Labour for taking down pumpset from site Model No NSRP50TBGVIL of Make ANTICO ,transporting it to workshop ,complete servicing replacement of its casing ,replacement of shaft & impeller bringing it back to site,installilng and testing complete for leakage free operation and satisfactory working of the plant, complete all as specified and as directed by Engineer-In-Charge
S & F pressure gauge of dial size 100 mm, bottom connection: 3/8'' bsp MOC: MS casing brass internals, Accuracy: +/-2 % FSD, Range: 0-200 psi with 0-14 kg/cm2 Make: FIEBIG, complete all as specified and as directed by Engr-In-Charge
All as per item 434 but for range 0-150 psi with 0-10.6 kg/cm2
All as per item 434 but for range 0-100 psi with 0-7 kg/cm2
United Enterprises (BID ID -3274444)
SHRI SULAI ELECTRICALS (BID ID -3277436)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .