Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.7 LAccepted-AOC | L-1 | Accepted-AOC Lowest | |
| 2 | L-2₹14.8 L+₹5,034.17 (0.34%)Rejected-Finance 364 ASHOK ROAD 94 GANGULY BAGAN EAST ROAD KOLKATA 700084 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700084 | L-2 | Rejected-Finance GREATER THAN L-1 | |
| 3 | L-3₹14.9 L+₹16,971.24 (1.15%)Rejected-Finance BHAGIRATHIPUR DOMKAL MSD | DOMKAL | MURSHIDABAD | WEST BENGAL | 742101 | L-3 | Rejected-Finance GREATER THAN L-1 |
Tender Value
Refer Docs
EMD Value
₹30,780
Closing Date
25 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Midnapore Mechanical Division.
Government of West Bengal Office of the Executive Engineer, Midnapore Mechanical Division P.H. Engineering Directorate Inda P.H.E. Complex, Kharagpur
Compound lighting and others related work at PH of Dwariberia Scheme And Others water supply scheme in Purba Medinipur Distric under Midnapore Mechanical Division, PHE. Dte.
2024_PHED_762284_5
WBPHE/EE/MMD/NIeT- 09 OF 2024-25
Open Tender
Electrical Work/ Equipment
Item Wise
30 days
Inda, Kharagpuur
Please refer Tender documents.
2 documents required · 2 mandatory
₹30,780
12 Nov 2024
4 Oct 2024
28 Oct 2024
4 Oct 2024
25 Oct 2024
4 Oct 2024
7-meter conical/cylindrical GRP Street Light Pole made by CNC Filament machine using thermoset resin having minimum 65 % glass content in one piece with non decorative GRP singleArm of 1000 mm and MS ring arm of 1' each side and internal junction box (6A SP MCB & 4-way connector ) Resin coated MS base plate. Top-85+- 2 mm ID and bottom 176 +- 2 mm ID.
Supply and delivery at site of energy efficient LED Smart Bright street light fixture with IP66 and IK06 protected LM high pressure alluminium di cast housing with polycarbonate cover capable of delivery standard lumen output as follows .The lens plate should be bolted to the metal core PCB should not be glued . The driving current should be more than 700 mA . It should have internal surge protection of minium 4kv , lumen /watt >100, Drivier efficiency > 85% ,PF >0.95, THD<10% . ENDURASUNDOWNSL40WLED765PASYBOPC/ Any Other Approved/ Any Other Approved
Supply and delivery at site of 1.1 KV grade 2 core 4 sq.mm XLPE insulated Al. Ar. Cable Conforming to IS:7098(Part-I) 1988 for outdoor lighting along with manufactures test certificate. [Make:Gloster/Havells/Polycab/PHED Approved]Supply of cable as per actual requirement at site.
Erection of GFRP pole of length of 7 meter in RCC(1:2:4) foundation of 400x400mm of depth of 1300 mm below GL and 200 mm just above GL. 4 nos "J" type foundation bolt of 20 mm dia and 600 mm long grouted into RCC foundation as per base plate of pole.Projected length of 100 mm also considered for fitting with the base plate of the pole.There should be a provision of two number flexible pvc pipe of 63mm dia for cable entry as per supplied drawing.Also the foundation along material will be made as per departmental drawing and design.
Laying of one No. cable up to 35 sq.mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Fitting fixing above supplied LED light fitting complete with all accessories to be fixed with S&F length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required complete.
Earthing with 1no. Of G.I. earth spike (20 mm dia. X 1.5 mtr. Long) driven into the ground upto 2 mtr.. drawing earth line with separate 6 SWG G.I. Wires providing 15 mm dia. G.I. pipe protection from earth spike feeder box/junction box/poles and fixing to the same by suitable nuts & bolts all complete as per direction of EIC.
Supply and delivery of site including design and manufacturing of aluminium composite panel [ACP 3 MM ALUDECOR Exterior AL-33] LED board with 12 mm imported acrylic posted vinyl letter as per following subject. .......................... WATER SUPPLY SCHEME PUMP HOUSE NO-...... P.H.E.D GOVT OF WEST BENGAL with one side glassing alluminium tube of size 2.5" x 1.5" x 1.5" mm with different colour LED as per direction of EIC.The board should have in built power circuit board connected with LED lamp suitable for operating in 230 volt 50 Hz AC supply[4"x 3"]. a) LED lighting should be of 1.5 watt original samsung ( 3 years warranty) fitting LED modules connected for 12 V, 400 watt power (2 years gurantee). b) The board black side should have exterior ACP cover and outside yellow acrylic border ( if asked for) included with making of all (N.B: each board size 12 sq. ft) Installation of above LED board on the top of the pump house proper position after making suitable size frame including supply 7/20 PVC insulated sinngle core alluminium cable approx length 20 mtr. As per direction of EIC & 16 amp DP MCB with power connection. N.B : Matter will be collected from the office
Installation of the above LED board on the top of the pump house proper position after making suitable size frame including supply 7/20 PVC insulted single core aluminium cable approx length 20 mtr. As per direction of EIC & 16 amp DP MCB with power connection.
PS AND ASSOCIATES (BID ID -5709869)
M/S.S.S.ENTERPRISE (BID ID -5699969)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .