SE ELECTRICAL
SE ELECTRICAL ELECTRICAL DEPARTMENT AMMA MALIGAI IVth FLOOR RIPON BUILDING GREATER CHENNAI CORPORATION
Supply Installation Testing and Commissioning of 2 Nos of 6.5 Ton Precision Air Conditioner for Server Switch room at 3rd floor of Muthamizh Arignar Kalaignar Mu. Karunanithi Maligai Ripon Building Premises Div 58 Zone V
2024_CoC_482292_1
E.L.D.C.No. SM II/P1/1721/ 2024
Limited
Electrical Works
Works
60 days
CHENNAI
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹24,891
11 Nov 2024
9 Sept 2024
20 Sept 2024
9 Sept 2024
19 Sept 2024
9 Sept 2024
9 Sept 2024 - 18 Sept 2024
Amount
Supply of factory assembled factory tested micro processor controlled 6.5 TR sensible cooling capacity precision package AC unit along with all accessories and motorized Volume Control Damper with actuator as per specification
Installation, testing and commissioning of 6.5TR precision AC package units including mounting indoor unit with suitable arrangement and outdoor units on the existing frame work, pressure testing, vaccumisation refrigerant charging to the required level etc including acceptance testing as per specification
Providing and Laying of refrigerant pipe lines of size 7/8" dia. for hot gas line, leak and pressure testing of refrigerant lines, vaccumising, insulation of refrigerant piping arrangement and first charge of refrigerant for the AC system, complete with nitrile rubber insulation as per specification
Providing and Laying of refrigerant pipe lines of size 5/8" dia. for liquid line, leak and pressure testing of refrigerant lines, vaccumising, insulation of refrigerant piping arrangement and first charge of refrigerant for the AC system, complete with nitrile rubber insulation as per specification
Supply and laying of 4 core 2.5 Sq,mm PVC insulated PVC sheathed copper conductor armoured UG cable between indoor unit to outdoor unit including cable gland end termination as per specification
Supply and laying of 4 core 10 Sq,mm PVC insulated PVC sheathed copper conductor armoured UG cable between indoor unit to LT Panel including cable gland end termination etc. as per specification
Supply and fixing of Ladder Type Cable Tray300 mm width from Indoor unit to Condenser unit as per specification
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .