| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹40.9 L+₹89,749 (2.25%)Rejected-AOC PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹46.7 L+₹6.7 L (16.8%)Rejected-AOC RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹49.8 L+₹9.8 L (24.6%)Rejected-AOC E 30 RAJIV NAGAR BEGAMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L4 | Rejected-AOC Neither lowest nor competitive | |
| 5 | L5₹49.9 L+₹10.0 L (25.0%)Rejected-AOC | L5 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
14 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-I AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2020_MES_396230_1
GE/C-60/2020-21
Open Tender
Civil Works
Item Wise
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹98,000
Yes
2 Jan 2021
18 Nov 2020
16 Dec 2020
18 Nov 2020
14 Dec 2020
2 Dec 2020
18 Nov 2020 - 2 Dec 2020
60 days
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil ,comlete all as specified and directed by Engineer-in-Charge.
Excavat in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil comlete all as specified and directed by Engineer-in-Charge..
M and L for Hardcore of gauge n exc. 63 mm, stone aggragate deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface comlete all as specified and directed by Engineer-in-Charge.
M and L for 150 mm thick cement concrete type B-1 1:2:4 20 mm graded aggregate as in floor top 25 mm layer shall be mixed with metallic floor hardener as per manafectorer's instructions whilst concrete is green broom finishes laid over and including 150mm thick cement concrete type D-2 1:4:8 (40 mm graded ) concrete shall be laid in proper size bags size bags comlete all as specified and directed by Engineer-in-Charge.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 comlete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point soil comlete all as specified and directed by Engineer-in-Charge.
Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’comlete all as specified and directed by Engineer-in-Charge.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'B' comlete all as specified and directed by Engineer-in-Charge.
Supply only Metallic floor hardener comlete all as specified and directed by Engineer-in-Charge.
M and L for cement concrete type C-2 1:4:8 (40 mm graded ) as in foundations, filling and mass concrete complete all as specified and directed by Eng-in-charge
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc comlete all as specified and directed by Engineer-in-Charge.
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and this like comlete all as specified and directed by Engineer-in-Charge.
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for columns, pillars, piers, post and strut comlete all as specified and directed by Engineer-in-Charge.
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for beams, cantilivers, beressummers, lintels over 1.5m span comlete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface comlete all as specified and directed by Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for rough finished surface comlete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished surface comlete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface comlete all as specified and directed by Engineer-in-Charge.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface comlete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over cut to length,bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips comlete all as specified and directed by Engineer-in-Charge.
All as per item no 20 above but but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders comlete all as specified and directed by Engineer-in-Charge.
M& L for rendering 15 mm thick in CM 1 : 4 on other than fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement comlete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in CM 1 : 3 on brick or concrete surfaces (in ceiling) etc finished even and smooth without using extra cement comlete all as specified and directed by Engineer-in-Charge.
M and L for Preparation of newly plastered surface of wall and applying two coats of cement base paint to achieve uniform and smooth surface having no sign of brush mark comlete all as specified and directed by Engineer-in-Charge.
M & L for 15mm bore galvanised steel water tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc comlete all as specified and directed by Engineer-in-Charge. (TATA/JINDAL/PRAKASH).
All as per item no 25 above but 20mm bore pipe
S and F triple layered white coloured rotational moulded polyethlene water storage tank ( cylindrical vertical with closed top ) hoisted and fixed in position all as specified in sr part-I 5000 ltrs capacity including 20 mm ball brass valves ,highb pressure with polythene float and flynut complete ,screwed for flynut complete ,screwed for iron pipe brass fillet and fixed comlete all as specified and directed by Engineer-in-Charge.
M and L for cement concrete type C-2,1:3:6 (40 mm graded ) stone aggregate as in surface channels and drains complete all as specified and directed by Eng-in-charge
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc comlete all as specified and directed by Engineer-in-Charge..
M and L for cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate ) as in roof kerb benching coping etc including weathering slighty rounded or chamfered angles of throating including from work to concrete surface comlete all as specified and directed by Engineer-in-Charge.
M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed/surface in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :
One light/fan/bell point controlled by one one way switch ( switch to be measured and paid separtely)
S&F switch piano flush type 5 Amp SP one way comlete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose 3 phase PVC polycorbonate,isolated body comlete all as specified and directed by Engineer-in-Charge..
M&L angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate comlete all as specified and directed by Engineer-in-Charge.
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base comlete all as specified and directed by Engineer-in-Charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed comlete all as specified and directed by Engineer-in-Charge.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix 10/12 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed comlete all as specified and directed by Engineer-in-Charge.
Taking down old MCCB , TPN DBs , & main switch/ enclosure box of any make and type from the site and making good surface comlete all as specified and directed by Engineer-in-Charge.
Taking down old submain wiring of any size and make from the site and making good surface comlete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed)/ Surface in walls comlete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls comlete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed)/surface in walls all as specified and as directed.
Supply & fix factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing comlete all as specified and directed by Engineer-in-Charge.and conforming to IS : 8623.
M&L MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting comlete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link comlete all as specified and directed by Engineer-in-Charge.
M&L MCB SPN 40 Amp "C " curve comlete all as specified and directed by Engineer-in-Charge.
M&L MCB SP 6 to 32 Amp "C" curve comlete all as specified and directed by Engineer-in-Charge.
M&L for earthing of machinery/equipment/panel/installed at power house/subatation, complete with galvanised steel earth palte electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.5 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth protected by 40 mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No.3 of SSR Part-I )2009) and testing on completion comlete all as specified and directed by Engineer-in-Charge.
Supply and fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed comlete all as specified and directed by Engineer-in-Charge.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25x4 mm thick galvanised strip duly fixed on suitable size of porcelain/ PVC insulator comlete all as specified and directed by Engineer-in-Charge.
S&F in replacement branded steel sheet MCCB enclosure box along with 160 A, 4 pole 16 ka MCCB, completely connected with copper thimble and with all accessories comlete all as specified and directed by Engineer-in-Charge.
Taking down old carefully unserviceable T/L fitting of any make and type from the site comlete all as specified and directed by Engineer-in-Charge..
Taking down old carefully unserviceable recess mounted 2'x2' (4x14 watt) light fitting of any make and type from the pop hard pop false ceiling without damaging the existing false ceiling structure and making good the disturbed surfaces around the light fitting with POP and matching with the existing colour comlete all as specified and directed by Engineer-in-Charge..
Taking down old carefully unserviceable Building security light fitting 70 watt of any make and type from the site comlete all as specified and directed by Engineer-in-Charge..
supply and fix recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories comlete all as specified and directed by Engineer-in-Charge.
Note :- Total amount of Sch of credit is Rs.28640.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
LAMBA ENTERPRISES
SHREE RAM BUILD TECH
GIAN ENGINEERS
AMIT BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .