Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC | ₹39.2 L Quoted ₹39.8 L | L1 | Accepted-AOC Lowest quoted amount overall reasonable |
| 2 | L2₹39.8 L+₹1,865.50 (0.05%)Rejected-AOC | ₹39.8 L+₹1,865.50 (0.05%) | L2 | Rejected-AOC 2nd lowest hence rejected |
| 3 | L3₹40.0 L+₹20,057.50 (0.50%)Rejected-AOC | ₹40.0 L+₹20,057.50 (0.50%) | L3 | Rejected-AOC 3rd lowest hence rejected |
| 4 | L4₹40.6 L+₹80,997.50 (2.04%)Rejected-AOC | ₹40.6 L+₹80,997.50 (2.04%) | L4 | Rejected-AOC 4th lowest hence rejected |
| 5 | L5₹40.6 L+₹81,288.50 (2.04%)Rejected-AOC | ₹40.6 L+₹81,288.50 (2.04%) | L5 | Rejected-AOC 5th lowest hence rejected |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
24 Dec 2020, 6:00 pmClosed
Garrison Engineer Belgaum
Garrison Engineer Belgaum Laxmitek Camp Belgaum 590009 Karnataka
SPECIAL REPAIRS TO BUILDING No. 87, SPECIAL REPAIRS TO SECURITY WALL OF SCHOOL CAMPUS, PROVISION OF FALSE CEILING AND CONNECTED WORKS IN BUILDING No. 10 ABOS AND LEVELLING OF GROUND AT RMS BELGAUM UNDER GE BELGAUM
2020_MES_401937_1
GE/ BEL/ OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
Belgaum
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Belgaum
₹98,000
Yes
7 Jan 2021
8 Dec 2020
26 Dec 2020
9 Dec 2020
24 Dec 2020
9 Dec 2020
Amount
Demolition of plain cement concrete in ground floors and pavings n. exc. 15cm thick, below or above GL all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not specifically provided for including cutting the reinforcement as ordered all as specified and directed.
Demolition of plain cement concrete of any description and in any position not specifically provided for all as specified and directed.
Demolition of PCC block masonry built in cement mortar, in any position below or above ground level all as specified and directed.
Dismantling of battens for tiles, shingles etc, of any size spacing exceeding 15cm including tilting fillets in roofing all as specified and directed.
Dismantling timber scantlings 40 sq.cm and over in section, in any position, in un-framed work all as specified and directed.
Taking down chowkhat with shutters (without taking off shutters from the frame) area n exc 1.5 Sqm each all as specified and directed.
Taking down chowkhat with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n exc 4 Sqm each all as specified and directed.
Dismantling wrought iron or mild steel work of any description and in any position not otherwise provided for all as specified and directed.
Taking down existing unserviceable barbed wire fencing complete all as specified and directed.
Dismantling of plain or corrugated steel sheets of any gauge and thickness, in roof coverings, valleys, gutters, etc. all as specififed and as directed.
Dismantling of existing single layer Mangalore pattern or similar roofing tiles and making good disturbed roof members all as specified and as directed.
Dismantling of single layer Mangalore pattern or similar tiles in roofing bedded in lime or cement mortar and making good disturbed roof members all as specified and as directed.
Dismantling wall or ceiling boards or insulation boards/ slabs of any thickness including cover fillets all as specified and as directed.
Demolition of stone slab/ tiles/ pavers of any description and any thickness in floors laid, bedded and pointed in any mortar all as specified and directed.
Taking down cement plaster on brick or stone wall or ceiling concrete etc. including racking out joints hacking for key scrubbing down with water etc., all as specified and directed.
Excavation over areas n. exc. 1.5 m deep and getting out in hard/ dense soil all as specified and directed.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m depth for foundation, etc. and getting out in soft/ loose soil all as specified and directed.
Returning filling in with approved excavated soil including spreading levelling, watering and well ramming in layers n. exc. 25 cm thick all as specified and directed.
M&L for Moorum/ red bajri filling, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and as directed.
Removing excavated soil n.exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point in soil all as specified and directed.
Removing excavated soil n.exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point in soil all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick, watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base all as specified and as directed
Rolling and consolidation of formation surfaes in cutting with power roller of capcity exc 8 tonne to 12 tonne all as specified and as directed.
M&L for plain cement concrete type D2 1:4:8 using 40mm graded stone aggregate as in foundation and mass concrete all as specified and directed.
M&L for pre-cast cement concrete solid block masonry, exc 10 cm width, blocks cast in PCC 1:3:6, type C0, using 12.5 mm graded stone aggregate and setting in CM 1:6 all as specified and directed.
M&L for plain cement concrete 1:3:6, type C-1, using 20mm graded stone aggregate as in coping, bed blocks, eaves filling including use of necessary form work all as specified and directed
M&L for Reinforced cement concrete 1:2:4 (nominal mix), Type B1 using 20mm graded stone aggregate in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 (nominal mix), Type B1 using 20mm graded stone aggregate in columns, pillars, piers, posts and struts all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 (nominal mix), Type B1 using 20mm graded stone aggregate in beams, cantilevers, lintels, lintel bands all as specified and directed.
Supply only approved integral water proofing compound all as specified and as directed.
M&L for 2nd class hard wood in scantling, clean sawn fixed in unframed work all as specified and directed.
Fixing only serviceable timber scantling 40 Sq.cm and over in section in any position in un-framed work all as specified and directed.
M&L for use of form work to sides of concrete foundations, column footings, plinth beams and similar works for rough finished flat concrete surfaces, vertical or to batter, all as specified and directed.
M&L for use of form work to sides of pillars, posts, struts, columns, etc. for fair finished concrete surfaces, square, rectangular or polygonal all as specified and directed.
M&L for use of form work to sides and soffits of roof beams, tie beams, lintels, lintel bands and similar works for rough finished flat concrete surfaces all as specified and directed.
M&L aluminium anodised doors standard jindal or equivalent section size 64x38x1.4mm for frame and section size 47x25x2mm for vertical style section size 46.72x44.45x1.4mm top and central rail section size 95x44.45x2mm for bottom rail, section size 19x17.3x0.80mm for glazing clip for shutter including fabrication to required size and fixed with 5mm thick sheet glass ordinary quality in top panel and 12mm thick pre laminated particle board exterior grade pre laminated both sides with decorative choice lamination including fitting etc with floor door closer, handle, mortise lock heavy duty and door spring heavy duty complete all as specified and directed.
M&L for aluminium sliding windows (Triple track), fabricated to required size with standard aluminium anodised sections, with bottom track of size 92 x 31.75 x 1.6mm, side and top frame of size 92 x 31.75 x 1.4mm, top and bottom shutter rail of size 39x17x1.4mm, outer style of size 39 x 17 x 1.4mm, interlock style of size 39 x 27 x 1.4mm, including provision of 4mm sheet glass ordinary quality for panels including provision of all hardware fittings such as handles, locking arrangements, rubber gaskets, rollers, spring catchers etc. complete all as specified and directed. Note: Each window shall be provided with 3 Nos. of glazed shutters of required size.
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending, spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia all as specified and directed.
All as described in item No. 39 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
S&F rolled mild steel angle sections as in purlins, posts, distance pieces, cleats and similar works conforming to Fe-410-W Gde-E-250 quality-A all as specified and as directed.
M&L for mild steel flats as in wind ties for roof including securing bolts and necessary drilling, conforming to Fe-290 Gde E-165 all as specified and as directed.
S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. all as specified and directed.
S&F rolled mild steel posts and struts in fencing and similar work conforming to Fe-290 Gde E-165 including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets for securing wire mesh etc. all as specified and as directed.
M&L for pre-painted galvalume coated high tensile corrugated/ trapezoidal profile steel sheets, AZ-70 coating mass, 550 Mpa yield strength, 0.5mm thick (TCT), as in roofing/ cladding fixed with self drilling fasteners as per manufacturers instructions all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc.
M&L for pre-painted galvalume coated high tensile plain profile steel sheets, AZ-70 coating mass, 550 Mpa yield strength, 0.5mm thick (TCT), as in ridges, valleys, hips, claddings, etc. fixed with self drilling fasteners as per manufacturers instructions all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc.
M&L for 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap in roof, wall etc fixed with L-type or J-type or cranked hook bolts all as specified and as directed.
S&F 4mm thick High Pressure Steam Cured (HPSC) non asbestos fibre cement building board in false ceiling with aluminum anodized snap grids of 60x60cm with Tee section 35x25x1.25mm, angle section 25x25x1.25mm thick including 2mm dia GI hanging wire including all hanger fittings etc including provision three coats of white wash on ceiling all as specified and directed. Note: False ceiling work shall be carried out upto a height of 6m from floor level
M&L for 75mm thick plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in sub base/ levelling course for flooring all as specified and directed.
M&L for MAPLE WOOD FLOORING complete with the following specifications including taking out existing flooring of any description alongwith under frame, etc. including making good the disturbed surfaces all as specified and as directed. Notes: (a) Maple wood shall be original North American maple wood floor board. (b) The contractor shall furnish performance guarantee certificate for the maple wooden floor provided by them for 5 years from the date of completion of contract alongwith security deposit in the form of Term deposit for Rs. 15000/- for the period of 5 years from the date of completion of contract.
WEARING SURFACE: The surface boards shall be 21mm thick kiln seasoned/ treated maple hard wood, 57 to 83 mm wide, random in length, tongue and groove shaped, edges of the boards with a finger lock groove and the bottom side with air pass groove, with moisture content not more than 14%, conforming to World Squash Federation and treated with special anti-termite and water resistant lacquer.
UNDER FRAME: Under frame shall be made of commercial quality imported original Canadian pine wood runners of 70 mm x 45 mm, treated with anti-termite solution and fixed on the bottom side with 10mm thick EPDM air cushioned pads, stapled through the two wings at 300 mm x 300 mm.
INSTALLATION: A vapor barrier of 100 – 200 micron thick shall be provided on the leveled sub-floor before laying the under frame. The runners having air-cushion pads shall be provided on the vapor barrier in perfect level at 300 mm c/c in one direction. The surface boards shall be screwed to the runners through the tongue only and shall lock the screwed tongue by the groove of the adjoining boards. The ends of the boards shall be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion of 8 to 10 mm to be left open between the wooden flooring and the surrounding tiled area/ walls. The Game line marking shall be provided as per WQF standards with recommended colors before applying the finish coat.
FINISHING: After installation, the floor surface shall be machine sanded in to achieve uniform level and finally finished with PU Polishing water based polyurethane lacquer.
M&L for 55 to 60mm thick machine pressed precast concrete interlocking coloured paver blocks with glossy finish on top, M-35 grade, any shape and size with anti skid finish on top confirming to IS 15658-2006 all as specified and directed.
M&L for sand filling under paver bock flooring including watering and consolidation all as specified and as directed.
M&L for coloured, polished, designer cement concrete tiles 25cm x 25cm x 25mm thick, machine pressed, set, jointed and pointed in neat cement slurry, as in pathways, pavings, etc., laid over and including 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
M&L for plain cement concrete 1:3:6, type C1, (Using 20 mm graded stone aggregate), 75mm thick as in plinth protection, finishing the surface fair and even, in panels & filling joints with mortar, etc. all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces or other than fair faces of brick work finished even and smooth without using extra cement complete all as directed.
M&L for rendering 5mm thick in cement mortar 1: 4 mixed with water proofing compound over 10mm thick backing coat in cement mortar 1:6 on stone masonry surfaces or other than fair faces of brick work finished even and smooth without using extra cement complete all as directed. Note: Water proofing compound shall be measured and paid separately.
M&L for two coats of plastic emulsion paint over a coat of alkali resistant primer on newly plastered surfaces of walls over 1mm thick wall care putty including necessary preparation of surfaces all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable), any colour, over a coat of primer over 1mm thick layer of wall care putty, on newly plastered walls, pilasters, cornices, etc., including necessary preparation of surfaces all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable), any colour over a coat of primer over 1mm thick layer of wall care putty on walls, pilasters, cornices, etc., including complete removal of existing treatment and necessary preparation of surfaces all as specified and as directed.
M&L for two coats of cement based paint, any colour, on newly plastered surfaces of walls, pilasters, cornices, etc., including necessary preparation of surfaces all as specified and directed.
M&L for two coats of weather proof exterior acrylic emulsion paint over a coat of alkali resistant primer on newly plastered surfaces of walls, pillasters, roof projections, facias, drops, chajjas, etc., including necessary preparation of surfaces all as specified and as directed.
M&L for preparing surface of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil all as specified and directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparation of new steel surfaces of any description n exc 10 cm width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Taking down carefully existing point wiring of light/ fan/ bell/ 5 Amps socket/ 15 Amps socket/ 2 way light point, etc. complete of any description including fittings and fixtures such as switches, sockets, call bells, ceiling roses, pendants, holders, regulators, call bells, light fittings, etc. and making good the disturbed surfaces of walls, floors, etc. all as specified and directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded cables drawn through and including ISI marked PVC conduits or PVC casing capping of suitable size and all necessary fittings and provision of one run of PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded single core cable of size 1.5 sqmm and connected to common earth dolly including 1/2 module concealed box flush mounted into wall with modular cover plate & frames for mounting switches/ sockets etc. for one light point controlled by one modular switch 1 way complete all as specified and directed.
All as described in item No. 69 but for one ceiling fan point controlled by one switch and regulator.
All as described in item No. 69 but for one 05 Amps socket outlet on independent board.
All as described in item No. 69 but for one 05 Amps socket outlet on the same board with other switches.
All as described in item No. 69 but wiring with 2.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable and with one run of single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable of size 2.5 Sqmm for earth continuity conductor and connecting to common earth dolly, complete for one 15/ 16 Amps modular socket point on independent board all as specified and directed.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 6 sqmm drawn through and 1100 volt grade including ISI marked PVC conduits or PVC casing and capping of suitable size with all necessary fittings and provision of one run of 6 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, including taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces complete all as specified and directed. Note: Two runs of 6 sqmm cable, one run of 6 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
S&F modular switch, 1 module, 1 way, 6 Amps, 230 volts, AC, all as specified and directed.
S&F modular switch, 1 module, 1 way, 16 Amps 230 volts, AC, all as specified and directed.
S&F modular socket outlet, 2 module, 6 Amps 2 cum 3 pin multipurpose all as specified and directed.
S&F modular socket outlet, 2 module, 2 pin 6A/ 3 pin 16 Amps, multipurpose all as specified and directed.
S&F modular fan regulator, step type, 2 module, 120 Watts, 230 volts, AC, all as specified and directed.
S&F PVC ceiling rose 3 terminal suitable for 230 volts AC supply all as specified and directed.
S&F wall mounting fan, 230 volts, single phase, 300mm sweep, with all accessories fixed to wall with all necessary brackets, bolts, nuts, etc. including testing and making good disturbed surfaces complete all as specified and as directed. Make: HAVELLS D'ZIRE or equivalent model in makes CG/ ORIENT
S&F in repairs, MCCB DB VTPN 12 Way, vertical type, suitable for MCCB as incomer 415 volts rated bus bars double door type including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCCB DB on board complete all as specified and directed.
S&F in repairs, MCCB DB VTPN 4 Way, vertical type, suitable for MCCB as incomer 415 volts rated bus bars double door type including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCCB DB on board complete all as specified and directed.
S&F in repairs, MCB DB SPN 12 Way with 100 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F in repairs, MCB DB SPN 8 Way with 100 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F MCCB TPN 125 Amps ,25KA, 415 Volts, AC supply, fixed thermal magnetic settings, all as specified and as directed.
S&F MCB DP 40A 10KA 'C' series 50Hz AC supply including dismantling old one all as specified and as directed.
S&F MCB SP 5-32A 10KA 'C' series 50Hz 240 Volts AC supply all as specified and as directed.
S&F surface mounting LED light fitting, 20W, 230V, wall/ ceiling mounted type, with extruded aluminium housing and polycarbonate diffuser, 20W LED strip, integrated driver and all accessories internally pre wired complete and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block and provision of 2 Nos. of PVC square blocks all as specified and directed. Make: HAVELLS LUMILINE PLUS or equivalent in CG/ Philips/ Wipro
S&F 42 Watts LED glare free luminaire recess mounted in square profile 2ft x 2ft size with 42 W high brightness SMD LEDs including electronic driver etc. complete with all accessories internally pre wired including cutting of false ceiling sheet to required size and fixing aluminium strip as per the existing size in false ceiling for fixing of light fitting and providing aluminium strip supports as reqd and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block all as specified and directed. Make: HAVELLS VENUS NEO HE 2x2 or equivalent in CG/ Philips/ Wipro
S&F 34 Watts LED glare free luminaire recess mounted in square profile 2ft x 2ft size with 34 W high brightness SMD LEDs including electronic driver etc. complete with all accessories internally pre wired including cutting of false ceiling sheet to required size and fixing aluminium strip as per the existing size in false ceiling for fixing of light fitting and providing aluminium strip supports as reqd and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block all as specified and directed. Make: HAVELLS VENUS NEO HE 2x2 or equivalent in CG/ Philips/ Wipro
S&F 25 Watts LED security light fitting, with pressure die cast aluminium housing and lens embedded PC cover having top opening separate driver compartment with IP65 protection, 25 Watts high power LEDs, electronic driver including all accessories internally pre wired complete and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block including provision of bracket made out of GI pipe light grade of suitable size and length and bent to shape fixed to walls/ poles with suitable MS clamps, bolt, nuts etc. complete all as specified and directed. Make: ENDURA PEARL model of HAVELLS or equivalent in Crompton Greaves/ Philips/ Wipro
M&L for approved riddled earth, spread dry in trenches as in cable cushioning at bottom and top including punning down all as specified and as directed. Note :- Punned thickness will be considered for payment.
M&L for burnt bricks, old size, sub class 'B' of designation 75, laid in trenches as in protection for UG cables all as specified and as directed.
M&L for GI tubes, light grade, 40mm bore, as in cable protection, fixed to poles/ walls with necessary MS clamps, bolts, nuts, washers or laid in trenches / under roads/ crossing etc. all as specified and as directed.
M&L for XLPE insulated, armoured, heavy duty electric LT UG cable with multi-stranded aluminium conductor, 1100 Volts grade, cross sectional area 16Sqmm x 4 core, laid in trenches/ passing through pipe/ duct or fixed to wall including provision of necessary lugs/ thimbles/ ferrules, connecting up , testing and commissioning complete all as specified and as directed. Note: Excavation, earth work, sand cushioning, bricks/ GI pipe for protection shall be measured and paid separately under relevant items of this schedule.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground vertically (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the earth plate at a depth not less than 1.5m below normal ground level connected to GI wire 4mm dia (7.5m long) by means of GI bolts nuts washers and GI wire protected by 15mm dia light grade GI pipe (7.5m long) and watering arrangements with 20mm dia GI pipe medium grade and GI funnel all as specified and shown in Electrical Plate No 3 of MES Schedule Part I including necessary excavation and earth work in any type of soil, charcoal, dust salt, PCC 1:2:4 type B1 in chamber, 40mm thick RCC 1:2:4 type B1 in cover slab with 8mm dia TMT bars at 100mm C/C both ways and with 8mm dia MS hook complete and testing all as specified and directed.
M/s. KIRAN M CHOUGULE
M/S SAMARTH CONSTRUCTIONS
M/s A N Kalbhavi
M/s. N D KALING
M/s. J P CONSTRUCTIONS
ASHIRWAD ELECTRICALS
RAJENDRA KRISHNA SARAF
DHANSHRI ENTERPRISES
M/S SANJAY B SHARMA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .